• Title/Summary/Keyword: Ballast specification

Search Result 14, Processing Time 0.023 seconds

A Reliability Model of Electronic Ballasts for Fluorescent Lamp (형광등용 전자식 안정기의 신뢰성 모형)

  • Jeon, Tae-Bo
    • Journal of Korean Society for Quality Management
    • /
    • v.35 no.2
    • /
    • pp.27-36
    • /
    • 2007
  • A study to build a reliability model of electronic ballasts for the fluorescent lamp has been performed in this study. We selected the widely being used specification, MIL-HDBK-217 for the study. We briefly reviewed the basic concepts of the electronic ballast with the selected reliability specification. We then developed a reliability model for the ballast using MIL-HDBK-217 and predicted the reliability. We further provided some guides which should be considered in future model development.

A Reliability Model of Electronic Ballasts for the Fluorescent Lamp using MIL-HDBK-217 (MIL-HDBK-217을 이용한 형광등용 전자식 안정기의 신뢰성 모형)

  • Jeon, Tae-Bo
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 2006.11a
    • /
    • pp.327-332
    • /
    • 2006
  • A study to build a reliability model of electronic ballasts for the fluorescent lamp has been performed in this paper. We selected the widely being used specification, MIL-HDBK-217 for the study. We briefly reviewed the basic concepts of the electronic ballast with the selected reliability specification. We then developed a reliability model for the ballast using MIL-HDBK-217 and predicted the reliability.

  • PDF

Developing Track Ballast Characteristic Guideline In Order To Evaluate Its Performance

  • Sadeghi, J.M.;Zakeri, J. Ali;Najar, M. Emad Motieyan
    • International Journal of Railway
    • /
    • v.9 no.2
    • /
    • pp.27-35
    • /
    • 2016
  • In spite of recent advances in ballasted railway track, the correct choice of ballast for rail track is still considered critical because aggregates progressively deteriorate under traffic loading and environmental exposures. Various ballast requirements, functions and duties have been defined by researchers, railway companies and countries' regulations even though it needs to be integrated to make following proper decision during track operation and maintenance. A proper understanding of ballast properties and suitable tests are prerequisites for minimizing maintenance costs. This paper presents a capable classification for ballast characteristics which need to be investigated beforehand to such a way, firstly to assign ballast functions, secondly need to clarify ballast requirements, thirdly to map appropriate tests to evaluate ballast characteristics and then it must be such that if ballast cannot carry out one of these duties, be able to call there is ballast defect. The paper is structured in order to achieve these objectives.

Effects of normal stress, shearing rate, PSD and sample size on behavior of ballast in direct shear tests using DEM simulation

  • Md Hussain;Syed Khaja Karimullah Hussaini
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.475-486
    • /
    • 2023
  • Ballast particles have an irregular shape and are discrete in nature. Due to the discrete nature of ballast, it exhibits complex mechanical behaviour under loading conditions. The discrete element method (DEM) can model the behaviour of discrete particles under a multitude of loading conditions. DEM is used in this paper to simulate a series of three-dimensional direct shear tests in order to investigate the shear behaviour of railway ballast and its interaction at the microscopic level. Particle flow code in three dimension (PFC3D) models the irregular shape of ballast particles as clump particles. To investigate the influence of particle size distribution (PSD), real PSD of Indian railway ballast specification IRS:GE:1:2004, China high-speed rail (HSR) and French rail specifications are generated. PFC3D built-in linear contact model is used to simulate the interaction of ballast particles under various normal stresses, shearing rate and shear box sizes. The results indicate how shear resistance and volumetric changes in ballast assembly are affected by normal stress, shearing rate, PSD and shear box size. In addition to macroscopic behaviour, DEM represents the microscopic behaviour of ballast particles in the form of particle displacement at different stages of the shearing process.

Field Test to Investigate Dynamic Characteristics of Steel Plate Girder Railway Bridges without Ballast (무도상 판형교의 동적거동특성 분석을 위한 실험적 연구)

  • 최진유;오지택;김현민;이상배
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.678-683
    • /
    • 2002
  • Field measurements were conducted to analysis dynamic characteristics of existing steel plate girder railway bridges without ballast. Three bridges which have 9m, 12m, 18m span length in Kyoung-Bu and Ho-Nam Line were selected for test. According to the each bridge, dynamic vertical deflections and vertical and horizontal accelerations were measured. Natural frequencies, vertical deflections and accelerations obtained from field tests were compared with the limit value specified in the UC, Japanese and Korean railway bridge specification.

