• Title/Summary/Keyword: Ball-on-3-ball test

Search Result 331, Processing Time 0.027 seconds

FLEXURAL STRENGTH OF IMPLANT FIXED PROSTHESIS USING FIBER REINFORCED COMPOSITE (섬유성 강화 컴포지트를 사용한 임플랜트 고정성 보철물의 굴곡강도)

  • Kang, Kyung-Hee;Kwon, Kung-Rock;Lee, Sung-Bok;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.526-536
    • /
    • 2006
  • Statement of problem : Use of fiber composite technology as well as development of nonmetal implant prosthesis solved many problems due to metal alloy substructure such as corrosion. toxicity, difficult casting, expensiveness and esthetic limit. After clinical and laboratory test, we could find out that fiber-reinforced composite prostheses have good mechanical properties and FRC can make metal-free implant prostheses successful. Purpose : The purpose of this study is to evaluate the flexural strength of implant fixed prosthesis using fiber reinforced composite. Material and methods : 2-implant fixture were placed in second premolar and second molar area in edentulous mandibular model, and their abutments were placed, and bridge prostheses using gold, PFG, Tescera, and Targis Vectris were fabricated. Tescera was made in 5 different designs with different supplements. Group I was composed by 3 bars with diameter 1.0mm and 5 meshes, 2 bars and 5 meshes for Group II, 1 bar and 5 meshes for Group III, and only 5 meshes were used for Group IV. And Group V is composed by only 3 bars. Resin (Tescera) facing was made to buccal part of pontic of gold bridge. All of gold and PFG bridges were made on one model, 5 Targis Vectris bridges were also made on one model, and 25 Tescera bridges were. made on 3 models. Each bridge was attached to the test model by temporary cement and shallow depression was formed near central fossa of the bridge pontic to let 5 mm metal ball not move. Flexual strength was marked in graph by INSTRON. Results : The results of the study are as follows. The initial crack strength was the highest on PFG. and in order of gold bridge Tescera I, Tescera II, Targis vectris, Tescera IV, Tescera III, and Tescera V. The maximum strength was the highest on gold bridge, and in order of PFG, Tescera I, Tescera IV Tescera II, Targis vectris, Tescera III, and Tescera V. Conculsions : The following conclusions were drawn from the results of this study. 1. Flextural strength of implant prosthesis using fiber reinforced composite was higher than average posterior occlusal force. 2. In initial crack strength, Tescera I was stronger than Tescera V, and weaker than PFG. 3. Kinds and number of auxillary components had an effect on maximum strength, and maximum strength was increased as number of auxillary components increased. 4 Maximum strength of Tescera I was higher than Targis vectris, and lower than PFG.

Effect of Anorthite Glass Frit on the Electrical and Adhesion Properties of Photosensitive Silver Paste (Anorthite 글라스 프릿이 첨가된 감광성 은 페이스트의 전기적 특성 및 부착력 특성 평가)

  • Lee, Eun-Heay;Kim, Hyo-Tae;Lim, Jong-Woo;Yoon, Young-Joon;Kim, Jong-Hee;Park, Eun-Tae;Lee, Jong-Myun;Paik, Un-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.21-21
    • /
    • 2009
  • 후막 광식각 기술을 이용하여 형성된 Ag 전극과 LTCC 기판 사이의 접착력을 향상시키기 위하여 무기 바인더로서 anorthite, diopside 및 MLS-62 glass frit을 첨가하여 감광성 Ag paste를 제조하였다. 소성 후의 glass pool effect를 감소시키기 위해 attrition mill을 통하여 미세 glass 분말을 준비하였다. Glass frit은 Ag powder의 5vol%~25vol%의 함량으로 첨가하여 감광성 Ag paste를 제조하였고 패턴 형성 후 $850^{\circ}C$에서 1시간 소결하였다. 전극과 기판 사이의 접착력은 micro-ball shear test 법으로 측정하였으며, Ag 전극 부착력은 glass frit의 함량 증가에 따라 증가하다가 감소하는 경향을 보이는데, 이는 과량의 glass frit 첨가로 인한 전극 내부에 액상 풀의 형성에 기인한 것으로 보여진다. Ag 전극의 면저항은 glass frit의 함량이 증가함에 따라 $0.13m{\Omega}{/\square}$에서 $2.06m{\Omega}{/\square}$까지 증가하는 경향을 나타내었다. 소성 전후의 전극 패턴의-수축율은 $100{\mu}m$의 선폭을 기준으로 glass frit의 첨가랑이 증가할수록 43.3%에서 35.0%로 감소하였으며, 그 결과 최소 선폭 $25{\mu}m$의 미세 전극 패턴의 형성이 가능하였다.

