• Title/Summary/Keyword: Back ground noise

Search Result 35, Processing Time 0.028 seconds

A NEW METHOD FOR NORTH-SOUTH ASYMMETRY OF SUN SPOT AREA ANALYSIS

  • Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • 제24권4호
    • /
    • pp.261-268
    • /
    • 2007
  • We have studied the temporal variation in the North-South asymmetry of the sunspot area during the period from 1874 to 2007. Though the 9-year periodicity is commonly reported, shorter periodicities is still under study. We employ the cepstrum analysis method to analyze the noisy power spectrum of the North-South asymmetry. We demonstrate that the cleaned power spectrum shows reduction of the spurious back-ground noise level. Some of short period peaks in the power spectrum disappear after deconvolution. It should be, however, pointed out that power spectrum might look less noisy because of a filtering process during deconvolution. We conclude by pointing out that a more sophisticate filtering algorithm is required to produce a precise and reliable periodicity estimate.

극박 냉연강판의 경사진 핀홀 검출에 관한 연구 (The Measurement of The Inclined Pinhole in The Cold Strip)

  • 김하술;배호문;이희준
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.201-207
    • /
    • 1999
  • The automatic pinhole detection system is described. The goal of this project is to study the feasibility test of the new concept for hole detection. The developed method is able to detect almost 50$\mu\textrm{m}$ pinhole by evaluating the shining of the light as if there is pinhole in the strip. Moreover, it is possible to inspect up to the 200$\mu\textrm{m}$ inclined pinhole. The system cosists of three main functional parts: the source part of the light which is using the linear halogen lamp, the image gathering part which is using a line CCD and the image processing part. The light spot can be controlled and optimized corresponding to the situation of the strip. To eliminate back ground noise, the binary image processing method is adopted.

  • PDF

LMS PHD에 의한 배경단파 파워 스펙트럼 추정 (Power Spectral Estimation of Background EEG with LMS PHD)

  • 정명진;최갑석
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.101-108
    • /
    • 1988
  • In this paper the power spectrum of background EEG is estimated by the LMS PHD based on least mean square. At the power spectrum estimatiom, the stocastic process of background EEG is assumed to consist of the nonharmonic sinusoid and the white noise. In the LMS PHD the model parameters are obtained by the least mean square at optimal order which is obtained from the fact that the eigenvalue's fluctuation of autocorrelation matrix of the normal back-ground EEG is smaller at some order than at other order when the power spectrum of background EEG is esitmated by PHD. The optimal order of this model is the 6-th order when the eigenvalue's fluctuation of autocorrelation matrix of background EEG is considered. The estimation results are with compared the results from the Maximum Entropy Spectral Estimation and Pisarenko Harmonic Decomposition. From the comparison results. The LMS PHD is possible to estimate the power spectrum of background EEG.

  • PDF

사카모토의 방법을 이용한 수치지도 워터마킹 (Digital Map Watermarking Using sakamoto algorithm)

  • 박귀태;김갑일;강환일;한승수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2797-2799
    • /
    • 2002
  • In this paper, the algorithm is suggested for inserting and extracting the watermark in the digital map of vector form. This kind of algorithm was first anounced by the sakamoto[1]. In order to use watermarking in the digital map, the map is analyzed and experimented to protect the map data. As for the vector watermarking, there are few references and need more research for the theoretical back ground. As for this, in this paper, experiment of the immunity against the noise is conducted for the selection of the proper immunity factor.

  • PDF

소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가 (The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT)

