• 제목/요약/키워드: Background Radiation

검색결과 984건 처리시간 0.027초

Evaluation of the Radiation Pneumonia Development Risk in Lung Cancer Cases

  • Yilmaz, Sercan;Adas, Yasemin Guzle;Hicsonmez, Ayse;Andrieu, Meltem Nalca;Akyurek, Serap;Gokce, Saban Cakir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권17호
    • /
    • pp.7371-7375
    • /
    • 2014
  • Background: Concurrent chemo-radiotherapy is the recommended standard treatment modality for patients with locally advanced lung cancer. The purpose of three-dimensional conformal radiotherapy (3DCRT) is to minimize normal tissue damage while a high dose can be delivered to the tumor. The most common dose limiting side effect of thoracic RT is radiation pneumonia (RP). In this study we evaluated the relationship between dose-volume histogram parameters and radiation pneumonitis. This study targeted prediction of the possible development of RP and evaluation of the relationship between dose-volume histogram (DVH) parameters and RP in patients undergoing 3DCRT. Materials and Methods: DVHs of 41 lung cancer patients treated with 3DCRT were evaluated with respect to the development of grade ${\geq}2$ RP by excluding gross tumor volume (GTV) and planned target volume (PTV) from total (TL) and ipsilateral (IPSI) lung volume. Results: Were admitted statistically significant for p<0.05. Conclusions: The cut-off values for V5, V13, V20, V30, V45 and the mean dose of TL-GTV; and V13, V20,V30 and the mean dose of TL-PTV were statistically significant for the development of Grade ${\geq}2$ RP. No statistically significant results related to the development of Grade ${\geq}2$ RP were observed for the ipsilateral lung and the evaluation of PTV volume. A controlled and careful evaluation of the dose-volume histograms is important to assess Grade ${\geq}2$ RP development of the lung cancer patients treated with concurrent chemo-radiotherapy. In the light of the obtained data it can be said that RP development may be avoided by the proper analysis of the dose volume histograms and the application of optimal treatment plans.

Topical Use of Recombinant Human Epidermal Growth Factor (EGF)-Based Cream to Prevent Radiation Dermatitis in Breast Cancer Patients: a Single-Blind Randomized Preliminary Study

  • Kong, Moonkyoo;Hong, Seong Eon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권8호
    • /
    • pp.4859-4864
    • /
    • 2013
  • Background: The purpose of this study was to assess the effectiveness of a recombinant human epidermal growth factor (EGF)-based cream for the prevention of acute radiation dermatitis in breast cancer patients receiving radiotherapy (RT). Materials and Methods: Between December 2012 and April 2013, 40 breast cancer patients who received postoperative RT were prospectively enrolled in this study and randomly assigned to receive human recombinant EGF-based cream (intervention group) or general supportive skin care (control group). The grade of radiation dermatitis and pain score were examined at weekly intervals during RT and 6 weeks after RT completion. Results: All patients completed the planned RT and complied well with instructions for applying the study cream and general supportive skin care. In the intervention group, radiation dermatitis of maximum grade 3, 2, and 1 developed in 3 (15%), 11 (55%), and 6 patients (30%), respectively. In comparison, in the control group, radiation dermatitis of maximum grade 3, 2, and 1 developed in 8 (40%), 10 (50%), and 2 patients (10%), respectively. The intervention group showed lower incidence of grade 3 radiation dermatitis than the control group (p=0.068 in univariate analysis and p=0.035 in multivariate analysis). There was no statistically significant difference in the maximal pain score between the two groups (p=0.934). Conclusions: This single-blind randomized preliminary study showed that recombinant human EGF-based cream can have a beneficial role in preventing or minimizing radiation dermatitis in breast cancer patients. To confirm the results of our study, additional studies with a large sample size are required.

