• Title/Summary/Keyword: Badge

Search Result 109, Processing Time 0.024 seconds

The Light Sensitivity and Angular Dependence of the $Mg_2SiO_4$:Tb(MSO-S) TLD ($Mg_2SiO_4$:Tb(MSO-S) TLD의 광감수성과 방향의존성)

  • Kim, Do-Sung;Park, Myeong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.1
    • /
    • pp.59-63
    • /
    • 1998
  • The light sensitivity and angular dependence of the $Mg_2SiO_4$:Tb(MSO-5) TLD which affect the accuracy of the radiation dose measurement are investigated. Light-induced thermoluminescence of MSO-S TLD under the 200 lux fluorescent and the incandescent lamp for 8 hours are corresponding to 11 and 3 mR exposure, respectively. TL intensity ratio of the incident angle of ${\pm}80^{\circ}$ to normal incidence for MSO-S and badge type MSO-L are about 0.8 and 0.15, respectively.

  • PDF

Analysis and Conservation of Metal Thread Made of Proteinaceous Substrate - Golden Decorative Rank Badge of an Official Uniform Excavated from Baekryeong Im's Tomb in the 16th Century of Korea - (단백질계 배지로 이루어진 금속사의 분석과 보존처리 - 16세기 임백령 묘 출토 단령의 직금 흉배를 중심으로 -)

  • Noh, Soo-Jung;Oh, Joon-Suk
    • Journal of the Korean Society of Costume
    • /
    • v.58 no.9
    • /
    • pp.129-141
    • /
    • 2008
  • Jikgeum(woven with supplementary golden wefts) hyungbae(rank badge) of danryung(official uniform) excavated from Im Backryung'tomb($1498{\sim}1546$) of the Joseon dynasty($1392{\sim}1910$) at Goyang, Gyunggi-Do in 2007, was in a critical condition because of serious collapse of substrate in metal thread. For conservation of hyungbae, metal thread was examined by different scientific methods(Light Microscope, Scanning Electron Microscope and Energy Dispersive X-Rray Spectrometry(SEM-EDS), Fourier Transform Infrared Spectroscopy(FT-IR)). Analytical data showed that metal thread was gilt membrane strip composed of gold leaves and proteinaceous substrate which was probably parchment. To protect collapse of substrate, 1% solution of Paraloid B-72 was infilterated into substrate for consolidation of substrate and it was adhered to warp of fabric in hyungbae, before wet cleaning. After wet cleaning, the most of the gold leaves were restored, which was confirmed by both the examination with the naked eye and the microscopic examination.

Design of Badge Service Platform Based on Blockchain (블록체인 기반 배지서비스 플랫폼 설계)

  • Kim, Min-Young;Yoo, In-Seak;Lim, Keol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.11
    • /
    • pp.332-338
    • /
    • 2020
  • The blockchain contains potential to contribute for the development of education, teaching and learning as it provides the basic technologies which can handle the data transparently and stably in reliability. Especially, blockchain technology can guarantee the transparency, stability and reliability on the data especially in managing longitudinal education data. This study designed the Badgechain service platform combining badges and blockchains. This service consists of Badgechain solution, Moodle LMS linked to Badgechain added with Badgechain service as a learning activity, and Badgechain Wallet site where badges issued by various agencies can be viewed and managed. This study was performed as a basic study on educational use of blockchain.

An Integrated Air Monitoring Approach for Assessment of Formaldehyde in the Workplace

  • Dugheri, Stefano;Bonari, Alessandro;Pompilio, Ilenia;Colpo, Marco;Mucci, Nicola;Arcangeli, Giulio
    • Safety and Health at Work
    • /
    • v.9 no.4
    • /
    • pp.479-485
    • /
    • 2018
  • The aim of this study is to validate an integrated air monitoring approach for assessing airborne formaldehyde (FA) in the workplace. An active sampling by silica gel impregnated with 2,4-dinitrophenylhydrazine, a passive solid phase microextraction technique using O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine as on-fiber derivatization reagent, an electrochemical direct-reading monitor, and an enzyme-based badge were evaluated and tested over a range of 0.020-5.12 ppm, using dynamically generated FA air concentrations. Simple linear regression analysis showed the four methods were suitable for evaluating airborne FA. Personal and area samplings in 12 anatomy pathology departments showed that the international occupational exposure limits in the GESTIS database were frequently exceeded. This monitoring approach would allow a fast, easy-to-use, and economical evaluation of both current work practices and eventual changes made to reduce FA vapor concentrations.

