• 제목/요약/키워드: Base Rate

검색결과 2,262건 처리시간 0.03초

오스테나이트 스테인리스강 용접부의 응력부식 거동에 미치는 용접 방법의 영향 (The effect of welding methods on the stress corrosion behavior of the welded austenitic stainless steel)

  • 백신영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제19권4호
    • /
    • pp.42-50
    • /
    • 1995
  • To study the effect of welding methods on the Stress Corrosion Cracking (SCC) behavior of welded AISI type 316L and 304 austenitic stainless steel, the Slow Strain Rate Technique(SSRT) has been adopted in the boiling 45 wt% $MgCl_2$ solution. The results are as follows. 1) Welded sections are more susceptible than base metal in SCC, and the rank of SCC, and the rasistance in welding method is TIG, MIG, $CO_2$ and ARC. 2) The Ultimate tensile strength(UTS) and the strain of both base metal and welded joint are reduced as decreasing extension rate. 3) The SCC resistance of 316L base metal and welded sections are superior than that of 304. 4) The tendency of pitting and the SCC suseptibility are agreed well, and the SCC site is welded deposit section in 316L whereas HAZ in 304.

  • PDF

아세트아미노펜 좌제의 용출과 직장흡수 (Dissoultion and Rectal Absorption of Acetaminophen from Suppositories)

  • 한정선;심창구;김신근
    • 약학회지
    • /
    • 제31권5호
    • /
    • pp.286-295
    • /
    • 1987
  • The relationship between in vitro release and in vivo bioavailability of acetaminophen from suppositories was investigated. Effect of glycyrrhizin on the drug release and rectal absorption in rats was also examined. Suppositories containing 25mg of acetaminophen were prepared with Wecobee FS (fatty base) or PEG (water-soluble base) bases. The release from the suppositories were determined with USP rotating basket dissolution apparatus and with the suppository release tester. The temperature of the dissolution medium was very critical for the dissolution of acetaminophen from Wecobee FS suppositories. The bioavailability of acetaminophen was calculated from the plasma concentration-time curve after rectal administration of the suppositories to the rats. There were no significant differences in AUC following rectal administration of Wecobee FS and PEG suppositories, but the release and absorption from the Wecobee FS suppositories were faster than those from PEG suppositories. The dissolution rate obtained by the suppository release tester was better correlated with in vivo absorption rate constant than that by the USP dissolution apparatus. It suggests that the partitioning between rectal fluid and suppository base is the rate-limiting step in the rectal absorption of acetaminophen from suppositories. Glycyrrhizin was found not to affect in vitro dissolution and rectal absorption of acetaminophen.

  • PDF

Vacuum Characteristic of a Chamber Made of Mild Steel

  • Park, Chongdo;Ha, Taekyun;Cho, Boklae
    • Applied Science and Convergence Technology
    • /
    • 제24권4호
    • /
    • pp.84-89
    • /
    • 2015
  • The base pressure and outgassing rate of a mild steel chamber were measured and compared to those of a stainless steel chamber. A combined sputter-ion and non-evaporable getter pump with a nominal pumping speed of 490 l/s generated the base pressure of $2.7{\times}10^{-11}$ mbar in the mild steel chamber and $1.2{\times}10^{-10}$ mbar in the stainless steel chamber. The rate-of-rise measurements show that the mild steel has an extremely low outgassing rate of $2.6{\times}10^{-13}$ mbar $ls^{-1}cm^{-2}$, which is about one-order of magnitude smaller than the outgassing rate of the stainless steels. Vacuum annealing of the mild steel at $850^{\circ}C$ reduced the outgassing rate further to $8.8{\times}10^{-14}$ mbar $ls^{-1}cm^{-2}$, which was comparable to the outgassing rate of a heat treated stainless steel for extreme-high vacuum use.

국소의치상을 위한 연성 이장재사용시 교합압에 따른 의치상 변위(Displacement)량 비교 (A STUDY ON DIFFERENT AMOUNT OF DENTURE BASE DISPLACEMENT USING SOFT DENTURE RELINING MATERIAL UNDER MASTICATORY FORCE)

  • 이호용
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.18-25
    • /
    • 1998
  • The purpose of this study was to determine how to use soft relining material by observing an amount of denture displacement according to the different base area of residual ridge and thickness of soft relining material under masticatory force. Stone models that simulated residual ridge were made with different amount of denture base area and denture was fabricated by conventional heat curing resin with usual manner on the model and relined by silicone type soft relining material with different thickness. Specimen was examined the amount of denture displacement by Instron within range of normal occlusal force. The results were as following : 1. The increasing rate of denture displacement was higher than that of soft relining material thickness. 2. The amount of denture displacement decreased 1.7 times when base area became double at same thickness of soft relining material 3. The increasing rate of denture displacement was higher than that of occlusal force

  • PDF

이종재료 용접부의 피로균열진전 특성 (Fatigue Crack Growth Characteristics on The Weld Joint of Bimaterial)

  • 권재도;김우현;박중철;배용탁;김중형
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1997년도 특별강연 및 추계학술발표 개요집
    • /
    • pp.81-85
    • /
    • 1997
  • This paper was conducted the fatigue crack growth test on the base metal and weld joint of bimaterial(carbon-stainless steel), carbon steel and stainless steel. As the result, the fatigue crack growth rate of weld joint on the stainless-stainless steel is faster than stainless base metal, and weld joint on the carbon-carbon steel heat affected zone is slower than carbon base metal. And fatigue crack growth rate of carbon-stainless steel weld joint and heat affected zone is similar to the behavior of stainless base metal. In conclusion, weld joint of bimaterial is stable in the fatigue crack growth behavior.

