• Title/Summary/Keyword: BRIDGE 3.0

Search Result 523, Processing Time 0.03 seconds

PWM Inverter System Control for Flywheel Energy Storage System using PDFF(Pseudo-Derivative Control with Feedforward Gain) Algorithm (PDFF 기법을 적용한 플라이휠 에너지 저장장치용 PWM 인버터 시스템 제어)

  • Park, Jong-Chan;Jeong, Byung-Hwan;Choi, Hee-Ryong;Choe, Gyu-Ha
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • This paper presents about energy input and output modeling for a flywheel energy storage system that can store and supply mechanical energy, which is emerging as one of clean energy sources, and the analysis and control of a PWM inverter system. Moreover, this paper describes flywheel's characteristics related to variations of mechanical and electrical parameters like as voltage and current versus speed characteristics formed as numerical formula and thus simulate behaviour-status of flywheel energy. Also for comparison and analysis between PI control and PDFF control, the modeling, design and analysis to the single-phase full bridge inverter with double loop feedback control is accomplished through numerical description and simulation. Finally, under load condition 0.1[pu], 1[pu]. it is validated that harmonic characteristics for voltage and current wave is controlled within 5% below even dynamics condition.

Corroded and loosened bolt detection of steel bolted joints based on improved you only look once network and line segment detector

  • Youhao Ni;Jianxiao Mao;Hao Wang;Yuguang Fu;Zhuo Xi
    • Smart Structures and Systems
    • /
    • v.32 no.1
    • /
    • pp.23-35
    • /
    • 2023
  • Steel bolted joint is an important part of steel structure, and its damage directly affects the bearing capacity and durability of steel structure. Currently, the existing research mainly focuses on the identification of corroded bolts and corroded bolts respectively, and there are few studies on multiple states. A detection framework of corroded and loosened bolts is proposed in this study, and the innovations can be summarized as follows: (i) Vision Transformer (ViT) is introduced to replace the third and fourth C3 module of you-only-look-once version 5s (YOLOv5s) algorithm, which increases the attention weights of feature channels and the feature extraction capability. (ii) Three states of the steel bolts are considered, including corroded bolt, bolt missing and clean bolt. (iii) Line segment detector (LSD) is introduced for bolt rotation angle calculation, which realizes bolt looseness detection. The improved YOLOv5s model was validated on the dataset, and the mean average precision (mAP) was increased from 0.902 to 0.952. In terms of a lab-scale joint, the performance of the LSD algorithm and the Hough transform was compared from different perspective angles. The error value of bolt loosening angle of the LSD algorithm is controlled within 1.09%, less than 8.91% of the Hough transform. Furthermore, the proposed framework was applied to fullscale joints of a steel bridge in China. Synthetic images of loosened bolts were successfully identified and the multiple states were well detected. Therefore, the proposed framework can be alternative of monitoring steel bolted joints for management department.

Cryoscopy of Amine-Polytungstates (다중텅그스텐산 아민염의 분자량 측정)

  • Pyun, Chong-Hong;Sohn, Youn-Soo
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.2
    • /
    • pp.126-131
    • /
    • 1974
  • Trioctylamine-and tricaprylylmethylammonium chloride-tungstate salts have been prepared by solvent extraction from the sodium tungstate solution of various acidities(pH = 2, 4, 6). The molecular weights of the amine-tungstate salts thus obtained could be cryoscopically measured in benzene by means of a home-built Wheatstone bridge utilizing thermistor with sensitivity of 1/$4000^{\circ}C$. The cryoscopic data along with the results of chemical analysis and infrared spectra of the salts indicate that the amine-tungstates prepared at pH = 2 and 4 are all metatungstate whereas the salt obtained at pH = 6 is an unknown form quite different from the expected paratungstate.R = 0.14. By hydrogen bonding a guanidyl nitrogen of a sulfaguanidine molecule is linked to the sulfonyl oxygens of the other molecules indirectly through two different water molecules. The role of water molecule is both a .nor and an acceptor in hydrogen-bonding formation and these hydrogen bonds are tetrahedrally o?ented. The hydrogen-bonding networks form infinite molecular layers parallel to (001) plane.

