• Title/Summary/Keyword: Balance measurement

Search Result 581, Processing Time 0.031 seconds

The Relative·Absolute Reliability and Validity of Step Test in Patients with Chronic Stroke (만성 뇌졸중 환자들의 Step Test의 상대적·절대적 신뢰도와 타당도)

  • Lee, Byoungkwon;Choi, Hyunsoo;An, Seungheon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.43-53
    • /
    • 2017
  • Purpose : To examine the relative absolute reliability and validity of step test (ST) scores in subjects with chronic stroke. Method : A total of 27 stroke patients, participated in the study. A relative reliability index (intraclass correlation coefficient, ICC) was used to examine the level of agreement of inter-rater test-retest reliability for ST score. Absolute reliability indices, including the standard error of measurement(SEM) and the minimal detectable change (MDC), and limits of agreement by Bland and Altman analysis. The validity was demonstrated by spearman correlation of ST score with 10 m Walk Test (10mWT), Fugl-Meyer Assessment-Lower/Extremity (FMA-L/E)-total score, Berg Balance Scale (BBS)-total score. Result : An excellent inter-rater reliability in ST scores was found (paretic, ICC=0.993~0.996; nonparetic, ICC=0.982~0.991). In addition, excellent test-retest reliability was found (paretic, ICC=0.992; nonparetic, ICC=0.967). It all showed acceptable SEM of the ST score as paretic and nonparetic were 0.22 and 0.46 respectively (average score <10 %), and the MDC of the paretic and nonparetic were 0.61 and 1.27 respectively (possible highest score <20 %). indicating that measures had a small and acceptable measurement error. The ST score of paretic and nonparetic were also found to be significantly associated with 10MWT (r=0.77~0.79), FMA-LE scores (r=0.73~0.81) and BBS scores (r=0.72~0.76). Conclusion : The ST showed highly sufficient Inter-rater test-retest agreement and validity and acceptable measurement errors caused by due to chance variation in measurement. It also can be used by clinicians and researchers to assess the balance and mobility performance and monitor functional change in chronic stroke patients.

Parallelism Error Compensation for Force Measurement by Electromagnetic Compensation (전자기력 보상방식의 힘 측정을 위한 평행도 오차 보상)

  • 최인묵;우삼용;김부식
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1051-1054
    • /
    • 2003
  • For micro-weighing, null balance method is widely used in the precision industrial fields, such as biomedicine, semiconductor, chemistry and so on. In order to obtain high resolution and large measurement range simultaneously, the mechanism should be analyzed and optimized. However, large measurement error can be generated according to the mass loading position and this error is called as a corner loading error. The corner loading error is caused by the parallelism error of a Roberval mechanism used to minimize it. The corner loading error is one of the most dominant error sources that should be removed. It is possible to design that the mechanism has no corner loading error theoretically, but the mechanism of the micro weighing device is very difficult to be realized as original design due to assembling and manufacturing error. For the required specification of the device, the precise manufacturing technique under a few $\mu\textrm{m}$ is required for the realization of the design. In this paper, the effects of the parallelism error are analyzed by using Lagrange method and verified by experiment. Also, the compensation mechanism is proposed and the corner loading error is reduced by restoring tile parallelism.

  • PDF

A study on effect in hemiplegic patients in the Hinged Plastic Ankle Foot Orthoses and Solid Plastic Ankle Foot Orthosis (관절형 및 고정형 플라스틱 단하지 보조기가 편마비환자의 정적${\cdot}$동적 균형에 미치는 효과)

  • Lim Ho-Yong;Ahn Yeon-Jun;Kim Yeong-Rok;Park Seung-Kyu
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.161-175
    • /
    • 2004
  • The purpose of this study was to determine the effect of HPAFO(Hinged Plastic Ankle Foot orthosis) and SPAFO(Solid Plastic Ankle Foot Orthosis) on standing balance and step moving in hemiplegia patients. Twenty hemiplegic patients were either inpatient or outpatient at the Rehabilitation medicine, MokPo J General Hospital and JeonJu J Medical Center from July 15, 2002 to September 15, 2002. Patients were able to ambulate independently for at least 10 meters and to stand independently for at least 10 minutes with balance measurement tool. The static balance and dynamic activity measurement was determined by SAKAI active balancer(Japan) with wearing HPAFO and wearing SPAFO. The static balance and dynamic activity analysis was analyzed by independent t-test. The results were as follows: 1. There were no significant difference in body weight bearing percent between wearing HPAFO and wearing SPAFO(p>0.05). 2. There were significant difference in whole path length between wearing HPAFO and wearing SPAFO(p<0.05). 3. There were significant difference in Effective Value Area between wearing HPAFO and wearing SPAFO(p>0.001). 4. There were significant difference in repeated functional time between wearing HPAFO and wearing SPAFO(p>0.001). 5. There were significant difference in cadence between wearing HPAFO and wearing SPAFO(p>0.001). The result of this study showed that wearing HPAFO and wearing SPAFO gave fair amount of improvement to static standing balance and dynamic movement ability of hemiplegic patients. The comparison result showed significant differences in between HPAFO and SPAHFO. The result of this study had a general limitation due to the restricted number of cases. The future study needs more detailed research and comparison with various variance between these two orthoses.

