• Title/Summary/Keyword: Back-contact

Search Result 366, Processing Time 0.025 seconds

Ga Distribution in Cu(In,Ga)Se2 Thin Film Prepared by Selenization of Co-Sputtered Cu-In-Ga Precursor with Ga2Se3 Layer (Ga2Se3 층을 Cu-In-Ga 전구체 위에 적용하여 제조된 Cu(In,Ga)Se2 박막의 Ga 분포 변화 연구)

  • Jung, Gwang-Sun;Shin, Young-Min;Cho, Yang-Hwi;Yun, Jae-Ho;Ahn, Byung-Tae
    • Korean Journal of Materials Research
    • /
    • v.20 no.8
    • /
    • pp.434-438
    • /
    • 2010
  • The selenization process has been a promising method for low-cost and large-scale production of high quality CIGS film. However, there is the problem that most Ga in the CIGS film segregates near the Mo back contact. So the solar cell behaves like a $CuInSe_2$ and lacks the increased open-circuit voltage. In this study we investigated the Ga distribution in CIGS films by using the $Ga_2Se_3$ layer. The $Ga_2Se_3$ layer was applied on the Cu-In-Ga metal layer to increase Ga content at the surface of CIGS films and to restrict Ga diffusion to the CIGS/Mo interface with Ga and Se bonding. The layer made by thermal evaporation was showed to an amorphous $Ga_2Se_3$ layer in the result of AES depth profile, XPS and XRD measurement. As the thickness of $Ga_2Se_3$ layer increased, a small-grained CIGS film was developed and phase seperation was showed using SEM and XRD respectively. Ga distributions in CIGS films were investigated by means of AES depth profile. As a result, the [Ga]/[In+Ga] ratio was 0.2 at the surface and 0.5 near the CIGS/Mo interface when the $Ga_2Se_3$ thickness was 220 nm, suggesting that the $Ga_2Se_3$ layer on the top of metal layer is one of the possible methods for Ga redistribution and open circuit voltage increase.

Na Doping Properties of Cu(In,Ga)Se2 Absorber Layer Using NaF Interlayer on Mo Substrate (Mo 기판위의 NaF 중간층을 이용한 Cu(In,Ga)Se2 광흡수층의 Na 도핑특성에 관한 연구)

  • Park, Tae-Jung;Shin, Dong-Hyeop;Ahn, Byung-Tae;Yun, Jae-Ho
    • Korean Journal of Materials Research
    • /
    • v.19 no.8
    • /
    • pp.452-456
    • /
    • 2009
  • In high-efficiency Cu(In,Ga)$Se_2$ solar cells, Na is doped into a Cu(In,Ga)$Se_2$ light-absorbing layer from sodalime-glass substrate through Mo back-contact layer, resulting in an increase of device performance. However, this supply of sodium is limited when the process temperature is too low or when a substrate does not supply Na. This limitation can be overcome by supplying Na through external doping. For Na doping, an NaF interlayer was deposited on Mo/glass substrate. A Cu(In,Ga)$Se_2$ absorber layer was deposited on the NaF interlayer by a three-stage co-evaporation process As the thickness of NaF interlayer increased, smaller grain sizes were obtained. The resistivity of the NaF-doped CIGS film was of the order of $10^3{\Omega}{\cdot}cm$ indicating that doping was not very effective. However, highest conversion efficiency of 14.2% was obtained when the NaF thickness was 25 nm, suggesting that Na doping using an NaF interlayer is one of the possible methods for external doping.

Optimization of Drive-in Process with Various Times and Temperatures in Crystalline Silicon Solar Cell Fabrication (결정질 실리콘 태양전지 도핑 확산 공정에서 시간과 온도 변화에 의한 Drive-in 공정 연구)

  • Lee, Hee-Jun;Choi, Sung-Jin;Myoung, Jae-Min;Song, Hee-Eun;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.51-55
    • /
    • 2011
  • In this paper, the optimized doping condition of crystalline silicon solar cells with 156 ${\times}$ 156 mm2 area was studied. To optimize the drive-in condition in the doping process, the other conditions except drive-in temperature and time were fixed. After etching 7 ${\mu}m$ of the surface to form the pyramidal structure, the silicon nitride deposited by the PECVD had 75~80 nm thickness and 2 to 2.1 for a refractive index. The silver and aluminium electrodes for front and back sheet, respectively, were formed by screen-printing method, followed by firing in $400-425-450-550-850^{\circ}C$ five-zone temperature conditions to make the ohmic contact. Drive-in temperature was changed in range of $828^{\circ}C$ to $860^{\circ}C$ and time was from 3 min to 40 min. The sheet resistance of wafer was fixed to avoid its effect on solar cell. The solar cell fabricated with various conditions showed the similar conversion efficiency of 17.4%. This experimental result showed the drive-in temperatures and times little influence on solar cell characteristics.