  • PDF

Outcomes of Coronary Artery Bypass Grafting after Extracorporeal Life Support in Patients with Cardiac Arrest or Cardiogenic Shock

  • Kim, Younghwan;Cho, Yang-Hyun;Yang, Ji-Hyuk;Sung, Kiick;Lee, Young Tak;Kim, Wook Sung;Lee, Heemoon;Cho, Su Hyun
    • Journal of Chest Surgery
    • /
    • v.52 no.2
    • /
    • pp.70-77
    • /
    • 2019
  • Background: Extracorporeal life support (ECLS) is used as a bridge to revascularization in high-risk patients with ischemic heart disease. We reviewed our experiences of coronary artery bypass grafting (CABG) after ECLS in patients with cardiac arrest or refractory cardiogenic shock. Methods: We retrospectively reviewed 4,616 patients who underwent CABG at our institution between May 2006 and February 2017. We identified patients who underwent CABG following ECLS for cardiogenic shock or cardiac arrest. Twenty-three patients (0.5% of all CABG cases) were enrolled in the analysis. Their median age was 65 years (Q1-Q3, 58-77 years). Nine patients (39.1%) were diagnosed with ST-elevation myocardial infarction. Mechanical complications after acute myocardial infarction, including acute mitral regurgitation, left ventricular rupture, and ventricular septal defect, occurred in 9 patients (39.1%). Results: The median time from cardiopulmonary resuscitation to ECLS initiation was 25 minutes (Q1-Q3, 18.5-28.5 minutes). Conventional CABG was performed in 10 patients (43.5%) who underwent concomitant intracardiac procedures. Postoperative ECLS was required in 16 patients (69.5%). The rate of successful ECLS weaning was 91.3% (n=21). There were 6 early mortalities (26.1%). Conclusion: CABG after ECLS was very rare in real-world circumstances. Although the early mortality rate was high, the risk of mortality may be acceptable under such devastating circumstances.

Design and Fabrication of the 0.1${\mu}{\textrm}{m}$ Г-Shaped Gate PHEMT`s for Millimeter-Waves

  • Lee, Seong-Dae;Kim, Sung-Chan;Lee, Bok-Hyoung;Sul, Woo-Suk;Lim, Byeong-Ok;Dan-An;Yoon, yong-soon;kim, Sam-Dong;Shin, Dong-Hoon;Rhee, Jin-koo
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.73-77
    • /
    • 2001
  • We studied the fabrication of GaAs-based pseudomorphic high electron mobility transistors(PHEMT`s) for the purpose of millimeter- wave applications. To fabricate the high performance GaAs-based PHEMT`s, we performed the simulation to analyze the designed epitaxial-structures. Each unit processes, such as 0.1 m$\mu$$\Gamma$-gate lithography, silicon nitride passivation and air-bridge process were developed to achieve high performance device characteristics. The DC characteristics of the PHEMT`s were measured at a 70 $\mu$m unit gate width of 2 gate fingers, and showed a good pinch-off property ($V_p$= -1.75 V) and a drain-source saturation current density ($I_{dss}$) of 450 mA/mm. Maximum extrinsic transconductance $(g_m)$ was 363.6 mS/mm at $V_{gs}$ = -0.7 V, $V_{ds}$ = 1.5 V, and $I_{ds}$ =0.5 $I_{dss}$. The RF measurements were performed in the frequency range of 1.0~50 GHz. For this measurement, the drain and gate voltage were 1.5 V and -0.7 V, respectively. At 50 GHz, 9.2 dB of maximum stable gain (MSG) and 3.2 dB of $S_{21}$ gain were obtained, respectively. A current gain cut-off frequency $(f_T)$ of 106 GHz and a maximum frequency of oscillation $(f_{max})$ of 160 GHz were achieved from the fabricated PHEMT\\`s of 0.1 m$\mu$ gate length.h.

