• 제목/요약/키워드: Base load electricity

검색결과 35건 처리시간 0.019초

전력시장에서 용량요금 메커니즘 변화의 영향과 개선 (A Study on the Amendment of Base Load Market and CP in Electricity Market)

  • 김창수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.255-257
    • /
    • 2007
  • Korea electricity market consists of two payment systems, capacity and energy. Capacity payments are given to the generators according to its hourly availability considering hourly and seasonal weighting factors. Energy payments are settled at the marginal generation cost based on generator variable cost. In 2007, base load energy market is closed and single capacity payment system is begun to apply in electricity market. In this revised market rule, energy price cap for base load generators is newly introduced. We analyze impact of market rule revision in 2007 on base load generators and suggest improvement scheme to enforce market system in this study.

  • PDF

전력산업 경쟁도입에 따른 요금변화에 대한 부하모델수립 (A Study on Load Modeling with respect to the Change of Price in Competitive Electricity Market)

  • 한만형;김정훈;최준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.376-378
    • /
    • 2000
  • The current worldwide electricity market introduced competition, which is breaking up the monopoly structure and also enforcing phased structural reform in South Korea. The change of the electricity charge from cost base to price base due to the introduction of the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Therefore, in order to find a mathematical model of the sensitively-responding-to-price loads and reflect this to the DSM demand management, the price-sensitive load model is needed. Thus, this paper first proposes the composite price-sensitive load model that is expressed as a function of price, presents the methodology to estimate price-sensitive load model at each bus by bus load compositions.

  • PDF

전력산업 경쟁 환경에서의 요금부하모델 수립을 위한 부하기기의 학습곡선 분석 (Analysis on learning curves of end-use appliances for the establishment of price-sensitivity load model in competitive electricity market)

  • 황성욱;김정훈;송경빈;최준영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.386-388
    • /
    • 2001
  • The change of the electricity charge from cost base to price base due to the introduction of the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Besides, it is required the index that consolidate the price volatility experienced on the power exchange with gaming and strategic bidding by suppliers to increase profits. Therefore, in order to find a mathematical model of the sensitively-responding-to-price loads, the price-sensitive load model is needed. And the development of state-of-the-art technologies affects the electricity price, so the diffusion of high-efficient end-uses and these price affect load patterns. This paper shows the analysis on learning curves algorithms which is used to investigate the correlation of the end-uses' price and load patterns.

  • PDF

신기술 보급 및 DSM 정책이 부하기기 학습곡선에 미치는 영향 (The Influence of Introducing New Technologies and DSM Strategies on End-Use Learning Curves)

  • 황성욱;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.435-437
    • /
    • 2001
  • The change of the electricity charge from cost base to price base due to the introduction of the electricity market competition causes consumer to choose a variety of charge schemes and a portion of loads to be affected by this change. Besides, it is required the index that consolidate the price volatility experienced on the power exchange with gaming and strategic bidding by suppliers to increase profits. Therefore, in order to find a mathematical model of the sensitively-responding-to-price loads, the price-sensitive load model is needed. And the development of state-of-the-art technologies affects the electricity price, so the diffusion of high-efficient end-uses and these price affect load patterns. This paper shows the analysis on learning curves algorithms which is used to investigate the correlation of the end-uses' price and load patterns.

  • PDF

가스냉방의 경제성 분석 (An Economic Analysis of the Natural Gas Air-conditioning)

  • 김봉진;박연홍
    • 산업공학
    • /
    • 제11권1호
    • /
    • pp.207-214
    • /
    • 1998
  • Since the natural gas air-conditioning not only increases the base load of the gas company but also decreases the summer peak load of the electricity company, it is considerded as an efficient demand-side management program. This paper suggests the economic evaluation method of the gas air-conditioning program from the perspectives of the participants, the pipeline gas company, the local distribution company, the electricity company, and the total resources. The absorption type gas air-conditioning/space-heating is selected as a case study to illustrate the economic analysis of the natural gas air-conditioning.