  • PDF

A Design of Electronic Ballast for 400[W] High Pressure Sodium Lamp Using IsSPICE (IsSPICE를 이용한 400[W] 고압나트륨 램프용 전자식 안정기 설계)

  • Kong, Eung-Seok;Shin, Dae-Chul;Choi, Choung-Moon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.27-34
    • /
    • 2004
  • In this paper, we designed the electronic ballast for the 400[W] hight pressure sodium lamp using the half-bridge inverter Inductance and capacitance in the proposed equivalent LC series resonant circuit are calculated theoretically. We performed the simulation of the LC series half-bridge inverter circuit using the IsSPICE and the electronic ballast for the high pressure sodium lamp were implemented for verifing the simulation results. In the experimental results, the specification of the implemented electronic ballast are almost same with the simulated one. The experimental results show the good performance as PF 99.3[%], $A_{THD}$ 10.01[%], lamp efficiency 119[lm/W] at the output 400[W].].

Study on Effectiveness of Selection for Railway Ballast : Case Study on A Quarry in northen France (철도 밸러스트 선정 효율성에 대한 고찰 : 프랑스 채석장에 대한 사례연구)

  • Woo, Ik
    • Tunnel and Underground Space
    • /
    • v.25 no.6
    • /
    • pp.487-495
    • /
    • 2015
  • The specification for selecting railway ballast in France is introduced in this study and the effectiveness of selection for railway ballast is studied for the case of a quarry located in northen France. The quality of railway ballast is, in general, estimated depending on the grain distribution and mainly of the resistance against abrasion. The resistance against abrasion is obtained by both Los Angeles abrasion test and Micro Deval test, which determine the ballast quality suitable whether for high speed railway or classical railway. This study analyzed the correlation between the abrasion index obtained from the abrasion tests for the aggregates sampled at three different stages among ballast production procedure at the quarry. A high correlation is determined between Los Angeles Abrasion index (LA) and Micro Deval index (MDA) and also between abrasion indices of different aggregates. Particularly, this correlation between the abrasion indices allows to estimate the quality of ballast at the final stage from the aggregates at the site in a quarry within the margin of error.

Field Test to Investigate Lateral Dynamic Characteristics of Steel Plate Girder Railway Bridge without Ballast (무도상 판형교의 횡방향 동적거동특성 분석을 위한 실험적 연구)

  • Oh Ji Taek;Kim Hyun Min;Park Ok Jung;Park Chan
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.591-595
    • /
    • 2003
  • Field measurements were conducted to analysis lateral dynamic characteristics of existing steel plate girder railway bridges without ballast. Three bridges which have 9m, 12m, 18m span length in Kyoung-Bu Line were selected for test. According to the each bridge, dynamic lateral deflections and accelerations were measured. From the present study, it was observed that dynamic lateral amplification phenomena caused by a fluctuation of lateral force were occurred under the current running circumstances. Lateral deflections were occurred below than that specified in Korean railway bridge specification, but lateral accelerations is a match for vertical accelerations. From now on, it is in need a plan to reduce lateral accelerations for the conventional railway Line speed up.

  • PDF

Numerical Analysis to Investigate Dynamic Characteristics of Steel Plate Girder Railway Bridges without Ballast (무도상 판형교의 동적거동특성 분석을 위한 해석적 연구)

  • 최진유;오지택;김현민;김영국
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1080-1085
    • /
    • 2002
  • A dynamic characteristics of existing steel plate girder railway bridges without ballast were investigated from the finite element analysis. Span lengths, types of vehicle and running speeds are selected as parameters for analyses. For more exact analysis, it was adopted that 3-dimensional bridge models and wheel loads were produced by averaging field measured wheel loads of running vehicles at various speeds. Dynamic vertical deflections, dynamic amplification factors and vertical accelerations of bridges having 9m, 12m and 18m span length were investigated and compared with the limit values specified in Korean railway bridge specification.

  • PDF

Modal Tests of Railway Bridges considering the Type of Track Structures (철도교량 동특성 분석을 위한 궤도형식별 모달 테스트)

  • Kim, Sung-Il;Yu, Jin-Young;Mun, Je-U;Hong, Seong-Mo;Kim, Jong-Tae
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.101-108
    • /
    • 2008
  • The dynamic behavior of railway bridges originates from dynamic properties of various spans and structural types. As a result, the exact estimation of dynamic properties of the railway bridge can produce the exact estimations of dynamic performances of the railway bridge. The damping ratio affects the dynamic reponses of the railway bridge in the vicinity of the critical speed seriously. Eurocode, National Annex of each European country and Japan have their own specification for the damping ratio for the estimation of dynamic performance of railway bridges. In our case, the specification for Honam high speed railways follows the Eurocode. In the present study, for the verification and regulation of the damping ratio and investigation of various dynamic properties, modal tests of various structural types are performed. In addition, for the investigation of effects of track structures on the dynamic property of the bridge, ballast track and concrete track are installed and tested.

  • PDF