  • PDF

The Characteristics and the Effects of Pollutant Loadings from Nonpoint Sources on Water Quality in Suyeong Bay (수영만 수질에 미치는 비점원 오염부하의 특성과 영향)

  • CHO Eun Il;LEE Suk Mo;PARK Chung-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.279-293
    • /
    • 1995
  • The most obvious and easily recognizable sources of potential water pollution are point sources such as domestic and industrial wastes. But recently, the potential effects of nonpoint sources on water quality have been increased apparently. In order to evaluate the characteristics and the effects of nonpoint sources on water quality, this study was performed in Suyeong Bay from May, 1992 to July, 1992. The depth-averaged 2-dimensional numerical model, which consists of the hydrodynamic model and the diffusion model was applied to simulate the water quality in Suyeong Bay. When flowrate was $65.736m^3/s,$ the concentration of pollutants (COD, TSS and VSS) at Oncheon stream (Sebeong bridge) during second flush were very high as much as 121.4mg/l of COD, 1148.0mg/l of TSS and 262.0mg/1 of VSS. When flowrate was 4.686m^3/s, the concentration of pollutants $(TIN,\;NH_4\;^+-\;N,\;NO_2\;^--N\;and\;PO_4\;^{3-}-P)$ during the first flush were very high as much as 20.306mg/1 of TIN, 14.154mg/1 of $NH_4\;^+-N$, 9.571mg/l of $NO_2\;^--N$ and l.785mg/l of $PO_2\;^{3-}-P$ As results of the hydrodynamic model simulation, the computed maximum velocity of tidal currents in Suyeong Bay was 0.3m/s and their direction was clockwise flow for ebb tide and counter clockwise flow for Hood tide. Four different methods were applied for the diffusion simulation in Suyeong Bay. There were the effects for the water quality due to point loads, annual nonpoint loads and nonpoint loads during the wet weather and the investigation period, respectively. The efforts of annual nonpoint loads and nonpoint loads during the wet weather seem to be slightly deteriorated in comparison with the effects of point loads. However, the bay was significantly polluted by the nonpoint loads during the investigation period. In this case, COD and SS concentrations ranged 2.0-30.0mg/l, 7.0- 200.0mg/l in ebb tide, respectively. From these results, it can be emphasized that the large amount of pollutants caused by nonpoint sources during the wet weather were discharged into the bay, and affected significantly to both the water quality and the marine ecosystem. Therefore, it is necessary to consider the loadings of nonpoint pollutants to plan wastewater treatment plant.

  • PDF

The Characteristic of Strength for a Lime Stone in Donghae Area and Harden Cement Milk of Super Injection Grouting (동해 석회암과 SIG 고결체의 강도특성)

