• Title/Summary/Keyword: Beam angle

Search Result 1,349, Processing Time 0.028 seconds

Tilt Angle Generation in NLC on Homeotropic Polymer Surface with Ion Beam Irradiation as a Function of Incident Angle

  • Lee, Sang-Keuk;Seo, Dae-Shik;Choi, Dai-Seub
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.3
    • /
    • pp.120-122
    • /
    • 2008
  • We have studied the tilt angle generation on the homeotropic polyimide (PI) surface using a low intensity ion beam source as a function of incident angle. An excellent LC alignment of nematic liquid crystal (NLC) on the PI surface with ion beam exposure for all incident angles was observed. The tilt angle of NLC on the homeotropic PI surface for all incident angles was from 90 to 88 degree was observed. Also the tilt angle of NLC on the homeotropic PI surface with ion beam exposure of 400 eV had a tendency to increase as ion beam energy incident angle become more instance from 45 degree. Finally, a good LC alignment thermal stability on the homeotropic PI surface with ion beam exposure can be achieved.

Feasibility Study of Laser Contact Angle Measurement for Nano-fiber Characterization (나노섬유의 특성분석을 위한 레이저 접촉각 측정기의 효율성 연구)

  • 신경인;안선훈;김성훈
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.5
    • /
    • pp.554-559
    • /
    • 2003
  • A newly developed contact angle measurement instrument by laser beam projection allows for rapid and direct determination of contact angles. The instrument may have a possibility to characterize newly developed nano-fibers. When the laser beam impinges on an edge of an interface of liquid and solid, projected beam were split across and made two straight lines on a tangent screen. From the result, it could measure the contact angle directly by reading the angle between two split beams. The purpose of this study was to prove reliability and reproducibility of the contact angle measurement instrument by laser beam projection compare to the conventional one by microscope through the comparative experiment and questionnaire. Test samples were selected by consideration of hydrophilic and hydrophobic, such as nylon 6 and polypropylene, respectively. The laser contact angle measurement has accurate, fast and convenient method to measure contact angle, and it can be a unique method to characterize nano-fibers.

Control of Tilt Angle on Homeotropic Polyimide Surface by Ion Beam Alignment (이온빔 배향을 이용한 수직 폴리이미드 표면에서의 틸트 각 제어)

  • Kang, Dong-Hun;Kim, Byoung-Yong;Kim, Sang-Hoon;Hwang, Jeoung-Yeon;Han, Jin-Woo;Kim, Jong-Hwan;Kang, Hee-Jin;Ok, Chul-Ho;Oh, Yong-Cheul;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.288-289
    • /
    • 2006
  • The tilt angle generation of nematic liquid crystal(NLC) on the homeotropic polyimide(PI) surface by the new Ion beam alignment method is studied. The tilt angle of NLC on the homeotropic PI surface for all incident angle is about 38and this has a stabilization trend. And the good LC alignment of the NLC on the PI surface by ion beam exposure of 45Incident angle was observed. Also the tilt angle of NLC on the homeotropic PI surface by ion beam exposure of 45Incident angle had a tendency to decrease as ion beam energy density increase. So we had known that pretilit angle could be controlled from verticality to horizontality.

  • PDF

Multilayered inhomogeneous beam under prescribed angle of twist and displacements: A delamination analysis

  • Victor I. Rizov
    • Coupled systems mechanics
    • /
    • v.13 no.2
    • /
    • pp.153-170
    • /
    • 2024
  • The problem considered in this theoretical paper is the delamination of a multilayered inhomogeneous beam structure that has viscoelastic behaviour under angle of twist, horizontal and vertical displacements which vary smoothly with time according to prescribed laws. The cross-section of the beam is a rectangle. The layers are made of different materials which are smoothly inhomogeneous along the length of the beam. The beam under consideration represents statically undetermined structure since it is clamped in its two ends. The problem of the strain energy release rate is solved. For this purpose, the strain energy stored in the beam structure is analyzed. In order to verify the solution obtained, the strain energy release rate is found also analyzing the time-dependent compliances of the beam under prescribed angle of twist and displacements. A parametric investigation is carried-out by applying the solution obtained. Special attention is paid to the effect of the parameters which control the variation of the angle of twist and the displacements with time on the strain energy release rate.

Vertical Alignment of Liquid Crystal by Ion Beam Irradiation (이온빔 배향에 의한 수직 배향막의 액정 배향)

  • Kang, Dong-Hoon;Kim, Byoung-Yong;Kim, Young-Hwan;Ok, Chul-Ho;Han, Jeong-Min;Kim, Jong-Hwan;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.414-414
    • /
    • 2007
  • In this study, Liquid Crystal (LC) alignment and tilt angle generation in Nematic Liquid Crystal (NLC) with negative dielectric anisotropy on the homeotropic PI surface with new ion beam exposure are reported. Also. high density of ion beam energy (DuoPIGatron type Ar ion gun) is used in this study. The tilt angle of NLC on the homeotropic Polyimide (PI) surface for all incident angles is measured about 38 degree and this has a stabilization trend. And the good LC alignment of NLC on the PI surface with ion beam exposure of $45^{\circ}$ incident angle was observed. Also the tilt angle of NLC on the homeotropic PI surface with ion beam exposure of $45^{\circ}$ had a tendency to decrease as ion beam energy density increase. The tilt angle could be controlled from verticality to horizontality. Also, the LC aligning capabilities of NLC on the homeotropic PI surface according to ion beam energy has the goodness in case of more than 1500 eV. Finally. the superior LC alignment thermal stability on the homeotropic PI surface with ion beam exposure can be achieved. For OCB(Optically Compensated Bend) mode driving, we can need pretilt angles control for fast response time. In this study, We success pretilt angles control. Consequently, this result can be applied for OCB mode.

