• Title/Summary/Keyword: Barbed Suture

Search Result 7, Processing Time 0.022 seconds

Cadaveric Feasibility Study of Knotless Barbed Suture for Tracheal Anastomosis in Dogs

  • Hyeon-Ah Min;Chang-Hwan Moon;You-Jeong Jeong;Hae-Beom Lee;Dae-Hyun Kim;Seong Mok Jeong
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.311-318
    • /
    • 2022
  • Appropriate suture technique is crucial for successful tracheal anastomosis. However, standards for an ideal suture method have not yet been established. A previous study suggested tracheal anastomosis using barbed sutures that do not require knots; however, their use in small animals has not been reported. In this study, we aimed to compare knotless barbed sutures with conventional smooth sutures in terms of maximum tensile strength and suturing time in canine tracheal models to demonstrate the feasibility of using barbed sutures in tracheal anastomosis in dogs. Tracheal segments harvested from nine beagle dog cadavers were randomly assigned to three suture groups: barbed suture (B), smooth suture in simple interrupted pattern (SI), and smooth suture in simple continuous pattern (SC). The maximum tensile force and suturing time were compared according to the suturing method, and the mode of failure was evaluated. The average suturing time was 3.29 min in the B group; 4.41 min, SC group; and 8.99 min, SI group (p < 0.001). The average maximum tensile force in the SC group was 134.97 N, which was stronger than the SI (110.57 N) and B groups (103.10 N) (p < 0.05 and p < 0.01, respectively). The difference between the B and SI groups was not significant (p = 0.05). The B group demonstrated comparable mechanical strength and shorter suture time compared with the SI group. Therefore, tracheal anastomosis using barbed sutures could be an effective alternative to conventional smooth sutures in dogs.

Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

  • Colak, Ozlem;Kankaya, Yuksel;Sungur, Nezih;Ozer, Kadri;Gursoy, Koray;Serbetci, Kemal;Kocer, Ugur
    • Archives of Plastic Surgery
    • /
    • v.46 no.3
    • /
    • pp.228-234
    • /
    • 2019
  • Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

Feasibility of Use of a Barbed Suture (V-Loc 180) for Quilting the Donor Site in Latissimus Dorsi Myocutaneous Flap Breast Reconstruction

  • Thekkinkattil, Dinesh Kumar;Hussain, Tasadooq;Mahapatra, Tapan Kumar;McManus, Penelope Louise;Kneeshaw, Peter John
    • Archives of Plastic Surgery
    • /
    • v.40 no.2
    • /
    • pp.117-122
    • /
    • 2013
  • Background Latissimus dorsi (LD) myocutaneous flap is a popular method of breast reconstruction which can be associated with high incidence of seroma formation. Quilting sutures at the harvest site are used to reduce this. Barbed sutures are self anchoring sutures which avoid multiple knotting and can be useful in quilting. Methods A retrospective analysis of prospectively maintained database of patients who underwent LD flap breast reconstruction between January 2009 and January 2011 was carried out. Seroma formation at the harvest site, wound related complications, inpatient stay and duration of surgery were analysed and a comparison was made between two groups where quilting was done with barbed (V-Loc) suture and conventional polydioxanone (PDS) II sutures. Results Fifty-seven patients were included of which 33 had quilting by V-Loc sutures and in 24 patients PDS II suture was used. Median age in the PDS group was 55 years (interquartile range [IQR)], 45 to 61 years) which was comparable to the V-Loc group (53 years [IQR, 48 to 59 years]; P-value 0.948). Sixteen patients (28%) had significant seroma formation and 5 (9%) patients developed superficial wound dehiscence. Incidences of seroma or wound complications were comparable (P-value 0.378 and 1.00, respectively). Secondary outcomes such as total duration of surgery, total inpatient stay, total amount of drain at the donor site were also similar in two groups. Conclusions Use of barbed sutures for quilting the donor site in LD flap reconstruction is a feasible option and the associated seroma formation and wound complications are comparable with conventional sutures.

Use of a Barbed Suture Tie-Over Technique for Skin Graft Dressings: A Case Series

  • Joyce, Kenneth M.;Joyce, Cormac W.;Mahon, Nicola;Kelly, Jack L.
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.341-345
    • /
    • 2015
  • Background A tie-over dressing is the accepted method to secure skin grafts in order to prevent haematoma or seroma formation. We describe the novel application of a barbed suture tie-over for skin graft dressing. The barbs act as anchors in the skin so constant tensioning of the suture is not required. Methods From January 2014 to August 2014 we used the technique in 30 patients with skin defects requiring split-thickness or full-thickness grafts. Patient demographics, clinicopathological details and graft outcome were collected prospectively. Results The majority of cases were carried out for split-thickness skin grafts (n=19) used on the lower limb (n=20). The results of this novel technique were excellent with complete (100%) graft take in all patients. Conclusions Our results demonstrate the clinical application of a barbed device for securing skin grafts with excellent results. We find the technique quick to perform and the barbed device easy to handle, which can be applied without the need for an assistant.

