Purpose: The purpose of this study was to determine the effects of a chair backrest on respiratory function after prolonged sitting. Methods: Twenty-four young healthy subjects (12 males and 12 females) volunteered to participate in this study, and were equally allocated to a backrest (n=12) or a without backrest group (n=12). A spirometer was used to measure the respiratory functions of all subjects. Results: The chair with backrest group were significant difference in forced vital capacity (FVC), Forced expiratory volume in 1 second (FEV1), and peak expiratory flow (PEF) after sitting for 1 hour, compared with chair without backrest group (p<0.05). The chair with backrest group showed a significantly decreased in FVC, FEV1, and PEF. Conclusion: Using a chair without a backrest may help to reduce lung function deterioration as compared with a chair with a backrest.
Purpose: This study was done to investigate the effects of backrest elevation of 0 degree and 30 degrees that minimize the risk of increasing ICP when CVP is measured. Methods: Subjects were sixty-four patients who stayed in the neurosurgical intensive care unit after brain surgery at two university-based hospitals. CVP, blood pressure, heart rate and ICP were measured along with position changes in order of backrest position with primary 30 degrees backrest position, 0 degree backrest position and secondary 30 degrees backrest position. For data analysis, one-group, repeated-measures analysis of variance design was used in SAS program. Results: Backrest elevations from 0 degree to 30 degrees did not alter the CVP without increasing the ICP. Therefore, 30 degrees backrest position is a preventive position without increasing ICP. Conclusion: 30 degrees backrest position might be appropriate for brain injury patients when CVP is measured.
Objective: This study identifies the difference among the heights of a chair's backrest (High, Mid, No), the biomechanical changes chair users undergo over time, and the variables that can measure musculoskeletal disorders, eventually providing information on the appropriate type of backrest. Method: Eleven healthy subjects in their 20s and 30s who had no experience with musculoskeletal disorders or surgical operations within the last 6 months participated in this study. Computer typing tasks were randomly designated and performed according to the type of chair backrest, and evaluation was performed for Flexion-Relaxation Ratio (FRR) analysis after the computer typing tasks. This study used eight infrared cameras (sampling rate: 100 Hz) and nine-channel electromyography (sampling rate: 1,000 Hz). ANOVA with repeated measures was conducted to verify the results, with the statistical significance level being α = .05. Results: Although there was no significant difference in craniovertebral angle (CVA), this study showed time and interaction effects depending on the height of the backrest (p<.05). When working without the backrest, the head-spine angle was lower compared to the chairs with backrest, based on the computer work. As for the head angle, the higher the back of the chair was, the less the head flexion and the body angle became, whereas the body flexion became less when there was a backrest. In addition, the body flexion increased over time in all types of backrests (p<.05). The muscle activity of the upper body tended to be high in the high backrest chair. On the other hand, a lower muscle activity was found with a low backrest. Conclusion: These results show that a chair is more ergonomic when the body angle is correctly set without bending and when it is supported by a low backrest. Accordingly, this study determines that the backrest affects shoulder and neck musculoskeletal disorders during typing and that medium-height backrest chairs can help prevent musculoskeletal disorders, contrary to the expectation that high-backrest chairs are preferable.
This study was purposed to provide basic information on the correct application of a wheelchair's backrest angle by investigating the change in cardiopulmonary function according to backrest angle during propulsion. This study examined the effects of the wheelchair's backrest angle on the cardiopulmonary function by varying the angle to $0^{\circ}$, $10^{\circ}$ and $20^{\circ}$ with a propulsion velocity of 60 m/min. The experimental parameters were respiration rate, oxygen consumption rate and oxygen consumption rate/kg which were measured by a portable wireless oxygen consumption meter (COSMED, $K4b^2$). The results of the study were as follows: 1) There were no statistically significant differences in respiration rates due to changes in the wheelchair backrest angle (p>.05). 2) There were statistically significant differences in oxygen consumption rates due to changes in the wheelchair backrest angle (p<.05). 3) There were also statistically significant differences in the oxygen consumption rate/kg due to changes in the wheelchair backrest angle (p<.05). In conclusion, changes in the backrest angle of wheelchairs during propulsion influences oxygen consumption rates and heart rates, while respiration rates are not affected. Therefore, a training program for good seating and posture needs to be provided, and the wheelchair seating system should be equipped with the unadjustable-angle wheelchair to reduce the functional load on the cardiopulmonary system.
