• 제목/요약/키워드: Balloon technique

검색결과 72건 처리시간 0.025초

Endovascular Treatment of Wide-Necked Intracranial Aneurysms Using Balloon-Assisted Technique with HyperForm Balloon

  • Youn, Sang-O;Lee, Jae-Il;Ko, Jun-Kyung;Lee, Tae-Hong;Choi, Chang-Hwa
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권3호
    • /
    • pp.207-212
    • /
    • 2010
  • Objective : To assess the feasibility, safety, and effectiveness of the balloon-assisted technique with HyperForm balloon in the endovascular treatment of wide-necked intracranial aneurysms. Methods : A total of 34 patients with 34 wide-necked intracranial aneurysms were treated with endovascular coil embolization using balloon-assisted technique with Hyperform balloon. Twenty-nine aneurysms (85.3%) were located in the anterior circulation. The group of patients was comprised of 16 men and 18 women, aged 33 to 72 years (mean : 60.6 years). The size of aneurysms was in the range of 2.0 to 22.0 mm (mean 5.5 mm) and one of neck was 2.0 to 11.9 mm (mean 3.8 mm). The dome to neck ratio was ranged from 0.83 to 1.43 (1.15). Sixteen patients were treated for unruptured aneurysms and the remaining 18 presented with a subarachnoid hemorrhage. Results : In the 34 aneurysms treated by the remodeling technique with HyperForm balloon, immediate angiographic results consisted of total occlusion in 31 cases (91.2%) and partial occlusion in three cases (8.8%). There were five procedure-related complications (14.7%), including two coil protrusions and three thromboembolisms; Except one patient, all were successfully resolved without permanent neurologic deficit. No new bleeding occurred during the follow-up. Twenty patients (59%) underwent angiographic follow-up from 2 to 33 months (mean 9.2 months) after treatment. Focal recanalization with coil compaction of the neck portion was observed in 5 cases (25%). Only one case showed major recanalization and underwent stent-assisted coil embolization. Conclusion : The balloon-assisted technique with Hyperform balloon is a feasible, safe, and effective endovascular treatment of wide-necked cerebral aneurysms.

Orbital wall restoration with primary bone fragments in complex orbital fractures

  • Jong Hyun Park;Dong Hee Kang;Hong Bae Jeon;Hyonsurk Kim
    • 대한두개안면성형외과학회지
    • /
    • 제24권2호
    • /
    • pp.52-58
    • /
    • 2023
  • Background: Complex orbital fractures are impure orbital fractures because they involve the orbital walls and mid-facial bones. The author reported an orbital wall restoration technique in which the primary orbital wall fragments were restored to their prior position in complex orbital fractures in 2020. As a follow-up to a previous preliminary study, this study retrospectively reviewed the surgical results of complex orbital wall fractures over a 4-year period and compared the surgical outcomes by dividing them into groups with and without balloon restoration. Methods: Data of 939 patients with facial bone fractures between August 2018 and August 2022 were reviewed. Of these, 154 had complex orbital fractures. Among them, 44 and 110 underwent reduction with and without the balloon technique respectively. Pre- and postoperative Naugle exophthalmometer (Good-Lite Co.) scales were evaluated. The orbital volume and orbital volume ratio were calculated from preoperative and 6 months postoperative computed tomography images. Results: Among 154 patients with complex orbital fractures, 44 patients underwent restoration with the balloon technique, and 110 patients underwent restoration without it. The Naugle scale did not differ significantly between the two groups, but the orbital volume ratio significantly decreased by 3.32% and 2.39% in groups with and without the balloon technique and the difference in OVR was significantly greater in patients in the balloon restoration group compared with the control group. Postoperative balloon rupture occurred in six out of 44 cases (13.64%). None of the six patients with balloon rupture showed significant enophthalmos at 6 months of follow-up. Conclusion: The balloon rupture rate was 13.64% (6/44 cases) with marginal screw fixation, blunt screws, and extra protection with a resorbable foam dressing. Furthermore, we restored the orbital wall with primary orbital fragments using balloon support in complex orbital wall fractures.