  • Park, Young-Ho;Kim, Nak-Young;Hong, Sa-Myun;Yook, Jeong-Hoon;Kim, Ki-Seog
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.137-145
    • /
    • 2004
  • Limestone zone in korea have been distributed to diagonal line so that it is wide from the Gangwondo to the Jeonlanamdo. The limestone cavity and fractured zone were formed by chemical weathering. Limestone cavity and fractured zone was reinforced with cemented milk(w/c=60%)by high pressure jet grouting by tripple -pipe to establish bridge foundation on the ground condition like limestone cavity. To analyze property of limestone and solid of cement milk(w/c=65%), mixed solid of cement, core NX size in the limestone cavity and fractured zone and compressive strength. Seismic tomograpy exploration was pcrforn1cd to analyze deformation modulus of limestone. The analysis suggests that deformation modulus of limestone has effect on uniaxial compressive strength, seismic velocity, seismic elasticity modulus. Average static elasticity modulus of limestone is $5.08{\times}10^5kgf/cm^2$, cement and coal mixed solid is $0.25{\times}10^5kgf/cm^2$, $0.095{\times}10^5kgf/cm^2$. Average seismic velocity of limestone is 5.240m/sec, cement and coal mixed solid is 2,211.3m/sec, 1,447.5m/sec. Average uniaxial compressive strength of limestone was $1,221.3kgf/cm^2$ and limestone specimen mixed with cement milk and solid of cement milk mixed with coal were $125.22kgf/cm^2$, $35kgf/cm^2$ each other. Average friction angle of limestone was $49.14^{\circ}$ and limestone specimen mixed with cement milk and solid of cement milk mixed with coal were $38.39^{\circ}, 25.83^{\circ}$ each other. Average cohesion of limestone was $137.7kgf/cm^2$ and limestone specimen mixed with cement milk and solid of cement milk mixed with coal were $23.5kgf/cm^2$, $15.5kgf/cm^2$ each other. Average deformation modulus of limestone was $2.84{\times}10^5kgf/cm^2$ and limestone specimen mixed with cement milk and solid of cement milk mixed with coal were $0.4{\times}10^5kgf/cm^2, 0.12{\times}10^5kgf/cm^2$ each other. It was analyzed that the elasticity and uniaxial compressive strength, seismic velocity of solid of cement milk mixed limestone pieces and coal had an highly interrelation regardless of existence of limestones pieces and coal but it had shown that limestones had an lower interrelation. In case of field seismic velocity and deformation of limestone, SIC solid of cement milk mixed with coal and limestone pieces had an highly interrelation.

  • PDF

An improvement plan of Curriculum in Departments of Dental Technology (치기공과 교육과정의 개선방안)

  • Bae, Bong-Jin;Lee, Hwa-Sik;Park, Myung-Ho
    • Journal of Technologic Dentistry
    • /
    • v.31 no.4
    • /
    • pp.55-66
    • /
    • 2009
  • This research collected the curriculum for Dental Technology from a total of 20 schools --3-year colleges and 4-year colleges-- all in Korea. And we analyzed the average credits of subjects from students. As a result of this analysis, we get the conclusion below: 1. In the arithmetic mean of the major basis subjects which graduates and undergraduates answered about each subjects; Seminar, Dental morphology I II, Dental morphology practice I II, and Dental devices & instruments don't have many credits. And averages of the major application subjects credits which are Implants(especially low), Occlusal anatomy practice I II, Dental ceramics practice I II, and Dental ceramics practice are low, mostly have a converged tendency in high points. 2. In an analysis of the correlation which is based on the major basis subjects: Dental esthetic, oral anatomy I II, Dental materal practice III, Dental casting pracedure, Oral hygiene, Health & medical law, Management administration, and Medical terminology have a meaningful difference. (${\rho}$ < 0.05) 3. In an analysis of the correlation which is based on the major application subjects; Crown and bridge prosthodontics practice IV, Complete denture prosthodontics I II III, Complete denture prosthodontics practice I II III, Dental ceramics I II, Dental ceramics practice I II, Dental ceramics practice IIII, Occlusal anatomy I II, Occlusal anatomy practice I, Operative dentistry laboratory technology I, Operative dentistry laboratory technology practice II, Dental attachment laboratory technology practice, Implants, and Dental laboratory clinical practice have meaningful difference. (${\rho}$ < 0.05) 4. In an analysis of the correlation which is based on the ratio of a theory to an actual training; 40:60(38.57%) is the highest, followed by 30:70(30.04%), 50:50(23.32%), 60:40(5.83%), and 70:30(2.24%). These have meaningful difference. (${\rho}$ < 0.05) 5. In an analysis of the correlation which is based on the distinction of sex: Partial denture prosthodontics practice I II III, Complete denture prosthodontics I II III, Complete denture prosthodontics practice I II III, Occlusal anatomy practice I II, Implants, Medical terminology have meaningful difference. (${\rho}$ < 0.05) For the purpose of training entrepreneurs of middle standing who is required by a future society, Department of Dental Technology's Curriculum need to be managed with planning a curriculum which reflects opinions of graduates, undergraduates and a society, and also are considered not focusing on a supplier but focusing on a user.

