• Title/Summary/Keyword: Base Frame

Search Result 583, Processing Time 0.024 seconds

A Study on the Structural Strength of the Rolling Stock Seat Frame (유한요소해석을 이용한 철도차량 시트프레임의 정적 강도 평가에 관한 연구)

  • Koo, Jeong-Seo;Cho, Hyun-Jik
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.49-58
    • /
    • 2003
  • In this paper, the structural strengths of a rolling stock seat were numerically evaluated under several design load conditions based on the UIC requirements. The rolling stock seat was designed for the high speed train of a Chinese conventional line. To maximize its weight reduction and structural strength, some aluminium alloys like 6N01-T5 and ALDC8-T5 were applied to the base frame, side frame and armrest. The designed seat frame satisfied the strength requirements on inertia loads due to accelerations, and fatigue test conditions. However, it violated the requirements on the static test of UIC 566 OR. Some design modifications were suggested and numerically evaluated to satisfy the static test requirements.

  • PDF

Self-centering passive base isolation system incorporating shape memory alloy wires for reduction in base drift

  • Sania Dawood;Muhammad Usman;Mati Ullah Shah;Muhammad Rizwan
    • Smart Structures and Systems
    • /
    • v.31 no.5
    • /
    • pp.531-543
    • /
    • 2023
  • Base isolation is one of the most widely implemented and well-known technique to reduce structural vibration and damages during an earthquake. However, while the base-isolated structure reduces storey drift significantly, it also increases the base drifts causing many practical problems. This study proposes the use of Shape Memory Alloys (SMA) wires for the reduction in base drift while controlling the overall structure vibrations. A multi-degree-of-freedom (MDOF) structure along with base isolators and Shape-Memory-Alloys (SMA) wires in diagonal is tested experimentally and analytically. The isolation bearing considered in this study consists of laminates of steel and silicon rubber. The performance of the proposed structure is evaluated and studied under different loadings including harmonic loading and seismic excitation. To assess the seismic performance of the proposed structure, shake table tests are conducted on base-isolated MDOF frame structure incorporating SMA wires, which is subjected to incremental harmonic and historic seismic loadings. Root mean square acceleration, displacement and drift are analyzed and discussed in detail for each story. To better understand the structure response, the percentage reduction of displacement is also determined for each story. The result shows that the reduction in the response of the proposed structure is much better than conventional base-isolated structure.

Seismic Evaluation of Ordinary Moment Concrete Frames Using Capacity Spectrum Method (지반특성과 지진지역에 따른 보통모멘트 골조의 내진성능 평가)

  • 권건업;한상환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.947-952
    • /
    • 2001
  • This study is to evaluate seismic performance of ordinary moment concrete frames. Base shear and roof displacement relations are obtained from the experiment of 3 story ordinary moment resisting concrete frame. The frame was designed only for gravity loads. The performance of the building is evaluated using capacity spectrum method. Five different seismic zones and three different soil types are considered. For each condition of seismic zone and soil type, ten earthquake ground motions are used to establish the demand spectrum.

  • PDF

A Study on guidance System for Workstation Using AI Techniques (인공지능 기법을 이용한 워크스테이션 조작지사용 S/W 개발에 관한 연구)

  • Young Sum Kim
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.2
    • /
    • pp.168-175
    • /
    • 1988
  • This paper describes a User guidance System aimed for user-friendly workstation guider that extracts Conceptual Structure from the input sentence by use of CE theory and performs Question Answering in Teletex Manual domain. It uses Frame typed knowledge base and CD recognizer as link procedure between CE structure and Frame controller.

  • PDF

A Study on MAC Protocol for Packet Data Services in Next-Generation Wireless Networks (차세대 무선망에서 패킷 데이터 서비스를 위한 MAC 프로토콜 연구)

  • 임인택
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.6
    • /
    • pp.1115-1120
    • /
    • 2004
  • In this paper, a CSSMA/AI MAC protocol for data services in packet CDMA network is presented. The main features of this protocol are the code status sensing and code reservation for reducing the packet collision. The base station broadcasts the code status on a frame-by-frame basis just before the beginning of each preamble transmission, and the mobile station transmits a preamble for reserving a randomly selected code based on the received code status. After having transmitted the preamble, the mobile station listens to the downlink of the selected code and waits for the base station reply. If this reply indicates that the code has been correctly acquired, it continues the packet transmission for the rest of the frame. If there are other packets waiting for transmission, the base station broadcasts the status of the code as reserved, and the mobile station transmits a packet on a reserved code for the successive frames.

Development of Cutting Jig using Separation of PCB component (PCB소자 분리용 컷팅지그 개발)

  • Lee, Seung-Chul;Park, Suk-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2567-2572
    • /
    • 2014
  • In the present study, we aimed to obtain multi jig that PCB sheet with several PCB component can cut in a short time as to the Separation of PCB component. PCB supporter designed safely at the base frame and each model can be separable. it completed the neodium magnet for the fixing of the upper part laser transmission hole of the both. One of the development, the cutting working with one base frame which PCB component of various standard, fixing of module and bridge connected to PCB component could be possible. and it reduced the inconvenience which has to replace the base frame and PCB sheet fixed member. It compared to other press up about 70% of accuracy and a reduction in investment cost was about 400%.