  • PDF

TiN/NiTi 2층형 박막의 두께 변화에 따른 물리적 특성 기초연구

  • Byeon, In-Seop;Yang, Ji-Hun;Kim, Seong-Hwan;Jeong, Jae-In
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.132-132
    • /
    • 2018
  • NiTi 형상 기억 합금은 형상기억 효과 (Shape memory effect) 또는 초탄성 효과 (superelasticity effect)를 나타낸다고 알려져 있다. 대표적으로 Ni:Ti 조성비가 1:1을 갖는 NiTi(니티놀) 합금은 형상기억 및 초탄성 효과가 우수하여 기계 가공 공정뿐만 아니라 우수한 내마모성을 요구하는 공구에 사용하기 적합하다. 하지만 NiTi 박막은 합금과 같은 Damping capacity를 가지고 있지만 비교적 낮은 물리적 특성을 가지고 있다. 본 연구에서는 NiTi 박막의 낮은 물리적 특성을 향상시키기 위하여 TiN과 NiTi의 2층형 박막을 제조하고 각 층의 두께 변화를 조절하여 특성 향상에 대한 기초연구를 진행했다. 타겟은 NiTi (Ni:Ti=48.2:51.8 at.%) 합금 타겟과 Ti 타겟을 사용하였고, 시편과 타겟 간의 거리는 약 10cm 이며, 시편은 기초분석을 위한 SUS304, 물리적 특성 평가를 위한 초경 을 사용하였다. 초경은 실제 공구에서 사용하고 있는 Co함량이 10% 함유된 시편은 선정했다. 시편 전처리는 알코올과 아세톤으로 세척을 실시한 후 진공챔버에 장착하고 ${\sim}10^{-5}Torr$ 까지 진공배기를 실시하였다. 기판 정청은 글로우 방전 방식으로 약 800 V 전압에서 30분간 실시했다. 공정 가스는 Ar와 $N_2$ 혼합가스를 사용하였으며, UBM(Un-Balanced Magnetron) 스퍼터링 소스를 이용하여 2층형 박막을 제조했다. TiN과 NiTi 층의 두께 비율을 0.5, 1 그리고 2 로 변화시켜 코팅했으며, 박막의 총 두께는 약 ${\sim}3{\mu}m$ 이다. 기초분석은 FE-SEM을 통해 두께와 박막 비율을 확인 및 XRD 분석을 통해 박막 정성분성을 실시했다. 2층형 박막의 물리적 특성은 Nanoindentation test, AFM 및 ball on disc를 이용하여 평가했으며, 그 결과 두께 비율 변화에 따라 물리적 특성 변화가 나타남을 확인했다.

  • PDF

AE Characteristic of Polyethylene Pipe under various defects (다양한 결함에 대한 폴리에틸렌 배관의 음향방출 특성)

  • Nam Ki Woo;Lee Si Yoon;Ahn Seok Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.1-7
    • /
    • 2004
  • The polyethylene pipe can use semi-permanent because of the high corrosion resistance with chemical stability. In addition to, there is the merit that is an easy to establish and to maintain. However, as the reason that it is simply degraded when the polyethylene pipe was exposed to the outside, mainly it is used to lay under the ground with low-pressure gas transportation pipe. In this study, the nondestructive evaluation method was used to maintain the integrity of the polyethylene pipe. We simulated the various defects on the polyethylene pipes, and then the AE signal occurred according to the impact test of steel ball was evaluated by the acoustic emission method. From the results, the waveform and dominant frequency could be distinguishing from the defect shapes of polyethylene pipe. Especially, in the case of notch defect, the AE signals occur different by the angle and depth of the notch.

  • PDF

Tele-operation System of Unmaned Fire Truck for Real-time Fire Suppression (실시간 화재진압을 위한 원격조종 무인소방 시스템)

  • Kang, Byoung Hun;Lee, Seung-Chol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2022
  • In this research, we suggest a real-time tele-driving system for unmanned fire truck control using the LTE communication system. The operator located in the safe area could drive the unmaned fire truck by implementing the secure tele-operation in case of the emergencies and disaster situation. A prototype of the unmaned fire truck was developed with a fire canon, a high pressure pump, a ball valve and a horse reel. The effect of time delay and FPS was quantified depending on the image sizes and the effective system for realtime tele-operation was suggested. To verify the suggested system, the test was performed between an operator and an unmanned fire truck which is approximately 30km apart. In this research, the immersion tele-driving system is suggested for real-time fire suppression with a 120ms time delay using LTE communication.

