• 제목/요약/키워드: Backing material

검색결과 50건 처리시간 0.024초

PVDF 초음파 변환기의 제작과 특성에 관한 연구 (A Study on Fabrication and Characteristics of PVDF Ultrasonic Transducer)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제23권2호
    • /
    • pp.33-37
    • /
    • 2000
  • The authors fabricated ultrasonic transducer with PVDF[poly(vinylidene fluoride)] piezoelectric polymer film. When impulse waves were applied to the PVDF ultrasonic transducer, the dependence of the response properties on the backing material with copper was investigated through not only theoretical calculations using Mason's equivalent circuit but also experimental measurements. The experimental pulse response properties agree with those of the theoretical calculations and the pulses were shorter than those for a PZT transducer. If such short-pulse properties are used in an medical ultrasonic image diagnosis apparatus, the resolution of the apparatus will be improved. When the insertion loss was calculated theoretically to the PVDF ultrasonic transducer, the frequency characteristics of its showed wideband frequency.

  • PDF

자동차 브레이크 패드의 기계적 특성 연구 (Mechanical Characteristics of Automobile Brake Pads)

  • 신재호;김경진;강우종
    • 자동차안전학회지
    • /
    • 제7권3호
    • /
    • pp.19-24
    • /
    • 2015
  • Brake pads are a component of disc brake system of automobile and consist of steel backing plates and friction material facing the disk brake rotor. Due to the repeated sliding forces and torque in vehicle braking, friction performance of brake pads are ensured. Futhermore, the brake pad is one of major tuning components in aftermarket, mechanical characteristics of the brake pad are necessary to evaluate for establishing the certification standards of tuning components. This study had performed the five specimen tests for friction coefficients and wear loss rates according to the SAE test specification. Using the instrumented indentation method, yield strength and tensile strength were measured. Friction coefficients, 0.386 - 0.489, and wear loss rates, 1.0% - 3.7% are obtained. The range of yield strength and tensile strength are 21.4 MPa - 105.3 MPa and 39.5 MPa - 176.4 MPa respectively.

과실 비파괴평가용 초음파 변환기 개발 (Development of Ultrasonic Transducer for Nondestructive Evaluation of Whole Fruit)

  • 김기복;이상대;김만수
    • Journal of Biosystems Engineering
    • /
    • 제32권4호
    • /
    • pp.269-275
    • /
    • 2007
  • In this study, ultrasonic transducers for non-destructive contact measurement of whole fruits were developed. The design parameters for ultrasonic transducer such as acoustical impedance of fruits, kinds of piezoelectric materials, ultrasonic wave frequency, and transducer diameter were investigated. In order to match the acoustical impedance between piezoelectric material and fruit, various materials were fabricated and evaluated. Also to control the sensitivity and bandwidth of the ultrasonic transducer, various backing materials were fabricated and evaluated. Especially, the wear plate of the ultrasonic transducer was designed and fabricated considering the curvature of fruit. The central frequencies of two developed ultrasonic transducers were about 100 kHz and 200 kHz, respectively. With the developed ultrasonic transducers, non-destructive evaluation of the fruit will be possible.

가평 현등사 수월관음도의 안료분석 및 보존방법 (Pigment Analysis and Conservation Method of Avalokitesvara in Potalaka of Hyeondeungsa, Gapyeong)

  • 서정호;차병갑;정희수
    • 보존과학회지
    • /
    • 제27권2호
    • /
    • pp.223-229
    • /
    • 2011
  • 불화 문화재는 재료의 특성과 환경적 요인에 의한 색의 변화와 박락현상을 피할 수 없다. 특히 안료 표면에 발생하는 미세한 균열과 탈색 현상의 시작은 곧바로 유물 전체의 안정성이 현저히 급감하는 것으로서, 각별한 조치가 필요하다. 따라서 이 연구는 가평 현등사 수월관음도(경기도무형문화재 제198호)의 보존처리에 관한 것이며 유물 손상 부위를 보존처리하고 안정화시키기 위해 배접과 색맞춤을 실시하고, 안료의 과학적 분석을 수행하였다. XRF, 영상 현미경, FT-IR(자외선 분광 분석법)를 통한 비파괴 분석을 실시하여 유물에 사용한 한지의 재질과 안료의 성분 및 그 특성에 대해 조사하였다. 그 결과 현등사 수월관음도의 한지에서는 우리나라 전통 한지와 일치하는 FT-IR 스펙트럼이 검출되었고, 백색 안료위에 엷은 층을 이루고 있는 흑색 안료는 XRF와 FT-IR로 확인되지 않는 먹이나 그을음 등의 탄소화합물로 추정할 수 있었다. 또한 백색 안료는 Pb와 탄산염을 포함하는 연백($PbCO_3{\cdot}Pb(OH)_2$)이며, 현미경 관찰을 통해 청색 안료의 결정 상태를 확인한 결과 크고 작은 입자 분포를 보였다. XRF 분석 값은 Cu와 Pb 모두 높게 검출된 것으로 보아 청색의 경우 석청과 연백이 혼합되어 사용된 것을 알 수 있었다.

