• Title/Summary/Keyword: BTX-A

Search Result 91, Processing Time 0.019 seconds

Measurement of Atmospheric BTX in Seoul Using Differential Optical Absorption Spectroscopy (차등흡수 분광법을 이용한 서울 대기 중 BTX 측정)

  • Lee Chulkyu;Choi Yeo Jin;Lee Jeong Soon;Jung Jin Sang;Kim Young Joon;Kim Ki Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.1-14
    • /
    • 2005
  • In this study, a Long Path Differential Optical Absorption Spectroscopy system (K-JIST LP-DOAS) has been used to simultaneously measure atmospheric monoaromatic hydrocarbons and other trace compounds. The validity of the K-JIST LP-DOAS for measuring atmospheric monoaromatic hydrocarbons was tested during a field campaign between 12 February and 14 March 2003 at an urban site in Seoul, Korea through inter-comparative measurements against a collocated on-line Gas Chromatography (GC) system. The concentrations of benzene, toluene, p-xylene, and m-xylene were measured with the K-JIST LP-DOAS system in the UV region (239~302 nm) over a 740 m beam path. For the other trace compounds, a longer spectral range (299~362 nm) was used. In order to remove the interference of atmospheric abundant species (such as oxygen, sulfur dioxide and ozone), two oxygen optical density spectra obtained at two pathlengths, 697 and 1133m, and reference spectra of sulfur dioxide and ozone were incorporated in the fitting procedure. The mean concentrations measured by our LP-DOAS during the measurement period were 0.77 ($\pm$0.38) ppbv for benzene, 3.68 ($\pm$1.90) ppbv for toluene, 0.41 ($\pm$0.19) ppbv for p-xylene, 0.54 ($\pm$0.24) ppbv for m-xylene. The concentration data of benzene, toluene, p-xylene and m-xylene obtained by our LP-DOAS were found to be in relatively good correlations with those of the online GC system. Pearson's coefficients in the observed concentrations between LP-DOAS and on-line GC were 0.84 for benzene, 0.83 for toluene and 0.65 for m,p-xylene. This study suggests that the LP-DOAS system can be used to provide reliable information on both the mixing ratios and temporal distribution characteristics of monoaromatic hydrocarbons in the urban air.

Risk Analysis of Transporting Hazardous Substances in Harbor Using Modeling Program (항만에서 위험물 운송 중 유해화학물질 누출 위험성에 관한 연구)

  • Yoon, Sukyoung;Yun, Jayeon;Han, Jiyun;Jung, Seungho
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.272-278
    • /
    • 2018
  • Recently, the use of hazardous chemicals has been continuously increasing. Therefore, the international trade volume is growing and chemical accidents have increased. Nowadays, the safety awareness of the public has increased. As a result, the management and supervision of hazardous chemicals have been strengthened. However, the port policy of Korea has focused on increasing the volume of cargo through facility development. Thus, the port management of hazardous chemicals has been relatively neglected. For national economic growth and society, the port management of hazardous chemicals should be considered to efficiently ensure safety and economic growth. Therefore, this study assumed scenarios where hazardous materials were moved in a dangerous container, not only on appropriate wharfs but also in ports that were close to a big city. The BTX substances were selected among the toxic chemicals with large import and export volumes, and the risk distance and damage effects were predicted using various risk assessment programs. It is expected that this could be used to improve a port safety management system and could be utilized to determine the safety distance in case of an accident.

Complete Oxidation of Volatile Organic Compounds(BTX) over the Supported Transition Metal Catalysts (전이금속 담지 촉매상에서 휘발성유기화합물(BTX)의 완전산화)

  • Kim, Sang-Chai;Seo, Seong-Gyu;Yu, Eui-Yeon
    • Clean Technology
    • /
    • v.6 no.1
    • /
    • pp.17-25
    • /
    • 2000
  • Catalytic oxidation of volatile organic compounds(benzene, toluene, xylene) over transition metals/ALO-6 catalysts was investigated in a fixed bed flow reactor system at atmospheric pressure. The orders of catalytic activities for the complete oxidation of toluene were Cu>Mn>Fe>V>Mo>Co>Ni>Zn for 15% transition metals/ALO-6 catalyst system. Increasing the calcination temperature resulted in decreasing the specific surface areas of catalyst, subsequently the catalytic activity. The loading of Cu on ALO-6 had a great effect on the catalytic activity and 5% Cu/ALO-6 catalyst showed higher catalytic activity, which may be contributed to the uniformly distributed active sites. Benzene, toluene and xylene were completely oxidized to carbon dioxide over 5% Cu/ALO-6 catalyst at over $380^{\circ}C$ and 4.5 g-cat.hr./g-mole. The orders of the kinds of reactants for catalytic activity over 5% Cu/ALO-6 were toluene>xylene>benzene. As the concentration of reactant increased, the catalytic activity decreased due to self-poison of reactant.