Kim, Min-Hee;Yoo, Won-Gyu;Yi, Chung-Hwi;Kim, Han-Sung;Kim, Su-Jin
Physical Therapy Korea
/
v.15
no.4
/
pp.59-63
/
2008
Pressure sores are painful and needless complications of critical illness. and manifest as a localized area of ischemic necrosis of tissue caused by pressure. This study analyzed the bed-backrest elevation system combined with hip and knee flexion for lower extremity lower pressure reduction. Eight healthy adults aged 21 to 26 years were recruited. The Body Pressure Measurement Mat of the TekScan system was used to measure the location and magnitude of the peak pressures on the body bed interface. The SPSS statistical package was used to analyze the significance of differences between the general bed-backrest elevation system and the bed-backrest elevation system combined with hip and knee flexion using the paired t-test. The result showed that the body-pressure of the lower extremity was more significantly reduced for the bed-backrest elevation system combined with hip and knee flexion ($26.6{\pm}4.3$ mmHg) than a general bed-backrest elevation system ($37.3{\pm}5.2$ mmHg) (p<.05).
The purpose of this study was to investigate effects of different chair type (with backrest chair and without backrest chair) and pelvic position (anterior pelvic tilting and posterior pelvic tilting) on three abdominal muscles (upper rectus abdominis, external oblique, internal oblique) and back extensor activation during lower extremity exercise. The four different conditions during bilateral knee extension exercise were: (1) leaning on backrest chair with anterior pelvic tilting, (2) leaning on backrest chair with posterior pelvic tilting, (3) anterior pelvic tilting without backrest chair, and (4) posterior pelvic tilting without backrest chair. Fifteen healthy male subjects with no history of neuromusculoskeletal disease voluntarily participated in this study. Electromyography (EMG) was used to collect muscle activation data, and muscle activation data was expressed as a percentage of maximal voluntary isometric contraction (%MVIC). One-way repeated analysis of variance (ANOVA) was used to determine the statistical significance, and Bonferroni comparison was used as a post hoc test. The results of this study were the following: (1) Erector spinae activation was significantly lower in posterior pelvic tilting without backrest compared with that in leaning on backrest chair with anterior pelvic tilting. (2) Upper rectus abdominis activation was significantly lower than erector spinae in all four different chair type and pelvic tilting conditions.
Objective: This study aims to develop and scientifically investigate the efficacy of the Spine S-curve Reactive Backrest that responds to the spine curvature of the user when seated, and maintains and enhances the natural S-curve of the lower back, thereby helping to relieve fatigue, correct posture and prevent spine deformities. Background: The focus of current development, design guidelines and/or standards for office chairs is mainly placed on the chair's dimensions, incline angle, adjusting features and lumbar support. Research and development was called for developing a chair backrest that maintains and improves the S-curve of the full spine. Method: The Spine S-curve Reactive Backrest was ergonomically designed to maintain correct posture and enhance user comfort. When leaned on, the backrest responds to the user's spine line and the whole lower back sits closely against the backrest, thereby aligning the user's lower back and backrest as one to maintain and improve the natural S-curve formation of the spine. In order to evaluate the efficacy of the newly designed chair (new design) and the comparison target (chair), five male college students of standard body type with normal spine curvature were selected as test subjects, and a motion analyzer and electromyography were utilized to measure S-curve and erector spinae muscle activity when seated. Results: The spine S-curve was better maintained and improved when sitting in the new design than in the comparison chair. Particularly notable was the greater displacement gap of the thoracic spine than the cervical spine, and also that of the lumbar more than the thoracic spine, with the increase of the backrest tilting angle. Furthermore, the electromyogram results showed the new design caused a lower fatigue level of the erector spinae muscles compared to the comparison chair, and also earned a higher preference in the subjective opinion results. Conclusion: The newly designed chair in this study responds to the user's spine curvature and maintains and enhances the lower back's natural S-curve, and thereby relieves fatigue, promotes better posture, and helps to prevent spine deformities better than existing office chairs. There is a need to widely introduce and supply this new design. Application: The new design is applicable to office and student chairs, and is expected to improve concentration and work efficiency.
