• 제목/요약/키워드: Balloon Catheter

검색결과 105건 처리시간 0.029초

Merit of Zone III Resuscitative Endovascular Occlusion of the Aorta under Real-Time Fluoroscopy in Hybrid ER: A Case of REBOA in Traumatic Cardiac Arrest

  • Lee, Sung Do;Chung, Seungwoo;Ki, Young Jun;Seo, Sang Hyun;Park, Chan Yong
    • Journal of Trauma and Injury
    • /
    • 제33권3호
    • /
    • pp.191-194
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a novel technique to maintain proximal arterial pressure. It is important to locate the balloon catheter correctly in performing REBOA but it is inaccurate to check the catheter position by external measurement. Even if the position of the catheter is initially confirmed by X-ray, it is difficult to determine the location of the catheter that changes according to various situations. We performed REBOA under real-time fluoroscopy and could maintain the catheter in correct position under various situations.

Clinical Application of an Image-Guided Intervention in Three Dogs

  • Choi, Minsik;Kwon, Dohoon;Ahn, Jisoo;Ko, Minjung;Ahn, Jiyoung;Jung, Joohyun;Kim, Hakhyun;Kang, Ji-Houn;Chang, Dongwoo
    • 한국임상수의학회지
    • /
    • 제37권2호
    • /
    • pp.100-105
    • /
    • 2020
  • A 9-month-old, 11.3 kg, intact, male, mixed-breed dog was referred for treatment of cor triatriatum dexter (CTD); a 5-month-old, 1.9 kg, intact, male Maltese for pulmonic stenosis (PS); and a 3-year-old, 6.62 kg, intact, female West Highland white terrier for esophageal stricture with regurgitation. A balloon catheter intervention was performed in the dog with CTD, and subsequent color Doppler ultrasound and abdominal ultrasound showed normal blood flow across the perforated membrane dividing the right atrium and the disappearance of the severe ascites present before treatment. Balloon catheter intervention in the dog with PS reduced the blood flow through the stenosis from 5.82 m/s to 3.97 m/s. In the dog with esophageal stricture, balloon catheter intervention widened the esophagus and no subsequent regurgitation was observed. Balloon catheter intervention is an interventional radiology procedure that represents a definitive treatment option for various stenotic lesions in dogs, including CTD, PS, and esophageal stricture. Although interventional radiology procedures for these diseases have already been reported, details of procedures and successful outcome have not been reported in Korea.

Balloon 확장술에 의한 식도협착증의 치료 (BALLOON DILATATION OF ESOPHAGEAL STRICTURE)

  • 윤성철;나인국;김형종;노영수;임현준;이길우
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1991년도 제25차 학술대회 연제순서 및 초록
    • /
    • pp.33-33
    • /
    • 1991
  • 부식성 식도염에서 속발한 식도협착의 비외과적 치료법으로 사용되었던 종래의 각종 소식자를 이용한 확장술은 그 효과가 일시적이며 소아에서 시행시 많은 문제점이 있다. 근래들어 관상동맥, 요관, 대장 등의 협착에 사용되어온 balloon Catheter를 이용한 식도 확장술은 비교적 안전하고 효과적이어서 소아나 정도가 심한 식도협착의 치료에 큰 도움을 줄 수 있다. 본 교실에서는 최근 2년간 부식성 식도염 후 속발한 식도협착 6 례를 Balloon catheter 확장법으로 치료하여 아래와 같은 결과를 얻었기에 보고하는 바이다. 1) 전체 6명 중 남자가 4명 여자가 2명으로 평균 연령은 45.7세였다. 2) 부식제의 종류는 가성소다가 5명 초산이 1명이였다. 3) 협착부위는 1례가 경부식도이며 5례가 흉부식도였고 이중 1례는 다발성 협착이 였다. 4) 확장 전 식도조영사진 상 협착부위의 평균 내경은 4.3mm였다. 5) 확장술을 시행한 횟수는 2회에서 5회( 평균 3.5회 )로 확장술이 끝난 후의 평균 내경은 13.5mm였다. 5) 확장술시 3례에서 식도파열이 발생하였으나 보존적 치료법으로 치유되었다.

