• 제목/요약/키워드: Balanced detection

검색결과 75건 처리시간 0.022초

A Compact Ka-Band Doppler Radar Sensor for Remote Human Vital Signal Detection

  • Han, Janghoon;Kim, Jeong-Geun;Hong, Songcheol
    • Journal of electromagnetic engineering and science
    • /
    • 제12권4호
    • /
    • pp.234-239
    • /
    • 2012
  • This paper presents a compact K-band Doppler radar sensor for human vital signal detection that uses a radar configuration with only single coupler. The proposed radar front-end configuration can reduce the chip size and the additional RF power loss. The radar front-end IC is composed of a Lange coupler, VCO, and single balanced mixer. The oscillation frequency of the VCO is from 27.3 to 27.8 GHz. The phase noise of the VCO is -91.2 dBc/Hz at a 1 MHz offset frequency, and the output power is -4.8 dBm. The conversion gain of the mixer is about 11 dB. The chip size is $0.89{\times}1.47mm^2$. The compact Ka-band Doppler radar system was developed in order to demonstrate remote human vital signal detection. The radar system consists of a Ka-band Doppler radar module with a $2{\times}2$ patch array antenna, baseband signal conditioning block, DAQ system, and signal processing program. The front-end module size is $2.5{\times}2.5cm^2$. The proposed radar sensor can properly capture a human heartbeat and respiration rate at the distance of 50 cm.

고장전류를 이용한 동기 발전기 보호 (Synchronous Generator Protection using Fault Currents)

  • 박철원;안준영;이상성;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.399-401
    • /
    • 2006
  • This paper proposes a synchronous generator protection algorithm using Discrete Wavelet Transform for detection of fault currents. The proposed technique is implemented by using the C language and the Wavemenu of MATLAB Toolbox, and consists of normal state and internal fault state. The effectiveness of proposed method is demonstrated by MATLAB simulation package for synchronous generator, which collects the balanced and unbalanced fault currents through simulation.

  • PDF

ISOTOPIC-SPECTRAL DETERMINATION OF CARBON IN HIGH PURITY INORGANIC MATERIALS

  • Lee, V.N.;Nemets, V.M.
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.477-480
    • /
    • 1995
  • Isotopic-spectral method [I] was applicated for determination of carbon in silicate materials (pure silica, guartz glasses, geological probs etc.). Isotopic heterogeneous balancing of carbon in gaseous phase and solid samples was carried out at the temperature of $1500-1900^{\circ}K$. Spectroscopic measuring of isotope concentration in a balanced gas was made using the electron-vibrational band heads of CO molecules excited in HF discharge. Limits of detection of carbon concentrations appear to be $n^*10^{-6}$.

  • PDF

순시전압강하 보상기의 새로운 제어 기법 (A New Control Algorithm for Instantaneous Voltage Sag Corrector)

  • 이상훈;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.172-176
    • /
    • 2001
  • In this paper, a new detection algorithm of faulted voltages under the unbalanced condition and a control algorithm of the instantaneous voltage sag corrector (IVSC) are proposed. To quantify the unbalance under fault conditions, the voltages are decomposed into two balanced three-phase systems using the symmetrical components of positive and negative sequence voltages, which is defined by magnitude factor (MF) and unbalance factor (UF). New control algorithm based on MF and UF values for instantaneous voltage compensation are proposed and verified through the PSCAD/EMTDC simulation and experimental results.

  • PDF

Islanding Detection for PV System Connected to a Utility Grid

  • Han, Seok-Woo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.719-723
    • /
    • 1998
  • Prevention of the islanding phenomena is one of the most important issues because it can damage electrical equipment connected to the utility system and endanger human life. It is very difficult to detect an islanding condition of a power distribution line with conventional voltage of frequency relays, while the output power and the load power of utility interactive PV inverter units are in nearly balanced state in both active power and reactive power. This paper describes the protective equipment that prevents the PV system connected to the utility grid from starting islanding. Both predictive ocntrol method and harmonic injection method are used for a current control and islanding detection for operating safety.

  • PDF

Detection of Maximal Balance Clique Using Three-way Concept Lattice

  • Yixuan Yang;Doo-Soon Park;Fei Hao;Sony Peng;Hyejung Lee;Min-Pyo Hong
    • Journal of Information Processing Systems
    • /
    • 제19권2호
    • /
    • pp.189-202
    • /
    • 2023
  • In the era marked by information inundation, social network analysis is the most important part of big data analysis, with clique detection being a key technology in social network mining. Also, detecting maximal balance clique in signed networks with positive and negative relationships is essential. In this paper, we present two algorithms. The first one is an algorithm, MCDA1, that detects the maximal balance clique using the improved three-way concept lattice algorithm and object-induced three-way concept lattice (OE-concept). The second one is an improved formal concept analysis algorithm, MCDA2, that improves the efficiency of memory. Additionally, we tested the execution time of our proposed method with four real-world datasets.

