• 제목/요약/키워드: Bank strength

검색결과 55건 처리시간 0.024초

The effects of dentin bonding agent formulas on their polymerization quality, and together with tooth tissues on their microleakage and shear bond strength: an explorative 3-step experiment

  • Erfan, Mohmmad;Jafarzadeh-Kashi, Tahereh Sadat;Ghadiri, Malihe;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.333-345
    • /
    • 2014
  • PURPOSE. Bonding agents (BA) are the crucial weak link of composite restorations. Since the commercial materials' compositions are not disclosed, studies to formulize the optimum ratios of different components are of value. The aim of this study was to find a proper formula of BAs. MATERIALS AND METHODS. This explorative experimental in vitro study was composed of 4 different sets of extensive experiments. A commercial BA and 7 experimental formulas were compared in terms of degree of conversion (5 experimental formulas), shear bond strength, mode of failure, and microleakage (3 experimental formulas). Statistical analyses were performed (${\alpha}$=.05). The DC of selected formula was tested one year later. RESULTS. The two-way ANOVA indicated a significant difference between the shear bond strength (SBS) of two tissues (dentin vs. enamel, P=.0001) in a way that dentinal bonds were weaker. However, there was no difference between the four materials (P=.283). The adhesive mode of failure was predominant in all groups. No differences between the microleakage of the four materials at occlusal (P=.788) or gingival (P=.508) sites were detected (Kruskal-Wallis). The Mann-Whitney U test showed a significant difference between the microleakage of all materials (3 experimental formulas and a commercial material) together at the occlusal site versus the gingival site (P=.041). CONCLUSION. A formula with 62% bisphenol A-glycidyl methacrylate (Bis-GMA), 37% hydroxy ethyl methacrylate (HEMA), 0.3% camphorquinone (CQ), and 0.7% dimethyl-para-toluidine (DMPT) seems a proper formula for mass production. The microleakage and SBS might be respectively higher and lower on dentin compared to enamel.

필터뱅크를 이용한 한국어 숫자음 인식에 관한 연구 (A Study on the Recognition of Korean Digits using Filter-Bank)

  • 김홍식;한득영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.481-483
    • /
    • 1989
  • This paper is concentrated on the recognition of Korean Digits. The speech signals of each of digits are fed into computer through the 18 bandpass filters, AD converter. Spectrum input data are analyzed and used. BASIC program language is used for recognition performance and the result of recognition is outputed to computer screen and printer. In this paper, the strength and weakness of filter-bank analysis method is described and the technique of real-time recognition is argued. In this experiment, Ratio of recognition for speaker dependent recognition was about 97% and recognition time was also satisfied. Therefore, A way of speaker independent recognition will be presented and using for special communication in the future.

  • PDF

저수위 변동에 영향을 받는 강기슭의 산사태 해석 II (Landslide Analysis of River Bank Affected by Water Level Fluctuation II)

  • 김유성;왕 유메이;최재선
    • 한국지반신소재학회논문집
    • /
    • 제9권3호
    • /
    • pp.87-93
    • /
    • 2010
  • 저수지의 수위변화는 저수지 주변 강기슭 사면파괴의 주요 요인이다. 중국의 삼협댐 저수위는 홍수량 조절을 위해 145m와 175m사이에서 변화한다. 삼협댐 저수위의 정상적 운영상태에서 저수위 변동속도는 0.67m~3.0m의 범위에 있다. 마지아고 사면은 자시강의 2.1km 상류 좌측기슭에 위치한다. 자시강은 삼협지역내에 있는 양츠강의 지류이다. 2003년 저수위가 95m에서 135m로 상승한 직후, 마지아고 사면의 후면부에서 길이 20m, 폭 3~10의 균열이 발생하였다. 지금은 균열 보수 후 특별한 징후는 보이지 않고는 있으나, 이 큰 균열은 마지아고 사면의 산사태 가능성을 암시하고 있었다. 이 연구에서는 침투해석에서 얻어진 간극수압을 저수위 변동에 따른 안전율 변화를 평가하기 위해 사용되었다. 안전율 평가는 한계평형해석에 의한 사면안정해석에 의해 수행되었다. 한계평형해석에서 전단강도에 미치는 부의 간극수압 효과는 불포화 흙에 대한 프레드런드의 전단강도식을 사용하여 고려하였다. 연구결과 강기슭사면의 안전율은 저수위의 상승, 하강에 따라 감소와 증가의 경향을 보이나, 가장 위험한 상태는 저수위가 최대높이를 장기간 유지할 때인 것으로 나타났다.

