• 제목/요약/키워드: BPF Noise

검색결과 98건 처리시간 0.031초

A Low-Power 2.4 GHz CMOS RF Front-End with Temperature Compensation

  • Kwon, Yong-Il;Jung, Sang-Woon;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제7권3호
    • /
    • pp.103-108
    • /
    • 2007
  • In this paper, a low-power 2.4 GHz front-end for sensor network application (IEEE 802.15.4 LR-WPAN) is designed in a 0.18 um CMOS process. A power supply circuit with a novel temperature-compensation scheme is presented. The simulation and measurement results show that the front-end (LNA, Mixer) can achieve a voltage gain of 35.3 dB and a noise figure(NF) of 3.1 dB while consuming 5.04 mW (LNA: 2.16 mW, Mixer: 2.88 mW) of power at $27^{\circ}C$. The NF includes the loss of BALUN and BPF. The low-IF architecture is used. The voltage gain, noise figure and third-order intercept point (IIP3) variations over -45$^{\circ}C$ to 85$^{\circ}C$ are less than 0.2 dB, 0.25 dB and 1.5 dB, respectively.

청소기용 터보홴의 공력소음 발생에 관한 수치적 연구 (A Numerical Study on the Generation of Aeroacoustic Sound from Centrifugal Fans)

  • 전완호;김창준;류호선
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.69-75
    • /
    • 2001
  • A new method to calculate the aeroacoustic pressure of a centrifugal fan was developed The fan consists of an impeller, diffuser and circular casing. Due to the high rotating velocity and the small gap between the impeller and diffuser, the centrifugal fan makes very high noise level at BPF and its harmonic frequencies. The aeroacoustic pressure is calculated acoustic analogy In this paper, only dipole term is considered in the equation. The acoustics generated by moving impeller and stationary diffuser is calculated separately. The unsteady flow field data is calculated by the vortex method The predicted acoustic pressure agrees very well to the measured data. The difference of the two is smaller than 3dBA.

  • PDF

Band Pass Filter 를 활용한 전력 계통 PLL 제어기 설계에 관한 연구 (A Study on Power Grid PLL Controller Design Using Band Pass Filter)

  • 김문수;이병국
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2024년도 춘계학술발표대회
    • /
    • pp.455-456
    • /
    • 2024
  • 전력 계통의 Phase 를 제어하기 위해 산업에서 PLL(Phase Locked Loop)제어 시스템을 많이 사용한다. Phase 를 계산함에 있어 계통 전압에 왜곡 발생 시 PLL 을 통한 Phase 에 Noise 가 발생한다. 이를 줄이기 위해, 즉 특정 주파수 대역을 관찰하기 위해 BPF(Band Pass Filter)를 적용하여 PLL 제어기를 설계한 후, Filter 를 적용했을 때와 아닐 때의 위상 차 및 Noise 차이를 분석하여 어떤 경우가 성능적으로 우수한지 확인한다.

디젤 엔진에서의 터보 차저 Blow 소음 저감 위한 시뮬레이션 기반 공명기 위치 최적화 (Simulation-based Optimum Allocation of a Resonator for Reducing the Blow Noise of a Turbocharger in a Diesel Engine)

  • 강용헌;최동훈
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.129-134
    • /
    • 2010
  • A diesel engine is equipped with a turbocharger for providing more power at a low engine speed region by supplying charge air to combustion chambers. The turbocharger makes it possible to satisfy stringent emission regulations and customers' demand of enjoying the fun to drive by increasing engine performance. However, the turbocharger has the disadvantage of making BPF(Blade Passing Frequency), hissing, surge, whistle, and blow noises. Among them, reducing the blow noise, a narrow-band noise(a general range : 1800~2000Hz), is possible by using a resonator that controls the narrow frequency band governing the resonance in the intake system. In this study, the optimum location of the resonator is found by employing Boost as a CAE(Computer Aided Engineering) tool and is confirmed by experiments of an engine dynamo test and a real vehicle test.

