• Title/Summary/Keyword: BOD5

Search Result 1,176, Processing Time 0.028 seconds

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

Study on Wastewater of Paper Mill for Coagulant Characteristics (제지폐수의 응집특성에 관한 연구)

  • Cho, Jun-Hyung;Jeong, Won-Gu;Kim, Joon-Hwan
    • Journal of Forest and Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.101-111
    • /
    • 1998
  • Sedimentation characteristics SS, $BOD_5$ and removal efficiency of waste water in the tissue paper mill using milk carton were examined. Optimum dosage of coagulant, rapid mixing time and slow mixing time were determined by turbidity, SS and S-$BOD_5$ and then equation for treatment efficiency was suggested. For the coagulant, polyaluminium chloride(PAC) are compared with a little better efficiency compare to the aluminium sulfate.

  • PDF

Estimation on Chemical Water Quality Suitability Index for 4 Species of the Mayfly Genus Ephemera (Ephemeroptera: Ephemeridae) Using Probability Distribution Models (확률분포모형을 이용한 하루살이속(Ephemera) 4종에 대한 화학적 수질 적합도지수 평가)

  • Bongjun Jung;Dongsoo Kong
    • Journal of Korean Society on Water Environment
    • /
    • v.39 no.6
    • /
    • pp.475-490
    • /
    • 2023
  • Chemical water quality suitability for species (Ephemera strigata, Ephemera separigata, and Ephemera orientalis-sachalinensis group) of the mayfly genus Ephemera (Order Ephemeroptera) was analyzed with probability distribution models (Exponential, Normal, Lognormal, Logistic, Weibull, Gamma, Beta, Gumbel). Data was collected from 23,957 sampling units of 6,664 sites in Korea from 2010 to 2021. E. orientalis-sachalinensis occurred at the range of BOD5 0.3~11.1 mg/L (the best-fit Lognormal model); T-P 0.007~0.769 mg/L (the Gumbel model); TSS 0.4~142.2 mg/L (the Lognormal model). E. strigata occurred at the range of BOD5 0.4~7.4 mg/L (the Gumbel model); T-P 0.007~0.254 mg/L (the Lognormal model); TSS 0.4~17.1 mg/L (the Lognormal model). E. separigata occurred at the range of BOD5 0.4~2.6 mg/L (the R-Weibull model); T-P 0.007~0.134 mg/L (the Lognormal model); TSS 0.7~10.0 mg/L (the Lognormal model). Habitat suitability range of E. orientalis-sachalinensis was estimated to be 0.4~1.9 mg/L (BOD5), 0.024~0.086 mg/L (T-P), 2.5~22.4 mg/L (TSS); that of E. strigata was 0.4~0.7 mg/L (BOD5), 0.007~0.018 mg/L (T-P), 0.0~1.7 mg/L (TSS); that of E. separigata was 0.0~0.4 mg/L (BOD5), 0.000~0.015 mg/L (T-P), 0.5~3.1 mg/L (TSS). In a relative comparision, E. orientalis-sachalinensis was estimated to be eurysaprobic, and narrowly adapted in high levels of T-P and TSS, E. strigata was estimated to be oligosaprobic and adapted in low levels of T-P and TSS, and E. separigata was estimated to be stenooligosaprobic and widely adapted in low level of T-P and TSS.

Analysis of Temperature Effect on Activated Sludge Process at Cheong-Gye Cheon Sewage Treatment Plant (활성오니공법에 있어서 수온이 처리효율에 미치는 영향에 관한 분석 -청계천 하수종말처리장에 대하여-)

  • 이은경
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.9-20
    • /
    • 1981
  • This study was performed to determine the correlationship between temperature and overall removals of BOD, SS and to demonstrate the effect of temperature on treatment performance. These data for a period from February 1, 1977 to January 31, 1980 were obtained from the Cheong-Gye Cheon Sewage Treatment plant. The results of correlation and stepwise multiple regression analysis were as follows. 1) Secondary effluent BOD and SS showed negative correlationship with water temperature, with correlation coefficient of -0.1710, and -0.1654 respectively. 2) Correlation coefficient of BOD, SS removal rate and water temperature were 0.1823 and 0.0429 respectively. 3) Regresion equation for estimate of BOD removal rate was as follows $\widehat{Y}_1$ (BOD removal rate)=63.9994+0.5442X(water temperature). And BOD removal rate showed non significant change according to the water temperature. 4) Regression equation for estimate of SS removal rate was as follows $\widehat{Y}_2$ (SS removal rate)=61.6881+0.1514X(Water temperature). And SS removal rate showed non significant change according to the water temperature. 5) According to the Stepwise Multiple Regression analysis, water temperature ranked second order in the BOD removal rate estimation and the equation was as follows $\widehat{Y}_1$ (BOD removal rate)=69.7398+0.2665 $X_1$ (Primary effluent BOD)+0.3562 $X_2$ (Water temperature)-0.0122 $X_3(Flow)+4413.271X_4$ (Organic Loading).