  • PDF

Effect of Sensorimotor Training Using a Flexi-bar on Postural Balance and Gait Performance for Children With Cerebral Palsy: A Preliminary Study

  • Ga, Hyun-you;Sim, Yon-ju;Moon, Il-young;Yun, Sung-joon;Yi, Chung-hwi
    • Physical Therapy Korea
    • /
    • v.24 no.2
    • /
    • pp.58-65
    • /
    • 2017
  • Background: Children with cerebral palsy (CP) have impaired postural control, but critically require the control of stability. Consequently, therapeutic interventions for enhancing postural control in children with CP have undergone extensive research. One intervention is sensorimotor training (SMT) using a Flexi-bar, but this has not previously been studied with respect to targeting trunk control in children with CP. Objects: This study was conducted to determine the effect of SMT using a Flexi-bar on postural balance and gait performance in children with CP. Methods: Three children with ambulatory spastic diplegia (SD) participated in the SMT program by using a Flexi-bar for forty minutes per day, three times a week, for six weeks. Outcome variables included the pediatric balance scale (PBS), trunk control movement scale (TCMS), 10 meter walking test (10MWT), and 3-dimensional movement coordination measurement. Results: The SMT provided no statistically significant improvement in PBS, TCMS, 10MWT, or 3-dimensional movement coordination measurement. However, positive changes were observed in individual outcomes, as balance and trunk control movement were improved. Conclusion: SMT using a Flexi-bar may be considered by clinicians as a potential intervention for increasing postural balance and performance in children with SD. Future studies are necessary to confirm the efficacy of Flexi-bar exercise in improving the functional activity of subjects with SD.

Validity Study of Dynamic Balance Abilities Measure using a Smartphone (스마트폰을 이용한 동적균형능력 측정의 타당도 연구)

  • Han, Seul-Ki;Lee, Sang-Yong;Lee, Dae-Hee;Park, Jung-Seo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.77-82
    • /
    • 2016
  • PURPOSE: The purpose of this study was to investigate the validity of dynamic balance measurements using a smartphone. METHODS: Thirty subjects were selected out of Y-university students without fractures, operation history, and inflammatory arthritis who had not started regular exercise during the past three months. Their dynamic balance ability was measured by the Biodex Balance System (Biodex Medical Systems, Inc., USA) using smartphones. The smartphone utilized in this study was the Galaxy Note4 LTE (SM-N910K, Samsung, Korea), and the application was the Sensor Kinetics pro (Ver.2.1.2, INNOVENTIONS Inc, US). The dynamic balance ability was measured in triplicate. RESULTS: With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the roll value of the smartphone gyroscope versus the medial/lateral score of the Biodex Balance System. With eyes closed, a low level of correlation (r>0.30, p<0.05) and low reliability (ICC>0.60) were determined between the total value of the smartphone gyroscope versus the total score of the Biodex Balance System. CONCLUSION: This study indicated that using a smartphone can generate highly limited data regarding balance ability. They are unlikely to replace the existing more expensive devices entirely. However, smartphones may be highly useful in environments in which an expensive device is not available or when dynamic balance ability should be measured immediately or within a few hours.

Comparison of Daily Soil Water Contents Obtained by Energy Balance-Water Budget Approach and TDR

  • Rim, Chang-Soo
    • Korean Journal of Hydrosciences
    • /
    • v.8
    • /
    • pp.57-68
    • /
    • 1997
  • The daily soil water contents were obtained from the time domain reflectometry(TDR) method and energy balance-water budget approach with eddy correlation at the two small semiarid watersheds of Lucky Hills and Kendall during the summer rainy period. There was a comaprison of daily soil water content measured and estimated from these two different approaches. The comparison is valuable to evaluate the accuracy of current soil water content measuring system using TDR and energy balance-water budget approach using eddy correlation method at a small watershed scale. The degree of simiarity between the regressions of these two methods of measuring soil water content was explained by determining the correlations between these methods. Simple linear regression analyses showed that soil water content measured from TDR method was responsible for 58% and 63% of the variations estimated from energy balance-water budget approach with edy correlation at Lucky Hills and Kendall, respectively. The scatter plots and the regression analyses revealed that two different approaches for soil water content measurement at a small watershed scale have no significant difference.

