• Title/Summary/Keyword: Base Rate

Search Result 2,260, Processing Time 0.032 seconds

Creep Properties of Type 316LN Steel Welded by the SAW Method (SAW 법으로 용접된 Type 316LN 강의 크리프 성질)

  • Kim W.G.;Yin S.N.;Ryu W.S.;Yi Won
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.105-106
    • /
    • 2006
  • The creep properties have been evaluated for type 316LN stainless steel welded by the SAW method. The creep tests were conducted with different stress levels for both the base and weld metals at $550^{\circ}C\;and\;600^{\circ}C$. The results of the creep-rupture time of the weld metal did not show a large difference when compared to those of the base one, though it exhibited a little lower value at $600^{\circ}C$. The creep rate of the weld metal was lower than that of the base one at the same stress and rupture-time conditions. The creep-rupture ductility of the weld metal is found to be decreased by about 60%, compared to the base one. This is due to the decreasing of tensile elongation and the increasing of the yield stress in the weld metals.

  • PDF

A Study on the Incidence of Carbon Monoxide Poisoning (연탄(煉炭)가스중독(中毒)의 발생실태(發生實態)에 관(關)한 연구(硏究))

  • Cho, Soo-Hun;Shin, Young-Soo;Lee, Doek-Hyoung;Kim, Yong-Ik;Yun, Dork-Ro
    • Journal of Preventive Medicine and Public Health
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 1985
  • A decade ago a survey on the population-base incidence rate of anthracite coal gas (mainly carbon monoxide) poisonig in Seoul area was investigated, resulting in the incidence rate of 306/10,000 risk population and 1 death/10,000. Another survey on the carbon monoxide poisoning was investigated during 1 year period from Apr. 1983 to Mar. 1984. Total subjects of risk population were 67,740 households covering 353,287 persons. The major findings of this survey are as follows: 1. Household-base incidence rate was 8.4% spell-base 10.4%. 2. The incidence rate was the highest in houses having each of slate roof, cement wall, vinyl floor of bedroom and direct 'ondol' heating system. 3. Average 2.1 person was attacked from one incidence of the poisoning; severity-wise person-base incidence rates per 10,000 were 352 in mild poisoning, 54 in severe poisoning and 1.4 in death-overall incidence rate 407. Several facts were identified which supported that this figure was moderately underestimated. As the incidence of the poisoning is affected by socioeconomic and environmental factors, it is natural that one expects the incidence will decrease in proportion to genernal improvement of the above factors. Thus the results of these two surveys seemed preposterous. But further study suggested that the incidence rate (306/10,000) decade before had been significantly underestimated and corrected-rate should have been 478/10,000 level. 4. Age and sex distribution by the degree of the poisoning was uniform with little statistical difference; overall incidence rates by sex were 339/10,000 in male and 475/10,000 in female with significant statistical difference(p<.01). 5. 5.3% of the patients were treated at hospital or local clinic; 3.0% of the patients were hospitalized. Admission rate in comatose patient(severe poisoning) was 14.2%. In conclusion, carbon monoxide poisoning remains a major health problem by now.

  • PDF

A Fundamental Study on the Consistency of Base Concrete Influencing on the Worability and Engineering Properties of Folwing Concrete (유동화콘크리트의 시공성 및 공학적 특성에 미치는 베이스콘크리트의 시공연도에 관한 기초적 연구)

  • 김무한;송하영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.04a
    • /
    • pp.1-6
    • /
    • 1992
  • The objective of this report is to investigate and analyze the influnce of the different base concrete in consistency for the good production of superplasticized concrete (SPC) on the basis of the experimental results. The principal conclusions are summarized as follows. 1. SPC exhibited only slight bleeding in both cases of low and medium consistency of the base concrete, compared to the conventional concrete, compared to the coventional concrete. 2. SPC lost slump and flow value at a much faster rate than the conventional concrete with an equivalent water/cement ratio and initial consistency. 3. The compressive strength of SPC was fount to be higher than that of base and conventional concrete, and the case of base concrete with medium consistency showed a little more incretment than low consistency

  • PDF

Dendrite Arm Spacing and Carbide Morphology with Thermal Gradient and Solidification Rate in Directionally Solidified Ni-Base Superalloy (일방향 초내열합금에서 응고속도 및 온도구배 따른 수지상간격 및 탄화물 형상 변화)

  • Son, S.D.;Kim, Y.H.;Choi, G.S.;Lee, J.H.;Seo, S.M.;Jo, C.Y.
    • Journal of Korea Foundry Society
    • /
    • v.27 no.2
    • /
    • pp.77-82
    • /
    • 2007
  • The effects of thermal gradient and solidification rate on the dendrite arm spacing and carbide morphology were investigated in directionally solidified Ni-base superalloy, CM 247LC. Thermal gradient was controlled by changing the position of the cold chamber and the furnace set temperature. The interface morphology changed from the planar to dendritic as increasing solidification rate. It was found that the dendrite spacing decreased as increasing the thermal gradient as well as the solidification rate. Also, as increasing solidification rate, carbide morphology changed from blocky shape to script and spotty shapes.