  • PDF

Comparison of BOD, COD, TOC and DOC as the Indicator of Organic Matter Pollution of Agricultural Surface Water in Gyeongnam Province

  • Lee, Seong-Tae;Lee, Young-Han;Hong, Kwang-Pyo;Lee, Sang-Dae;Kim, Min-Kyeong;Park, Jong-Hwan;Seo, Dong-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.46 no.5
    • /
    • pp.327-332
    • /
    • 2013
  • This survey was conducted to obtain basic data about organic matter such as BOD (Biochemical Oxygen Demand), COD (Chemical Oxygen Demand), DOC (Dissolved Organic Carbon) and TOC (Total Organic Carbon) in agricultural water in Gyeongnam province. BOD and COD are currently used for water quality indices, but adoption of TOC is being suggested. The surface water samples were collected at 39 locations in Gyeongnam province in April, July and October. Average concentrations of BOD, COD, DOC and TOC were 1.6, 3.3, 5.3 and $5.7mg\;L^{-1}$, respectively. In July, average concentrations of BOD and COD were 2.4 and $3.9mg\;L^{-1}$, respectively, showing these values were higher than other months. Average concentrations of TOC in April, July and October were 4.8, 7.4 and $4.8mg\;L^{-1}$, respectively. This suggested that the highest value of TOC was in July. Average decomposition efficiencies for BOD-C/TOC and COD-C/TOC were 11.4 and 23.9%, respectively. Correlation coefficient of TOC and DOC was higher by 0.995, whereas that of TOC and COD was lower by 0.763. Especially, TOC and DOC were highly related than others.

A study on water pollution of the physio-chemical conditions and phytoplankton of the Gumho River. (금호강의 이화학적 조건과 식물성 Plankton에 따른 수질오염에 관한 연구)

  • 강회양;차상은;박선섭
    • Journal of Environmental Health Sciences
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 1982
  • A study on the water pollution of Gumho river by the relationship between physio-chemical conditions and water quality level by phytoplankton was examined at 7 sampling positions during the period from Aug. 1 to Nov. 30, 1981. Examination of physio-chemicat water analysis such as temperature, pH, DO, BOD, and biological analysis are as follows: 1. pH was in the range of 6.6-7.3. 2. At all positions DO was0.5-11.9 mg/l. But at Shinchun bridge and Gangchang was 0.5-3.9 mg/l. 3. BOD was in the range of 3.4-29.2 mg/l. Banyawol, Dongchon and Gumdan was shown good condition. But at Shinchun bridge was 21.1-29.2 mg/l. 4. The plankton identification in this study period showed, Cyanophyceae is 7 genera 13 species, Bacillariophyceae is 11 genera 32 species, and Chlorophceae is 17 genera 27 species: total 35 genera 72 species. 5. In the point of phytoplankton classification, upper stream of Banyawol, Dongchon and Gumdan which BOD was 3.4-8.7 mg/l, dominant phytoplanktons were Synedra ulna, Ulothrix sp., Oscillatoria sp. and Frusturia rhomboides. At Shinchun bridge which BOD was 21.1-29.2 mg/l, Microcystis aeruginosa, Closterium acerosum and Oscillatoria sp were found a small. At 3rd gongdan which BOD was 9.2-12.5 mg/l, dominant species were Synedra ulna, Hormidium sp and Actinastrum hantzschii. At Paldal which BOD was 7.8-9.2 mg/l, dominant species were Nitzschia palea, Synedra ulna and Scenedesmus bijuga. At Gangchang of down stream which BOD was 6.9-9.2 mg/l, dominant phytoplanktons were Closterium acerosum, Microcystis aeruginosa and Actnastrum hantzschii. 6. The results of biological water analysis by saprobic system were as follows: Banyawol was from oligosaprobic to $\beta$-mesosaprobic, Dongchon and Gumdan was from $\beta$-mesosaprobic to $\beta$-mesosaprobic, Shinchun bridge was polysaprobic, 3rd gongdan was from $\alpha$-mesosaprobic to $\beta$-polysaprobic, Paldal was $\beta$-polysaprobic and Gangchang was $\alpha$-polysaprobic.