  • PDF

통계적 기법을 이용한 화자변화 검출 실험 (A Speaker Change Detection Experiment that Uses a Statistical Method)

  • 이경록;김진영
    • 음성과학
    • /
    • 제8권4호
    • /
    • pp.59-72
    • /
    • 2001
  • In this paper, we experimented with speaker change detection that uses a statistical method for NOD (News On Demand) service. A specified speaker's change can find out content of each data in speech if analysed because it means change of data contents in news data. Speaker change detection acts as preprocessor that divide input speech by speaker. This is an important preprocessor phase for speaker tracking. We detected speaker change using GLR(generalized likelihood ratio) distance base division and BIC (Bayesian information criterion) base division among matrix method. An experiment verified speaker change point using BIC base division after divide by speaker unit using GLR distance base method first. In the experimental result, FAR (False Alarm Rate) was 63.29 in high noise environment and FAR was 54.28 in low noise environment in MDR (Missed Detection Rate) 15% neighborhood.

  • PDF

수리가능한 군수품의 여유재고수준 결정기법 (The Method of Determinating the Spare Inventory Level in the Repairable Munition System)

  • 유형근;김만식;김종수
    • 한국국방경영분석학회지
    • /
    • 제16권2호
    • /
    • pp.96-104
    • /
    • 1990
  • This paper concerns the problem of deciding the rational spare inventory levels for efficient use of a limited defence budget and, at the same time, for enhancing the operation rate of equipement/weapons in the army. The system we are concerned has a finite number of repairmen at each base and the depot. After repair job has completed, the repaired items are returned to the base where they have originated. For the system, we identify the distribution of the total number of failed items which belong to a base and develope a method to find spare inventory levels of repairable items at each base to satisfy a specified minimum fill rate.

  • PDF

Ni 기 초합금 급냉응고 리본의 미세구조와 고온 인장특성에 관한 연구 (A Study on the Microstructures and High Temperature Tensile Properties of Ni-base Superalloy Melt-Spun Ribbons)

  • 한창석
    • 열처리공학회지
    • /
    • 제27권4호
    • /
    • pp.180-184
    • /
    • 2014
  • In order to make clear relationship between high temperature tensile properties and fine microstructure of rapidly solidified cast-type Ni-base superalloys without heat treatment required for consolidation process, tensile test was carried out by changing strain rate from $5{\times}10^{-5}s^{-1}$ to $2{\times}10^{-2}s^{-1}$ and test temperature from $900^{\circ}C$ to $1050^{\circ}C$ using IN738LC and Rene'80 melt-spinning ribbons by twin roll process which were superior to ribbons by single roll process from the viewpoint of structure homogeneity. The dependence of tensile strength on strain rate and test temperature was studied and strain rate sensitivity, m, were estimated from tensile test results. From this study, it was found that tensile strength was influenced by ${\gamma}^{\prime}$ particle diameter, test temperature and strain rate, and m of ribbons exhibited above 0.3 over $950^{\circ}C$.

총의치 환자에 있어 Permanent record base를 이용한 악간관계 기록 (JAW RELATION WITH PERMANENT RECORD BASES IN THE EDENTULOUS PATIENTS)

  • 허윤석;신상완
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.231-239
    • /
    • 1995
  • When the complete denture is made, the record base for jaw relation is divided into temporary record base and permanent record base. However, The temporary record base include some disadvantages such as, the lackness of intimate contact between model and base, the lackness of retention during the jaw relation registration, When we obtained jaw relation the permanent record bases made from heat curing resin were utilized. We could get several advantages as follows : 1. The permanent record base provided intimate contact between the model and record base. 2. In fabricating occlusal rim on record base, the dimensional change of record base was little because the permanent record base was lesser influenced to thermal change of occlusal rim than the temporary record base. 3. At the stage of jaw relation, the retention of final denture could be early checked. 4. It could be able to get more accurate registration of jaw relation because all procedure were done on the same base during the jaw relation, artificial teeth arrangement, try-in, and final denture construction. 5. Although there was an inconvenience due to double curing procedure, the shrinkage rate in resin polimerization was relatively reduced so that more dimensional stability could be taken.

  • PDF

비열플라즈마를 이용한 CF4 분해에 미치는 혼합가스의 영향 (Effect of Mixed Gases on Decomposition Characteristic of CF4 by Non-Thermal Plasma)

  • 박재윤;정장근;김종석;임근희
    • 한국전기전자재료학회논문지
    • /
    • 제15권6호
    • /
    • pp.543-550
    • /
    • 2002
  • In this paper, the $CF_4$ decomposition rate and by-product were investigated for two simulated plasma reactors which are metal particle reactor and spiral wire reactors as a function of mixed gases. The $CF_4$ decomposition rate by plasma reactor with metal particle electrode had a gain of 20~25% over that by plasma reactor with spiral wire electrode. The $CF_4$ decomposition efficiency increases with increasing applied voltage up to the critical voltage for spark formation. The $CF_4$ decomposition efficiency of metal particle reactor was about 80% at AC 24kV. The $CF_4$ decomposition rate used Ar-$N_2$ as base gas was the highest among three base gases of $N_2$, $Ar-N_2$, air. The by-products of the $N_2$, $N_2Ar$ base as were similar, but in case of air base they were different.