  • PDF

An anatomic study of depressor anguli oris muscle and the mentalis muscle in the lower face (임상가를 위한 특집 2 - 아래얼굴부위 근육의 해부학)

  • Hur, Mi-Sun;Lee, Kyu-Seok;Kim, Hee-Jin
    • The Journal of the Korean dental association
    • /
    • v.50 no.10
    • /
    • pp.620-623
    • /
    • 2012
  • The use of botulinum toxin type A in the lower face has increasingly popular. And treatment of the depressor anguli oris muscle(DAO) and the mentalis muscle(MT), particularly in combination with filler substances, produces a remarkable improvement in the lower aged face. The aim of this study was to demonstrate the topographical anatomy of the DAO, MT, and their related structures, thereby providing critical information for determining the safest and most effective site for BTX-A injections. The most effective injection sites of DAO and MT were suggested based on the new anatomical knowledge of the lower face.

Design of Thermally Coupled Distillation Process Utilizing Existing Columns (기존 증류탑을 이용한 열복합 증류공정의 설계)

  • Lee, Moon Yong;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.1017-1022
    • /
    • 2008
  • Though many divided wall columns are implemented in field as energy-efficient distillation columns, its application is limited due to the difficulty of building a new column. A novel energy-efficient distillation system utilizing the existing columns is proposed here. The proposed can reduce the energy consumption by about 39% comparing with the existing system. And it is shown that the proposed improves the column operability over the existing. The tray numbers of the added columns have no significant influence on the composition of a side draw.

Concentration level of Volitile Organic Compounds about the Air of Source Boundary Site in Seongseo Industrial Complex (대구성서산업단지 발생원부지경계 대기 중 휘발성유기화합물질의 농도수준)

  • An Sang-Young;Choi Sung-Woo
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2005
  • The concentrations of volatile organic compounds(VOCs) in the ambient air were measured at various point(Source, source boundary) in Seongseo industrial complex during May to November 2003. Air samples were collected in Silcocan canister $(1{\ell},\;6{\ell})$ and analyzed using a cryogenic preconcentration system and GC/MSD. We identified 37 species by the US EPA(TO-14 method). The result showed a variety distribution of the con­centration, Higher concentrations of BTX, Styrene, 1,3,5-Trimethylbenzene, 1,2,4-Trimethylbenzene were observed at the sampling sites. They seemed to be emitted from the facility of wastewater treatment, reaction tank of chemistry factory and facility of Tenter. The concentrations of VOCs contents in Seongseo industrial complex were generally higher than those in Yeosu complex and Ulsan complex, although those were similar in Sihwa­Banwol complex.

Inclusion Selectivity of the Cyanocadmate Host Complex with Piperazine Ligand for Aromatic Guest Molecules; Benzene, Toluene, Ethylbenzene and Xylene Isomers (Piperazine 리간드를 가진 시아노카드뮴 호스트 착물의 방향족 게스트 분자에 대한 포접선택성)

  • Kim, Chong-Hyeak;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.333-338
    • /
    • 2003
  • Inclusion selectivity of a three-dimensional piperazine-ligated cyanocadmate host complex, $[Cd_x(CN)_{2x}\{HN(CH_2CH_2)_2NH\}_y]{\cdot}zG$, has been investigated for benzene (B), toluene (T), ethylbenzene (E), o- (O), m- (M), and p-xylene (P) isomers as the aromatic guest molecules. From the binary, ternary and quarternary guest mixtures of E and xylene isomer (X), the order of inclusion selectivity in the host complex is O>E>P>M. From the binary to quinary BTX mixtures, the order of preference in the complex is seen to be B>T>O${\gg}$P>M.

A Study on Validation for Mapping of Gas Detectors at a BTX Plant (BTX 공정에서 Gas Detector Mapping 적정성 검토에 관한 연구)

