• Title/Summary/Keyword: Balanced detection

Search Result 74, Processing Time 0.029 seconds

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.4
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

Synchronous Generator Protection using Fault Currents (고장전류를 이용한 동기 발전기 보호)

  • Park, Cheol-Won;An, Jun-Yeong;Lee, Sang-Seong;Sin, Myeong-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.399-401
    • /
    • 2006
  • This paper proposes a synchronous generator protection algorithm using Discrete Wavelet Transform for detection of fault currents. The proposed technique is implemented by using the C language and the Wavemenu of MATLAB Toolbox, and consists of normal state and internal fault state. The effectiveness of proposed method is demonstrated by MATLAB simulation package for synchronous generator, which collects the balanced and unbalanced fault currents through simulation.

  • PDF

ISOTOPIC-SPECTRAL DETERMINATION OF CARBON IN HIGH PURITY INORGANIC MATERIALS

  • Lee, V.N.;Nemets, V.M.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.477-480
    • /
    • 1995
  • Isotopic-spectral method [I] was applicated for determination of carbon in silicate materials (pure silica, guartz glasses, geological probs etc.). Isotopic heterogeneous balancing of carbon in gaseous phase and solid samples was carried out at the temperature of $1500-1900^{\circ}K$. Spectroscopic measuring of isotope concentration in a balanced gas was made using the electron-vibrational band heads of CO molecules excited in HF discharge. Limits of detection of carbon concentrations appear to be $n^*10^{-6}$.

  • PDF

A New Control Algorithm for Instantaneous Voltage Sag Corrector (순시전압강하 보상기의 새로운 제어 기법)

  • Lee, Sang-Hoon;Choi, Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

Detection of Maximal Balance Clique Using Three-way Concept Lattice

  • Yixuan Yang;Doo-Soon Park;Fei Hao;Sony Peng;Hyejung Lee;Min-Pyo Hong
    • Journal of Information Processing Systems
    • /
    • v.19 no.2
    • /
    • pp.189-202
    • /
    • 2023
  • In the era marked by information inundation, social network analysis is the most important part of big data analysis, with clique detection being a key technology in social network mining. Also, detecting maximal balance clique in signed networks with positive and negative relationships is essential. In this paper, we present two algorithms. The first one is an algorithm, MCDA1, that detects the maximal balance clique using the improved three-way concept lattice algorithm and object-induced three-way concept lattice (OE-concept). The second one is an improved formal concept analysis algorithm, MCDA2, that improves the efficiency of memory. Additionally, we tested the execution time of our proposed method with four real-world datasets.

Design of A Broadband Bowtie Antenna for RF Spectral Measurements of Alfvén-wave in the KSTAR Tokamak (KSTAR 토카막의 Alfvén파 RF 스펙트럼 측정을 위한 광대역 보우타이 안테나 설계)

  • Woo, Dong Sik;Kim, Sung Kyun;Kim, Kang Wook;Choi, Hyun-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.46-50
    • /
    • 2016
  • During KSTAR plasma experiments, torsional $Alfv\acute{e}n$ waves in the frequency of few GHz or below were detected. To understand this plasma waves during the crash of MHD instabilities, an RF spectrometer has been developed for detection of the radiated RF signals in the KSTAR Tokamak. It has the capability of broadband RF spectral measurement (50 ~ 400 MHz). To detect the broadband RF signals which are radiated from the KSTAR systems, a broadband antenna is the key feature of the RF spectrometer. In this paper, a broadband bowtie antenna for detection of $Alfv\acute{e}n$-waves in the KSTAR Tokamak is presented. Planar-type bowtie antenna is designed and fabricated on an FR4 substrate with thickness of 1.6 mm. The antenna consists of bowtie shaped balanced radiators and broadband planar balun. The antenna is designed to have an input impedance of 50 Ohm, and a taper-shaped balun is adopted for field and impedance matching between 50 Ohm transmission line to 110 Ohm feeding network of balanced radiators. The implemented antenna provides around -3 to 3 dBi of gain for the whole frequency band. The VSWR of the bowtie antenna is less than 12:1 over the frequency bandwidth of 50 to 2000 MHz.

Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement (인체 움직임을 고려한 소형 근접 마이크로파 심박 센서)

  • Yun, Gi-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.10
    • /
    • pp.63-69
    • /
    • 2020
  • In this paper, a small microwave sensor that can be applied to a wearable device is proposed because it can detect the heartbeat signal of a human body moving irregularly at low speed. It consist of balanced microstrip radiation patches in the 2.4 GHz ISM band, self-oscillation detection circuit, and feedback circuit. Based on the theoretical development and simulation, the validity of the proposed structure was confirmed and the manufactured prototype was tested. The board size of the circuit is as small as 65mm × 85㎟, and has a low power consumption of 60mW thanks to the simple RF circuit structure. Finally heartbeat signal has been obtained from a human body moving at low speed (0.5Hz) within a linear distance of 2 to 30mm close to the sensor and a lateral distance of ±20mm.

Design of a Single-Balanced Diode Mixer of FMCW Radar for Vehicle Detection (차량 감지용 FMCW 레이더의 단일 평형 다이오드 주파수 혼합기 설계 및 제작)

  • 한석균
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.12
    • /
    • pp.1335-1340
    • /
    • 2003
  • In this paper, a single balanced diode Mixer for the homodyne FMCW radar to detect distance and velocity of a vehicle target is designed and implemented using a microstrip line and two schottky barrier beam lead diodes. This mixer is optimally designed to have less a conversion loss within the 100 MHz bandwidth with a little LO injection power and a higher LO isolation as soon as possible through the embedded electrical length of microsrtrip line placed between the coupler and diode matching, considering together LO matching condition. The measured results show 6 dB of conversion loss, 23 dB LO/RF isolation and 3 dBm of input 1l dB, respectively.

Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier (3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법)

  • Shin, Hee-Keun;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Shin-Myung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.