Effect of Reflow Number and Surface Finish on the High Speed Shear Properties of Sn-Ag-Cu Lead-free Solder Bump (리플로우 횟수와 표면처리에 따른 Sn-Ag-Cu계 무연 솔더 범프의 고속전단 특성평가)

  • Jang, Im-Nam;Park, Jai-Hyun;Ahn, Yong-Sik
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.3
    • /
    • pp.11-17
    • /
    • 2009
  • The drop impact reliability comes to be important for evaluation of the life time of mobile electronic products such as cellular phone. The drop impact reliability of solder joint is generally affected by the kinds of pad and reflow number, therefore, the reliability evaluation is needed. Drop impact test proposed by JEDEC has been used as a standard method, however, which requires high cost and long time. The drop impact reliability can be indirectly evaluated by using high speed shear test of solder joints. Solder joints formed on 3 kinds of surface finishes OSP (Organic Solderability Preservation), ENIG (Electroless Nickel Immersion Gold) and ENEPIG (Electroless Nickel Electroless Palladium Immersion Gold) was investigated. The shear strength was analysed with the morphology change of intermetallic compound (IMC) layer according to reflow number. The layer thickness of IMC was increased with the increase of reflow number, which resulted in the decrease of the high speed shear strength and impact energy. The order of the high speed shear strength and impact energy was ENEPIG > ENIG > OSP after the 1st reflow, and ENEPIG > OSP > ENIG after 8th reflow.

  • PDF

Health Problem of the Middle-Aged Women (종합 건강검진 과정에서 나타난 일부 중년기 여성의 건강문제)

  • 성미혜
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.2
    • /
    • pp.258-270
    • /
    • 1999
  • This study was carried out to offer the basic data for more qualitative lives of the middle-aged women through their health maintenance and control. So, the researcher reviewed and analyzed the health problems of the middle-aged women, the differences of main symptoms in each subject, positive ratcs in screening tests, the difference of screening tests with age and the correlation of obesity and blood pressure with screening tests. All subjects were 218 women(40-59years) who had a check-up at a comprehensive health check-up center in K University Hospital in Seoul from July 1, 1998 to August 31. 1998. Questionaires were developed to get subjects, general characteristics. main symptoms, medical examination and diagnosed disease by the researcher referring through the questionaires of comprehensive health check-up center and the medical recorders were used as a tool of study. The researcher analyzed the data with SPSS PC+ ; the distribution of the subjects, general characteristics and main symptoms with percentage : the difference between main symptoms and screening tests with X$^2$-test, ANOVA. The results are as follows. 1) Among the age distribution, most were 40-45 years old and unemployed. 2) The most common complaints were indigestion in digestive system, cough in respiratory system, heart beat in cardiovascular system, general sweat in endocrine system. edema in urinary system, easy bruise in hematologic system, backache in musculoskeletal system, headache in psychoneurologic system, lochia in gynecology, itch in dermatology system, eye ball pain in visual system and tinnitus in auditory system. 3) In main symptoms according to age, the 40-45 age group had a higher rate of complaints in digestive system and gynecology than other age group ; the 46-49 age group in endocrine system. 4) The main symptoms according to diagnosis had no difference statistically. 5) The screening tests which showed high rates of abnormality were mammography(the highest), abdominal ultrasonography, upper gastrointestinal series/gastrofiberscopy, PFT. In all age group the highest rate of abnormality was seen in mammography. 6) In screening tests according to age. the 46-49 age group showed higher positive rates of pap smear, blood sugar test, urine test than any other age group ; the 50-55 age group showerd higher positive rates of obesity, BP, chest X-ray, abdominal ultrasonography, ESR, SGOT, CRP and urine micro. 7) In correlation of obesity with screening test, the obesity group showed higher positive rates of blood pressure, chest X-ray, abdominal ultrasonography, HCT and CRP than the normal weight group. 8) In correlation of blood pressure with screening test, the hypertension group showed higher positive rate of obesity, chest X-ray, abdominal ultrasonography, pap smear and blood sugar than the normal blood pressure group. In conculusion, the middle-aged women have various physical symptoms and affected by age. The obesity and BP have an important effect on the health of the middle aged women. Therefore, this study is considered significant as data for qualitative lives of the middle-aged women playing an important part of family health care by catching of their health problem complaints for prevention of disease and promotion of health.

  • PDF

Treatment of Spent ion-Exchange Resins from NPP by Supercritical Water Oxidation(SCWO) Process (초임계수 산화공정에 의한 원전 폐수지 처리기술)

  • Kim, Kyeong-Sook;Son, Soon-Hwan;Song, Kyu-Min;Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.7 no.3
    • /
    • pp.175-182
    • /
    • 2009
  • The spent cationic exchange resins and anionic exchange resins were separated from mixed spent exchange resins by a fluidized bed gravimetric separator. The separated resins were identified by an elemental analysis and thermogravimetric analysis. The each test sample was prepared by diluting the slurry made by wet ball milling the cationic exchange resins and the anionic exchange resins separated as a spherical granular form for 24 hours. The resulting test samples showed a slurry form of less than $75{\mu}m$ of particle size and 25,000ppm of $COD_{cr}$. The decomposition conditions of each test samples from a thermal power plant were obtained with a lab-scale(reactor volume : 220mL) supercritical water oxidation(SCWO) facility. Then pilot plant(reactor volume : 24 L) tests were performed with the test samples from a thermal power plant and a nuclear power plant successively. Based on the optimal decomposition conditions and the operation experiences by lab-scale facility and the pilot plant, a commercial plant(capacity : 150kg/h) can be installed in a nuclear power plant was designed.

