웨지가 있는 원심 임펠러의 유동 및 방사 음향장 해석(I) -유동장 및 소음원 해석- (An Analysis of the Flow Field and Radiation Acoustic Field of a Centrifugal Impeller with Wedge(I) -An Analysis of the Flow Field and Aeroacoustic Source-)

  • 이덕주;전완호
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1157-1164
    • /
    • 2001
  • Centrifugal fans are widely used and the noise generated by these machines causes one of the most serious problems. In general, the centrifugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the flow discharged from the impeller and the cutoff in the casing. However, only a few research have been carried out on predicting the noise because of the difficulty in obtaining detailed information about the flow field and casing effects on noise radiation. The objective of this study is to understand the generation mechanism of sound and to develop a prediction method for the unsteady flow field and the acoustic pressure field of a centrifugal fan. We assume that the impeller rotates with a constant angular velocity and the flow field of the impeller is incompressible and inviscid. So, a discrete vortex method(DVM) is used to model the centrifugal fan and to calculate the flow field. The force of each element on the blade is calculated by the unsteady Bernoulli equation. Lowsons method is used to predict the acoustic source. In order to compare the experimental data, a centrifugal impeller and wedge introduced by Weidemann are used in the numerical calculation and the results are compared with the experimental data. Reasonable results are obtained not only for the peak frequencies but also for the amplitudes of the tonal.

마이크로스트립 대역통과 여파기와 고이득 저잡음 증폭기를 이용한 블루투스 리시버 전반부 설계 (Design of Bluetooth Receiver Front-end using High Gain Low Noise Amplifier and Microstrip Bandpass Filter)

  • 손주호;최성열;윤창훈
    • 한국멀티미디어학회논문지
    • /
    • 제6권2호
    • /
    • pp.352-359
    • /
    • 2003
  • 본 논문에서는 마이크로스트립 대역통과 여 파기와 0.2$\mu\textrm{m}$ CMOS 공정을 이용한 저 잡음 증폭기를 이용하여 블루투스 리시버를 설계하였다. 설계한 저잠음 증폭기는 캐스코드 인버터를 이용하였으며, 레퍼런스 전압원을 가지며 쵸크 인덕터를 사용하지 않는 1단으로 설계하였다. 설계된 2.4GHz 저잡음 증폭기는 2.8dB의 NF값과 18dB의 전력이득을 가지고 있으며, 2.5V 공급 전원에서 255mW의 소모전력을 가지고 있다. 또한 마이크로스트립리시버 여파기는 중심주파수는 2.45GHz이고 대역폭은 4%이고 삽입손실은 -l.9dB를 가지고 있다. 마이크로스트립 대역통과 여과기와 저잡음 증폭기를 시뮬레이션 하였을 경우 16.3dB의 전력이득을 나타내 어 블루투스 대역에서 대역통과의 좋은 특성을 얻을 수 있었다.

  • PDF

DBS 수신을 위한 Dual Phase LNB 설계 (The Design of Dual Phase LNB for DBS Receiving)

  • 임윤두;고봉진
    • 한국항행학회논문지
    • /
    • 제6권3호
    • /
    • pp.188-194
    • /
    • 2002
  • DBS(Direct Broadcasting Satellite)는 광범위한 주사영역과 고품질의 서비스를 제공하므로 정보화 사회에서 매우 유용한 매체로 활용되고 있으며 이동체에서도 위성 방송을 수신할 수 있는 기술을 필요로 한다. 본 논문에서는 한반도 연근해를 항해구역으로 하는 선박과 육상 이동체에서 DBS 수신이 가능한 trracking antenna용 Dual phase LNB를 설계하였다. 설계한 Dual phase LNB는 저잡음 증폭기 대역통과 필터 발진기, 혼합기, 중간주파 증폭기로 구성하였고 위치 추적을 위해 각각 두 입 출력 위상을 동위상으로 구현하였다. 측정 결과, 11.7 GHz~12.2 GHz의 입력신호에 대하여 잡음지수는 0.87 dBmax, 변환이득 62 dB이고, 온도특성은 $-30^{\circ}C{\sim}60^{\circ}C$에서 ${\pm}400$ kHz이고 위상잡음은 100 kHz 옵셋에서 -101 dBc/Hz로서 우수한 성능을 나타내었다.