KSTAR 토카막의 Alfvén파 RF 스펙트럼 측정을 위한 광대역 보우타이 안테나 설계 (Design of A Broadband Bowtie Antenna for RF Spectral Measurements of Alfvén-wave in the KSTAR Tokamak)

  • 우동식;김성균;김강욱;최현철
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.46-50
    • /
    • 2016
  • During KSTAR plasma experiments, torsional $Alfv\acute{e}n$ waves in the frequency of few GHz or below were detected. To understand this plasma waves during the crash of MHD instabilities, an RF spectrometer has been developed for detection of the radiated RF signals in the KSTAR Tokamak. It has the capability of broadband RF spectral measurement (50 ~ 400 MHz). To detect the broadband RF signals which are radiated from the KSTAR systems, a broadband antenna is the key feature of the RF spectrometer. In this paper, a broadband bowtie antenna for detection of $Alfv\acute{e}n$-waves in the KSTAR Tokamak is presented. Planar-type bowtie antenna is designed and fabricated on an FR4 substrate with thickness of 1.6 mm. The antenna consists of bowtie shaped balanced radiators and broadband planar balun. The antenna is designed to have an input impedance of 50 Ohm, and a taper-shaped balun is adopted for field and impedance matching between 50 Ohm transmission line to 110 Ohm feeding network of balanced radiators. The implemented antenna provides around -3 to 3 dBi of gain for the whole frequency band. The VSWR of the bowtie antenna is less than 12:1 over the frequency bandwidth of 50 to 2000 MHz.

인체 움직임을 고려한 소형 근접 마이크로파 심박 센서 (Compact Microwave Heartbeat Proximity Sensor Under Human Body Movement)

  • 윤기호
    • 한국융합학회논문지
    • /
    • 제11권10호
    • /
    • pp.63-69
    • /
    • 2020
  • 본 논문에서는 저속으로 불규칙하게 움직이는 인체의 심박신호를 감지하기 할 수 있어 웨어러블 디바이스에 적용 가능한 소형 마이크로파 센서를 제안하였다. 이를 위해 2.4 GHz ISM 대역에서 평형 구조를 갖는 마이크로스트립 방사 패치들과 자체발진 검출회로 및 귀환회로가 구성되었다. 이론 전개와 시뮬레이션을 통해 제안된 구조의 타당성을 확인하였고 제작된 시제품을 측정하였다. 회로의 보드는 65mm × 85㎟의 작은 크기이며, 간단한 고주파 회로구조로 60mW 수준의 작은 전력을 소모한다. 센서와 직선거리 2~30mm, 측면 좌우 거리 ±20mm 범위 내에서 저속(0.5Hz)으로 움직이는 인체로부터 심박신호를 얻을 수 있었다.

차량 감지용 FMCW 레이더의 단일 평형 다이오드 주파수 혼합기 설계 및 제작 (Design of a Single-Balanced Diode Mixer of FMCW Radar for Vehicle Detection)

  • 한석균
    • 한국전자파학회논문지
    • /
    • 제14권12호
    • /
    • pp.1335-1340
    • /
    • 2003
  • 본 논문에서는 쇼트키 장벽 빔 리드 다이오드와 180$^{\circ}$hybrid coupler를 이용하여 24 GHz 대역에서 동작하는 단일 평형 다이오드 주파수 혼합기를 설계 및 제작하였다. 근거리 차량의 거리와 속도 탐지용 호모다인 FMCW 레이더의 용도에 적합하도록 대역폭은 100MHz이내에서 작은 LO 구동 전력으로 IF 출력 주파수의 변환손실은 가능한 작고 평탄도는 일정하도록 그리고 LO 격리도가 가능한 크도록 하였다. LO 포트의 반사손실, LO 격리도, 변환손실 성능 특성간에 최적의 성능을 위하여 다이오드의 정합회로, 그리고 결합기와 정합회로 사이의 embedded 마이크로스트립 선로를 이용하여 최적화하였다. 제작된 혼합기는 6 dBm의 LO 구동 전력을 가지고 변환손실 6 dB, LO/RF 격리도 23 dB, P1 dB(input)는 3 dBm의 결과를 얻었다.

3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법 (Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier)

  • 신희근;안병웅;김학원;조관열;정신명
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.