• 제목/요약/키워드: Bar-Specimen

검색결과 285건 처리시간 0.025초

고속충격하의 노치형상에 따른 동적거동연구 (A study of dynamic behavior with effect of notch shape on high impact)

  • 장영환;박성도;윤희석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.795-798
    • /
    • 1997
  • This study is about the dynamic behavior of steel(SM45C). Dynamic tests were performed using SHPB(Split Hopkinson Pressure Bar) which is designed and modified to be used in both tensile and compressive modes. Quasi-static compression tests were also carried out for the comparison to the dynamic results. Not only the dynamic mechanical properties but also the effect of the notch of the specimen on stress-strain curve were investigated. The dynamic test results reveal that strain and stress are sensitively affected by the notch. The depth and the number of notch increase the stress and decrease the strain.

  • PDF

차체용 부재의 동적 인장 특성 및 충돌 특성 평가를 위한 시험장비 개발 (Testing Equipments for the Evaluation of Dynamic Tensile characteristics and the Crashworthiness of Auto-body Members)

  • 허훈;김석봉
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 추계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2007
  • This paper deals with introduction of testing equipments for the evaluation of dynamic tensile characteristics of auto-body steel sheets and the crashworthiness of auto-body members. The servo-hydraulic high speed material testing machine was developed for tensile tests at the intermediate strain rate to obtain the tensile material properties at the strain rate under 500/sec. The split Hopkinson bar apparatus using the elastic wave was developed for dynamic material characteristics at the high strain rate ranged from 1,000 to 10,000/sec. The servo-hydraulic high speed crash testing machine is the equipment for the evaluation of the collapse load and crashworthiness of auto-body members. High speed carrying truck crashes to specimen with the maximum velocity of 17 m/sec.

  • PDF

Tensile strength of unidirectional CFRP laminate under high strain rate

  • Taniguchi, Norihiko;Nishiwaki, Tsuyoshi;Kawada, Hiroyuki
    • Advanced Composite Materials
    • /
    • 제16권2호
    • /
    • pp.167-180
    • /
    • 2007
  • The tensile strength of unidirectional carbon fiber reinforced plastics under a high strain rate was experimentally investigated. A high-strain-rate test was performed using the tension-type split Hopkinson bar technique. In order to obtain the tensile stress-strain relations, a special fixture was used for the impact tensile specimen. The experimental results demonstrated that the tensile modulus and strength in the longitudinal direction are independent of the strain rate. In contrast, the tensile properties in the transverse direction and the shear properties increase with the strain rate. Moreover, it was observed that the strain-rate dependence of the shear strength is much stronger than that of the transverse strength. The tensile strength of off-axis specimens was measured using an oblique tab, and the experimental results were compared with the tensile strength predicted based on the Tsai-Hill failure criterion. It was concluded that the tensile strength can be characterized quite well using the above failure criterion under dynamic loading conditions.

FRP Box와 판으로 보강된 교량 바닥판 콘크리트의 휨거동 (Flexural Behavior of Bridge Deck Concrete Reinforced with FRP Box and Plate)

  • 남정훈;정상균;윤순종;김병석;조근희
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2004년도 춘계학술발표대회 논문집
    • /
    • pp.13-17
    • /
    • 2004
  • In recent years, the deterioration of reinforced concrete structures has become a serious problem in civil engineering fields. This situation is mainly due to corrosion of steel reinforcing bars embedded in concrete. Recently, there has been a greatly increased demand for the use of FRP (fiber reinforced plastic) in civil engineering field due to their superior mechanical and physical properties. This paper presents an experimental study on the behavior of concrete bridge deck reinforced with FRP Box, FRP Plate, and FRP Re-bar. In tlIe study, mechanical properties of FRP Box, FRP Plate, GFRP Re-bar, and CFRP Grid have been investigated. Full scale one-way deck slab was tested under four point lateral load (equivalent to actual wheel load of DB-24 including impact). Load-deflection and load-strain data were collected through LVDT's and strain gages attached to the specimen.

