• Title/Summary/Keyword: Back-to-back converter

Search Result 218, Processing Time 0.03 seconds

Construction of Feed-back Type Flux-gate Magnetometer (피드백형 플럭스게이트 마그네토미터 제작)

  • Son, De-Rac
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.2
    • /
    • pp.45-48
    • /
    • 2012
  • Feed-back type 3-axis flux-gate magnetometer using Co-based amorphous ribbon (Metglass$^{(R)}$2714A) was constructed in this work. Measuring range of magnetic field and frequency were ${\pm}100\;{\mu}T$ and dc~10 Hz respectively. For the interface to computer, microcontroller and 24 bit ADC (Analog to Digital Converter) were employed and resolution of digital output was 0.1 nT. Magnetometer noise of analog output was 5 pT/$\sqrt{Hz}$ at 1 Hz. Digital output of the magnetometer showed linearity of $1{\times}10^{-4}$ and the offset drift was smaller than 0.2 nT during 1 h.

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

Optimal Soft-Switching Scheme for Bidirectional DC-DC Converters with Auxiliary Circuit

  • Lee, Han Rim;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.681-693
    • /
    • 2018
  • This paper proposes a soft-switching bidirectional dc-dc converter (BDC) with an auxiliary circuit. The proposed BDC can achieve the zero-voltage switching (ZVS) using an auxiliary circuit in the buck and boost operations. The auxiliary circuit supplies optimal energy for the ZVS operation of the main switches. The auxiliary circuit consists of a resonant inductor, a back-to-back switch and two capacitors. A small-sized resonant inductor and an auxiliary switch with a low-rated voltage can be used in the auxiliary circuit. Zero-current switching (ZCS) turn-on and turn-off of the auxiliary switches are possible. The proposed soft-switching scheme has a look-up table for optimal switching of the auxiliary switches. The proposed strategy properly adjusts the turn-on time of the auxiliary switch according to the load current. The proposed BDC is verified by the results of PSIM simulations and experiments on a 3-kW ZVS BDC system.

Voltage Balancing Circuit for Li-ion Battery System (리튬-이온 배터리 시스템을 위한 전압안정화 회로)

  • Park, Kyung Hwa;Yi, Kang Hyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.73-80
    • /
    • 2013
  • Recently, Li-ion battery is regarded as a potential energy storage device in the lime light and it can supply power to the satellite very effectively during eclipse. Because it has better features as high voltage range, large capacity and small volume than any other battery. Generally, multi cells are connected in series to use Li-ion batteries in satellite application. Since the internal resistance of cells is different each other, voltage in some cells can be overcharged or undercharged, so capacity of the cell is reduced and the life of whole battery pack is decreased. Therefore, a voltage balancing circuit with Fly-back converter is proposed and the voltage equalization of each cell is verified the prototype in this paper.

Load Simulator with Power-Recovery Capability Based on Voltage Source Converter-Inverter Set (전력회수 능력을 갖는 전압원 컨버터-인버터 세트로 구성된 부하모의장치)

  • Bae B.Y.;Han B.M.
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.76-80
    • /
    • 2004
  • This paper describes a load simulator with power-recovery capability, which is based on the voltage source converter-inverter set. The load simulator described in this paper can save the electric energy that should be consumed to test the operation and performance of the distributed generation system and the power quality compensator. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. The load simulator can be widely used in the lab to test the performance of the distributed generation system and the power quality compensator.

  • PDF

Load Simulator with Power-Recovery Capability Based on Voltage Source Converter-Inverter Set (전력회수 능력을 갖는 전압원 컨버터-인버터 세트로 구성 된 부하모의 장치)

  • Bae Byung-Yeol;Han Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.4
    • /
    • pp.181-187
    • /
    • 2005
  • This paper describes a load simulator with power-recovery capability, which is based on the voltage source converter-inverter set. The load simulator described in this paper can save the electric energy that should be consumed to test the operation and performance of the distributed generation system and the power quality compensator. The load simulator consists of a converter-inverter set with a DSP controller for system control and PWM pulse generation. The converter operates as a universal load to model the linear load and the non-linear load, while the inverter feed the energy back to the power source with harmonic compensation. The load simulator can be widely used in the lab to test the performance of the distributed generation system and the power quality compensator.

PMSG Wind Turbine Simulation under the consideration of real characteristics (PMSG 풍력 터빈의 특성을 고려한 발전 시스템 시뮬레이션)

  • Sim, Junbo;Kim, Myungho;Park, Kihyeon;Han, Kyungseop
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.182.2-182.2
    • /
    • 2010
  • A various algorism has been studied to extract possibly every energy from a wind turbine in conjunction with the increase of concern about wind power system. In order to verify these control algorism, it is essential to make the most similar conditions to the real wind turbine's environment. Therefore, using separately excited DC motor a wind turbine the most similar to the real turbine is simulated. Tower shadow effect and Wind shear effect are considered as well as inertia emulation. For the control of Back-to-Back Converter Vector current control methods and space vector pulse width modulation are used and for reducing THD of grid current LCL filter is considered. This simulation results verified the energy produced by wind all flows into the utility under the consideration of the characteristics of a wind turbine. The result of this paper is expected to be used as a basic material for analyzing the characteristics of the wind turbine generator.

  • PDF

Study on Real-Time Load Simulator for Testing Propulsion Inverter Test (추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구)

  • 김길동;신정렬;이우동;한석윤;박기준
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.

Novel High Boost DC Power Supply (새로운 고승압 직류전원장치)

  • Baek J. W.;Ryu M. H.;Yoo D. W.;Kim T. J.;Lee B. K.;Rim G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.815-818
    • /
    • 2004
  • The emerging applications such as reliable back-up power system and renewable energy call for high boost U-n converter. The conventional topologies to get high output voltage are using flyback circuit, cascade converters, and coupled inductor DC-DC converter. They have the stress and loss related to the leakage energy which results in low efficiency Tn this paper, novel high boost converter is presented. It has a structure of cascade boost converter but only one switch. Therefore, drive circuit is simple and extreme duty ratio is eliminated. To verify the proposed circuit, theoretical analysis and experimental results has been done using a prototype power supply.

  • PDF

Power Flow Control of a Multi-bus/Three-feeder Distribution System Using Generalized Unified Power Quality Conditioner

  • Mohammed, B.S.;Ibrahim, R.;Perumal, N.;Rao, K.S. Rama
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2015
  • This paper analyses the power flow of a three-feeder/multi-bus distribution system by a custom Generalized Power Quality Conditioner (GUPQC). The GUPQC has been realized by three voltage source converters (VSCs) coupled back-to-back through a common DC-link capacitor on the DC-side. One feeder was controlled by the shunt compensator, whereas each of the other two feeders was controlled by the proposed novel series compensator. The GUPQC has the capability to simultaneously compensate voltage and current quality problems of a multi-bus/three-feeder distribution system. Besides that, the power can be transferred from one feeder to other feeders to compensate for poor power quality problems. Extensive simulation studies were carried out by using MATLAB/SIMULINK software to establish the ability of the GUPQC to improve power quality of the distribution systems under distorted supply voltage conditions.