• Title/Summary/Keyword: Baffle Installation

Search Result 26, Processing Time 0.023 seconds

Investigation on the Hydrodynamic Behaviors of the Clarifier with an Interior Baffle in WWTP by using of Radiotracer $^{99m}Tc$ ($^{99m}Tc$ 추적자를 이용한 하수처리 시설 내 침전조의 정류벽 설치 유무에 따른 유체거동 변화측정)

  • Kim, Jin-Seop;Kim, Jong-Bum;Kim, Jae-Ho;Jung, Sung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.3
    • /
    • pp.117-122
    • /
    • 2007
  • The hydrodynamic behaviors of the clarifier with an interior baffle in a wastewater treatment plant was investigated by using a radiotracer $^{99m}Tc$(30 40 mCi) to verify the results of CFD(computational fluid dynamics) modelling in the previous study. The clarifier model was manufactured with consideration to the hydraulic similarity(1/21) of a real plant($L{\times}W{\times}H:2.6{\times}0.4{\times}0.2m$). By installation of an interior baffle to the clarifier, the strong density current at the bottom of the clarifier decreased substantially and increased the area of sludge settling zone, which were visualized successfully from the radiotracer experiment. Also the portion of short circuit stream changed from 48 % to 32 % and the mean residence time of sludge decreased from 940 sec to 810 sec, which corresponds to the results of CFD modelling. As a result, it is anticipated that radiotracer technology can be used as an important tool for designing new wastewater treatment plants and verifying their performances after structural modifications.

A study on the reduction of noise and vibration by acoustic resonance in the tube bank of a circulating fluidized bed combustion boiler (순환 유동층 보일러 관군의 음향공진에 의한 이상소음 발생 및 저감 연구)

  • Park, Eung-Kyu;Song, Keun-Bok;Kim, Won-Hyun;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.101-106
    • /
    • 2011
  • In the present paper, the phenomena of abnormal noise and vibration due to acoustic resonance of CFBC(Circulating Fluidized Bed Combustion) boiler was presented. The acoustic resonance which occurred in the gas path of CFBC boiler system was caused by coincidence of vortex shedding frequency of tube bank and acoustic natural frequency of duct and hopper. And, the phenomena of beating arose from the interference of two closed resonant waves at 66.4Hz and 70.8Hz. There are two control methods for acoustic resonance in this system. The first method is to change the vortex shedding frequency from the structural alterations on the tube bank. And the second method is to change the acoustic natural frequency of the gas path with the installation of anti-noise baffles. The second one which is relatively easy to apply, was adapted in this study. As a result, the noise and vibration level have been decreased by 41dB and 94% at 66.4Hz, respectively. And the improvement of noise and vibration at 70.8Hz was identified by sensory evaluation.

  • PDF

Computer-Aided Optimal Design of Heat Exchangers (컴퓨터에 의한 열교환기 최적설계)

  • Song Tae Ho;Oh Jin Kook;Yoon Chang Hyun;Huh Gyoung Jae
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.10 no.4
    • /
    • pp.297-303
    • /
    • 1981
  • Optimal design of shell and tube heat exchanger system with the working fluids which may condense outside the tubes has been carried out under specified inlet and outlet conditions. Independent variables such as number of parallel series, tube diameter, distribution pitch, tube side pressure loss, baffle cut and shell side pressure loss as well as dependent variables such as shell diameter, number of tubes, number of serial series and number of baffles were all characterized according to the standard. Exhaustive search method was used to construct a computer program together with the calculation of heat transfer rate by LMTD method. stress analysis of maj or parts was made to examine their dimensions satisfying heat transfer and pressure loss requirements. Cost estimation based on the installation, operation and maintenance was also made, A few representative variables, heat transfer area, shell diameter and pressure loss, were used to express cost function, finally giving the optimal selection of all tentative solutions.

  • PDF

The Experimental Study for Variance of Sediment Volume Concentration of Debris Flow due to Damped Structures (감쇠 구조물에 의한 토석류 토사체적 농도 변화에 관한 실험적 연구)

  • Youngdo Choi;Sungduk Kim;Hojin Lee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.1-7
    • /
    • 2023
  • The purpose of this study is an experimental research to investigate the effectiveness of debris flow reduction structures when a debris flow disaster occurs on a steep slope. The control structure for debris flow took the form of baffle, and the soil deposition area and soil runout distance due to debris flow from the downstream were investigated according to the installation number of baffle and each specification. As the slope of the channel became steeper, the sediment deposition area and runout distance increased, and as the sediment volume concentration decreased, the sediment deposition area and runout distance increased. When the sediment concentration was low, differences appeared depending on the slope of the channel because the debris flow had a high liquid content. Overall, the larger the sediment volume concentration, the greater the decrease in sediment deposition area and soil runout distance. As the number of baffles increases, the soil deposition area and runout decrease, showing that the baffles have the ability to control debris flows. The results of this research will provide good information when installing attenuation or control structures when sediment disasters occur in steep slopes.

Numerical Study for Flow Uniformity in Selective Catalytic Reduction(SCR) Process (SCR 공정에서 반응기 내부의 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Kim, Min-Choul;Lee, Jae-Jeong;Lee, Gang-Woo;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4666-4672
    • /
    • 2011
  • Performance of NOx removal in SCR(Selective Catalytic Reduction) process depends on such various factors as catalyst factors (catalyst composition, catalyst form, space velocity, etc.), temperature of exhaust gas, and velocity distribution of exhaust gas. Especially the flow uniformity of gas stream flowing into the catalyst layer is believed to be the most important factor to influence the performance. In this research, the flow characteristics of a SCR process at design stage was simulated, using 3-dimensional numerical analysis method, to confirm the uniformity of the gas stream. In addition, the effects of guide vanes, baffles, and perforated plates on the flow uniformity for the inside and catalyst layer of the reactor were studied in order to optimize the flow uniformity inside the SCR reactor. It was found that the installation of a guide vane at the inlet duct L-tube part and the installation of a baffle at the upper part is very effective in avoiding chaneling inside the reactor. It was also found that additional installation of a perforated plate at the lower part of the potential catalyst layer buffers once more the flow for very uniform distribution of the gas stream.

Numerical Study on the Internal Flow in the Cyclone Vacuum Cleaner (사이클론 청소기 내부 유동에 관한 수치해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.283-289
    • /
    • 2014
  • General household vacuum cleaners consist of dust collector, pre filter, motor and exhaust filter, and the filtered clean air is discharged to the atmosphere. By using the CFD methods, we estimated the internal flow in two types of commercial cyclone vacuum cleaners to evaluate the dust collection performance. From the analysis, it was known that the number of revolution had higher values in cyclone cone region. CFD analysis in a specific showed non-uniform velocity distribution at outlet, which results in the deterioration of particle collection performance. In order to improve flow condition, the installation of baffle was proposed and the values of velocity RMS were estimated.