The Survey about the Degree of Damage of Radiation-Protective Shields in Operation Room

  • Ryu, Jae Sung;Baek, Seung Woo;Jung, Cheol Hee;Cho, Suk Ju;Jung, Eu Gene;Kim, Hae Kyoung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제26권2호
    • /
    • pp.142-147
    • /
    • 2013
  • Background: Medical doctors who perform C-arm fluoroscopy-guided procedures are exposed to X-ray radiation. Therefore, radiation-protective shields are recommended to protect these doctors from radiation. For the past several years, these protective shields have sometimes been used without regular inspection. The aim of this study was to investigate the degree of damage to radiation-protective shields in the operating room. Methods: This study investigated 98 radiation-protective shields in the operation rooms of Konkuk University Medical Center and Jeju National University Hospital. We examined whether these shields were damaged or not with the unaided eye and by fluoroscopy. Results: There were seventy-one aprons and twenty-seven thyroid protectors in the two university hospitals. Fourteen aprons (19.7%) were damaged, whereas no thyroid protectors (0%) were. Of the twenty-six aprons, which have been used since 2005, eleven (42.3%) were damaged. Of the ten aprons, which have been used since 2008, none (0%) was damaged. Of the twenty-three aprons that have been used since 2009, two (8.7%) of them were damaged. Of the eight aprons used since 2010, one (12.3%) was damaged. Of the four aprons used since 2011, none (0%) of them were damaged. The most common site of damage to the radiation-protective shields was at the waist of the aprons (51%). Conclusions: As a result, aprons that have been used for a long period of time can have a higher risk of damage. Radiation-protective shields should be inspected regularly and exchanged for new products for the safety of medical workers.

Radiation exposure to the eyes and thyroid during C-arm fluoroscopy-guided cervical epidural injections is far below the safety limit

  • Choi, Eun Joo;Go, Gwangcheol;Han, Woong Ki;Lee, Pyung-Bok
    • The Korean Journal of Pain
    • /
    • 제33권1호
    • /
    • pp.73-80
    • /
    • 2020
  • Background: The aim of this study was to evaluate radiation exposure to the eye and thyroid in pain physicians during the fluoroscopy-guided cervical epidural block (CEB). Methods: Two pain physicians (a fellow and a professor) who regularly performed C-arm fluoroscopy-guided CEBs were included. Seven dosimeters were used to measure radiation exposure, five of which were placed on the physician (forehead, inside and outside of the thyroid protector, and inside and outside of the lead apron) and two were used as controls. Patient age, sex, height, and weight were noted, as were radiation exposure time, absorbed radiation dose, and distance from the X-ray field center to the physician. Results: One hundred CEB procedures using C-arm fluoroscopy were performed on comparable patients. Only the distance from the X-ray field center to the physician was significantly different between the two physicians (fellow: 37.5 ± 2.1 cm, professor: 41.2 ± 3.6 cm, P = 0.03). The use of lead-based protection effectively decreased the absorbed radiation dose by up to 35%. Conclusions: Although there was no difference in radiation exposure between the professor and the fellow, there was a difference in the distance from the X-ray field during the CEBs. Further, radiation exposure can be minimized if proper protection (thyroid protector, leaded apron, and eyewear) is used, even if the distance between the X-ray beam and the pain physician is small. Damage from frequent, low-dose radiation exposure is not yet fully understood. Therefore, safety measures, including lead-based protection, should always be enforced.

Short-Term Changes in Gut Microflora and Intestinal Epithelium in X-Ray Exposed Mice