  • PDF

Improvement of MFL sensing-based damage detection and quantification for steel bar NDE

  • Kim, Ju-Won;Park, Minsu;Kim, Junkyeong;Park, Seunghee
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.239-247
    • /
    • 2018
  • A magnetic flux leakage (MFL) method was applied to detect and quantify defects in a steel bar. A multi-channel MFL sensor head was fabricated using Hall sensors and magnetization yokes with permanent magnets. The MFL sensor head scanned a damaged specimen with five levels of defects to measure the magnetic flux density. A series of signal processing procedures, including an enveloping process based on the Hilbert transform, was performed to clarify the flux leakage signal. The objective damage detection of the enveloped signals was then analyzed by comparing them to a threshold value. To quantitatively analyze the MFL signal according to the damage level, five kinds of damage indices based on the relationship between the enveloped MFL signal and the threshold value were applied. Using the proposed damage indices and the general damage index for the MFL method, the detected MFL signals were quantified and analyzed relative to the magnitude of the damage increase.

강 용접 열영향부 놋치 선단 의 소성 스트레인 평가에 관한 연구 (A Study on Evaluation of Plastic Strain at Notch Tip of Weld HAZ in Steel)

  • 김태영;임재규;정세희
    • Journal of Welding and Joining
    • /
    • 제2권1호
    • /
    • pp.41-48
    • /
    • 1984
  • Recrystallization technique was applied to analyze plastic strain at the notch tip of coarse grain HAZ in mild steel (SB 41) and high strength steel (SA 588). The notch tip of specimen was deformed by three point bending. Accumulated displacement (Crack Opening Displacement ${delta}t$) by the monotonic and cyclic loading under room temperature and hot strain embrittlement temperature ($250^{\circ}C$) was 0~1.0mm. Recrystallization heat treatment conditions were $650^{circ}C{ imes}3hr$ for SB 41 and $700^{circ}C{ imes}3hr$ for SA 588. The experimental results obtained were as follows ; 1) Distribution of the effective plastic strain at plastic zone was appeared by the function of crack opening displacement, and plastic zone or the effective plastic strain increased with crack opening displacement. 2) Plastic strain at notch tip of HAZ due to accumulated hot strain calculated as follows. .epsilon. over bar $_{p}$ = .epsilon. over bar $_{cr}$ (x/ $R_{x}$ ) $^{m}$ (m=0.25) 3) Work hardending ratio of notch tip for hot strain was linearly increased with .epsilon. over bar $_{max}$ and dependent upon the material types.s.

  • PDF

Pulse Shaper를 이용한 SHPB 실험 응력파 제어 효과의 해석 및 실험적 검증 (Numerical and Experimental Verification of Stress Wave Control Effect in SHPB Experiment using Pulse Shaper)

  • 김용희;우민아;강범수;김정
    • 소성∙가공
    • /
    • 제26권5호
    • /
    • pp.314-322
    • /
    • 2017
  • In the high-speed forming analysis, dynamic material properties considering a high strain rate are required. The split Hopkinson pressure bar (SHPB) experiment was performed for measuring dynamic material properties under high strain rate. The pulse shaping method was used to improve the accuracy of the SHPB experiment. A pulse shaper attached to the front of the incident bar was used for specimen dynamic stress equilibrium through stress wave control. Numerical analysis and SHPB test were performed to verify whether the pulse shaper affects the dynamic stress equilibrium in copper and Al6061 specimens. The results of SHPB test and numerical analysis show that the pulse shaper contributes to the dynamic stress equilibrium. Based on the improved stress equilibrium using a pulse shaper, the flow stress curves for copper and Al6061 materials were obtained at strain rates of 1344.4/sec and 1291.6/sec, respectively.

외피형태에 따른 GFRP 보강근의 겹침 이음길이 (Lap Splice Length of Glass Fiber Reinforced Polymer (GFRP) Reinforcing Bars with Different Surface Design)

  • 최동욱;이창호;하상수;박영환;유영찬
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.449-452
    • /
    • 2004
  • The lap splice lengths of deformed steel reinforcing bars and GFRP bars with two different to surface type were experimentally compared using beam specimens. The purpose was to evaluate the length required of the GFRP bar to develop strength equivalent to the conventional steel reinforcing bar. The main test variable was the lap splice length. Two different GFRP bar surfaces were tested: (1) spiral-type GFRP bars and (2) sand coated GFRP bars. For the conventional steel bars (SD400 grade), strength over 400 MPa in tension was reached using the lap splice length of $30d_b$. Splice failure was observed in the specimen with the lap splice length of $20d_b$. For the spiral-type and sand coated GFRP bars, the tensile strength developed in the GFRP bars decreased with decreasing splice lengths. Development of the cracks on beam surfaces was clearly visible for the beams reinforced with the GFRP bars. Mid-span deflections, however, were significantly smaller than the comparable beams with conventional steel bars indicating potential ductility problem.