원심홴의 설계 변수가 홴의 성능과 소음에 미치는 영향의 수치적 연구 (A Numerical Study of the Effects of Design Parameter upon Fan Performance and Noise)

  • 전완호;이덕주
    • 한국유체기계학회 논문집
    • /
    • 제2권3호
    • /
    • pp.45-51
    • /
    • 1999
  • Centrifugal fans are widely used and the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the casing. However, only a few researches have been carried out on predicting the noise due to the difficulty in obtaining detailed information about the flow field and casing effects on noise radiation. The objective of this study is to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan and to calculate the effects of rotating velocity, flow rate, cut-off distance and the number of blades and its effects on the noise of the fan. We assume that the impeller rotates with a constant angular velocity and the flow field around the impeller is incompressible and inviscid. So, a discrete vortex method (DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated with the unsteady Bernoulli equation. Lowson's method is used to predict the acoustic source. The cut-off distance is the most important factor effecting the noise generation. Acoustic pressure is proportional to 2.8, which shows the same scaling index as the experimental result. In this paper, the cut-off distance is found to be the dominant parameter offecting the acoustic pressure.

  • PDF

디지털 TRS 기지국의 RF 시스템 수신부를 위한 저잡음증폭기와 대역통과필터의 설계 및 제작 (Design and Implementation of LNA and BPF for RF System in Digital TRS Base Station (I) ; Receiving Part)

  • 구인모;이상설
    • 한국전자파학회논문지
    • /
    • 제10권6호
    • /
    • pp.900-909
    • /
    • 1999
  • 디지털 TRS 기지국 RF 시스템을 개발한다. 결정된 사양과 블걱도에 따라 기지국의 수신부 RF 회로를 설계한다. 고주파 대역통과필터 및 저잡음 증폭기, 자동 레벨 제어 감쇠기, 주파수 합성기 등의 주요 모듈을 설계/제작하고 , 이들 각 모듈의 연동을 주 기판을 설계/제작한다. 또한 수신부에서 중요한 고주파 신호의 스퓨리어스 잡음 및 시스템의 잡음을 억제할 수 있는 방안을 강구한다. 설계/제작된 RF 시스템의 각 구성 모듈 및 전체 수신부의 성능을 시험하여 설계 사양과 일치하는가를 확인한다.

  • PDF

청소기용 터보홴의 비정상 유동장 및 공력소음 해석 (An Analysis of the Unsteady Flow-Field and Aerodynamic Sound of a Turbo Fan used in a Vacuum Cleaner)

  • 전완호;김창준;류호선
    • 한국유체기계학회 논문집
    • /
    • 제5권2호
    • /
    • pp.36-42
    • /
    • 2002
  • A new method to calculate the aeroacoustic pressure of a centrifugal fan that is used in a vacuum cleaner has been developed. The centrifugal fan consists of the impeller, the diffuser, and the circular casing. Due to the high rotating speed of the impeller and the small gap distance between the impeller and diffuser, the centrifugal fan makes very high noise levels at BPF and its harmonic frequencies. In order to calculate the sound pressure of a centrifugal fan, the unsteady flow field data is needed. This unsteady flow field is calculated by the vortex method. The sound pressure is then calculated by acoustic analogy. In this paper, only dipole term is considered in the equation. The noise generated by moving impeller and stationary diffuser is calculated separately. The predicted acoustic pressures agree very well with the measured data. The difference between the two is less than 4dB

후드겸용 전자레인지 시로코홴의 유동 및 소음특성에 관한 연구 (A study on the flow and aeroacoustic characteristics of the sirocco fan of OTR (Over The Range))

  • 전완호;류호선;송성배;손상범
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.17-23
    • /
    • 2004
  • Aeroacoustic characteristics of sirocco fan used in Over-The-Range (OTR) has been analyzed in this paper. A microwave hood combination over the gas range is short for the OTR. The flow phenomena of the double-sided sirocco fan was analyzed numerically and experimentally by using commercial code and three dimensional PIV for flow visualization. Also, microphone array is used in order to understand acoustic characteristics of OTR. Two dimensional unsteady flow and acoustic simulation is tried to qualitatively estimate the effects of tonal noise and broadband noise on the overall sound pressure level. It is found that tonal sound is generated from the strong interaction between the impeller and cutoff while broadband sound is generated from the strong secondary flows along the scroll surface. To reduce the noise level, the V-shape cut-off was applied to improve the sound quality by reducing tonal noise. So the peak noise at BPF (Blade Passing Frequency) was almost reduced. The shape of flow-guide to suppress the secondary flow over the scroll surface was carefully checked. It is found that this affects flow pattern at the fan exit and reduces the broad band noise. Through this numerical and experimental study, the sound pressure level was lowered by 4dBA compared to that of the previous fan at the operating point.