  • Tsujiguchi, Takakiyo;Yamaguchi, Masaru;Yamanouchi, Kanako
    • Journal of Radiation Protection and Research
    • /
    • 제45권4호
    • /
    • pp.163-170
    • /
    • 2020
  • Background: Gut microflora contributes to the nutritional metabolism of the host and to strengthen its immune system. However, if the intestinal barrier function of the living body is destroyed by radiation exposure, the intestinal bacteria harm the health of the host and cause sepsis. Therefore, this study aims to trace short-term radiation-induced changes in the mouse gut microflora-dominant bacterial genus, and analyze the degree of intestinal epithelial damage. Materials and Methods: Mice were irradiated with 0, 2, 4, 8 Gy X-rays, and the gut microflora and intestinal epithelial changes were analyzed 72 hours later. Five representative genera of Actinobacteria, Firmicutes, and Bacteroidetes were analyzed in fecal samples, and the intestine was pathologically analyzed by Hematoxylin-Eosin and Alcian blue staining. In addition, DNA fragmentation was evaluated by the TdT-mediated dUTP nick-end labeling (TUNEL) assay. Results and Discussion: The small intestine showed shortened villi and reduced number of goblet cells upon 8 Gy irradiation. The large intestine epithelium showed no significant morphological changes, but the number of goblet cells were reduced in a radiation dose-dependent manner. Moreover, the small intestinal epithelium of 8 Gy-irradiated mice showed significant DNA damaged, whereas the large intestine epithelium was damaged in a dose-dependent manner. Overall, the large intestine epithelium showed less recovery potential upon radiation exposure than the small intestinal epithelium. Analysis of the intestinal flora revealed fluctuations in lactic acid bacteria excretion after irradiation regardless of the morphological changes of intestinal epithelium. Altogether, it became clear that radiation exposure could cause an immediate change of their excretion. Conclusion: This study revealed changes in the intestinal epithelium and intestinal microbiota that may pave the way for the identification of novel biomarkers of radiation-induced gastrointestinal disorders and develop new therapeutic strategies to treat patients with acute radiation syndrome.

Preliminary study for the development of radiation safety evaluation methodology for industrial kV-rated radiation generator facilities

  • Hye Sung Park ;Na Hye Kwon ;Sang Rok Kim ;Hwidong Yoo;Jin Sung Kim ;Sang Hyoun Choi;Dong Wook Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3854-3859
    • /
    • 2023
  • Background: This study aims to develop an evaluator that can quickly and accurately evaluate the shielding of low-energy industrial radiation generators. Methods: We used PyQt to develop a graphical user interface (GUI)-based program and employed the calculation methodology reported in the National Council on Radiation Protection and Measurements (NCRP)-49 for shielding calculations. We gathered the necessary factors for shielding evaluation using two libraries designed for Python, pandas and NumPy, and processed them into a database. We verified the effectiveness of the proposed program by comparing the results with those from safety reports of six domestic facilities. Results: After verifying the effectiveness of the program using the NCRP-49 example, we obtained an average error rate of 1.73%. When comparing the facility safety report and results obtained using the program, we found that the error rate was between 1.09% and 6.51%. However, facilities that did not use a defined shielding methodology were underestimated by 31.82% compared with the program (the final barrier thickness satisfied the shielding standard). Conclusion: The developed program provides a fast and accurate shielding evaluation that can assist personnel that work in radiation generator facilities and government officials in reviewing safety.

Optimization of Yonsei Single-Photon Emission Computed Tomography (YSECT) Detector for Fast Inspection of Spent Nuclear Fuel in Water Storage

  • Hyung-Joo Choi;Hyojun Park;Bo-Wi Cheon;Kyunghoon Cho;Hakjae Lee;Yong Hyun Chung;Yeon Soo Yeom;Sei Hwan You;Hyun Joon Choi;Chul Hee Min
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.29-39
    • /
    • 2024
  • Background: The gamma emission tomography (GET) device has been reported a reliable technique to inspect partial defects within spent nuclear fuel (SNF) of pin-by-pin level. However, the existing GET devices have low accuracy owing to the high attenuation and scatter probability for SNF inspection condition. The purpose of this study is to design and optimize a Yonsei single-photon emission computed tomography version 2 (YSECT.v.2) for fast inspection of SNF in water storage by acquisition of high-quality tomographic images. Materials and Methods: Using Geant4 (Geant4 Collaboration) and DETECT-2000 (Glenn F. Knoll et al.) Monte Carlo simulation, the geometrical structure of the proposed device was determined and its performance was evaluated for the 137Cs source in water. In a Geant4-based assessment, proposed device was compared with the International Atomic Energy Agency (IAEA)-authenticated device for the quality of tomographic images obtained for 12 fuel sources in a 14 × 14 Westinghouse-type fuel assembly. Results and Discussion: According to the results, the length, slit width, and septal width of the collimator were determined to be 65, 2.1, and 1.5 mm, respectively, and the material and length of the trapezoidal-shaped scintillator were determined to be gadolinium aluminum gallium garnet and 45 mm, respectively. Based on the results of performance comparison between the YSECT.v.2 and IAEA's device, the proposed device showed 200 times higher performance in gamma-detection sensitivity and similar source discrimination probability. Conclusion: In this study, we optimally designed the GET device for improving the SNF inspection accuracy and evaluated its performance. Our results show that the YSECT.v.2 device could be employed for SNF inspection.