Impacts of Badges and Leaderboards on Academic Performance: A Meta-Analysis

  • KIM, Areum;LEE, Soo-Young
    • Educational Technology International
    • /
    • v.23 no.2
    • /
    • pp.207-237
    • /
    • 2022
  • As technological changes continue to accelerate every day, meeting the needs of a shifting educational landscape requires leaving an exclusively "in-person" education behind. Gamified learning environments should be carefully designed in light of conflicting studies to suit students' needs. The purpose of this meta-analysis is to draw conclusive results regarding the application of the most commonly used game elements in education, i.e., badges and leaderboards, through a comprehensive analysis of their impact on academic performance in online learning. Review Manager (RevMan 5.4) was used to analyze eligible studies selected from Emerald, SAGE, ERIC, EBSCO, and ProQuest between January 2011 and January 2022. Analyzing 37 studies found that using leaderboards and badges in online education enhanced academic performance when compared to traditional learning without gamification (SMD = 0.39). The badge-only intervention showed a larger effect size (SMD = 0.33) than the leaderboard-only intervention (SMD = 0.27). Badges and leaderboards together exhibited a larger effect size (SMD = 0.48) than individual game elements (SMD = 0.40). The impact of the game elements on academic performance was greater in the humanities (SMD = 0.51) than in STEM fields (SMD = 0.32) and was greater for K-12 students (SMD = 0.63) than for college students (SMD = 0.31). This study contributes to a timely discussion of the use of badges and leaderboards in COVID-19 online learning trends and provides relevant data for designing integrations of online education and gamification models.

Research on the Design and Use of Digital Badges to Increase Educational Value (교육적 가치를 높이는 디지털배지 설계와 활용 연구)

  • Youn A Min;Ji-Eun Lee
    • Journal of Information Technology Services
    • /
    • v.22 no.6
    • /
    • pp.71-86
    • /
    • 2023
  • The rapid change in industry and the technological gap give rise to social demand for upskilling and reskilling and spread of alternative education. Against this backdrop, digital certification and career management tools can be used to manage various types of learning activities comprehensively. Digital badges provide various kinds of history information related to individual learning, and the reliability and transparency of the issued information can be strengthened by applying blockchain technology. There have been various discussions about digital badges for a long time, but due to the lack of standards to support the issuance and distribution of digital badges, they have been partially used in some areas. However, interest in digital badges is increasing due to the development of related technologies, establishment of standards, paradigm changes in higher education, and government policies related to nurturing digital talent. This paper deals with the use of digital badges for efficient and transparent learning management and career management in an online learning environment. The researcher analyzes the technical characteristics and use cases of digital badges, and proposes a plan for use in online higher education based on them.

The Development of Exposure Assessment Tools for Risk Assessment of Volatile Organic Compounds (VOCs의 위해성 평가를 위한 노출분석 방법 연구)

  • Jo, Seong-Joon;Shin, Dong-Chun;Chung, Yong;Lee, Duck-Hee;Breysse, Patrick N.
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • Volatile organic compounds (VOCs) are an important public health issue in Korea and many important questions remain to be addressed with respect to assessing exposure to these compounds. Because they are ubiquitous and highly volatile, special techniques must be applied in their analytic determination Valid Personal exposure assessment methods are needed to evaluate exposure frequency, duration and intensity, as well as their relationship to personal exposure characteristics. Biological monitoring is also important since it may contribute significantly in risk assessment by allowing the estimation of effective absorbed doses. This study was on ducted to establish the environmental measurement, personal dosimetry and biological monitoring methods for VOCs. These methods are needed to compare blood, urinary and exhalation breath VOC levels and to provide tools for risk assessment of VOC exposure. Passive monitors (badge type) and a active samplers (trap) for the VOCs collection were used for air sampling. Methods development included determining the minimum detectable amounts of VOCs in each media, as well as evaluating collection methods and developing analytical procedures. Method reliability was assessed by determining breakthrough volumes and comparing results between laboratories and with other methods. A total capacity of trap used in this study was 60ι. Although variable by compound, the average breakthrough was 20%. Also, there was no loss of compounds in trap even if keep for 45 day in -7$0^{\circ}C$. The recovery of active and passive methods was 69% ~ 126% and method detection limit was 0.24 $\mu\textrm{g}$/trap and 0.07 $\mu\textrm{g}$/badge. There was no statistical difference (P > 0.05) between active and passive methods.