  • PDF

계안 복원을 위한 식생기반재 돌망태 옹벽의 계안 안정효과 분석 (Slope Stability Analysis of New Gabion Wall System with Vegetation Base Materials for Stream Bank Stability and Rehabilitation)

  • 최형태;정용호;박재현
    • 한국산림과학회지
    • /
    • 제101권1호
    • /
    • pp.130-137
    • /
    • 2012
  • 본 연구는 산지계류의 자연친화적 복원을 위해 산지 계류 특성에 적합한 안정성과 구조를 가지면서 계안 보호 및 복원이 가능하도록 식생기반재 돌망태 공법을 개발하고, 개발 공법의 치수안정성, 생태계 구조 및 기능, 경관에 대한 모니터링을 통해 공법의 효능을 평가하는데 그 목적이 있다. 본 보에서는 개발된 계류복원을 위한 식생기 반재 돌망태 공법 중 식생기반재 돌망태 옹벽 공법의 사면안정효과를 중심으로 개발 공법의 효능을 정리, 보고하였다. 개발된 식생기반재 돌망태 옹벽의 표준형태는 배면이 수직인 사다리꼴 상자이며, 전면에 경사각 $60^{\circ}{\sim}65^{\circ}$의 비탈면을 조성하여 식생의 상향 생육이 가능하도록 조치하였다. 식생기반재 돌망태 옹벽의 수리학적 안정성 분석 결과 식생으로 피복되었을 때 가장 높은 한계전단응력을 가지는 것으로 나타났으며, 많은 유량에서도 안정된 계안보호효과를 발휘하는 것으로 분석되었다. 또한, 식생기반재 돌망태 옹벽의 활동 및 전도에 대한 안정 해석 결과 적정 안전계수 1.5를 훨씬 상회하는 것으로 나타나 본 연구에서 시공한 식생기반재 돌망태 옹벽은 활동 및 전도에 대한 안정성을 가지는 것으로 분석되었다.

Performance of partial strength connection connected by thick plate between column flanges

  • Tahir, Mahmood M.;Juki, Irwan;Ishak, Mohd Y.;Mohammad, Shahrin;Awang, Abdullah Z.;Plank, Roger
    • Structural Engineering and Mechanics
    • /
    • 제51권2호
    • /
    • pp.215-228
    • /
    • 2014
  • Traditional beam connections to the minor axis of a column have relatively low strength and stiffness. A modified detail, using a plate welded between the toes of the column flange - referred to as a toe plate connection - is examined in this paper. The results of an experimental investigation for both flush and extended end-plate connections connected to a 25 mm thick end-plate are presented. The tests are complemented by finite element modelling which compares very well with the test observations. The results show a significant increase in both moment resistance and initial stiffness for this connection detail compared with connections made directly to the column web. This offers the prospect of more optimal solutions taking advantage of partial strength frame design for the minor axis as well as major axis.

하천제방 양질사토에 대한 수크령과 억새 뿌리의 토양전단강도 보강효과 (Effect of Soil Reinforcement on Shear Strength by Pennisetum alopecuroides and Miscanthus sinensis Roots on Loamy Sand at River Banks)

  • 당지희;조용현;이춘석
    • 한국환경복원기술학회지
    • /
    • 제20권2호
    • /
    • pp.79-91
    • /
    • 2017
  • This study was conducted to find out the physical properties and soil shearing strength reinforcement effect of herbaceous plants for the slope revegetation works. Two native plants(Pennisetum alopecuroides and Miscanthus sinensis) were used for this experiment, because they have excellent seed germination rates without preconditioning, and grow naturally around rivers. To identify the physical properties, the partial dry weight of plants were investigated. To identify the soil shearing strength reinforcement effect, the respective soil shearing strengths of the control soils, Pennisetum alopecuroides, Miscanthus sinensis samples were measured. Also, we did a correlation analysis to examine the relation of shearing strength to plant features. The results are summarized as follows: 1. The average dry weight of Pennisetum alopecuroides samples consists of 52.36% above ground and 47.64% at root. And in dry weight, 78.24% of it's root distributes within 10 cm in soil depth. Meanwhile the average dry weight of Miscanthus sinensis samples consists of 52.91% above ground and 47.09% at root. And in dry weight, 82.95% of it's root distributes within 10 cm in soil depth. 2. The results of correlation analysis showed that for both Pennisetum alopecuroides and Miscanthus sinensis, it could not be said that there was any correlation between shearing strength and plant characteristics, and statistically they were not meaningful. 3. In the shearing strength test with control soils, Pennisetum alopecuroides, Miscanthus sinensis as subjects, the differences in shearing strength measurement results were modest, and the order was shown as control soils < Pennisetum alopecuroides < Miscanthus sinensis, so the soil shearing strength reinforcement effect by the Pennisetum alopecuroides and the Miscanthus sinensis on loamy sand at river banks surface was confirmed.

비접지 분로 콘덴서 뱅크의 투입제어방식에 대한 시뮬레이션 검증 (Verification of Controlled Closing Method for Unearthed Shunt Capacitor Banks by Simulation)

  • 이우영;박경엽;정진교;김희진
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권9호
    • /
    • pp.448-453
    • /
    • 2003
  • In this paper the controlled closing algorithm of the circuit breaker for isolated capacitor banks is proposed. The characteristics of circuit breakers such as RDDS(rate of decrease of dielectric strength) and a mechanical operating tolerance should be also taken into account to locate contact touch instants around voltage zero. The analysis results on the voltages across circuit breaker terminals upon closing operation play an important roles to describe the suggested method. The simulations carried out in order to verify the performance of this method show that the closing instants obtained from the proposed method provide a good suppression effect on the closing transients for both single and back-to-back capacitor banks.