  • PDF

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

A Study on the Adaptive Reuse Techniques through the History of Buildings in the Historic Urban Area - Focused on the Deep and Narrow Lots of Nammun-ro 2Ga, Cheongju - (역사적 도심 내 건축물의 이력을 통해 본 재생기법에 관한 연구 -청주시 남문로 2가동의 세장형 필지를 대상으로-)

  • Kim, Tai-Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.22 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • This study is intended to derive the adaptive reuse techniques through the history and aspects of new construction, extension, repair, and other works, limited to the deep and narrow lots facing Seongan-gil and Nammun-gil in Nammun-ro 2 ga of Cheongju, the historic urban area. The results are as follows. 1) In the case of newly built reinforced concrete buildings, the central part of the top floor of the residence or all floors are opened to the open space(void) to facilitate lighting and ventilation. This is developed as a convection phenomenon due to the temperature difference from the slits between buildings, which affects the entire air flow of the block. 2) The buildings of extension and repair are composed of two-story masonry or steel frame, both the front store facing the road and the house on the back, but it looks like one because it is in contact with each other. If only a small gap between the front and rear buildings is restored to an external space or a space equipped with sun light, a small breath can be provided in lighting and ventilation. 3) The existing two-story wooden stores and houses have lost their external space due to repairs. With minimal intervention to restore the small courtyard, slits, and space under the eaves, it will not only improve lighting and ventilation, but also create a unique appearance as a segment of the elongated store.

Intelligent Control of a Virtual Walking Machine for Virtual Reality Interface (가상현실 대화용 가상걸음 장치의 지능제어)

  • Yoon, Jung-Won;Park, Jang-Woo;Ryu, Je-Ha
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.926-934
    • /
    • 2006
  • This paper proposes intelligent control of a virtual walking machine that can generate infinite floor for various surfaces and can provide proprioceptive feedback of walking to a user. This machine allows users to participate in a life-like walking experience in virtual environments with various terrains. The controller of the machine is implemented hierarchically, at low-level for robust actuator control, at mid-level fur platform control to compensate the external forces by foot contact, and at high-level control for generating walking trajectory. The high level controller is suggested to generate continuous walking on an infinite floor for various terrains. For the high level control, each independent platform follows a man foot during the swing phase, while the other platform moves back during single stance phase. During double limb support, two platforms manipulate neutral positions to compensate the offset errors generated by velocity changes. This control can, therefore, satisfy natural walking conditions in any direction. Transition phase between the swing and the stance phases is detected by using simple switch sensor system, while human foot motions are sensed by careful calibration with a magnetic motion tracker attached to the shoe. Experimental results of walking simulations at level ground, slope, and stairs, show that with the proposed machine, a general person can walk naturally on various terrains with safety and without any considerable disturbances. This interface can be applied to various areas such as VR navigations, rehabilitation, and gait analysis.

Modeling of Force Components Acting on Quay Walls During Earthquakes (지진시 중력식 안벽에 작용하는 하중성분의 모델링)

  • 김성렬;권오순;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.107-121
    • /
    • 2003
  • When the seismic stability of quay walls is analyzed, the magnitudes of force components acting on quay walls during earthquakes and the phase relations among these force components must be properly evaluated. In general, force components include inertia force of the quay wall, lateral earth force, and water force. The magnitude and the phase relation of each force component vary according to the magnitude of the excess pore pressures developed in backfill soils of the quay wall. The dynamic thrust mobilized at the contact surface between the backfill soil and the wall develops as a result of the interactions among these force components. We propose a simple model to evaluate the magnitude and phase variation of the dynamic thrust on the back of the wall in terms of the excess pore pressure. The proposed model can predict the dynamic thrust by summing the magnitudes of farce components calculated from design equations for seismic pressures on the wall. The proposed model was verified by comparing its results with the results from a series of shaking table tests.