STUDY ON THERMAL MODELING METHODS OF A CYLINDRICAL GROUND OBJECT CONSIDERING THE SPECTRAL SOLAR RADIATION THROUGH THE ATMOSPHERE

  • Choi Jun-Hyuk;Choi Mi-Na;Gil Tae-Jun;Kim Tae-Kuk
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.205-208
    • /
    • 2005
  • This research is aimed at the development of a software that predicts the surface temperature profiles of three-dimensional objects on the ground considering the spectral solar radiation through the atmosphere. The thermal modelling is essential for identifying the objects on the scenes obtained from the satellites. And the temperature distribution on the objects is necessary to obtain their infrared images in contrast to the background. We developed a software that could be used to model the thermal problems of the ground objects irradiated by the spectral solar radiation. This software can be used to handle the conduction within the object as a one-dimensional mode into the depth or as a three-dimensional mode through the media. LOWTRAN7 is used to model the spectral solar radiation including the direct and diffuse solar radiances. In this paper, temperature distributions on the objects obtained by using the one-dimensional and the three-dimensional thermal models are compared with each other to examine the applicability of the relatively easy-to-apply one-dimensional model.

  • PDF

Comparison of Off-site Radiological Dose Due to the Routine Release of Gaseous Radioactive Effluents Based on the Korean and Japanese Regulatory Recommendations

  • Hwang, Won Tae;Kim, Chang Lak;Lee, Cheol-Woo;Han, Moon Hee
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.161-165
    • /
    • 2019
  • Background: Not only regulatory framework including radiation protection quantities and regulatory standards, but also methodology for regulatory compliance may be different in each country due to inherent philosophy for radiation protection. Materials and Methods: Based on the Korean regulatory models, off-site radiological dose resulting from the routine releases of gaseous radioactive effluents was calculated by applying the parameter values and assumptions recommended in the Korean and Japanese regulations. Results and Discussion: Effective dose for adult based on the Korean recommendation were 17.5 and 1.6 times higher than those of Japanese recommendation for 131I and 133I, respectively, for the same atmosphere dispersion and ground deposition factors. Conclusion: It was due to different parameter values and assumptions recommended for the purpose of evaluating compliance with dose criteria for the radiation protection of the public in each country.

진행성 두경부암에서 선행항암요법과 방사선요법의 치료성적 (Neoadjuvant Chemotherapy and Radiotherapy in the Treatment of Advanced Head and Neck Cancer : Protocol Based Study)

  • 김철호;최진혁;이진석;오영택
    • 대한두경부종양학회지
    • /
    • 제20권2호
    • /
    • pp.172-176
    • /
    • 2004
  • Background and Objectives: Standard treatment of locally advanced laryngeal, hypopharyngeal, and some oropharyngeal cancers includes total laryngectomy. In an attempt to preserve the larynx through induction chemotherapy, we designed induction chemotherapy followed by definitive radiation in patients with potentially respectable head and neck cancer to determine whether organ preservation is feasible without apparent compromise of survival. Materials and Methods: The twenty-six patients diagnosed advanced head and neck squamous cell carcinoma, Stage III or IV (AJCC 2002) and performed organ preservation protocols in Ajou university hospital from 1994 to 2001 were included in this study. Results: Neoadjuvant chemotherapy showed an overall response rate of 84.6% and a complete remission (CR) rate was 59.1% following neoadjuvant chemotherapy and radiation. Seven of thirteen patients were able to preserve their larynges for more than two years by chemotherapy and radiation. There were no treatment related mortality after 2 cycles of induction chemotherapy. Conclusion: Although Organ preservation protocol through neoadjuvant chemotherapy and radiation need more controlled randomized study, it was considered alternative treatment modality in advanced head and neck cancer.