  • 김구;김경립;이은숙;조희정;성순기;문슬지아;곽종혁
    • 한국콘텐츠학회논문지
    • /
    • 제19권8호
    • /
    • pp.284-292
    • /
    • 2019
  • 소아 흉부 CT 검사 시 방사선 피폭을 최소화 하면서 진단적으로 가치가 높은 영상을 얻기 위해서 Helical mode, High-pitch mode, Volume Axial mode를 적용하여서 선량, 검사시간, 화질을 비교하여 유용성을 평가하고자 한다. Revolution(GE Healthcare, Wisconsin USA)을 이용하여 PBU-70팬텀을 Helical mode, High-pitch mode, Volume Axial mode로 각각의 그룹으로 나누어서 관전압 80kVp, 조건으로 30회 검사를 실시하였다. 영상을 획득 한 후에 각각의 영상에 심장(Heart), 뼈(Bone), 폐(Lung), Back-ground air에 ROI를 설정하고 CT number(HU)와 noise(SD)값을 측정하여 평균값을 구하고 SNR과 CNR을 측정하였고, 장비에서 직접 제공하는 DLP값 비교하였다. 통계적인 유의성을 확인해보기 통계 분석은 SPSS 21.0을 사용하여 ONE-WAY-ANAOVA를 시행하였다. 본 실험을 통해 검사 시 volume axial mode 사용 시 가장 적은 선량으로 영상의 화질 저하 없이 빠른 시간에 검사가 가능하였다. 16cm의 detector coverage 가 모든 소아 흉부 CT검사에 적용하기에 제한점이 있으나 가능한 소아환자에 있어 적극적인 활용을 추천하며 volume axial mode의 다른 검사부위 적용에 대한 지속적인 연구가 필요하리라 사료된다.

흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구 (A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom)

  • 황혜성;김누리;정윤지;구은회;김기정
    • 대한디지털의료영상학회논문지
    • /
    • 제16권2호
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

동잡음 저감을 위한 심전도 전극 특성에 대한 연구 (Study on Characteristics of ECG Electrodes for Motion Artifact Reduction)

  • 강영환;박재순;조범기;최상동;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.366-371
    • /
    • 2017
  • In this paper, we introduce an electrocardiogram (ECG) system designed to solve problems caused by wetgels and motion artifacts in measuring active movement. The system is called a dry-contact ECG and was designed by considering impedance matching between skin and electrode as well as the frictional electricity between electrode and clothes. In order to create the system, we measured impedance on the skin-electrode interface, and the result was applied to the electronic circuit scheme. Moreover, we added an electrode on the back of the measurement electrode to make a flow path to ground the electrical noise. The final ECG circuit and novel electrode were used to detect real human cardiac signals from a subject who was tested while standing still and walking. The signals obtained from the two activities were nicely shaped, without any motion artifact noise. We took electrode size into account in this study because the impedance depended on the area of the electrode. An electrode of 50 mm diameter showed the best curve for the ECG signal without any electrical noise.

수중 무선 전화기의 설계 - 수중무선전화기 설계를 위한 수중소음분석을 중심으로- (The Design of Wireless Underwater Telephone -Analysis of Underwater Background Noise for Wireless Underwater Telephone Design -)

  • 박문갑;윤갑동;김석제;윤종락
    • 수산해양기술연구
    • /
    • 제37권4호
    • /
    • pp.302-307
    • /
    • 2001
  • 본 연구는 잠수기 어업용 수중무선전화기를 설계하는데 있어 최적의 반송 주파수와 송신 신호의 음원 준위를 결정할 목적으로 우리 나라 잠수기 주 조업장의 하나인 거제와 통영 해역의 해양 배경소음과 조업중인 잠수기 어장의 수중 소음에 대하여 검토, 고찰한 결과를 요약하면 다음과 같다. 1. 거제와 통영의 잠수기 어장의 해양 배경 소음을 분석한 결과, 음압 준위는 25∼301kHz 부근에서 가장 낮아 52∼57dB이었고, 주변 통항 선박량과 산업시설이 많은 거제 해역이 통영 해역보다 약 5dB 더 높았다. 2. 거제와 통영의 잠수기 어선의 조업중의 수중소음을 비교하면, 최저 음압준위는 30kHz 부근에서 거제 어장에서는 67dB로서 통영의 62d묘보다 5dB 높은 음압 준위를 나타냈다. 이것은 거제 해역은 잠수기 어선의 규모도 통영 해역의 잠수기 어선보다 약간 크고, 분사기를 사용하여 작업하는데 비해 통영 해역은 잠수기 어선의 크기도 상대적으로 작고, 주 어획 대상물이 달라 분사기를 사용하지 않는 것이 그 원인으로 판단된다. 3. 거제 해역의 패류 채취용 분사기를 사용할 때의 수중 소음의 음압 준위는 102dB었다. 4. 거제 해역의 조업중에 대한 수중 배경 소음을 67dB라 가정할 때, 최대 500m까지 통화하기 위한 송신 신호의 음원 준위는 131dB 정도이다. 그러나, 통영 해역의 잠수기 조업은 분사기를 사용하지 않는 조업으로 이 경우 배경 소음은 약 62dB로서 송신 신호의 음원 준위는 126dB정도이다. 잠수기 조업중이 아닌 경우 즉, 스쿠버 다이버용 수중무선 전화기인 경우에는 배경 소음이 52∼57dB이므로 송신 신호의 음원 준위는 l16∼121dB이면 될 것으로 판단된다. 협동학습 모형이 수학 수업에 보다 발전적으로 널리 적용되기를 기대한다.cal results well visualized the streamlines, pressure fields, and speed vectors of a simple cambered and slot cambered otter board with slot size 0.02C. The slot cambered one with slot size 0.02C was shown that pressure field was distributed moderately on front and back side of otter board. And, the delay and decrease of separation were favorably achieved by flow through slot. 4. Computed result on the pattern of hydrodynamic field and the values of C/sub L/ and C/sub D/ by the commercial CFD code, FLUENT, show almost the same as those of the experimental result.erence was found in its fragrance. And, no difference was found in brightness and viscosity between samples. As a result of conducting the palatability test, no difference was showed in the appearance, but as for the overall palatability

