• 제목/요약/키워드: Basement Wall

검색결과 80건 처리시간 0.022초

Design Considerations for Concrete High-Rise Buildings

  • Chung, Kwangryang;Park, Chulho;Kim, Dohun
    • 국제초고층학회논문집
    • /
    • 제5권3호
    • /
    • pp.187-193
    • /
    • 2016
  • Busan's Haeundae Resort project, which is currently being constructed by POSCO E&C, comprises the 101-story Landmark Tower and two 85-story residential towers. Presently, foundation and basement construction is complete, with a final completion date set for 2019. Considerations about the construction and design of the three reinforced concrete high-rise buildings will be discussed in this paper.

AN OBSERVATION ON THE FRACTURE SYSTEMS OF THE SOUTHERN VIETNAM

  • Chang Sung Jin;Long Nguyen Tien
    • 한국석유지질학회:학술대회논문집
    • /
    • 한국석유지질학회 2001년도 제8차 학술발표회 발표논문집
    • /
    • pp.6-22
    • /
    • 2001
  • A study of the fracture systems in outcrops of southern onshore Vietnam revealed two kinds of fracture groups according to their origin: cooling fractures and deformation related fractures. Cooling of magma introduced extensive fractures in the batholiths with wide spacing and narrow aperture. They are found widespread in all magmatic bodies, but result in poor reservoir quality due to low bulk porosity and narrow aperture. Cooling fractures are often reactivated during later stress regimes. Deformation related fractures, especially 'fault damage zones' and 'hanging wall deformation' is thought to form the most important reservoir type in the fractured basement rock. The porosity formed by intense fracturing and fault breccia along minor fault zones is thought to be the producing zones in the producing fields of Cuu Long basin. They are found along major faults and widespread in hanging wall blocks.

  • PDF

초고강도 콘크리트로 타설된 내부코아 벽체의 균열발생 및 제어에 관한 실험적 연구 (An Experimental Study on Crack Control of Core-wall Using 700kg/$\textrm{cm}^2$ Ultra High Strength Concrete)

  • 윤영수;이승훈;노병용;박희도
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.201-206
    • /
    • 1995
  • This paper presents the experimental study on crack control of core-wall placed with 700kg/$\textrm{cm}^2$ Ultra high strength concrete. The thermal sensors were installed into the core-walls prior to the concrete casting to measure the heat of hydration and atmospheric temperature whose difference might cause the initial crack. Several curing schemes were taken for each basement floor 8 thru 6 to examine the influence of curing method on the crack width, total crack length and the number of crack occurred. This paper demonstrates that the proper curing scheme have a great favorable effect on the initial crack control on the structural elements with noticiable reduction in crack width.

  • PDF

Investigation of crack growth in a brick masonry wall due to twin perpendicular excavations

  • Mukhtiar Ali Soomro;Dildar Ali Mangnejo;Naeem Mangi
    • Geomechanics and Engineering
    • /
    • 제34권3호
    • /
    • pp.251-265
    • /
    • 2023
  • In urban construction projects, it is crucial to evaluate the impacts of excavation-induced ground movements in order to protect surrounding structures. These ground movements resulting in damages to the neighboring structures and facilities (i.e., parking basement) are of main concern for the geotechnical engineers. Even more, the danger exists if the nearby structure is an ancient or masonry brick building. The formations of cracks are indicators of structural damage caused by excavation-induced ground disturbances, which pose issues for excavation-related projects. Although the effects of deep excavations on existing brick masonry walls have been thoroughly researched, the impact of twin excavations on a brick masonry wall is rarely described in the literature. This work presents a 3D parametric analysis using an advanced hypoplastic model to investigate the responses of an existing isolated brick masonry wall to twin perpendicular excavations in dry sand. One after the other, twin perpendicular excavations are simulated. This article also looks at how varying sand relative densities (Dr = 30%, 50%, 70%, and 90%) affect the masonry wall. The cracks at the top of the wall were caused by the hogging deformation profile caused by the twin excavations. By raising the relative density from 30% to 90%, excavation-induced footing settlement is greatly minimized. The crack width at the top of the wall reduces as a result of the second excavation in very loose to loose sand (Dr = 30% and 50%). While the crack width on the top of the wall increases owing to the second excavation in medium to very dense sand (Dr = 70% and 90%).