Damage Pattern and Operation Characteristics of a Thermal Magnetic Type MCCB according to Thermal Stress (열동전자식 MCCB의 열적 스트레스에 따른 소손 패턴 및 작동 특성)

  • Lee, Jae-Hyuk;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.69-73
    • /
    • 2013
  • The purpose of this paper is to analyze the carbonization pattern and operation characteristics of an MCCB. The MCCB is consisted of the actuator lever, actuator mechanism, bimetallic strip, contacts, up and down operator, arc divider or extinguisher, metal operation pin, terminal part, etc. When the actuator lever of the MCCB is at the top or the internal metal operation pin is in contact with the front part, the MCCB is turned on or off. It means trip state if the actuator lever or the internal metal operation pin moves to back side. In the UL 94 vertical combustion test, white smoke occurred from the MCCB when an average of 17~24 seconds elapsed after the MCCB was ignited and black smoke occurred when an average of 45~50 seconds elapsed. It took 5~6 minutes for the MCCB surface to be half burnt and took an average of 8~9 minutes for the MCCB surface to be entirely burnt. In the UL 94 test, the MCCB trip device operated when an average 7~8 minutes elapsed. If the MCCB trip has occurred, it may have been caused by an electrical problem such as a short-circuit, overcurrent, etc., as well as fire heat. From the entire part combustion test according to KS C 3004, it was found that the metal operation pin could be moved to the MCCB trip position without any electrical problems.

Aerodynamic Approaches for the Predition of Spread the HPAI (High Pathogenic Avian Influenza) on Aerosol (고병원성 조류인플루엔자 (HPAI)의 에어로졸을 통한 공기 전파 예측을 위한 공기유동학적 확산 모델 연구)

  • Seo, Il-Hwan;Lee, In-Bok;Moon, Oun-Kyung;Hong, Se-Woon;Hwnag, Hyun-Seob;Bitog, J.P.;Kwon, Kyeong-Seok;Kim, Ki-Youn
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.1
    • /
    • pp.29-36
    • /
    • 2011
  • HPAI (High pathogenic avian influenza) which is a disease legally designated as an epidemic generally shows rapid spread of disease resulting in high mortality rate as well as severe economic damages. Because Korea is contiguous with China and southeast Asia where HPAI have occurred frequently, there is a high risk for HPAI outbreak. A prompt treatment against epidemics is most important for prevention of disease spread. The spread of HPAI should be considered by both direct and indirect contact as well as various spread factors including airborne spread. There are high risk of rapid propagation of HPAI flowing through the air because of collective farms mostly in Korea. Field experiments for the mechanism of disease spread have limitations such as unstable weather condition and difficulties in maintaining experimental conditions. In this study, therefore, computational fluid dynamics which has been actively used for mass transfer modeling were adapted. Korea has complex terrains and many livestock farms are located in the mountain regions. GIS numerical map was used to estimate spreads of virus attached aerosol by means of designing three dimensional complicated geometry including farm location, road network, related facilities. This can be used as back data in order to take preventive measures against HPAI occurrence and spread.

Effect of Trunk Flexion and Low Extremity Posture on Maximum Holding Time (허리굽힘과 다리자세가 작업지속시간에 미치는 영향에 관한 연구)

  • Lee, Se-Jung;Chang, Seong-Rok
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.69-74
    • /
    • 2011
  • Despite most of tasks in manufacturing, construction and agriculture, etc., were currently mechanized and automated, manual materials handling still existed in atypical working condition. In case of manual materials handling, repetitive work, inappropriate working posture, excessive force, contact stress might cause overload, which could lead to work-related musculoskeletal disorders and low back pains. On this basis, the goal of this study is to reveal the effects of various lifting postures of trunk angles and lower extremity postures on maximum holding time(MHT). Twenty two subjects were recruited from a university population. The experiment was designed by a combination of three trunk angle ($0^{\circ}$, $20^{\circ}$, $60^{\circ}$) and three lower extremity postures(straight, bent, kneeling). Before experimental trials, subjects performed MVC(maximum voluntary contraction) exertions in three trunk angles ($0^{\circ}$, $20^{\circ}$, $60^{\circ}$) to calculate 30%MVC at designated postures. In each trial, they were required to hold the handheld load(30%MVC) for a designated posture as long as they could. The results of MVC by trunk angles were measured in $0^{\circ}$ > $20^{\circ}$ > $60^{\circ}$ orders, but those of MHT measured in $20^{\circ}$ > $0^{\circ}$ > $60^{\circ}$ orders. These results showed that straight posture is the ideal working posture in work exerted a strong force for a short time, but the ability to work might be improved in the trunk angle $20^{\circ}$ in work required 30%MVC for a long time. Also, results of MVC and MHT by lower extremity postures measured in straight > bent > kneeling orders.