  • PDF

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.3
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.

Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam

  • Oh, Hyoung Seok;Shin, Hyeongyeop;Ju, Youngkyu;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • v.43 no.3
    • /
    • pp.311-325
    • /
    • 2022
  • For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width.

Finite Element Analysis of the Reinforced Concrete Circular (탄성적으로 지지된 철근콘크리트 선형판의 유한요소 해석)

  • 조진구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.1
    • /
    • pp.59-66
    • /
    • 1993
  • Ring Sector Plate Supported by Elastic Beam Although all the reinforced concrete circular ring sector plates are elastically supported, it is conventional to simplify their supporting conditions as fixed or simply-supported ones assuming that their supporting beam has infinite stiffness. However, in order to obtain a precise solution, it should be required to consider the stiffness of their supporting beam. As a methodological improvement to the precise analysis, "Reinforced Concrete Model" previously developed by the author was applied to the structural analysis of the reinforced concrete circular ring sector plates with elastically supported beam. The results of analysis in the cases under various conditions of open angle, steel ratio, relative stiffness(EI/DL) between plate and supporting beam were summarized as follows ; 1.Although the effect of relative stiffness between plate and supporting beam varies depending on the magnitude of open angle, in general, it shows the largest when not more than 5.0 and negligible when not less than 10.0. Therefore, it would be considered as fixed supporting condition :in the case of its open angle of 0$^{\circ}$rectangular plates), its stiffness ratio being not less than 10.0 and in the other case of its open angle of 30$^{\circ}$, its stiffness ratio being not less than 5.0. 2.In the rectangular plates, the effect of steel ratio is considerable in no supporting condition, but neglible in the supporting condition. So, the effect of steel ratio should be negligible in the case of the elastically supported circular ring sector plates. 3.However, the effect of steel ratio is much more considerable in the case of the fixed supported circular plates, especially, when steel ratio being not more than 1.0% and stiffness ratio being smaller. So, the effect of steel ratio should be considered in the analysis of reinforced concreate circular ring sector plates with fixed conditions. 4.The effect of open angle is greater in the case of without-supporting beam conditions. However, in the other case of with-supporting beam conditions, the effect is a little bit when open angle of not more than 300 and negligible when open angle of not more than 30$^{\circ}$.

  • PDF

LC Aligning Properties for Homeotropic Alignment of NLC on the SiOx Thin Film as Incident Angle of Electron Beam Evaporation Angle

  • Kim, Jong-Hwan;Kang, Hyung-Ku;Han, Jin-Woo;Kang, Soo-Hee;Kim, Young-Hwan;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.21-25
    • /
    • 2006
  • In this study, liquid crystal (LC) aligning properties for homeotropic alignment on the $SiO_x$ thin film by electron beam evaporation method with electron beam system in accordance with the evaporation angles were investigated. Also, the control of pretilt angles homeotropic aligned LC on $SiO_x$ thin film as the function of the evaporation angles were studied. The uniform vertical LC alignment on the $SiO_x$ thin film surfaces with electron beam evaporation was achieved with all of the thin film angle conditions. It is considerated that the LC alignment on the $SiO_x$ thin film by electron beam evaporation is attributed to elastic interaction between LC molecules and micro-grooves at the $SiO_x$ thin film surface created by evaporation. The values of the pretilt angles according to the evaporation angle were from about $0.7^{\circ}$ to about $3.4^{\circ}$. The highest pretilt angles of about $3.4^{\circ}$ in aligned NLC on the $SiO_x$ thin film surfaces by electron beam evaporation were measured under the condition of $45^{\circ}$. Also, good LC alignment states on the treated $SiO_x$ thin film layer by electron beam evaporation were observed at annealing temperature of $250^{\circ}C$. Consequently, the high pretilt angle and the good thermal stability of LC alignment on the $SiO_x$ thin film by electron beam evaporation can be achieved.

Defect Length Measurement using Underwater Camera and A Laser Slit Beam

  • Kim, Young-Hwan;Yoon, Ji-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.746-751
    • /
    • 2003
  • A method of measuring the length of defects on the wall of the spent nuclear fuel pool using the image processing and a laser slit beam is proposed. Since the defect monitoring camera is suspended by a crane and hinged to the crane hook, the camera viewing direction can not be adjusted to the orientation that is exactly perpendicular to the wall. Thus, the image taken by the camera, which is horizontally rotated along the axis of the camera supporting beam, is distorted and thus, the precise length can not be measured. In this paper, by using the LASER slit beam generator, the horizontally rotated angle of the camera is estimated. Once the angle is obtained, the distorted image can be easily reconstructed to the image normal to the wall. The estimation algorithm adopts a 3-dimensional coordinate transformation of the image plane where both the laser slit beam and the original image of the defects exist. The estimation equation is obtained by using the information of the beam projected on the wall and the parameters of this equation are experimentally obtained. With this algorithm, the original image of the defect taken at arbitrary rotated angle can be reconstructed to an image normal to the wall. From the result of a series of experiments, the accuracy of the defect is measured within 0.6 and 1.3 % error bound of real defect size in the air and underwater, respectively under 30 degree of the inclined angle of the laser slit beam generator. Also, the error increases as the inclined angle increases upto 60 degree. Over this angle, the defect length can not be measured since the defect image disappears. The proposed algorithm enables the accurate measurement of the defect length only by using a single camera and a laser slit beam.

  • PDF