Primary Water Stress Corrosion Crack Growth Rate Tests for Base Metal and Weld of Ni-Cr-Fe Alloy (니켈 합금 모재 및 용접재의 일차수응력부식균열 균열성장속도 시험)

  • Lee, Jong Hoon
    • Corrosion Science and Technology
    • /
    • v.18 no.1
    • /
    • pp.33-38
    • /
    • 2019
  • Alloy 600/182 with excellent mechanical/chemical properties have been utilized for nuclear power plants. Although both alloys are known to have superior corrosion resistance, stress corrosion cracking failure has been an issue in primary water environment of nuclear power plants. Therefore, primary water stress corrosion crack (PWSCC) growth rate tests were conducted to investigate crack growth properties of Alloy 600/182. To investigate PWSCC growth rate, test facilities including water chemistry loop, autoclave, and loading system were constructed. In PWSCC crack growth rate tests, half compact-tension specimens were manufactured. These specimens were then placed inside of the autoclave connected to the loop to provide primary water environment. Tested conditions were set at temperature of $360^{\circ}C$ and pressure of 20MPa. Real time crack growth rates of specimens inside the autoclave were measured by Direct Current potential drop (DCPD) method. To confirm inter-granular (IG) crack as a characteristic of PWSCC, fracture surfaces of tested specimens were observed by SEM. Finally, crack growth rate was derived in a specific stress intensity factor (K) range and similarity with overseas database was identified.

Fault Tolerant Processor Design for Aviation Embedded System and Verification through Fault Injection (항공용 임베디드 시스템을 위한 고장감내형 프로세서 설계와 오류주입을 통한 검증)

  • Lee, Dong-Woo;Ko, Wan-Jin;Na, Jong-Wha
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.2
    • /
    • pp.233-238
    • /
    • 2010
  • In this paper, we applied the forward and backward error recovery techniques to a reduced instruction set computer (risc) processor to develop two fault-tolerant processors, namely, fetch redundant risc (FRR) processor and a redundancy execute risc (RER) processor. To evaluate the fault-tolerance capability of three target processors, we developed the base risc processor, FRR processor, and RER processor in SystemC hardware description language. We performed fault injection experiment using the three SystemC processor models and the SystemC-based simulation fault injection technique. From the experiments, for the 1-bit transient fault, the failure rate of the FRR, RER, and base risc processor were 1%, 2.8%, and 8.9%, respectively. For the 1-bit permanent fault, the failure rate of the FRR, RER, and base risc processor were 4.3%, 6.5%, and 41%, respectively. As a result, for 1-bit fault, we found that the FRR processor is more reliable among three processors.

Accelerated Aging Characteristics of a Double Base Propellant (복기추진제의 가속 노화 특성 연구)

  • Go, Cheongah;Park, Youngchul;Seo, Taeseok;Moon, Youngtaek;Kim, Junhyung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.23 no.4
    • /
    • pp.61-69
    • /
    • 2019
  • Accelerated aging test for the double base propellant was carried out at three different temperatures (60, 70, and $75^{\circ}C$) for over a year. To evaluate the aging characteristics of the double base propellant, the stabilizer contents and thermal decomposition kinetics were analyzed by using high performance liquid chromatography (HPLC) and AKTS-Thermokinetics software. As a result, stabilizer contents in the double base propellant gradually decreased according to the aging temperature and aging duration. The consumption rate of 2-NDPA in the accelerated aged propellants showed that it was two times faster at $75^{\circ}C$ in compared with ther rate at $70^{\circ}C$. These experimental values were simulated by the SB kinetic model, and it was shown that the two-step model with constant reaction orders n1=1 and n2=0 best describes the process of the stabilizer depletion for the double base propellant.