  • Seo, Ji Hye;Han, Man Hyoeng;Kim, Il Kwon;Chon, Young Woo
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.168-178
    • /
    • 2017
  • In order to prevent major and chemical accidents, some of the plants which would like to install and operate hazard chemicals handling facilities must submit Off-site Consequence Analysis due to recent arisen leak accidents since 2015. A lot of chemical industrials choose gas detectors as mitigation equipment to early detect gas vapor. The way of placement of gas detectors has two methods; Code-based Design(CBD) and Performance-based Design. The CBD has principles for gas detectors to be installed with consideration for the place that is expected to accumulate gas, and the leak locations according to legal standards and technical guidelines, and has a possibility to be unable to detect by these rules to locate gas detectors by vapor density information. The PBD has two methods; a Geographic Method and Scenario based Method. The Scenario-based Method has been suggested to make up for the Geographic Coverage Method. This Scenario-based Method draw the best optimum placement of gas detectors by considering leak locations, leak speed information, leak directions and etc. However, the domestic placement guidelines just refers to the CBD. Therefore, this study is to compare existing placement location of gas detectors by the domestic CBD with placement locations, coverages and the number of gas detectors in accordance with the Scenario-based Method. Also this study has measures for early detecting interest of Vapor Cloud and suitable placement of gas detectors to prevent chemical accidents. The Phast software was selected to simulate vapor cloud dispersion to predict the consequence. There are two cases; an accident hole size of leak(8 mm) from API which is the highst accident hole size less than 24.5 mm, and a normal leak hole size from KOSHA Guide (1.8 mm). Detect3D was also selected to locate gas detectors efficiently and compare CBD results and PBD results. Currently, domestic methods of gas detectors do not consider any risk, but just depend on domestic code methods which lead to placement of gas detectors not to make personnels recognize tolerable or intolerable risks. The results of the Scenario-based Method, however, analyze the leak estimated range by simulating leak dispersion, and then it is able to tell tolerable risks. Thus it is considered that individuals will be able to place gas detectors reasonably by making objectives and roles flexibly according to situations in a specific plant.

The Influence of Botulinum Toxin Type A Masticatory Efficiency (보툴리눔 A형 독소가 저작효율에 미치는 영향)

  • Park, Hyung-Uk;Kwon, Jeong-Seung;Kim, Seong Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.53-67
    • /
    • 2013
  • This study was aimed to evaluate the masticatory efficiency after botulinum toxin type A (BTX-A) injection during 12 weeks using objective and subjective test. Also, we compared the difference of masticatory efficiency between group that injected into the masseter muscle only (M-group) and group that injected into the masseter and temporalis muscle (M-T group). The mixing ability index (MAI) was used as the objective indicator, and visual analogue scale (VAS) and food intake ability (FIA) index were used as the subjective indicators. It was concluded that masticatory efficiency was significantly lowered after a BTX-A injection into the masticatory muscle, but it gradually recovered in a predictable pattern by the 12 weeks. The disturbance of subjective masticatory efficiency was lasted longer than objective masticatory efficiency. The masticatory efficiency was lower in M-T group than M group. It was statistically significant in the VAS and FIA at 4 weeks, but the MAI showed no significancy. After 4weeks, there was rapid recovery of muscle function in M-T group, and the difference between two groups was not significant. It could be concluded that there will be no serious disturbance of mastication compared to injection is done only into the masseter muscle, even if injection is done into the masseter and temporalis muscle in dose of this study. According to the food properties, it was confirmed that people feel more discomfort on taking hard and tough foods after BTX-A injection and not only hard foods, but also intake of soft and runny foods were influenced by botulinum toxin injection.

A Study on Drying and Carbonization of Organic Sludge from Sewage Plant and Petrochemical Industries for Energy and Resources Recovery (하수슬러지 및 석유화학산업단지 폐수슬러지의 에너지화와 재활용을 위한 건조 및 탄화에 관한 연구)

  • Jun, Kwan-Soo;Hwang, Eung-Ju;Kim, Hyung-Jin
    • Clean Technology
    • /
    • v.15 no.3
    • /
    • pp.154-164
    • /
    • 2009
  • In 2007, 94% of organic wastewater sludge from industries located in Ulsan was disposed of by ocean dump. The ocean dump of organic sludge would be totally prohibited by the year of 2012. However, there is no alternative but incinerating the sludge from the industries located in Ulsan. Securing the technology for sludge treatment and on-land disposal is very important issue among the industries in the Ulsan Petrochemical Industry Complex. In this study, the material aspects of dried and carbonized sludge as a fuel were evaluated for petrochemical and sewage sludge from Ulsan. The dried and carbonized sludges from the factories producing terephthalic acid, BTX, propylene, chemical textile, etc. of which the low heat value exceeded 3,000 kcal/kg had high potential as a fuel according to the results of thermal characteristic analysis. However, the dried sludges with heat values lower than 2,100 kcal/kg and carbonized sludges, lower than 1,100 kcal/kg containing more Inorganic material from the industries producing pulp, paper, methylamine, amide, etc. had a little potential to be used as a fuel. In most cases, drying the sludge showed better results than carbonization in the aspect of thermal characteristics of sludge.