  • PDF

Effectiveness of percutaneous epidural neuroplasty using a balloon catheter in patients with chronic spinal stenosis accompanying mild spondylolisthesis: a longitudinal cohort study

  • Myong-Hwan Karm;Chan-Sik Kim;Doo-Hwan Kim;Dongreul Lee;Youngmu Kim;Jin-Woo Shin;Seong-Soo Choi
    • The Korean Journal of Pain
    • /
    • 제36권2호
    • /
    • pp.184-194
    • /
    • 2023
  • Background: Degenerative lumbar spondylolisthesis (DLS) is frequently associated with lumbar spinal stenosis (LSS) and conservative treatments such as epidural steroid injection do not have long-term benefits in LSS patients with DLS. This study evaluated the effectiveness of percutaneous epidural neuroplasty using a balloon catheter in patients with LSS and DLS. Methods: Patients' sex, age, body mass index, diabetes, hypertension, stenosis grading, pain duration, location, pain intensity, and medications were retrieved from electronic medical records. At 1, 3, and 6 months following the procedure, data on pain severity, medication usage, and physical functional status were analyzed. A generalized estimating equations model was used at the six-month follow-up. Patients were divided into those with DLS (the spondylolisthesis group) and those without DLS (the no spondylolisthesis group) to evaluate whether the effects of percutaneous epidural neuroplasty using a balloon catheter were different. Results: A total of 826 patients were included (spondylolisthesis: 433 patients, 52.4%; no spondylolisthesis: 393 patients, 47.6%). Age, body mass index, hypertension, pain location, and stenosis grading were statistically different between the two groups. The generalized estimating equations analyses with unadjusted and adjusted estimation revealed a significant improvement in the estimated mean numerical rating scale of pain intensities compared to that at baseline in both groups (P < 0.001). Any adverse events that occurred were minor and temporary. Conclusions: Percutaneous epidural neuroplasty using a balloon catheter may be an alternative treatment option for patients with chronic LSS, regardless of accompanying DLS, who have had failed conservative management.

A Comparative Study to Evaluate a Simple Method for the Management of Postoperative Bleeding Following Palatoplasty

  • Rossell-Perry, Percy;Schneider, William J.;Gavino-Gutierrez, Arquimedes M.
    • Archives of Plastic Surgery
    • /
    • 제40권3호
    • /
    • pp.263-266
    • /
    • 2013
  • Bleeding, is one of the most common postoperative complications after palatoplasty in patients with cleft palate. The purpose of this article is to present our experience using a Foley catheter balloon for perioperative palatoplasty bleeding management. A retrospective data analysis was performed for all cases of palatoplasty performed by the author from 1999 to 2012 that experienced postoperative hemorrhage. These patients were managed by utilizing posterior nasal compression with a Foley catheter balloon for the period 2006 to 2012. We have compared two methods (we use before 2006 the reoperative method) with regards to the later development of palatal fistulae and cases with reoperative hemostasis. The study found no statistically significant differences between the conventional and proposed method in relation to the development of palatal fistulae (P=0.7). These findings suggest that nasal packing using a Foley balloon is a safe and effective method for postoperative bleeding control after palatoplasty in patients with cleft palate.

풍선 확장술에서 식도파열의 진단을 위한 압력분석 시스템의 구성 (A Development of the Balloon Pressure Analysis System for the Diagnosis of Esophageal Ruptures)

  • 신동익;송호영;허수진
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.428-431
    • /
    • 1997
  • This study is the basic research on esophageal balloon dialation with automatic detection of the pressure change in the balloon and analysis using personal computer. In conventional method, the esophageal stricture is cured by surgically. Recently, balloon dialation method has been proposed and is popularized. In balloon dialation, detecting esophageal rupture is very important. When using radiological investigation, the leak of contrast medium is very dangerous. In proposed method, the detection of esopageal rupture can be peformed by detecting and analyze the pressure change of dialation balloon. Experimental system is composed of balloon catheter, pressure pump, pressure sensor, A/D converter and PC.

  • PDF

Inferior Blow-Out Fracture Reduction Using Two Urinary Balloon Catheters

  • Jo, Eun Jun;Kim, Jong Hwan;Yang, Ho Jik
    • 대한두개안면성형외과학회지
    • /
    • 제16권3호
    • /
    • pp.114-118
    • /
    • 2015
  • Background: The reduction of orbital blowout fracture primarily aims to normalize the extra-ocular movement by returning the herniated orbital soft tissue into the original position, and to prevent enophthalmos by normalizing the orbital cavity volume. We introduce a balloon catheter-assisted orbital floor reduction technique. Methods: A retrospective review was performed for all patients with orbital floor fracture who underwent the technique described in the main body of this text. Medical records were reviewed for demographic data, clinical presentation and course, degree of enophthalmos, intraorbital volume on computed tomography scan, and postoperative outcomes. The enophthalmos and intraorbital volume of the injured site were compared to the uninjured eye and orbit. Results: The review identified 14 patients (11 male, 3 female). The mean preoperative difference in en-exopthalmos was 2.13 mm, while the mean orbital volume was 116%. The mean postoperative difference in en-exophthalmos had improved to 0.61 mm with a mean orbital volume of 101.85%. At the time of catheter removal at 10 days, three patients experienced diplopia (n=1), extra-ocular movement disorder (1), or enophthalmos (1). All of these had resolved by the 6-month follow-up visit. Conclusion: Balloon catheter-assisted reduction of the orbital floor fractures was associated with improvements in intraorbital volume and enopthalmos in the 14 patients. Notable complications included diplopia, enophthalmos, and limited extra-ocular movement, all of which were transient in the early postoperative period and had resolved by 6-month follow up.