저소음 청소기 개발 (Low Noise Vacuum Cleaner Design)

  • 주재만;이준화;홍승기;오장근;송화규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.939-942
    • /
    • 2007
  • Vacuum cleaner is a close life product that can remove various dusts from our surroundings. However well vacuum cleaner clean our environments, many people are looking away from it, due to its loud noise. Its noise causes a big trouble in the usual life, for example, catch calls, TV watching and discussing etc. To reduce these inconveniences, noise reduction methods and systematic design of low noise vacuum cleaner are studied in this paper. At first, sound quality investigation is performed to get the noise level and quality that make people TV watching and catch calls available. Based on the European and domestic customer SQ survey result, sound power, peak noise level and target sound spectrum guideline are studied and introduced. As a second, precise product sound spectrums are designed into each part based on the sound quality result. Fan-motor, brush, mainbody, cyclone spectrums are decided to get the final target sound based on the contribution level. Fan-motor is the major noise source of vacuum cleaner. Specially, its peak sound, RPM peak and BPF Peak, cause the people nervous. To reduce these peak sounds, high rotating impeller and diffuser are focused due to its interaction. A lot of experimental and numerical tests, operation points are investigated and optimization of flow path area between diffusers is performed. As a bagless device, cyclones are one of the major noise sources of vacuum cleaner. To reduce its noise, previous research is used and adopted well. Brush is the most difficult part to reduce noise. Its noise sources are all comes from aero-acoustic phenomena. Numerical analysis helps the understanding of flow structure and pattern, and a lot of experimental test are performed to reduce the noise. Gaps between the carpet and brush are optimized and flow paths are re-designed to lower the noise. Reduction is performed with keeping the cleaning efficiency and handling power together and much reduction of noise is acquired. With all above parts, main-body design is studied. To do a systematic design, configuration design developments technique is introduced from airplane design and evolved with each component design. As a first configuration, fan-motor installation position is investigated and 10 configuration ideas are developed and tested. As a second step, reduced size and compressed configuration candidates are tested and evaluated by a lot of major factor. Noise, power, mass production availability, size, flow path are evaluated together. If noise reduction configuration results in other performance degrade, the noise reduction configuration is ineffective. As a third configuration, cyclones are introduced and the size is reduced one more time and fourth, fifth, sixth, seventh configuration are evolved with size and design image with noise and other performance indexes. Finally we can get a overall much noise level reduction configuration. All above investigations are adopted into vacuum cleaner design and final customer satisfaction tests in Europe are performed. 1st grade sound quality and lowest noise level of bagless vacuum cleaner are achieved.

  • PDF

Reverse Engineering을 이용한 석션 하우징의 음장해석 (A Study on the Acoustic-Field Analysis of the Suction Housing using the Reverse Engineering)

  • 양정직;이동주
    • 한국생산제조학회지
    • /
    • 제20권4호
    • /
    • pp.464-471
    • /
    • 2011
  • We tried to analyze sound field of the interior of housing installed with an impeller using the Boundary Element Method (BEM) with the Kirchhoff-Helmholtz integral equation. In order to increase the accuracy of our analysis, reverse engineering technology, which has been developed in recent years. We measured and treated geometrical data with 3D scanning of the practical research object. After modeling by the reverse engineering, we analyzed variation of the BPF as adding vibration frequency and variation of the sound field of the interior of housing by changing the number of impeller blades. We also tried an analysis of free degree variation. Then, we proposed the analysis accuracy and noise reducing method by analysis result.