• Title/Summary/Keyword: Baffle tube

Search Result 62, Processing Time 0.028 seconds

A Case Study on the vibration and noise by acoustic resonance in the tube bank of a boiler of 75MW power plant (75MW 급 발전용 보일러 관군에서의 음향공진에 의한 진동/소음 사례연구)

  • Kim, Cheol-Hong;Bang, Kyung-Bo;Ju, Young-Ho;Byun, Hyung-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.150-155
    • /
    • 2000
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a power plant. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At the resonance, the value of vibration in this system was 595 ${\mu}m$, p-p and the sound pressure level was maximum 103 dBA. And the resonance frequency was found to be 35 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance is possible. In this system, the difference of these frequencies was 1.8%. We can evaluate the possibility of acoustic resonance by using damping parameter. We did eliminate acoustic resonance by installing baffle in tube bank. After installing baffle, the level of vibration and noise was reduced dramatically.

  • PDF

Numerical analysis for heat transfer and pressure drop characteristics of (다양한 배플 인자에 따른 셀-튜브 열교환기의 열전달 및 압력강하 특성에 관한 수치해석)

  • Hou, Rong-Rong;Park, Hyeong-Seon;Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.367-375
    • /
    • 2014
  • In numbers of kinds of heat exchanger, the shell-tube heat exchanger is the most commonly used type of heat exchanger in the industry field. In order to improve the thermal performance of the heat exchanger, this study was analyzed heat transfer characteristics according to arrangement of baffle and direction of baffle and bump phase of baffle about shell-tube heat exchanger using appropriate SST (Shear Stress Transport) turbulence model for flow separation and boundary layer analysis. As the boundary condition for CFD (Computational Fluid Dynamics) analysis, the inlet temperature of shell side was constantly 344 K and the variation of the water flow rate was 6, 12, 18 and 24 l/min. As the result of analysis, zigzag baffle arrangement enhances heat transfer rate and pressure drop. Furthermore, in the direction of the baffle, heat transfer rate is more improved with vertical type and angle $45^{\circ}$ type than existing type, and pressure drop was little difference. Also, the bump shape of baffle surface contributes to heat transfer rate and pressure drop improvement due to the increased heat transfer area. Through analysis results, we knew that the increase of the heat transfer was influenced by flow separation, fluid residual time, contact area with the tube, flow rate, swirl and so on.

Enhancement of Performance of Shell and Tube Heat Exchanger Using Pertinent Leakage Flow Between Baffle and Tube Bundles (배플과 관군간의 적정 누설유동을 이용한 쉘-관 열교환기의 성능향상)

  • Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.223-229
    • /
    • 2015
  • In this study, the effects of the leakage flow between the baffle and tube bundles on the performance of a shell and tube heat exchanger (STHE) were examined using the commercial software ANSYS FLUENT v.14. A computational fluid dynamics model was developed for a small STHE with five different cases for the ratio of the leakage cross-sectional area to the baffle cross-sectional area, ranging from 0 to 40%, in order to determine the optimum leakage flow corresponding to the maximum outlet temperature. Using fixed tube wall and inlet temperatures for the shell side of the STHE, the flow and temperature fields were calculated by increasing the Reynolds number from 4952 to 14858. The present results showed that the outlet temperature, pressure drop, and heat transfer coefficient were strongly affected by the leakage flow, as well as the Reynolds number. In contrast with a previous researcher's finding that the leakage flow led to simultaneous decreases in the pressure drop and heat transfer rate, the present study found that the pertinent leakage flow provided momentum in the recirculation zone near the baffle plate and thus led to the maximum outlet temperature, a small pressure drop, and the highest heat transfer rate. The optimum leakage flow was shown in the case with a ratio of 20% among the five different cases.

A Study on the Acoustic Baffle to Reduce Ghost Target According to Structure behind Cylindrical Array Sensor (원통형 배열센서 후면 구조물에 의해 발생하는 허위 표적 감소를 위한 음향 배플 연구)

  • Seo, Young Soo;Kim, Dong Hyun;Kim, Jin Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.440-446
    • /
    • 2015
  • Acoustic signal is emitted from a vessel and received by a cylindrical array sensor at some distance from the vessel. Acoustic signal is the source for a cylindrical array sensor which is designed to detect the acoustic signal. Cylindrical array sensors seldom have an ideal hydrodynamic shape and are not sufficiently robust to survive without some protection and they are normally housed in a sonar dome. Reflected signals by some structure inside a sonar dome make unwanted signals. Therefore, an acoustic baffle is used to minimize unwanted signals. The performance of the acoustic baffles can be determined from the acoustic numerical analysis at the design stage. In this study, finite element method was used to analyze the acoustic field around the cylindrical array sensor and baffle effects. The baffle performance can be defined the echo reduction. To show the baffle performance, the specimens were made for pulse tube test and echo reductions were measured during the test. In this paper, the effect of echo reduction of the acoustic baffle was discussed.