포가티 카테터를 이용한 유리조직 전이술 시 수술 중 혈전 및 연축의 치료 (Treatment of Intraoperative Thrombosis and Spasm in Free Tissue Transfers Using the Fogarty Catheter)

  • 이승렬;윤영묵;오상하
    • Archives of Plastic Surgery
    • /
    • 제35권2호
    • /
    • pp.159-164
    • /
    • 2008
  • Purpose: Microvascular free tissue transfer has become a reliable technique for the reconstruction of complex wounds. Occasionally, unexpected intraoperative thrombosis and/or spasm of recipient artery might be annoying problems even for the technically competent microvascular surgeons. If such problems are not treated properly, they will inevitably cause to flap failure. Methods: From January 2006 to February 2007, soft tissue reconstructions by free tissue transfers were performed on 21 patients having complex defects in the lower extremity. Although segmental revision and various pharmacologic agents were repeatedly applied, arterial occlusions were not managed in 6 cases. For removal of thrombi and release of spasm, Fogarty No. 2 or No. 3 catheters were inserted into the lumen to the proximal recipient artery. Its balloon was then inflated after passing through a resistant area. Next, the catheter was gently withdrawn backward. Results: After the Fogarty catheter was inserted two or three times, the pulsatile arterial flow was restored. When the catheter was inserted into the lumen, a feeling of resistance existed in a 5-10cm more proximal portion that could not be easily accessed from the vascular end. After the reestablishment of blood flow, successful anastomoses were achieved and immediate rethrombosis or spasm did not occur. No long-term sequelae associated with balloon trauma to the arterial wall were observed. Conclusion: The use of the Fogarty catheter can be an effective method in treating pedicle thrombosis and spasm. This is a very simple and rapid technique that offers microvascular surgeons another option to increase the success rate of microvascular anastomosis in free tissue transfers.

Positioning of Resuscitative Endovascular Balloon Occlusion of the Aorta Catheter: A Case of an Elderly Patient with Concomitant Chest and Pelvic Injury after Blunt Trauma

  • Noh, Dongsub;Yun, Jeongseok;Chang, Ye Rim
    • Journal of Trauma and Injury
    • /
    • 제33권3호
    • /
    • pp.186-190
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been increasingly used in recent years as a resuscitative adjunct for trauma patients with life-threatening non-compressible torso hemorrhage. By blocking the aorta temporarily with an inflated balloon, REBOA preserves cerebral and coronary perfusion while diminishing exsanguination below the balloon, thereby providing time for resuscitation and definitive bleeding control. When determining the occlusion zone during the REBOA procedure, factors such tortuosity of the aorta, co-occurring minor chest injuries, and the severity of shock must be considered, as well as the main injury site. This paper describes a case of high Zone I REBOA in an elderly patient with a tortuous aorta who had concomitant injuries of the chest and pelvis.

Educational Simulation Videos for Performing Resuscitative Endovascular Balloon Occlusion of the Aorta

  • Chang, Sung Wook;Kim, Dong Hun;Chang, Ye Rim
    • Journal of Trauma and Injury
    • /
    • 제33권3호
    • /
    • pp.140-143
    • /
    • 2020
  • Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been accepted as an adjunct procedure for non-compressible torso hemorrhage in patients with hemorrhagic shock. With appropriate indications, REBOA should be performed for resuscitation regardless of the physician's specialty. Despite its effectiveness in traumatized patients with hemorrhagic shock, performing REBOA has been challenging due to physicians' lack of experience. Even though training in endovascular skills is mandatory, many physicians cannot undergo sufficient training because of the limited number of endovascular simulation programs. Herein, we share simulation video clips, including those of a vascular circuit model for simulation; sheath preparation; long guidewire and balloon catheter preparation; ultrasound-guided arterial access; sheath insertion or upsizing; and balloon positioning, inflation, and migration. The aim of this study was to provide educational video clips to improve physicians' endovascular skills for REBOA.