1:50 다목적홀의 음향평가를 위한 축소모형재료의 선정 (Selection of Scale Model Materials for Acoustical Evaluation of 1:50 Multipurpose Halls)

  • 전진용;김정준;김용희
    • 한국음향학회지
    • /
    • 제28권8호
    • /
    • pp.781-789
    • /
    • 2009
  • 다목적홀의 음향을 1:50 축소모형으로 예측 및 평가하기 위해 필요한 모형재료의 구성과 흡음특성에 대해 연구하였다. 실제 홀에서의 반사면 및 가변음항요소, 객석의 설계요소별 흡음특성 (125Hz-lkHz 평균)을 기준으로 축소모형의 형상과 재질을 선정하였으며, 흡음율은 상사의 법칙과 ISO 354를 준용하여 측정하였다. 그 결과, 주벽체의 평균흡음율은 0.08로 래커 코팅된 MDF나 아크릴이 적합하며, 객석 의자, 관객 및 연주자 평균흡음율은 각각 0.64, 0.74와 0.45를 목표로 할때 목재, 흡음천과 폼보드를 조합하여 흡음률을 재현하였다. 흡음커튼과 배너는 적용부위 및 단면설계에 따라 흡음재의 마운팅 방법을 선택하였으며, 배면공기층이 없는 상태 (A형 마운팅)에서의 평균흡음율이 0.42, 0.9 m 배면공기층 조건에서 시료 양단이 고정된 상태 (E형 마운팅)에서는 0.47, 천장에 매단 상태 (G형 마운팅)에서는 0.45로 나타났다. 특히, 배면공기층의 증가에 의해 저주파 대역 흡음력이 증가하였다. 스테이지 하우스 내부는 평균흡음율 0.68의 Fiber glass board 시공을 예상하여 흡음재와 스피커망 원단을 조합하여 재현하였다. 본 연구에서 도출된 모형 재료의 형상과 흡음특성은 향후 1:50 축소모형으로 다목적홀의 형상에 의한 중주파 대역 이하의 음향예측에 유용하게 활용될 것으로 사료된다.

CMP 폐슬러리내의 필터링된 연마 입자 재활용에 관한 연구 (A study on the recycle of reused slurry abrasives)

  • 김기욱;서용진;박성우;정소영;김철복
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.50-53
    • /
    • 2003
  • CMP (chemical mechanical polishing) process remained to solve several problems in deep sub-micron integrated circuit manufacturing process. especially consumables (polishing pad, backing film, slurry, pad conditioner), one of the most important components in the CMP system is the slurry. Among the composition of slurries (buffer solution, bulk solution, abrasive particle, oxidizer, inhibitor, suspension, antifoaming agent, dispersion agent), the abrasive particles are important in determining polish rate and planarization ability of a CMP process. However, the cost of abrasives is still very high. So, in order to reduce the high COO (cost of ownership) and COC (cost of consumables) in this paper, we have collected the silica abrasive powders by filtering after subsequent CMP process for the purpose of abrasive particle recycling. And then, we have studied the possibility of recycle of reused silica abrasive through the analysis of particle size and hardness. Also, we annealed the collected abrasive powders to promote the mechanical strength of reduced abrasion force. Finally, we compared the CMP characteristics between self-developed KOH-based silica abrasive slurry and original slurry. As our experimental results, we obtained the comparable removal rate and good planarity with commercial products. Consequently, we can expect the saving of high cost slurry.

  • PDF

초임계 CO2 발전용 파워 터빈의 회전체 동역학 해석 및 구동 시험 (Rotordynamic Performance Analysis and Operation Test of a Power Turbine for the Super critical CO2 Cycle Application)

  • 이동현;김병옥;선경호;임형수
    • Tribology and Lubricants
    • /
    • 제33권1호
    • /
    • pp.9-14
    • /
    • 2017
  • This paper presents a rotordynamic analysis and the operation of a power turbine applied to a 250 kW super-critical $CO_2$ cycle. The power turbine consists of a turbine wheel and a shaft supported by two fluid film bearings. We use a tilting pad bearing for the power turbine owing to the high speed operation, and employ copper backing pads to improve the thermal management of the bearing. We conduct a rotordynamic analysis based on the design parameters of the power turbine. The dynamic coefficients of the tilting pad bearings were calculated based on the iso-thermal lubrication theory and turbine wheel was modeled as equivalent inertia. The predicted Cambell diagram showed that there are two critical speeds, namely the conical and bending critical speeds under the rated speed. However, the unbalance response prediction showed that vibration levels are controlled within 10 mm for all speed ranges owing to the high damping ratio of the modes. Additionally, the predicted logarithmic decrement indicates that there is no unstable mode. The power turbine uses compressed air at a temperature of $250^{\circ}C$ in its operation, and we monitor the shaft vibration and temperature of the lubricant during the test. In the steady state, we record a temperature rise of $40^{\circ}C$ between the inlet and outlet lubricant and the measured shaft vibration shows good agreement with the prediction.