Pathological Study on the Pulmonary Toxicity of Particulate Matters (Carbon Black, Colloidal Silica, Yellow Sands) in Mice

  • Shimada, Akinori
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2005년도 춘계 국제심포지엄 및 학술대회
    • /
    • pp.51-82
    • /
    • 2005
  • To compare the pulmonary toxicity between ultrafine colloidal silica particles (UFCSs) and fine colloidal silica particles (FCSs), mice were intratracheally instilled with 3 mg of 14-nm UFCSs and 230-nm FCSs and pathologically examined from 30 mill to 24 hr post-exposure. Histopathologically, lungs exposed to both sizes of particles showed bronchiolar degeneration and necrosis, neutrophilic inflammation in alveoli with alveolar type II cell proliferation and particle-laden alveolar macrophage accumulation. UFCSs, however, induced extensive alveolar hemorrhage compared to FCSs from 30 min onwards. UFCSs also caused more severe bronchiolar epithelial cell necrosis and neutrophil influx in alveoli than FCSs at 12 and 24 hr post-exposure. Laminin positive immunolabellings in basement membranes of bronchioles and alveoli of UFCSs treated animals was weaker than those of FCSs treated animals in all observation times. Electron microscopy demonstrated UFCSs and FCSs on bronchiolar and alveolar wall surface as well as in the cytoplasm of alveolar epithelial cells, alveolar macrophages and neutrophils. Type I alveolar epithelial cell erosion with basement membrane damage in UFCSs treated animals was more severe than those in FCSs treated animals. At 12 and 24 hr post-exposure, bronchiolar epithelia cells in UFCSs treated animals showed more intense vacuolation and necrosis compared to FCSs treated animals. These findings suggest that UFCSs has greater ability to induce lung inflammation and tissue damages than FCSs.

  • PDF

광주읍성 축성암석의 재질분석과 산지해석 (Material Analysis and Provenance Interpretation for Rock Properties of the Gwangjueupseong (Gwangju Town Wall), Korea)

  • 이명성;전유근;서정석;이찬희
    • 보존과학회지
    • /
    • 제25권1호
    • /
    • pp.61-76
    • /
    • 2009
  • 광주읍성은 구 전남도청이 위치한 국립 아시아 문화전당 건립부지 내에서 지표조사 결과 확인된 유적이다. 성벽의 길이는 일부 유실구간을 제외하고 총 85.1m이며, 석벽을 축조하기 위하여 총 10종의 암석이 사용된 것으로 나타났다. 이중에서 석영안산암이 41.1%, 안산암이 35.7%로 가장 높은 점유율을 보였다. 석영안산암은 성벽을 축성하는 주석재로 사용되었으며, 안산암은 주로 큰 부재 사이를 채우기 위한 사잇돌로 사용되었다. 암석학적 및 지형학적으로 볼 때 축성암석의 산지일 가능성이 높을 것으로 판단되는 무등산 일대에 분포하는 암석들을 대상으로 각각의 성인적 동질성을 검토한 결과, 산출상태, 전암대자율, 구성광물의 종류, 상대적 함량 및 조직, 지구화학적 특징이 서로 아주 유사하였다. 또한 무등산 남서쪽 사면의 증심사 계곡을 따라 석영안산암의 노두에서는 암석의 채석 흔적이 산재한다. 따라서 광주읍성의 축성에 사용된 대량의 석재는 무등산 남서 사면에서 조달하였으며, 석재의 이동은 광주천을 이용하였을 가능성이 높았을 것으로 해석된다.

  • PDF

벼멸구 겹눈의 미세구조 (Ultrastructure of the Compound Eye of the Rice Brown Planthopper, Nilaparvata lugens (StaL) (Homopteera : Auchenorhyncha : Delphacidae))

  • Young Nam Youn
    • 한국응용곤충학회지
    • /
    • 제34권3호
    • /
    • pp.266-277
    • /
    • 1995
  • 벼멸구는 촉각 기부의 등쪽으로 알모양의 24ㅐ의 겹눈을 가지고 있다. 벼멸구의 겹눈은 각각의 단안이 분리되어 있고, 각각의 낱눈이 단지 그들의 각막렌즈를 통해서만이 빛을 받는 연립상 겹눈이다. 각각의 낱눈은 큐티클성 각막렌즈와 그 안쪽에 수정체가 자리잡고 있다. 망막세포는 수정체 바로 아래쪽에 자리하며, 이들은 중심축쪽으로 감간소체들이 밀집결합되어 감간체를 형성한다. 감간체는 수정체 말단부분에서 시작되어 기저막에 까지 다달으며, 그 길이는 약 110~120${\mu}m$ 정도이다. 수정체는 4개로 구성된 한쌍의 1차색소세포에 의하여 둘러 쌓여 있으며 이것은 또한 부속색소세포에 의하여 둘러 쌓여 있다. 수정체의 기저부위는 망막세포에 의하여 일부가 둘러 쌓여 있고 망막세포의 내벽에서 발생한 감간소체들로 구성된 감간체와 닿아있다. 낱눈의 상층부분은 7개의 망막세포로 구성되어 있으나 3/4부분에서 8번째의 망막세포가 자리잡고 있다. 중앙부위에 위치하고 있는 감간체는 미세용 모들로 구성된 감간소체들로 구성되어 있는데, 이들 미세융모의 단면도는 6각형의 모양을 가지고 있다. 색소세포는 수정체를 감싸고 있는 1차색소세포, 기저막까지 닿아 있는 부속색소세포, 기저막 부위의 기저막색소세포 등 3가지의 색소세포들이 있다.