The Frequency and Length Dependence of the Target Strength of the Largehead Hairtail (Trichiurus lepturus) in Korean Waters

  • HwangBo, Young;Lee, Dae-Jae;Lee, Yoo-Won;Lee, Kyoung-Hoon
    • Fisheries and Aquatic Sciences
    • /
    • 제12권2호
    • /
    • pp.152-161
    • /
    • 2009
  • The largehead hairtail (Trichiurus lepturus) is one of the most common fisheries stocks in the East China Sea and the Yellow Sea. The species is caught using a variety of fishing tools, such as a stow net or a long line, as well as jigging and trawling. Scientific investigations have been conducted throughout the world to enable evidence-based estimations for the management and protection of the main fisheries biomass. For example, inshore and offshore hydro acoustic surveys are performed annually using bottom- and mid-water trawls around the Korean Peninsula. However, to date, no acoustic survey has been conducted to estimate fish size distribution, which is necessary to construct a data bank of target strength (TS) relative to fish species, length (L), and frequency. This study describes the frequency and length dependence of TS among fishes in Korean waters for the purpose of constructing such a TS data bank. TS measurements of the largehead hairtail were carried out in a water tank (L 5 m$\times$width 6 m$\times$ height 5 m) at frequencies of 50, 75, 120, and 200 kHz, using a tethering method. The average TS patterns were measured as a function of tilt angle, ranging from $-45^{\circ}$ (head down) to $+45^{\circ}$ (head up) every $0.2^{\circ}$. The length conversion constant ($b_{20}$) was estimated under the assumption that TS is proportional to the square of the length. In addition, in situ TS measurements on live largehead hairtails were performed using a split beam echo sounder.

호기성 그래뉼 슬러지를 이용한 칼슘이온의 생물흡착에 관한 연구 (A Study on Biosorption of Calcium Ion Using Aerobic Granular Sludge)

  • 김현구;안대희
    • 한국환경과학회지
    • /
    • 제28권8호
    • /
    • pp.677-687
    • /
    • 2019
  • This study evaluated the biosorption properties of calcium ion using Aerobic Granular Sludge (AGS). A sequencing batch reactor was used to induce the production of Extracellular Polymeric Substances (EPS) through salinity injection, and the calcium ion adsorption efficiency was analyzed by a batch test. The EPS contents showed significant changes (104-136 mg/g MLVSS) at different salinity concentrations. The calcium ion adsorption efficiency was highest for AGS collected at 5.0% salinity, and it was confirmed that the biosorption efficiency of AGS was increased owing to the increase in EPS content. The results of the Freundlich isotherms showed that the ion binding strength (1/n) was 0.3941-0.7242 and the adsorption capacity ($K_f$) was 2.4082-3.3312. The specific surface area and the pore size of the AGS were $586.1m^2/g$ and 0.7547 nm, respectively, which were not significantly different from each other. It was confirmed that the influence of biological properties, such as EPS content, was relatively large among the factors affecting calcium ion adsorption.

Influence of pinching effect of exterior joints on the seismic behavior of RC frames

  • Favvata, Maria J.;Karayannis, Chris G.
    • Earthquakes and Structures
    • /
    • 제6권1호
    • /
    • pp.89-110
    • /
    • 2014
  • Nonlinear dynamic analyses are carried out to investigate the influence of the pinching hysteretic response of the exterior RC beam-column joints on the seismic behavior of multistory RC frame structures. The effect of the pinching on the local and global mechanisms of an 8-storey bare frame and an 8-storey pilotis type frame structure is evaluated. Further, an experimental data bank extracted from literature is used to acquire experimental experience of the range of the real levels that have to be considered for the pinching effect on the hysteretic response of the joints. Thus, three different cases for the hysteretic response of the joints are considered: (a) joints with strength and stiffness degradation characteristics but without pinching effect, (b) joints with strength degradation, stiffness degradation and low pinching effect and (c) joints with strength degradation, stiffness degradation and high pinching effect. For the simulation of the beam-column joints a special-purpose rotational spring element that incorporates the examined hysteretic options developed by the authors and implemented in a well-known nonlinear dynamic analysis program is employed for the analysis of the structural systems. The results of this study indicate that the effect of pinching on the local and global responses of the examined cases is not really significant at early stages of the seismic loading and especially in the cases when strength degradation in the core of exterior joint has occurred. Nevertheless in the cases when strength degradation does not occur in the joints the pinching may increase the demands for ductility and become critical for the columns at the base floor of the frame structures. Finally, as it was expected the ability for energy absorption was reduced due to pinching effect.