PMN-PT 압전 단결정을 이용한 고감쇠 재료 비파괴 평가용 초음파 탐촉자 연구 (Study on Ultrasonic Transducer for Non-Destructive Evaluation of Highly Attenuative Material Using PMN-PT Single Crystal)

  • 김기복;안봉영;김영길;박상기;하정수
    • 비파괴검사학회지
    • /
    • 제27권4호
    • /
    • pp.313-320
    • /
    • 2007
  • 일반적으로 비파괴 검사용 초음파 탐촉자는 PZT를 이용한 압전소자가 많이 이용되어 왔다. 최근 압전특성이 PZT보다 크게 뛰어난 PMN-PT 압전 단결정 재료가 개발되어 초음파를 이용한 비파괴 평가 분야에 폭넓게 활용될 것으로 기대되고 있다. 본 연구는 PMN-PT를 이용하여 발전설비 고감쇠 재료의 비파괴 평가에 적합한 초음파 탐촉자를 개발하기 위하여 수행되었다. KLM 모델을 이용하여 초음파 탐촉자의 특성을 시뮬레이션 하였으며 이를 기반으로 하여 중심주파수 1 및 2.25 MHz PMN-PT 종파용 초음파 탐촉자를 제작하여 상용 초음파 탐촉자와 그 성능을 비교하였다.

The Flexible Characteristic of Reversible and Robust Nanohair Fastener

  • Park, Seung-Ho;Yoon, Young-Seok;Lee, Dong-Woo;Lee, Dong-Ik;You, Kyoung-Hwan;Pang, Chang-Hyun;Suh, Kahp-Yang
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.432-432
    • /
    • 2011
  • Dry adhesion caused by Nanoscale contact comes up to important scientific issue. Herein, we introduce bendable nanohairy locking fastener system with high shear strength and mechanically flexible backing. The polymeric patches like velcro are composed of an array of straight nanohairs with 100 nm diameter and $1{\mu}m$ height. To fabricate high aspect vertical nanohairs, we used UV molding method with appropriately flexible and rigid polyurethane acrylate material on PET substrate. Two identical nanohairy patches are easily merged and locked each other induced by van der Waals force. Because nanohairs can be arrayed with high density ${\sim}4{\times}10^8/cm^2$, we can obtain high shear adhesion force on flat surface (~22 N/$cm^2$). Furthermore, we can obtian nanohairy locking system with maximum shear adhesion ~48 N/$cm^2$ of curved surface due to flexibility of PET substrate. We confirm the tendency that shear adhesion force increases, as radius of curvature increases.

  • PDF

조사광이 통과하는 치질의 두께와 광조사시간에 따른 광중합형 복합레진의 중합률에 관한 연구 (A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE THICKNESS OF TOOTH STRUCTURE PENETRATED BY LIGHT AND APPLIED LIGHT CURING TIME)

  • 황기환;장인호;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.16-23
    • /
    • 2002
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc depend on the degree of conversion of the resin components. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the thickness of tooth structure penetrated by light and applied light curing time. The coronal portions of extracted human teeth (one anterior tooth, three posterior tooth) was embedded by pink denture material. the mounted teeth were cut into three illumination sections (1mm thickness enamel section, 1mm thickness dentin section, 2mm thicknes dentin section) and one backing section with cutting wheel. Thin resin films were made by using 6kg pressure between slide glass during 5 minutes Thin resin film was light cured on coupled illumination section during 40sec, 80sec and 120sec. each illumination section was coupled as follows; no tooth structure(X), ename section(E), enamel section + 1mm dentin section(ED1), enamel section + 2mm dentin section(ED2), enamel section + 1mm dentin section + 2mm dentin section(EDD). To simulate the clinical situation more closely, thin resin films was cured against a backing section of tooth structure. The degree of conversion of carbon double bonds to single bonds in the resin films were examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows ; 1 As curing time was increased, conversion rate was increased and as tooth thickness which was penetrated by curing light was increased, conversion rate was decreased. 2. At all tooth thickness groups, conversion rate between 80sec and 120sec was not significantly increased(P>0.05). 3. At 40sec group and 80sec, conversion rate between no tooth structure(X) group and 1mm enamel section(E) group was not significantly decreased(P>0.05). 4. At 80sec group and 120sec, conversion rate between 1mm enamel section(E) group and 1mm enamel section + 1mm dentin section(ED1) group was not significantly decreased(P>0.05).