  • PDF

Practical Aspects of Microwave Surface Velocity Meter Applied to Measurements of Stream Discharges (전자파 표면 유속계의 하천 유량 측정에 관한 실용성)

  • Lee, Sang-Ho;Kim, U-Gu;Kim, Yeong-Seong
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.6
    • /
    • pp.671-678
    • /
    • 1997
  • Water surface velocity meters with microwave were applied to stream discharge measurements and its practical aspects were evaluted. The rating of the surface velocity meters was performed through a carriage and a water tank for the ship model test. It gave5.5% or less errors of average measured velocities under the vertical tilt ang1e of 20$^{\circ}$, 35$^{\circ}$, or 45$^{\circ}$ . A surface velocity meter was used to measure flood velocities at Yoju bridge from 8:00 a.m. to 10:00 a.m. on August 26, 1995. The results showed that surface velocities ranged from 2 to 4 m/s. With the measured surface velocities multiplied by 0.85, the discharge was computed as 10,500 m$^3$/s. It differed $\pm$2% or less from the value of a stage-discharge curve and that of an unsteady flow simulation. Although the measured data are used sparsely per 40 or 60 meters, the computed discharges do not give large variation. Stream discharge measurements were also performed under the normal condition without floods. With the known values of Taechong Dam releases. the depth averaging factors of velocity were calculated by 0.83~0.87. Although there are errors from wind action and inherent ones in the velocity meters, the research showed that surface velocity meters could be an simple and practical alternative for flood discharge measurements.

  • PDF

The study on the survival rates and crestal bone changes around the implants (임플란트 주위 골변화와 생존율에 대한 연구)

  • Choi, Hyun-Suk;Chung, Hyun-Ju;Kim, Ok-Su;Kim, Young-Jun
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.303-315
    • /
    • 2004
  • The success and failure of dental implants depends on various factors such as patient's systemic status, quantity and quality of surrounding bone, presence or absence of marginal infection and mechanical loading condition. The measurement of crestal bone changes around the implants is implemental to evaluate the success and long-term prognosis of the implant. This study was to evaluate the cumulative survival rate of the implants which had been placed in the Department of Periodontics, Chonnam National University Hospital between 1992 and 2003, and to observe the crestal bone loss around the implants which had at least 2 consecutive periapical radiographs after connecting the transmucosal abutment. The radiographs were scanned and digitalized, and the crestal bone levels on the mesial and distal surface of implants were measured using Image analyzer (Image Pro Plus, Media Cybernetics, USA), immediately after implant placement, at 2nd surgery, and 3 months, 6 months, 1 year, and every year thereafter. Any bone loss was not observed during the period between the 1stand 2nd surgery, and the bone loss was 0.86 ${\pm}$ 0.92 mm for the first year of loading after connecting the transmucosal abutment. After 1 year of loading, annual bone loss was 0.1 ${\pm}$ 0.27 mm, and total bone loss was 0.90 ${\pm}$ 0.80 mm (during the average follow-up periods of 22.5 ${\pm}$ 25.6 Mos), The implant, with smooth surface, in the mandible, and with the fixed bridge prosthesis showed greater bone loss, compared to those, with the rough surface, in the maxilla and with single crown. In systemically diseased patients (including DM or osteoporosis), the greater bone loss was observed. The cumulative survival rate among 432 implants was 94.10% for 7 years. Among 15 failed implants, 9 implants were removed due to mobility from disintegration of bone-implant interface. From this results, crestal bone loss around the implants were greatest during 1 year after transmucosal abutment connection, and various factors could affect peri-implant bone loss. To prevent and predict the bone loss around the implants and improve the prognosis, further comprehensive maintenance and follow-up schedules are required.