Reconstruction of Radiation Dose Received by Diagnostic Radiologic Technologists in Korea

  • Choi, Yeongchull;Kim, Jaeyoung;Lee, Jung Jeung;Jun, Jae Kwan;Lee, Won Jin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.49 no.5
    • /
    • pp.288-300
    • /
    • 2016
  • Objectives: Diagnostic medical radiation workers in Korea have been officially monitored for their occupational radiation doses since 1996. The purpose of this study was to design models for reconstructing unknown individual radiation doses to which diagnostic radiation technologists were exposed before 1996. Methods: Radiation dose reconstruction models were developed by using cross-sectional survey data and the personal badge doses of 8167 radiologic technologists. The models included calendar year and age as predictors, and the participants were grouped into six categories according to their sex and facility type. The annual doses between 1971 and 1995 for those who were employed before 1996 were estimated using these models. Results: The calendar year and age were inversely related to the estimated radiation doses in the models of all six groups. The annual median estimated doses decreased from 9.45 mSv in 1971 to 1.26 mSv in 1995, and the associated dose variation also decreased with time. The estimated median badge doses from 1996 (1.22 mSv) to 2011 (0.30 mSv) were similar to the measured doses (1.68 mSv to 0.21 mSv) for the same years. Similar results were observed for all six groups. Conclusions: The reconstruction models developed in this study may be useful for estimating historical occupational radiation doses received by medical radiologic technologists in Korea.

Development and Evaluation of a Badge-type Passive Sampler for the Measurement of Short-term Nitrogen Dioxide in Ambient Air (대기 중 이산화질소의 단기 측정을 위한 뱃지형 passive sampler의 개발 및 평가)

  • Kim Sun Kyu;Yim Bong Been;Jung Eui Suk;Kim Sun Tae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.117-126
    • /
    • 2006
  • The purpose of this study is to develop a badge-type passive sampler for the measurement of short-term nitrogen dioxide and to evaluate its performance. The principle of the method is a colorimetric reaction of nitrogen dioxide with sulfanilic acid, N-1-naphthylethylendiamine, and phosphoric acid. First, it has been shown that the filter paper should be rinsed with ultrapure water and ultrasound, and then dried in a vacuumed desiccator. The concentration and volume of absorption reagent (triethanolamine) were $20\%$ and 100 ${\mu}L$, respectively. The extraction time was determined as 60 min. Second, duplicate measurements (n= 116) were carried out for evaluating the precision of the passive sampler. The relative error and the correlation coefficient between duplicates are $3.4\pm 3.0\%$ and 0.994, respectively. In addition, the $95\%$ confidence interval of intraclass correlation coefficient and the estimated value are 0.992$\sim$0.996 and 0.994, respectively. Third, a paired t-test was carried out for evaluating the accuracy of the passive sampler (n=40). In the result of the test, the $95\%$ confidence interval of the difference was -1.710 ppb <$\gamma$< 0.788 ppb. Finally, the average concentration of blanks, measurement detection limit, limit of detection, and limit of quantification are $2.4\pm 0.4$ ppb, 104 ppb, 3.8 ppb, and 7.0 ppb, respectively.

A Method for Simultaneous Measurement of Air Kerma, Half Value Layer and Tube Potential in Quality Control Procedure of Diagnostic x ray units

  • Katoh, Tsuguhisa;Saitoh, Hidetoshi;Ohtani, Hiroki;Negishi, Tooru;Myojoyama, Atsushi;Ohno, Yuusuke;Sasaki, Takehito
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.294-297
    • /
    • 2002
  • For the quality control procedure of diagnostic x ray units, a method for simultaneous measurement of air kerma, half value layer and tube potential was developed utilizing a computed radiography system for intraoral radiography and film badge case. The response of average pixel values under the windows were calibrated by x rays generated at tube potentials from 40 to 140 kV with filtration from 1.5 to 3.7 mmAl. The calibration curves for half value layer and tube potential were derived as functions of attenuation factors by the 1.4 mmAl filter and the 0.2 mmCu filter. The energy dependency of the open window response was corrected by the calibration factor as a function of the attenuation factor by the 1.4 mmAl filter. The uncertainty of the estimated half value layer, tube potential and air kerma were 0.2 mmAl, 3.6 % and 5 %, respectively. It was thus suggested that this system could be applied to quality control program to detect the variation of working condition of x ray units in clinical use.

  • PDF