풍선도관을 이용한 새로운 갑상성형술의 제안 (New Thyroplasty Technique Using Balloon Catheter)

  • 유영삼;최찬;김희주
    • 대한후두음성언어의학회지
    • /
    • 제18권2호
    • /
    • pp.118-121
    • /
    • 2007
  • Background and Objectives: Silicone, Gore- Tex, Gelfoam, Collagen and autologous fat are used for thyroplasty in case of vocal fold paralysis or paresis. These implants have many advantages, such as biocompatibility, low price and easy handling and accessibility. But additional voice modification is impossible using these materials. So, we design new thyroplasty technique, called balloon thyroplasty using Foley catheter. Materal and Methods: The fresh human larynx was dissected in midline posteriorly. Minithyrotomy hole was created using 5mm cutting burr in the midline of thyroid cartilage. Subperichondrial dissection was done using Duckbill elevator up to vocal process. Balloon catheter(1.5cm balloon size) was inserted through the subperichondrial tunnel. The balloon was inflated to medialize the vocal cord. Results: After ballooning, the true vocal cord medialized mimicking thyroplasty. Conclusion: The authors found that Balloon thyroplasty could be a good candidate for vocal fold medialization technique. The technical refinement and in vivo safety are reserved for the ongoing study.

  • PDF

Single-Balloon Kyphoplasty in Osteoporotic Vertebral Compression Fractures : Far-Lateral Extrapedicular Approach

  • Ryu, Kyeong-Sik;Huh, Han-Yong;Jun, Sung-Chul;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권2호
    • /
    • pp.122-126
    • /
    • 2009
  • Single-balloon kyphoplasty via an extrapedicular approach has been reported to be effective because it requires less time than conventional two-balloon kyphoplasty and has comparable therapeutic efficacy. However, single-balloon kyphoplasty is not popular because the extrapedicular approach is believed to be complicated and unsuitable for the thoracolumbar and lumbar spine. The authors describe a standardized surgical technique that utilizes a far-lateral extrapedicular approach for single-balloon kyphoplasty, which can be performed in any part of the spine by physicians without substantial difficulty.

내시경과 선택적 도뇨관 풍선을 이용한 안와하벽복원술 (Orbital Floor Reconstruction Using Endoscope and Selected Urethral Balloon Catheter)

  • 최환준;이주철;이형교;김준혁
    • Archives of Plastic Surgery
    • /
    • 제38권1호
    • /
    • pp.35-42
    • /
    • 2011
  • Purpose: Blow-out fractures can be reduced using various methods. The orbital reconstruction technique using a balloon under endoscopic control has advantages over other methods. However, this method has some problems too, such as postoperative follow-up, management of the balloon catheter, and reduction of the posterior orbital floor. Thus, we developed a simple, effective method for orbital floor reduction that involves molding and shaping the antral balloon catheter. Methods: A 0, 30, or $70^{\circ}$, 4-mm endoscope was placed though a two-point, 5-mm maxillary antrostomy. The balloon catheter is placed directly at the orbital apex to reconstruct the anterior shelf (spherical shape), while it is turned in a U-shape towards the anterior maxilla for the posterior shelf (elliptical shape). Orbital floor defects, compound or comminuted fractures are reconstructed with alloplastic materials through an open lid incision under the endoscopic control. Results: This technique was applied to ten patients with orbital floor fractures: five anterior shelf and five posterior shelf fracture, respectively. Four of the patients had zygomatico-orbital fractures, while the rest had isolated orbital floor fractures. Two patients were given porous polyethylene implants Synpor$^{(R)}$) and three underwent reconstruction with a resorbable mesh plate. No complication associated with this technique was identified. Conclusion: The freestyle placement and selection of a urinary balloon catheter under endoscopic control and the preoperative estimation of the volume enhanced the stabilization of the orbital contour. This method improves the adaptation of the orbital floor without the risk of injuring the surrounding orbital contents, dissecting blindly, or using sharp traction. One drawback of this method is the patient's discomfort from the catheter during treatment.

Fogarty balloon catheter를 이용한 영유아 기관지 식물성 이물 제거술의 의의 (Evaluation of the safety and efficacy for the technique of removing VFB from the bronchial tree in infants and early childhood using Fogarty balloon catheter.)