Influence of Column Base Rigidity on Behavior of Steel Buildings (강구조물 지지부의 강성도가 구조물 거동에 미치는 영향)

  • 권민호;박문호;장준호;박순응
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.1
    • /
    • pp.165-172
    • /
    • 2002
  • Generally, the steel rigid frame has been analyzed using finite element analysis tools. While many efforts have been poured into the understanding and accurate prediction for the nonlinear behavior of the columns and beam-columns connections, the base of the columns are modeled as simply hinged or fixed. However, the base of the steel columns practically is neither fixed not hinged. It behaves as semi-rigid. In this paper, the supports of the columns we modeled as semi-rigid and the importance of such approach in moment-resisting columns is evaluated. Two typical buildings designed by the US specification are modeled and analyzed by the finite element based on stiffness method and flexibility method. The column bases of three-story buildings are modeled as rotational springs with a varying degree of stiffness and strength that simulates the semi-rigidity of the base. Depending on the degree of stiffness and strength, the semi-rigidity varies from the hinged to the fixed. Buildings with semi-rigid column bases behaves similarly to the building with fixed bases. It has been numerically observed through the pushover and nonlinear time history analyses that the decrease of the stiffness of the column base induces the rotational demand on the int air beams. an increase of rotation demands on the first store connections and lead to a soft-story mechanists Due often to the construction and environmental effects, undesired reduction of column base stiffness may cause an increase of rotation demands on the first store connections and lead to a soft-story mechanism.

Finite Element Modeling and Nonlinear Analysis for Seismic Assessment of Off-Diagonal Steel Braced RC Frame

  • Ramin, Keyvan;Fereidoonfar, Mitra
    • International Journal of Concrete Structures and Materials
    • /
    • v.9 no.1
    • /
    • pp.89-118
    • /
    • 2015
  • The geometric nonlinearity of off-diagonal bracing system (ODBS) could be a complementary system to covering and extending the nonlinearity of reinforced concrete material. Finite element modeling is performed for flexural frame, x-braced frame and the ODBS braced frame system at the initial phase. Then the different models are investigated along various analyses. According to the experimental results of flexural and x-braced frame, the verification is done. Analytical assessments are performed in according to three dimensional finite element modeling. Nonlinear static analysis is considered to obtain performance level and seismic behaviour, and then the response modification factors calculated from each model's pushover curve. In the next phase, the evaluation of cracks observed in the finite element models, especially for RC members of all three systems is performed. The finite element assessment is performed on engendered cracks in ODBS braced frame for various time steps. The nonlinear dynamic time history analysis accomplished in different stories models for three records of Elcentro, Naghan and Tabas earthquake accelerograms. Dynamic analysis is performed after scaling accelerogram on each type of flexural frame, x-braced frame and ODBS braced frame one by one. The base-point on RC frame is considered to investigate proportional displacement under each record. Hysteresis curves are assessed along continuing this study. The equivalent viscous damping for ODBS system is estimated in according to references. Results in each section show the ODBS system has an acceptable seismic behaviour and their conclusions have been converged when the ODBS system is utilized in reinforced concrete frame.

Lightweight design for windlass base frame using optimal design technique (최적 설계 기법을 적용한 Windlass base frame의 경량화 설계)

  • Songr, Ju-Han;Pack, Min-Hyuk;Kang, Han-Bin;Pack, In-Seok;Lee, Dong-Wook;Lee, Gye-Gwang;Lee, Seok-Soon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.477-483
    • /
    • 2013
  • The widlass base frame which is currently used is designed by lots of volume and costs so as to obtain high rigidity in spite of the greatly external load. The purpose of this research is to draw conceptual design of optimal design which can satisfy high rigidity existing windlass base frame has and lessening the body at the same time. Therefore, it progressed conceptual design by applying Topology optimization and Size optimization based on the finite-element analysis for the early model and indicated the result by comparing the early model with optimized model. As the result of Topology optimization, its stress was increased by about 6MPa and weight was decreased by about 560kg in comparison with the early model. In addition, in case of Size optimization, its stress was increased by about 7MPa and weight was decreased by about 1,560kg in comparison with the early model.

Performance-based framework for soil-structure systems using simplified rocking foundation models

  • Smith-Pardo, J. Paul
    • Structural Engineering and Mechanics
    • /
    • v.40 no.6
    • /
    • pp.763-782
    • /
    • 2011
  • Results from nonlinear time-history analyses of wall-frame structural models indicate that the condition of vulnerable foundations -for which uplifting and reaching the bearing capacity of the supporting soil can occur before yielding at the base of the shear walls- may not be necessarily detrimental to the drift response of buildings under strong ground motions. Analyses also show that a soil-foundation system can inherently have deformation capacity well in excess of the demand and thus act as a source of energy dissipation that protects the structural integrity of the shear walls.