Transactions of the Korean Society of Mechanical Engineers A
/
v.34
no.2
/
pp.167-174
/
2010
In this study, the optimal position for the backrest pivot of an office chair was investigated by evaluating its performance in terms of the lumbar support and sliding distance of the back from the backrest during tilting motions. The simulation was performed using a mathematical model, which included a human body and a chair. Forty-two backrest pivot points were selected on the sagittal plane around the hip joint of a sitting model. A motion analysis study was also performed using a prototype of an office chair (A-type) with a backrest pivot located on the hip joint of a normal Korean model and a typical office chair (B-type) with its pivot located under the seat. The simulation results showed that both the lordosis angle and the slide distance of the back were minimized when the backrest pivot was positioned close to the hip joint. The experimental results showed that the slide distance and gap between the sitter's lumbar and the backrest was smaller with the A-type than the B-type. Based on the simulation and experimental results, it can be concluded that the backrest can support the sitter's lumbar area more effectively as the pivot position for reclining approaches closer to the hip joint. In this position, the sitter can maintain a comfortable and healthy sitting posture. This paper presents the methods and guidelines for designing an office chair with ergonomic considerations.
All chairs are uncomfortable in the long run, but some chairs become uncomfortable more rapidly than others, and in any particular chair, some people will be more uncomfortable than others. Comfort will depend upon the interaction of chair characteristics, user characteristics, and task characteristics. In this study, we intend to design the comfortable office chair by investigating the anthropometric and biomechanical aspects for Korean. Therefore, we determine the design dimensions using the analysis of anthropometric data. With these dimensions, we design the chair mechanism of which backrest reclines with increasing chair pan declination. This mechanism allows the back to get adequate support at the correct level for any backrest declination. Also, the lumbar support in the backrest descends with increasing backrest reclining. By using this chair, a considerably better sitting posture can be obtained, and uncomfortable feeling and back pain may be prevented.
Lee, Hyun Sim;Park, Young Woo;Kim, Jung Yeon;Lee, Eun Sook;Park, Ai Soon;Han, A Reum;Kim, Eun A;Lee, Ho Sun;Koh, Shin Ok
Journal of Korean Clinical Nursing Research
/
v.14
no.3
/
pp.117-128
/
2008
Purpose: This study was conducted to examine the differences of knowledge, perception, and performance between the points of time before and after ICU nurses had the backrest elevation education. Method: The study subjects were 58 nurses at a medical and surgical ICU of one general Y hospital located in Seoul. They received the education, including backrest elevation guideline and related education materials. Data were collected from May 11 throughout August 12, 2007 with a structured questionnaire. Results: 1) There were significant differences in the mean scores of knowledge(2.21 at pre-education, 5.24 at post-education), perception(36.96 at pre-education, 53.36 at post-education), and performance(32.08 at pre-education, 43.51 at post-education), 2) There was a significant correlation between nurse's perception and performance (p=.000). 3) The nurse's perception regarding the importance of the back rest elevation education was significantly effective on their performance (p=.000). Conclusion: The backrest elevation education would contribute to improve ICU nurse's knowledge, perception and performance. The more the nurses would consider the importance of this education, the better they would perform the nursing intervention of backrest elevation.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.