  • PDF

The heat transfer characteristics of viscoelastic non-newtonian fluids in the entrance region of circular tube flows (원형관속을 유동하는 점탄성 유체의 입구 영역 열전달 특성에 관한 연구)

  • 엄정섭;황태성;유상신
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.1032-1043
    • /
    • 1989
  • The heat transfer characteristics of the drag reducing polymer solutions are investigated experimentally in the thermal entrance region of circular tube flows. Fluids used in experiments are the aqueous solutions of high molecular polymer, polyacrylamide Separan AP-273 and the range of polymer concentrations is from 20 to 1000 wppm. Two stainless steel tubes with inside diameter 8.5mm(L/D=712) and 10.3mm(L/D=1160) are used for the heat transfer flow loops. The flow loop is set up to measure friction factors and heat transfer coefficients of test sections in two different modes; the recirculating flow system and once-through flow system. The test tubes are heated directly by electricity to apply the constant heat flux boundary conditions to the wall. Three different types of adaptors are used to observe the effects of the upstream flow conditions of the heat transfer test sections. The viscosity and characteristic relaxation time of the test fluids circulating in the flow system are measured by the capillary tube viscometer and falling ball viscometer at regular time intervals. The installed adaptors exhibit slight effect on the entrance heat transfer of Newtonian fluid. However, no noticeable effects are observed for the entrance heat transfer of the drag reducing fluids. The order of magnitude of the thermal entrance lengths of the drag reducing fluids which follow the minimum friction asymptote is much longer than that of Newtonian fluids in turbulent flows. A new dimensionless parameter, the viscoelastic Graetz number, is defined and all the experimental data are recasted in terms of the viscoelastic Graetz number. The local Nusselt number of the viscoelastic fluids is represented as a function of flow behavior index n and the viscoelastic Graetz number. As degradation continues the viscosity and the characteristic relaxation time of the testing fluids decrease. Weissenberg number defined by the relaxation time and D/V appears to be a proper dimensionless parameter in describing degradation effects on heat transfer of the viscoelastic fluids.

A FLUOROSCOPIC STUDY ON THE STABILITY OF SKIN REFERENCE POINTS DURING JAW OPENING AND CLOSING MOVEMENT (방사선 투시를 이용한 개폐구 운동에 따른 수직 고경 계측점의 안정성에 관한 연구)

  • Ahn, Hyung-Jun;Kim, Chang-Whe;Kim, Yung-Soo;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.516-530
    • /
    • 1999
  • The current clinical technique for occlusal vertical dimension recording is based on marking the skin reference points on the patient's face and measuring between these points using caliper-like device. And it is difficult to achieve reliable measurements by this technique because of movable soft tissue. The purpose of this study is to reveal the stability of skin reference points by comparing the relative movement between extra-oral skin reference points and intra-oral reference points using X-ray fluoroscope. 10 test subjects were divided into 2 groups : Group I (natural dentition) and Group II (denture-wearer whose vertical dimension was lost) and Group III consists of identical test subjects to Group II with their upper denture removed and record base inserted. Attaching the 3 mm diameter steel ball to nose tip, lower lip, chin and to existing denture (or record base), fluoroscopic examination and recording were taken during 2 jaw opening and closing movements. After subsequent digitization using personal computer, 1219 still pictures with 0.1 second interval were made. Using the 2 dimensional graphic software, measurements between reference points were executed. Dividing the entire jaw movement into 3 ranges (total, 1st half opening, 2nd half opening), rate of movement and relative movement between extra-oral and intra-oral reference points were calculated and statistically analyzed. The results of this study are as follows. 1 Within the same experimental group, no statistical difference was found in the stability of skin reference between lower lip point and chin point during total range of jaw opening and closing movement (p>.05) 2. In the first half range of jaw opening, statistical difference was found between Group I (natural dentition) and Group II (denture wearer) (p<.05) Group I has greater skin reference stability than Group II. 3. In the first half range of jaw opening, statistical difference was found between Group I and Group III (record base wearer) (p<.05). Group I has greater skin reference stability than Group III. 4. In the first half range of jaw opening, no statistical difference was found in the stability of skin reference between Group II and Group III (p>.05). 5. In the second half range of jaw opening, no statistical difference was found in the stability of skin reference between any experimental groups (p>.05). 6. In patients with their occlusal vertical dimension lost, employing other measuring references rather than skin is recommended because of low stability.

  • PDF