  • PDF

텔레비전 유휴 주파수 대역을 지원하는 저잡음 및 고선형 특성의 RF 수신기 설계 (TV White Space Low-noise and High-Linear RF Front-end Receiver)

  • 김창완
    • 한국정보통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.91-99
    • /
    • 2018
  • 본 논문에서는 텔레비전 유휴 주파수 대역(470 MHz ~ 698 MHz)에서 적용 가능한 우수한 수신감도와 높은 선형 특성을 동시에 확보할 수 있는 RF 수신기 구조와 회로 구조를 제안하였다. 제안하는 RF 수신기는 $0.13-{\mu}m$ CMOS 공정으로 설계되었으며, 저잡음 증폭기, 고주파 대역 통과 필터, 고주파 증폭기, 수동 하향 주파수 변환기, 그리고 기저 대역 통과 필터로 구성되어 있다. 높은 수신감도를 얻기 위해 저잡음 증폭기와 고주파 증폭기를 적용하였으며, 인접 채널에 위치하는 인터피어러를 고주파 대역에서 필터링하기 위해 MOS 스위치와 커패시터를 이용한 고주파 대역 통과 필터와 수동 하향 주파수 변환기를 동시에 사용하였다. 제안된 4차 저역통과 필터는 공통-게이트 증폭기에 기존의 바이쿼드 셀을 적용하여 -24dB/oct 필터링 특성을 얻었다. 모의 실험결과로부터 설계된 RF 수신기는 56 dB의 전압이득, 2 dB 이하의 잡음 지수, -2.3 dBm의 IIP3 (out-of-channel) 성능을 제공하며, 1.5 V 전원으로부터 37 mA를 소모 한다.

손목형 생체신호수집 장치에 대한 연구 (A Study on Wrist Band Type Vital Sign Acquisition Device)

  • 김희훈;김경호
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.857-861
    • /
    • 2016
  • In this study, we proposed a new method that can be measure ECG (Electrocardiography) and PPG (Photoplethysmography) in realtime on the site of the wrist for check the state of health in daily life. For convenience measurement of ECG the lead I method was used on the wrist, and omit the reference junction ECG I was measured in the right hand and the left hand of the potential difference. Then the measured electrocardiogram was amplified by the differential amplifier and the signals were passed HPF, LPF, and BPF filters. For removing the PPG's noise from the Motion artifact and temperature, we apply the reflective photoelectric volume pulse wave measurement method using green LED as a light source. The circuits was designed to be able to check the waveform using higher active amplification method at weak signals. For the validation of our device, the measured signals were compared with E2-KIT on same time. The results shows that the error does not exceed the maximum one, most of the data is confirmed to be issued Peak inspection of the same number.

마이크로파 응용을 위한 고온초전도 필터 서브-시스템

  • 강광용;김현탁;곽민환
    • 한국전자파학회지:전자파기술
    • /
    • 제14권3호
    • /
    • pp.20-40
    • /
    • 2003
  • 고온초전도 필터의 무부하 양호도 값(unloaded Q-value)이 매우 높기 때문에, 삽입손실의 증가없이 극수(pole number)를 크게 증가시킨 대역통과 및 저역통과 필터를 제작할 수 있다(현재, 70-pole 대역통과 필터가 개발). 초전도 필터는 급준한 스컷 특성과 차단대역에 대한 양호한 감쇠수준을 얻을 수 있고, 집중상수형 공진기(lumped element resonators)를 사용하거나 지연파(slow wave) 특성을 활용하면 소형화가 가능하다. 다성분계인 산화물(oxide) 고온초전체를 에피택셜 박막 및 대면적(4-인치급) 박막으로 제조함으로서 다양한 구조의 평면형(planar type) 필터 개발뿐만 아니라, 전력처리력(power handling capability)도 향상시킬 수 있게 되었다. 최근에 고온초전도 평면형 필터는 반도체 저잡음 증폭기(GaAs-based LNA), 초소형 냉각기(mini-cooler)와 집적되어 서브-시스템화되었다. 그리고 이동통신 기지국용 수신전치부(receiver front-end) 서브-시스템으로 발전하여 통신시스템의 잡음수준과 인접한 주파수 대역에 의한 전파간섭을 현저히 줄일 수 있고, 동시에 주파수 이용효율의 향상과 통신시스템의 용량증대도 가능케 하고 있다. 본고에서는 고온초전도체 필터의 원리, 종류 및 설계법, 그리고 초전도 필터의 특징과 상품화의 요구사항에 대해 알아보고, 이동통신 기지국 수신 전치부용으로 사용되고 있는 고온초전도 필터 시스템개발과 관련된 연구 및 시장 동향의 특징들을 살펴보고자 한다.