Surgical Strategy for Skull Base Chordomas : Transnasal Midline Approach or Transcranial Lateral Approach

  • Wang, Benlin;Li, Qi;Sun, Yang;Tong, Xiaoguang
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.3
    • /
    • pp.457-468
    • /
    • 2022
  • Objective : The clinical management paradigm of skull base chordomas is still challenging. Surgical resection plays an important role of affecting the prognosis. Endonasal endoscopic approach (EEA) has gradually become the preferred surgical approach in most cases, but traditional transcranial surgery cannot be completely replaced. This study presents a comparison of the results of the two surgical strategies and a summary of the treatment algorithms for skull base chordomas. Methods : We retrospectively analyzed the surgical outcomes and follow-up data of 48 patients with skull base chordomas diagnosed pathologically who received transnasal midline approaches (TMA) and transcranial lateral approaches (TLA) from 2010 to 2020. Results : Among the 48 patients, 36 cases were adopted TMA and 12 cases were performed with TLA. In terms of gross total resection (GTR) rate, 27.8% in TMA and 16.7% in TLA and with EEA alone it was increased to 38.9%, while 29.7% in primary surgery. In TMA, the cerebrospinal fluid (CSF) leak remains the most common complication (13 cases, 36.1%), other main complications included death, cranial nerve palsy, hypopituitarism, all the comparisons were no statistical significance. The Karnofsky Performance Scale scores in TMA were all better than those in TLA at different time, and the overall survival (OS) and recurrence free survival/progression free survival was just the reverse. Conclusion : The EEA for skull base chordomas resection has improved the GTR rate, but transcranial approach is still an alternative approach. It is necessary to select an appropriate surgical approach based on the location and the pattern of tumor growth in order to obtain the best surgical outcomes.

Analysis on Improving Power of Thermal Radiation Shield in Low Pressure Chamber of AMTEC (AMTEC내 저압용기에서의 열복사차단막 형상에 따른 발전량 향상 해석)

  • Chung, Won-Sik;Chi, Ri-Guang;Lee, Wook-Hyun;Lee, Kye-Bock;Rhi, Seok-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.54-62
    • /
    • 2016
  • The most efficient system for converting heat to electricity, AMTEC (Alkali Metal Thermal-to-Electric Convertor), is a device that directly converts heat energy to electricity using an alkali metal (sodium) as the working fluid. The AMTEC consists of a low pressure chamber, high pressure chamber, BASE (Beta-Alumina Solid Electrolyte), and artery wick. The main heat loss of the AMTEC system occurs in the low pressure chamber. A high power generation rate is thought to be obtainable by using a high temperature in the BASE. Therefore, to reduce the radiation heat loss, 6 types of radiation shields were examined to reduce the radiative heat loss in the low pressure chamber. The power generation rate of the AMTEC varied depending on the shape of the radiation shield. CFD (Computational Fluid Dynamics) analyses were carried out to optimize the shape of the radiation shield. As a result, the optimum radiation shield was found to consist of a curvature formed at the vertical point, in which case the dimensionless temperature (condenser temperature/BASE temperature) is approximately 0.665 and the maximum power generated is calculated to be 17.69W. Increasing the distance beween the BASE and condenser leads to an increase in the power generated, and the power generated with the longest distance was 17.58 W. The shields with multiple holes and multiple horizontal layers showed power reduction rates of 0.91 W and 2.06 W, respectively.

Physical Properties of Yukwa Base According to the Extrusion Processing Conditions (I): Manufacturing of Yukwa Base with Combination of Glutinous Rice Flour and Rice Flour (Extrusion 제조조건에 따른 유과바탕의 물리적 품질특성(I): 찹쌀가루와 쌀가루 배합에 따른 유과바탕의 제조)

  • Eun, Jong-Bong;Hsieh, Fu-hung;Choi, Ok-Ja
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.12
    • /
    • pp.1760-1766
    • /
    • 2009
  • Physical properties of Yukwa base extruded with glutinous rice flour, rice flour, defatted soy flour, and salt using an twin-screw extruder were investigated. The ingredients were extruded at various moisture contents (16-18%), screw speeds (300 & 400 rpm) at 43.4 kg/hr feed rate. Length and specific volume of Yukwa base increased with decreasing moisture contents. Hunter's color L* values of Yukwa base was higher whereas $a^*\;and\;b^*$ values were lower with increasing moisture content. Water absorption index of Yukwa base increased with increasing moisture contents. X-ray diffraction of Yukwa base showed B type moisture content of 16% and 17% while it showed A type moisture content of 18%. Degree of crystallinity and breaking strength of Yukwa base were the lowest in the moisture content of 16% while the lowest value for hardness was found in the moisture content of 16% and of 17% with screw speed 400 rpm for all samples. In the microstructure of cross section of Yukwa base, air cell size was larger and cell wall was thicker as moisture content increased. The sensory evaluation of the Yukwa base showed that color and flavor were not significantly different among samples, while taste, appearance, mouth feel, and overall preference were higher as moisture contents decreased.