  • PDF

농경지 관측을 위한 KOMPSAT 대기보정 적용 및 평가 (Application of Atmospheric Correction to KOMPSAT for Agriculture Monitoring)

  • 안호용;류재현;나상일;소규호;이경도
    • 대한원격탐사학회지
    • /
    • 제37권6_3호
    • /
    • pp.1951-1963
    • /
    • 2021
  • 농업환경 모니터링에서 지구관측위성을 활용한 원격탐사 자료는 시·공간적 그리고 효율성 측면에서 다른 방법에 비해 많은 이점을 가진다. 위성에 탑재된 센서는 태양광이 지표면에 반사되어 들어오는 에너지를 측정하므로, 지구의 대기에 의해 산란·흡수·반사되는 과정에서 잡음이 발생한다. 따라서 지표면에 반사되는 에너지(복사휘도)를 정확히 측정하기 위해서는 대기의 효과에 의한 잡음을 제거해야하는 대기보정이 선행되어야 한다. 본 연구는 KOMPSAT-3 위성의 대기보정 적용 및 농업분야 활용성 평가를 위해 대기보정 민감도 분석, 위성 상호간 교차 분석, 지상관측자료와 비교 분석을 수행하였다. 그 결과 모든 경우에서 대기보정 후 표면 반사율이 대기보정 전 TOA 반사율 보다 상호 일치율이 높게 나타났으며 동일한 기준의 시계열 식생지수 생산이 가능할 것으로 판단된다. 하지만 대기입력 파라미터의 민감도 및 위성촬영각(Tilt)에 대한 정량적인 분석을 위한 추가 연구가 필요하다.

일본에서 도래하는 전파간섭의 측정에 관한 연구 (A Study on the measurement of Radio Frequency Interference by the Waves from Noise Source in Japan)

  • 배대환;정인성;배재영;김동일
    • 한국항해학회지
    • /
    • 제25권2호
    • /
    • pp.119-129
    • /
    • 2001
  • 전파통신의 수요의 증가 및 통신시스템의 발달과 더불어, 인접 국가간의 전파간섭은 중요한 문제로 부각되고 있다. 이러한 문제는 외교적으로 미묘한 것이므로 명확한 기술적 근거를 가지고 대처해야 한다. 우리나라의 경우, 일본 후쿠오카에 위치한 기지국에 의해 남해안 TRS 서비스에 전파간섭이 발생한 후, 인접국가간의 전파간섭 문제가 중요하게 부각되었다. 따라서, 본 논문에서는 일본 후쿠오카에서 한국 부산으로 유입되는 전파를 실시간으로 측정하였다.

  • PDF