• 제목/요약/키워드: Ballast for Fluorescent Lamp

검색결과 115건 처리시간 0.026초

전자식 안정기를 위한 형광램프 모델링 (Modeling of fluorescent Lamp for Electronic Ballast)

  • 이진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.106-109
    • /
    • 1999
  • This paper introduces a fluorescent lamp model based on gas discharge phenomena. This model was applied to electronic ballast. Simulation and experimental results were presented to verify the feasibility of the modeling.

  • PDF

콤팩트 형광램프용 전자식 안정기의 주파수 제어에 의한 온도보상 (Compensation of temperature characteristics by frequency control of an electronic ballastfor a compact fluorescent lamp)

  • 송상빈;곽재영;여인선
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권1호
    • /
    • pp.27-33
    • /
    • 1999
  • Compact fluorescent lamps are very sensitive to the variation of ambient temperature. This paper investigates the temperature characteristics of a 15[W] compact fluorescent lamp, and compensates the variation of light output by frequency control of its electronic ballast. Circuit parameters for the inverter of the electronic ballast are obtained by analyzing the R-L-C equivalent circuit for the inverter and the lamp. The optimum ratio of the two capacitance($C_1$/$C_2$), which are connected with the lamp in series and in parallel, respectively, is determined which consideration of the temperature variation within a range of 10~35[$^{\circ}C$]. As a result a value of 10 for the ratio is obtained at an operating frequency of 57[kHz], and with this value the frequency control works well for temperature compensation. Its validity is verified by investigating light output stabilization characteristics resulting from frequency control of the lamp at various temperatures.

  • PDF

Novel Crest Factor Improvement of Electronic Ballast-Fed Fluorescent Lamp Current Using Pulse Frequency Modulation

  • Song Joong-Ho;Choy Ick;Choi Ju-Yeop
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.98-103
    • /
    • 2001
  • In case that electronic ballast employing a valley-fill passive power factor correction (PFC) circuit is used for feeding fluorescent lamps, a new method to reduce crest factor of the lamp current is studied in this paper. In order to reduce crest factor to lower value, a pulse frequency modulation technique based on the waveform of the dc-link voltage which is predetermined by the passive PFC circuit, is taken into the switching control action of the electronic ballast. An equation-based analysis between the crest factor of lamp current and the effect of varying the inverter switching frequency is comprehensively performed.

  • PDF

페라이트 비드를 이용한 다등용 전자식 안정기 설계 (The Design of Electronic Ballast for Multiple Lamps Using the Ferrite Bead)

  • 고석철;이재;임성훈;최명호;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.589-592
    • /
    • 2001
  • In this paper, Electronic ballast for multiple fluorescent lamps based on the use of ferrite beads are presented. The use of this system in place of the conventional electromagnetic ballast results in lower power consumption and reduced maintenance cost, because the electronic system has higher efficiency and longer lamp lifetime than the electromagnetic ballast. In comparison with the conventional electronic ballast. The proposed system presents a significant reduction of cost. This reduction becomes were meaningful with the growing of the lamp number. The description of the lighting system, We show that the proposed model can be applied to multiple lamps electronic ballast by simulation processes.

  • PDF

페라이트 비드를 이용한 다등용 전자석 안정기 설계 (The Design of Electronic Ballast for Multiple Lamps Using the Ferrite Bead)

  • 고석철;이재;임성훈;최명호;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.589-592
    • /
    • 2001
  • In this paper, Electronic ballast for multiple fluorescent lamps based on the use of ferrite beads are presented. The use of this system in place of the conventional electromagnetic ballast results in lower power consumption and reduced maintenance cost, because the electronic system has higher efficiency and longer lamp lifetime than the electromagnetic ballast. In comparison with the conventional electronic ballast. The proposed system presents a significant reduction of cost. This reduction becomes were meaningful with the growing of the lamp number. The description of the lighting system, We show that the proposed model can be applied to multiple lamps electronic ballast by simulation processes.