  • PDF

금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석 (Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company)

  • 장홍순;한영섭;황익환;서상현
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Electricity Cost Minimization for Delay-tolerant Basestation Powered by Heterogeneous Energy Source

  • Deng, Qingyong;Li, Xueming;Li, Zhetao;Liu, Anfeng;Choi, Young-june
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제11권12호
    • /
    • pp.5712-5728
    • /
    • 2017
  • Recently, there are many studies, that considering green wireless cellular networks, have taken the energy consumption of the base station (BS) into consideration. In this work, we first introduce an energy consumption model of multi-mode sharing BS powered by multiple energy sources including renewable energy, local storage and power grid. Then communication load requests of the BS are transformed to energy demand queues, and battery energy level and worst-case delay constraints are considered into the virtual queue to ensure the network QoS when our objective is to minimize the long term electricity cost of BSs. Lyapunov optimization method is applied to work out the optimization objective without knowing the future information of the communication load, real-time electricity market price and renewable energy availability. Finally, linear programming is used, and the corresponding energy efficient scheduling policy is obtained. The performance analysis of our proposed online algorithm based on real-world traces demonstrates that it can greatly reduce one day's electricity cost of individual BS.

원자력 및 신재생에너지 발전비율에 따른 전력단가의 변화 (Electricity Cost Variations subject to Nuclear and Renewable Power Portions)

  • 고상혁;정범진
    • 에너지공학
    • /
    • 제15권1호
    • /
    • pp.14-22
    • /
    • 2006
  • 원자력발전과 신재생에너지발전에 대하여 과학적, 객관적 검토없이 다양한 정책과 주장이 제기되고 있다. 본 연구에서는 국가별 에너지정책을 조사 분석하고 총 34개의 가능한 전원구성 시나리오를 도출하였다. 이들 시나리오가 우리나라 전력정책에 도입될 경우를 가정하여 전력단가를 계산하였다. 전력단가 계산방법은 현재 우리나라 전력시장에서 사용하는 한계가격결정 방법을 사용하였고 발전원별로 표준건설비 및 운영비를 적용함으로써 계산을 단순화하였다. 계산결과 송배전 비용과 사업자의 이윤을 제외한 현행 전원 구성에 대한 전력단가는 평균 22.18원/kWh이고 전원구성비에 따라 19.74에서 164.07원/kWh까지 분포하였다. 원자력발전비율이 증가할수록 전력단가는 낮아졌고 신재생에너지 발전비율이 증가할수록 전력단가는 높아졌다. 주목할 만한 것은 신재생에너지 발전비율이 20%를 넘어서게 되면 값싼 기저발전을 활용할 수 없게 되어 전력수요가 적은 시간대에 전력단가가 오히려 상승하였다.

Fault Immune Pico-Hydro Powered Base Station of Remote Telecommunication Tower

  • Verma, Vishal;Pant, Peeyush;Singh, Bhim
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1612-1620
    • /
    • 2016
  • This paper presents the dynamic excitation control of a siphon-turbine coupled pico-hydro powered cage rotor induction generator and load matching for off-grid electricity generation. Through the proposed dual-role of the current-controlled voltage source converter (VSC), acting as static synchronous compensator and load controller, real and reactive power are dynamically controlled in a decoupled manner with a self supported DC-bus. The proposed scheme entails minimal computation for ensuring the rated (set) capacity of real power. The scheme also exhibits fault immunity for protection, thus enabling the effective handling of constant power electrical loads presented by base telecom station towers in remote locations. The performance of the system is evaluated under MATLAB/Simulink and is experimented through a developed hardware prototype. Simulation and experimental results show close conformity and validate the effectiveness of the proposed scheme.

한국 전력시장에서의 가스터빈(GT) 발전기 경쟁력 및 시장 미진입 적정성 분석 (Analysis of Gas Turbine Competitiveness and Adequacy of Electricity Market Signal in Korea)

  • 김은환;박용기;박종배;노재형
    • 전기학회논문지
    • /
    • 제66권8호
    • /
    • pp.1172-1180
    • /
    • 2017
  • This study analyzed competition in peak load plants between CCGT and GT instead of competition between base and peak load plants like in previous studies. In common overseas power markets, CCGT and GT claim certain market shares as peak load plants with the latter boasting a high utilization rate as reserve plants. In South Korea, however, there has been no introduction of GT in the market that opened in 2001 with no analysis cases of GT's economy as a peak load plant. The current power market of South Korea is run on the cost-based pool, which allows for no price spikes. Since the capacity payment criteria for compensations for missing money are set based on GT generators, the power market uses GT generators as marginal plants. The purposes of this study were to analyze the competitive edge of GT generators as peak load plants in the domestic power market of South Korea and identify the causes of GT's failure in market entry, thus assessing the adequacy of market signals in the domestic power market.