  • PDF

Reliability and Concurrent Validity of the Balance Evaluation using Space Balance 3D and Tinetti Mobility Test in Subacute Stroke Patients (아급성 뇌졸중 환자에서 Space Balance 3D와 Tinetti Mobility Test를 이용한 균형 능력 평가의 신뢰도 및 동시타당도 연구)

  • Choi, Ji-Min;Lee, Jong-Hoon;Ha, Hyun-Geun;Kim, Yang-Gu;Kim, Yun-Hee;Bae, Young-Hyeon
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.8
    • /
    • pp.264-273
    • /
    • 2012
  • The purpose of this study was to determine the test-retest reliability and the concurrent validity between tinetti mobility test (TMT), berg balance scale (BBS) and space balance 3D which is one of the computerized measurement and visual feedback balance assessment system in subacute stroke patients. Twenty three ambulatory acute stroke subjects were measured the TMT, BBS and space balance 3D. The test-retest reliability(intra-class correlation coefficient: ICC) indicated that the static and dynamic balance in space balance 3D considered moderate reliability and TMT, BBS were good reliability. In case of concurrent validity, there were moderate validity (p<.01) between static balance test with space balance 3D and each TMT, BBS. But there were only poor validity (p<.05) between center to forward-left, center to backward-left phase in dynamic balance test with space balance 3D and each TMT, BBS. These findings suggest that in subacute stroke patients the test-retest reliability and concurrent validity using the space balance 3D and TMT were valuable in balance test but there was limitation to evaluate dynamic balance test.

The Effect of Functional Training Using a Sliding Rehabilitation Machine on the Mobility of the Ankle Joint and Balance in Children with CP

  • Park, Joo-Wan;Kim, Won-Bok
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.3
    • /
    • pp.293-299
    • /
    • 2014
  • PURPOSE: The purpose of this study was to investigate the effect of functional training using a sliding rehabilitation machine (SRM) on the mobility of the ankle joint and balance in children with cerebral palsy (CP). METHODS: The subjects consisted of 11 children who were diagnosed with spastic CP. They carried out the functional training using the SRM for 30 minutes, three times a week, for 8 weeks. Before and after all of the training sessions, the subjects were tested using the Pediatric Balance Scale (PBS) and Gross Motor Function Measurement (GMFM), range of motion (ROM) in the ankle joint, the pennation angle of the gastrocnemius muscle and the fascicle length of gastrocnemius muscle were measured to determine the mobility of the ankle joint and balance ability. RESULTS: There were significant differences between the pre-test and post-test in the PBS and GMFM. The ROM of the ankle joint was significantly increased after the functional training using the SRM. Moreover, the fascicle length was increased and the pennation angle was decreased after the functional training using the SRM, but the difference was not significant. CONCLUSION: These results suggest that functional training using the SRM may have some effect on the mobility of ankle joint and balance in children with CP. According to the results, this study could present an approach to the rehabilitation or treatment of children with CP.

Optimizing Study-life Balance within Higher Education: A Comprehensive Literature Review

  • HATCHER, Ryan;HWANG, Yosung
    • The Journal of Economics, Marketing and Management
    • /
    • v.8 no.2
    • /
    • pp.1-12
    • /
    • 2020
  • Purpose: The rise of the phrase Work Life Balance was bought up in 1986 when amid many Americans there was prevalence of detrimental work place practices like neglecting families, leisure activities and friends in order to achieve their study place goals. The significance of work-life balance has been gaining ground in recent years to grasp a wider range of groups, including students. Searching and finding a balance can be complex and challenging for many individuals and students. Research design, data and methodology: Through this paper we will explore how students balance the competing demands of work, study, and social activities. Several factors have increased imbalances within Educational organizations, and technology specifically has been influential. However, technology also provides a novel solution to this organizational performance management issue. A Study-Life Optimization model (SLO) is suggested, which incorporates information systems, analytics, and decision support into a Smart Service System. A general framework for this model, detailing data collection, measurement, and ethical issues is explained briefly. Results: Outcomes include improved WLB, greater perceived quality of life, and increased Educational organizational performance. Conclusions: This paper contributes to the relevant literature as it pays attention to the various students' of varying lifestyles school-work-personal lives. Findings of this study will provide a meaningful of the Work/school-life balance issues faced by students. The research could be helpful to the various stakeholders of a University, the curriculum designers, program coordinators etc.

Comparisons of Measurement Methods of the Moisture Content of Dried Vegetables (건조채소(乾燥菜蔬)의 수분측정방법(水分測定方法) 비교(比較))

  • Kwon, C.S.;Lee, D.S.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.1
    • /
    • pp.39-44
    • /
    • 1987
  • Measurement methods of moisture content were compared with 7 dried vegetables (red pepper, onion, green onion, garlic, ginger, carrot and radish). The moisture contents of dried vegetables having different moisture contents were determined by atmospheric oven drying, infrared balance, vacuum oven and Karl Fisher methods. Vacuum oven and Karl Fisher methods gave the relatively agreed results and considered to give the accurate moisture content. Atmospheric oven drying and infrared balance methods resulted in higher moisture content than methods mentioned above, because of the thermal decomposition of solid. Calibration of the moisture data of atmospheric oven drying method into the vacuum oven data was undertaken. The thermodecomposable solid fraction was high in onion, radish, green onion and carrot, and was in the range of 8.0-11.7% of the total solid in these products.

  • PDF