  • PDF

Bond behavior investigation of ordinary concrete-rebar with hinged beam test and eccentric pull-out test

  • Arslan, Mehmet E.;Pul, Selim
    • Computers and Concrete
    • /
    • 제26권6호
    • /
    • pp.587-593
    • /
    • 2020
  • In this study, bond behavior of ordinary concrete and rebars with different diameters and development length was investigated by using Hinged Beam Test (HBT) and Eccentric Pull-Out Test (EPT) comparatively. For this purpose, three different rebar size and development length depending on rebar diameter were chosen as variables. Three specimens were produced for each series of specimens and totally 54 specimens were tested. At the end of the tests it was observed that obtained results for both tests were quite similar. On the other hand, increased bar size, especially for the specimen with 14 mm bar size and 14 development length (lb), caused shear failure of test specimens. This situation infers that when bigger bar size and lb are used in such test, dimensions of test specimens should be chosen bigger and stirrups should be used for producing of test specimens to obtain more adequate result by preventing shear failure. Also, a nonlinear regression analysis was employed between HBT and EPT results. There was a high correlation between the EPT values, lb, rebar diameters and estimated theoretical HBT. In addition, at the end of the study an equation was suggested to estimate bond strength for HBT by using EPT results.

순환골재 콘크리트와 이형철근의 부착 특성 (The Bond Characteristics of Deformed Bars in Recycled Coarse Aggregates Concrete (RCAC))

  • 전수만;윤현도;최기선;유영찬;김긍환
    • 콘크리트학회논문집
    • /
    • 제20권2호
    • /
    • pp.165-173
    • /
    • 2008
  • 철근콘크리트구조물의 거동에서 가장 중요한 요구사항 중의 하나는 철근과 콘크리트 상호간의 합성 거동을 위한 부착 성능의 확보이며, 순환골재 콘크리트를 구조체로 적용하기 위해서는 순환골재와 철근의 부착 거동을 구명하는 것이 매우 중요한 요소로 등장하게 된다. 이러한 분석에 따라 본 연구에서는 순환굵은골재를 사용한 콘크리트와 철근 상호간의 부착거동을 평가하기 위하여 총 36개의 시험체를 제작하여 압축인발 실험을 수행하였다. 연구를 수행함에 있어 실험에 사용된 변수는 0, 30, 60, 100%의 4가지의 순환굵은골재 치환율 및 철근의 배근 방향 및 위치 (상단근, 하단근)로 하였다. 본 연구를 통하여 얻어진 실험 결과를 종합해 보면, 순환굵은골재를 사용한 콘크리트와 철근간의 부착강도는 실험에 사용된 변수인 철근의 배근방향/위치 및 순환굵은골재 치환율에 따라서 그 영향이 상호 다르게 나타나는 것으로 파악되었다. 즉, 수직배근된 철근의 경우는 순환골재의 치환율에 관계없이 상호 유사한 값을 나타내고 있는 반면, 수평 배근된 시험체의 경우는 순환굵은골재 치환율 및 철근의 배근 위치에 영향을 받는 것으로 나타났다. 이는 순환골재의 치환율 변화에 따라 콘크리트 침하량의 차이가 발생되며 추가적으로 상부철근을 통과하지 못한 기포의 영향으로 인해 부착면적이 감소되었기 때문인 것으로 판단되며, 이로 인하여 HU type 시험체의 최대부착응력이 다른 시험체에 비하여 현저히 작은 것으로 나타났다. 따라서 순환골재 콘크리트를 포함하여 철근과 콘크리트의 부착강도 평가를 위한 기존의 규준식에서 철근의 위치에 따른 기여도를 재검토할 필요성이 있을 것으로 사료된다.