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • v.62 no.2
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

The Effect of Duct Inlet Condition on Flow Characteristics of Fan (덕트의 입구조건이 팬의 특성에 미치는 영향)

  • Kim, J.S.;Cho, K.R.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.217-224
    • /
    • 1995
  • The effects of duct inlet conditions on fan characteristics and upper wind velocity fields were investigated for two kinds of impellers. As the duct inlet condition, the relative positions between duct inlet and fan impeller and the size of baffle plate mounted on a duct inlet were selected. The 3-dimensional velocity components in flow fields were measured by a 5-holes pitot tube. From the results of measurements, it was found that the size of baffle plate scarecely effect on upper wind flow fields and characteristics of fan. It was also confirmed that the upper wind velocity distributions can be estimated by the potential flow field with large baffle plate at duct inlet.

  • PDF

A study on heat transfer characteristics and pressure drop of heat transfer by baffle cut rate (배플 플레이트를 갖는 열교환기의 열전달 및 압력강하에 관한 연구)

  • Bae, Sung-Woo;Choi, Soon-Ho;Yoon, Seok-Hoon;Oh, Cheol
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.172-177
    • /
    • 2005
  • The object of this experiment is comparing heat transfer performance and pressure drop characteristics by baffle cut rate, fluid velocity and heating temperature. Experiments were carried out in cross flow heat exchanger with water as a working fluid. In this experiment, baffle cut rate is 30%, 40%, 50%, velocity is 0.5m/s, 1.0m/s, 1.5m/s, and heating temperature is $30^{\circ}C$, $40^{\circ}C$, $50^{\circ}C$. An experimental device to measure the heat transfer coefficient was constructed. The experimental result were obtained for the fully developed turbulent flow of water in tube on the condition of uniform heat flux.

  • PDF

Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor (연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측)

  • Park J. H.;Chae H. T.;Park C.;Kim H. I.
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

Change of Piping-System Dynamics with Installation of Pogo Suppression Device (포고억제장치 설치에 따른 배관계 동특성 변화)

  • Lee Jun Kyoung;Lee Sang Yong;Lee Han Ju;Oh Seung Hyub
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.2
    • /
    • pp.32-39
    • /
    • 2005
  • The effectiveness of the pogo suppression device (PSD) on the response of the piping system simulating the fuel (or oxidizer) supply lines of the rocket engines was investigated. The system response defined as the ratio of the flow rate to the pressure in the main tube was obtained for various PSD gas volumes $((0\~2)\times10^{-3}m^3)$ and three different baffle hole diameters (5, 50, 115mm). Existence of a gas volume in the PSD reduced the system resonance frequency. With a larger gas volume, the resonance frequency became lower, but only slightly, while the fluctuations of the main tube pressure and the flow rate damped down considerably. The resonance frequency decreased with the increase of the PSD inlet restriction (or the decrease of the baffle hole diameter), though slightly. However, with a larger inlet restriction, the PSD pressure wave showed a delayed response with the smaller amplitude compared to the pressure variation in the main tube.

Experimental study on reduction of impulsive noise generating at exit of high-speed railway tunnel (고속철도 터널출구에서 발생하는 충격성 소음의 저감을 위한 실험적 연구)

  • Kim, Hui-Dong;Setoguchi, Toshiaki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2375-2385
    • /
    • 1996
  • As a compression wave is emitted from a duct, an impulsive wave generates and causes an impulsive noise that is at present a serious environmental noise pollution. In order to clarify the acoustic characteristics of the noise and to reduce their pressure levels, a series of model experiments were conducted on the impulsive waves emitted from an open end of a shock tube. The impulsive waves with various intensities were obtained by controlling the operation pressure ratio of the shock tube. Various kinds of silencers such as the exit boxes with baffle plates, were applied to the duct exit to reduce the impulsive noises. The effects of geometry of silencers and shock Mach number on the noise reduction were clarified. From the measurements of sound pressure level, it was found that installing the baffle plate into the exit box is effective in lowering the noise level at far fields, and that the recommendable geometries of silencer are L/D=1, H/D=1 and H/D=0.75.