부품 허용 오차에 둔감한 60Hz 대역 억제 필터 설계 (Design of a 60 Hz Band Rejection FilterInsensitive to Component Tolerances)

  • 천지민
    • 한국정보전자통신기술학회논문지
    • /
    • 제15권2호
    • /
    • pp.109-116
    • /
    • 2022
  • 본 논문에서는 센서 시스템에 유입된 60Hz 라인 주파수 잡음의 영향을 효과적으로 제거하기 위한 상태 변수 필터(state variable filter, SVF) 구조의 대역 억제 필터(band rejection filter, BRF)를 제안한다. 기존 SVF 구조의 BRF는 추가적인 연산 증폭기(operational amplifier, OPAMP)를 사용하여 저역 통과 필터(low pass filter, LPF) 출력과 고역 통과 필터(high pass filter, HPF) 출력 간의 합 또는 입력 신호와 대역 통과 필터(band pass filter, BPF) 출력 간의 차를 구함으로써 구현한다. 따라서 BRF의 신호 감쇄를 결정하는 노치 주파수(notch frequency)와 노치 깊이(notch depth)가 신호의 합 또는 차를 구하는데 사용한 저항의 허용 오차(tolerance)에 크게 의존된다. 반면에 제안 된 BRF는 SVF 구조 내에 BRF 출력이 자연발생적으로 형성되기 때문에 각 포트 간의 조합이 필요 없게 되어 기존 BRF와 달리 노치 주파수와 노치 깊이가 저항의 허용 오차에 영향을 받지 않는다. 제안된 BRF의 노치 주파수는 59.99Hz이며 몬테 카를로 시뮬레이션 결과를 통해 저항의 허용 오차에 전혀 영향을 받지 않는 것을 확인할 수 있었다. 노치 깊이도 평균 -42.54dB, 표준편차 0.63dB를 가져 BRF로서 정상적인 동작이 가능함을 확인하였다. 또한 제안된 BRF를 가지고 60Hz 잡음에 간섭이 된 심전도 신호에 대하여 잡음 필터링을 적용한 결과를 보여주었으며 60Hz 잡음이 적절하게 억제되는 것을 확인할 수 있었다.

볼로미터형 테라헤르츠 센서의 광학적 특성 연구 (Optical Characteristics of Bolometric Terahertz Sensor)

  • 한명수;송우섭;홍정택;이동희
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.335-339
    • /
    • 2018
  • The optical characteristics of a terahertz (THz) antenna-coupled bolometer (ACB) detector were evaluated using a pulsed quantum cascade laser (QCL) and radiation blackbody sources. We investigated a method for measuring the responsivity and noise-equivalent power (NEP) of the THz detector using two different types of light sources. When using a QCL source with a frequency of 3 THz, the average responsivity of 24 devices was $1.44{\times}10^3V/W$ and the average NEP of those devices was $3.33{\times}10^{-9}W/{\surd}Hz$. The average responsivity and NEP as measured by blackbody source were $1.79{\times}10^5V/W$ and $6.51{\times}10^{-11}W/{\surd}Hz$, respectively, with the measured values varying depending on the light source. This was because the output power of each light source was different, with the laser source being driven by a pulse type wave and the blackbody source being driven by a continuous wave. The power input to the THz sensor was also different. Futhermore, the responsivity and NEP values measured using band pass filter (BPF) were similar to those measured when using only THz windows. It was found that ACB sensor responds normally in the THz region to both the laser and the blackbody source, and the method was confirmed to effectively evaluate the characteristics of the THz sensor.