  • PDF

형광등용 전자식 안정기의 신뢰성 모형 (A Reliability Model of Electronic Ballasts for Fluorescent Lamp)

  • 전태보
    • 품질경영학회지
    • /
    • 제35권2호
    • /
    • pp.27-36
    • /
    • 2007
  • A study to build a reliability model of electronic ballasts for the fluorescent lamp has been performed in this study. We selected the widely being used specification, MIL-HDBK-217 for the study. We briefly reviewed the basic concepts of the electronic ballast with the selected reliability specification. We then developed a reliability model for the ballast using MIL-HDBK-217 and predicted the reliability. We further provided some guides which should be considered in future model development.

MIL-HDBK-217을 이용한 형광등용 전자식 안정기의 신뢰성 모형 (A Reliability Model of Electronic Ballasts for the Fluorescent Lamp using MIL-HDBK-217)

  • 전태보
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 추계 학술대회
    • /
    • pp.327-332
    • /
    • 2006
  • A study to build a reliability model of electronic ballasts for the fluorescent lamp has been performed in this paper. We selected the widely being used specification, MIL-HDBK-217 for the study. We briefly reviewed the basic concepts of the electronic ballast with the selected reliability specification. We then developed a reliability model for the ballast using MIL-HDBK-217 and predicted the reliability.

  • PDF

Telcordia를 이용한 형광등용 전자식 안정기의 신뢰성 모형 수립 (Reliability Modeling of Electronic Ballasts for the Fluorescent Lamp Using Telcordia)

  • 전태보
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 춘계학술대회
    • /
    • pp.69-75
    • /
    • 2006
  • As the level of technology and the standard of living improve, product reliability plays an Increasingly significant role. This study has been performed to build a reliability model of electronic ballasts for the low wattage fluorescent lamp. Telcordia SR-332, one of the most widely used reliability specifications, was selected for the model development. We briefly reviewed the basic concepts of the electronic ballast. We then developed a reliability model for the ballast using SR-332 concepts and the reliability has been examined.

  • PDF

형광등용 전자식 안정기의 신뢰성 평가를 위한 접근 (An Approach to Evaluate Reliability of Electronic Ballasts for the Fluorescent Lamp)

  • 전태보;장목순;박종연
    • 한국품질경영학회:학술대회논문집
    • /
    • 한국품질경영학회 2006년도 추계 학술대회
    • /
    • pp.333-338
    • /
    • 2006
  • A simple but practical approach to evaluate the reliability of electronic ballasts for the low wattage fluorescent lamp has been presented in this study. We briefly reviewed the basic concepts of the electronic ballast. We then proposed a simple model and evaluated the reliability of the ballast using computer simulation.

  • PDF

압전 변압기 특성을 이용한 35W급(T5급) 형광등용 안정기 구동에 관한 연구 (A Study on the Driving of Ballast for 35W Class (T5 Class) Fluorescent Lamp using a Piezoelectric Transformer Characteristic)

  • 황락훈
    • 한국산학기술학회논문지
    • /
    • 제9권3호
    • /
    • pp.638-644
    • /
    • 2008
  • 슬립램프의 응용은 소형으로 디자인되는 원리를 이행하므로 작은 사이즈의 전자식 안정기가 요구된다 하지만 기존의 $50{\sim}60Hz$에서 동작되는 자기석 안정기들은 현저한 플리커(깜빡거림) 현상, 높은 손실, 큰 파고율 그리고 무거운 단점을 가지고 있다. 본 연구에서는 이러한 문제들을 해결하기 위해서 35W급(T5급) 형광등을 동작시키기 위한 제안된 새로운 타입으로 구성된 전자식 안정기로 정류기, 역률개선, 직렬 공진 하프 브리지 인버터 그리고 압전 변압기를 구성한 시스템을 제안하였다. 이 같은 압전 변압기를 이용한 전자식 안정기 구성으로 35급(T5급) 형광등을 성공적으로 동작시킬 수 있었다. 제안된 전자식 안정기를 약 $75{\sim}79kHz$의 주파수로 구동 시켜서 실험한 결과 25분 구동 후에 형광램프는 시스템 전체 안정기의 역률과 효율은 각각 0.95, 0.86%의 양호한 결과를 얻을 수 있었다.