  • PDF

옥천대 북서부 태백산지역 평창 일대의 클리페 모델 기반 구조기하 형태 해석 예비 연구 (Preliminary Structural Geometry Interpretation of the Pyeongchang Area in the Northwestern Taebaeksan Zone, Okcheon Belt: A Klippe Model)

  • 이흥기;장이랑;권상훈
    • 자원환경지질
    • /
    • 제56권6호
    • /
    • pp.831-846
    • /
    • 2023
  • 한반도의 대표적인 습곡-단층대 중 하나인 옥천대의 주천-평창지역에는 경기육괴 기반암을 고생대 조선누층군 및 시대미상의 방림층군 상위로 충상시키는 다수의 트러스트 단층이 발달한다. 이 지역의 트러스트들은 상반의 암체가 하반의 암체로 완전히 둘러싸인 폐곡선 형태의 독특한 자취를 보이며, 이는 전형적인 클리페의 지질도 상 특징으로 해석될 수 있다. 특히, 연구 지역과 같이 트러스트 상반에 기반암을 포함하는 클리페의 경우에는 습곡-단층대 배후지의 구조 발달을 이해하는데 중요하다. 그러나 클리페 구조가 잘 정의되기 위해서는 층서적으로 오래된 암체가 트러스트를 경계로 상대적으로 젊은 암체의 상위에 구조적으로 완전히 고립된 형태를 보여야 하기 때문에, 연구지역에 넓게 분포하는 시대미상 방림층군의 지질연대가 매우 중요하다. 본 연구에서는 SHRIMP U-Pb 저어콘 연대측정을 통해 획득한 방림층군의 최대 퇴적시기와 야외조사 결과 및 기존 연구를 종합하여, 방림층군을 아래로는 선캄브리아시대 화강편마암과 위로는 전기 고생대 조선누층군 양덕층군(장산층, 묘봉층)의 지층 사이에 놓이는 고생대 캄브리아기 최하부 지층에 대비하였다. 이를 바탕으로 평창지역에 대한 구조기하 형태 연구를 수행한 결과, 운교리트러스트와 방림트러스트는 하나의 습곡된 트러스트이며 운교리트러스트 상반의 암체들이 하반 암체들에 의해 완전히 고립된 특징을 보이는 클리페 모델로 해석이 가능함을 확인하였다. 향후 주천-평창지역에 대한 구조지질학적 측면의 후속 연구들을 통해 클리페 모델에 대한 추가적인 테스트가 이루어진다면, 옥천대의 구조 진화에 있어서 기반암을 포함하는 변형 기작의 역할에 대해 중요한 정보를 획득할 수 있을 것이다.

부정류 상태에서의 난지도 매립지 침출수 거동 예측 (The Behavior of Leachate on The Transient Condition in The Nanji Waste Landfill)

  • 강동희;조원철;이재영
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제6권2호
    • /
    • pp.57-67
    • /
    • 2001
  • 본 연구는 난지도 매립지에서 기반암 및 풍화대층을 통해서 거동하는 침출수의 속도와 침출수량을 부정류 상태에서 예측하기 위해 실시되었다. 본 연구에서는 3차원 지하수 거동 모델인 MODFLOW와 지하수에 용해되어 있는 오염물질의 확산, 분산, 화학반응 등을 해석할 수 있는 MT3D를 이용하여 안정화 공사 이후 부정류 상태에서 침출수 거동을 해석하였다. 침출수 발생량은 최근 10년간의 기상자료를 이용해서 HELP모델로 산출하였다. 침출수 거동은 차수벽, 차수층 설치 전,후의 침출수위 변화에 의해 예측되었다.

  • PDF

Structural Design of High-Rise Concrete Condominium with Wall Dampers for Vibration Control

  • Tsushi, Takumi;Ogura, Fumitaka;Uekusa, Masahiro;Kake, Satoshi;Tsuchihashi, Toru;Yasuda, Masaharu;Furuta, Takuya
    • 국제초고층학회논문집
    • /
    • 제8권3호
    • /
    • pp.201-209
    • /
    • 2019
  • This paper presents a structural design of the "(Tentative Name) Toranomon Hills Residential Tower" which is currently under construction in Tokyo. The building is a reinforced concrete high-rise residential complex building with 54 stories above ground, 4 basement levels, and a building height of about 220 m. It is a requirement to provide the highest grade of residence in Japan, and in terms of the structural design, it is required to provide wide and comfortable spaces with high seismic performance. These requirements are satisfied by providing a total of 774 vibration control walls of two types. Also, to further improve the structural performance, steel fibers at the rate of 1.0vol% are provided in the ultra-high strength concrete used in the column members.