  • 오천환;김장욱
    • 대한기관식도과학회지
    • /
    • 제7권1호
    • /
    • pp.14-18
    • /
    • 2001
  • Background and Objectives: Vegetable Foreign bodies (VFB) in the bronchial tree may be complicated by fragmentation, slippage and impaction during the removal with forceps. This study is to evaluate the safety and efficacy for the technique of removing VFB from the bronchial tree in infants and early childhood using Fogarty balloon catheter. Materials and methods : The subjects consisted of 18 infants and early childhood (7-22 months old) with VFB in the bronchial tree from January 1991 through October 1998. The authors first attempted removal of VFB with forceps and if that failed, removed VFB with Fogarty arterial embolectomy catheter under the ventilating bronchoscopy and general anesthesia. Results: We removed 6 VFB with forceps. could not remove anymore, and so removed 12 VFB with Fogarty catheter. In 8 VFB of less than 24 hours, we could remove 6 VFB with forceps and 2 VFB which could not be removed with forceps were removed with Fogarty catheter. In 10 VFB of more than 24 hours, we could not remove with forceps and removed with Fogarty catheter. Conclusions : VFB in the bronchial tree of infants and early childhood can usually be removed with forceps. But we think that Fogarty balloon catheter technique is a easy, safe method for the removal of bronchial VFB of more than 24 hours, fragmentation, impaction, lower bronchus and too round or slippery to remove with forceps in infants and early childhood.

  • PDF

Orbital wall restoration with primary bone fragments in complex orbital fractures: A preliminary study

  • Jung, Joo Sung;Kang, Dong Hee;Lim, Nam Kyu;Kim, Hyonsurk
    • 대한두개안면성형외과학회지
    • /
    • 제21권3호
    • /
    • pp.156-160
    • /
    • 2020
  • Background: We have reported orbital wall restoration surgery with primary orbital wall fragment in pure blowout fractures using a combination of transorbital and transnasal approach in pure blow out fractures. However, this method was thought to be difficult to use for complex orbital wall fractures, since the sharp screw tip that fixate the maxillary wall increases the risk of balloon ruptures. In this study, we reviewed 23 cases of complex orbital fractures that underwent orbital wall restoration surgery with primary orbital wall fragment and evaluated the result. Methods: A retrospective review was conducted of 23 patients with complex orbital fracture who underwent orbital restoration surgery with primary orbital wall fragments between 2012 and 2019. The patients underwent orbital wall restoration surgery with primary orbital wall fragment with temporary balloon support. The surgical results were evaluated by the Naugle scale and a comparison of preoperative and postoperative orbital volume ratio. Complex fracture type, type of screw used for fixation and complications such as balloon rupture were also investigated. Results: There were 23 patients with complex orbital fracture that used transnasal balloon technique for restoration. 17 cases had a successful outcome with no complications, three patients had postoperative balloon rupture, two patients had soft-tissue infection, and one patient had balloon malposition. Conclusion: The orbital wall restoration technique with temporary balloon support can produce favorable results when done correctly even in complex orbital wall fracture. Seventeen cases had favorable results, six cases had postoperative complications thus additional procedure seems necessary to complement this method.

Reduction of the Isolated Anterior Wall of the Maxillary Sinus Fracture with Double Urinary Balloon Catheters and Fibrin Glue

  • Kim, Jaehee;Yang, Ho Jik;Kim, Jong Hwan;Kim, Su Jin
    • 대한두개안면성형외과학회지
    • /
    • 제18권4호
    • /
    • pp.238-242
    • /
    • 2017
  • Background: Conservative treatment is performed for isolated anterior wall of the maxillary sinus fractures, in many cases when the fracture is clinically not severe and asymptomatic. Despite the absence of symptoms, complications such as sinusitis, rhinitis, and chronic purulent secretion may develop; therefore, successful reduction is required. We attempted to reduce the risk of complications using an alternative technique: reduction of the fracture with two urinary balloon catheters inserted through the maxillary ostium and fixation using fibrin glue, which minimizes the damage to the bony fragments and sinus mucosa. Methods: In this study, 38 patients who were diagnosed with an isolated anterior wall of the maxillary sinus fracture at our hospital between January 2014 and January 2017 were enrolled. The fracture site was exposed via the Caldwell-Luc approach followed by reduction through the insertion of two urinary balloon catheters using a nasal endoscope and fixation with fibrin glue. The sex, cause of fracture, physical examination, and presence of complications were examined and patient's medical records and facial bone computed tomography scans were analyzed. Results: Radiological evaluation showed that there was no evidence of collapsed reduction fragments. Although some patients had remaining symptoms of hypoesthesia (15%; 3 patients), there were no complications such as infection, rhinitis, sinusitis, and chronic purulent secretion at the surgical site. Conclusion: In this study, we present an alternative surgical technique using two urinary balloon catheters and fibrin glue for the successful reconstruction of an isolated anterior wall of the maxillary sinus fracture. This technique enables precise restoration with a reduced risk of complications.