The Overlapping Running Suture Method Using Single Knotless Barbed Absorbable Suture Material for Abdominal Wall Closure after Single Incision Laparoscopic Appendectomy: Comparison with the Traditional Interrupted Closure Technique

  • Kim, Dong Hyun;Park, Jung Ho;Joo, Jung Il;Jeon, Jang Yong;Lim, Sang Woo
    • Journal of Minimally Invasive Surgery
    • /
    • v.21 no.4
    • /
    • pp.160-167
    • /
    • 2018
  • Purpose: The aim of our study was to present an abdominal wall closure technique using barbed suture $V-Loc^{TM}$ 90 after single incision laparoscopic appendectomy (SILA) and to compare perioperative outcomes with conventional layer by layer abdominal wall closure after SILA. Methods: From March 2014 to July 2016, a retrospective case-control study was conducted for a total of 269 consecutive patients who underwent SILA. According to abdominal wall closure methods, 129 patients were classified into the V-Loc closure group and 140 patients were assigned into the conventional layer by layer closure group. In the V-Loc group, abdominal wall closure was performed from the fascia to the skin with a single thread of unidirectional absorbable barbed suture $V-Loc^{TM}$ 90 2-0 using continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time ($40.0{\pm}15.4min$ vs. $44.9{\pm}16.3min$, p=0.013) and abdominal wall cusing continuous running suture and reverse overlapping reinforced running technique. Subcutaneous closure and subcuticular suture were performed with the remaining portion of V-Loc. Results: The V-Loc closure group showed shorter total operation time losure time ($5.5{\pm}0.9min$ vs. $6.5{\pm}0.8min$, p<0.001). Postoperative incision length was significantly shorter in the V-Loc closure group ($1.1{\pm}0.3cm$ vs. $1.8{\pm}0.4cm$, p<0.001). Postoperative wound pain, time to resume diet, postoperative hospital stay, complications including surgical site infection, or mean patient satisfaction score at one month after hospital discharge was not significantly different between the two groups. Conclusion: In conclusion, unidirectional knotless barbed suture is a safe alternative method for abdominal wall closure after SILA. It can save time while providing comparable cosmesis.

Laparoscopic Reinforcement Suture (LARS) on Staple Line of Duodenal Stump Using Barbed Suture in Laparoscopic Gastrectomy for Gastric Cancer: a Prospective Single Arm Phase II Study

  • Kim, Min Chan;Kim, Sang Yun;Kim, Kwan Woo
    • Journal of Gastric Cancer
    • /
    • v.17 no.4
    • /
    • pp.354-362
    • /
    • 2017
  • Purpose: Laparoscopic gastrectomy is accepted as a standard treatment for patients with early gastric cancer in Korea, Japan, and China. However, duodenal stump leakage remains a fatal complication after gastrectomy. We conducted a prospective phase II study to evaluate the safety of the new technique of laparoscopic reinforcement suture (LARS) on the duodenal stump. Materials and Methods: The estimated number of patients required for this study was 100 for a period of 18 months. Inclusion criteria were histologically proven gastric adenocarcinoma treated with laparoscopic distal or total gastrectomy and Billroth II or Roux-en-Y reconstruction. The primary endpoint was the incidence of duodenal stump leakage within the first 30 postoperative days. The secondary endpoints were early postoperative outcomes until discharge. Results: One hundred patients were enrolled between February 2016 and March 2017. The study groups consisted of 65 male and 35 female patients with a mean age (years) of 62.3. Of these, 63 (63%) patients had comorbidities. The mean number of retrieved lymph nodes was 38. The mean operation time was 145 minutes including 7.8 minutes of mean LARS time. There was no occurrence of duodenal stump leakage. Thirteen complications occurred, with one case of reoperation for splenic artery rupture and one case of mortality. Conclusions: Based on the results of this prospective phase II study, LARS can be safely performed in a short operation period without development of duodenal stump leakage. A future randomized prospective controlled trial is required to confirm the surgical benefit of LARS compared to non-LARS.