대동맥 내 풍선 차단법을 이용한 여러 가지 심장수술 (Endovascular Aortic Balloon Clamping for Various Heart Disease)

  • 최진호;박표원
    • Journal of Chest Surgery
    • /
    • 제41권1호
    • /
    • pp.61-67
    • /
    • 2008
  • 배경: 여러 가지 원인에 의해서 일반적인 상행대동맥 차단법을 이용한 수술이 제한되는 경우가 있다. 본 연구는 대동맥 내 풍선카테터를 이용하여 대동맥 내 차단법을 이용한 수술의 효용성 및 안전성에 대해 알아보고자 하였다. 대상 및 방법: 2004년 4월부터 2007년 1월까지 총 7명의 환자에서 대동맥내 차단법을 이용한 수술을 시행하였다. 6예에서 RAP catheter를 사용하였고, 2예에서 Pruitt's balloon catheter를 사용하였다. 원인 질환으로는 흉골하 대동맥 근부의 가성대동맥류가 4예, 상행대동맥의 광범위한 석회화를 동반한 대동맥 판막 역류증이 2예, 심방중격결손이 1예이었다. 5예에서 이전에 1회 이상의 심장수술을 받은 과거력이 있었다. 결과: 전 예에서 성공적인 도관의 삽입 및 대동맥 차단이 이루어졌다. 1예에서 RAP catheter의 풍선이 파열되어, 상행대동맥 내 풍선도관을 추가적으로 삽입하여 대동맥 차단을 하였다. 수술사망은 없었으며, 대동맥 박리, 뇌졸중이나 혈관계 합병증은 없었다. 결론: 대동맥 내 풍선을 이용한 대동맥 차단법은 전통적인 수술방법으로 접근하기 어려운 질환에서 유용한 대안으로 이용될 수 있다고 생각된다.

Effectiveness of Anchoring with Balloon Guide Catheter and Stent Retriever in Difficult Mechanical Thrombectomy for Large Vessel Occlusion

  • Yi, Ho Jun;Kim, Bum-Tae;Shin, Dong-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권4호
    • /
    • pp.514-522
    • /
    • 2022
  • Objective : A distal navigation of a large bore aspiration catheter during mechanical thrombectomy (MT) is important. However, delivering a large bore aspiration catheter is difficult to a tortuous or atherosclerotic artery. We report the experience of anchoring with balloon guide catheter (BGC) and stent retriever to facilitate the passage of an aspiration catheter in MT. Methods : When navigating an aspiration catheter failed with a conventional co-axial microcatheter delivery, an anchoring technique was used. Two types of anchoring technique were applied to facilitate distal navigation of a large bore aspiration catheter during MT. First, a passage of aspiration catheter was attempted with a proximal BGC anchoring technique. If this technique also failed, another anchoring technique with distal stent retriever was tried. Consecutive patients who underwent MT with an anchoring technique were identified. Details of procedure, radiologic outcomes, and safety variables were evaluated. Results : A total of 67 patients underwent MT with an anchoring technique. Initial trial of aspiration catheter passage with proximal BGC anchoring technique was successful for 35 patients (52.2%) and the second trial with distal stent retriever anchoring was successful for 32 patients (47.8%). Overall, navigation of a large bore aspiration catheter was successful for all patients (100%) without any procedure related complications. Conclusion : Our study showed the usefulness of anchoring technique with proximal BGC and distal stent retriever during MT, especially in those with an unfavorable anatomical structure. This technique could be an alternative option for delivering an of aspiration catheter to a distal location.