  • PDF

Improvement of Channel Water Quality Module in SWAT (SWAT 모형의 하도 수질 모듈의 개선)

  • Kim, Nam-Won;Shin, Ah-Hyun
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.902-909
    • /
    • 2009
  • With various reservoirs, dams and reduction of water velocity in downstream, rivers in Korea often have characteristics of accumulation of pollutants. Therefore, the main focus of water quality modeling in Korea needs to be shifted from DO to algae and organic matter. Moreover the structures of water quality models should be modified to have capability of simulating BOD which is a key factor of total water pollution load management in Korea as laboratory experiment BOD (Bottle $BOD_5$). In the SWAT model which is one of the widely used water quality models in Korea, the channel water quality module is using main algorithm of the QUAL2E model which has limitations in simulating algae, organic matter and Bottle BOD5 etc. To overcome this hindrance, in this study, the improved channel water quality module of the SWAT model (Q-SWAT) was proposed by linking the algorithms of the QUAL-NIER model which was developed based on the QUAL2E model to the SWAT model. The algorithms estimating the increase of internal organic matter by fractionization algal metabolism process and calculating Bottle $BOD_5$ were added and the results of proposed model were compared to those of the original SWAT model. The results of comparison test are showing that more accurate BOD values can be obtained with the Q-SWAT model and it is anticipated that the Q-SWAT model can be used as an effective tool of decision support through the water quality simulation and long term pollution source analysis.

A Study on the Wastewater Treatment Characteristics of the Intermediately Aerated Fluidized Bed (간접포기식 유동상법에 의한 폐수처리 특성에 관한 실험적 연구)

  • Lee, Jeoung Su;Kim, Hwan Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.2
    • /
    • pp.367-378
    • /
    • 1994
  • The wastewater treatment characteristics of the fluidized bed filled with sand media and intermediately aerated were studied experimentally, and the obtained results were as follows; 1. The formations of biofilm on the media were greatly affected by the recirculation velocities. 2. Under the experimental condition that BOD loading rate was $4.2kg-BOD_5/m^3{\cdot}d$, the optimum media concentration was $261kg/m^3$ and the optimum recirculation velocity 1.35 cm/sec. 3. For the effluent quality of 20 mg-BOD/l and 20 mg-SS/l, the maximum allowable loading rate was about $8kg-BOD_5/m^3{\cdot}d$. 4. The dry density of biofilm was about 5.6% regardless of the filled media quantities and recirculation velocities. 5. Under the experimental conditions, the effluent solids concentration was below 20 mg/l, and the elimination of final clarifier can be expected.

  • PDF

Reuse of the sewage from sea area using the Submerged Moving Media Complete Mixing Activated Sludge (SMMCMAS) (회전매체를 가진 완전혼합활성슬러지 공법을 이용한 온천지구 하수의 재이용)

  • 김홍태;김학석
    • Journal of Environmental Science International
    • /
    • v.11 no.1
    • /
    • pp.69-74
    • /
    • 2002
  • This study was performed to evaluate an applicability of the SMMCMAS system for reuse of the sewage from spa area and was operated to HLR(Hydraulic loading rate) of 211.3 to 126.8 $\ell$/㎥/d. The operating HRT(Hydraulic retention time) ranges were 2.5 to 1.5 hours. Conclusions are as follows; At the optimum HLR of 158.5 $\ell/\m^2$/d (HRT of 2.0 hours), the maximum BOD removal efficiency was 94% and the effluent BOD concentration was 1.1mg/$\ell$ in result. As the HLR was increased to 211.3 $\ell/\m^2$/d, BOD removal efficiency was decreased to 75% and BOD removal efficiency was also reduced to 74% at lower HLR of 126.8 $\ell/\m^2$/d. It shows that the maximum BOD removal efficiency occurs at an optimum HLR value and that the removal efficiency decreases when the HLR is either higher or lower than the optimum value. Sludge production rates were ranged 0.01 to 0.24gVSS/gBODrem/d and accomplished to 0.01gVSS/gBODrem/d at the optimum HLR of 158.5 $\ell/\m^2$/d.

The State and Sources of Contamination with BOD, COD, T-N and T-P in Stream Within Chonju City (전주시 하천의 BOD, COD,총질소, 총인에 대한 수질현황 및 오염원)

  • 오창환;이지선;김강주;황갑수
    • Economic and Environmental Geology
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2002
  • The Chonju and Samchun streams are palling though Chonju City and several contamination sources are located along these streams. The Samchun stream joins the Chonju stream in the Gosapyeong waste disposal site and the Chonju stream finally joint to the Mankyeong River. The Chonju and Samchun streams are now contaminated with BOD, COD, T-N and T-P and the amounts of each contamination are increasing from upper stream to downstream. At the downstream the amounts of COD. T-N.T-P are several times higher than fifth grade of water quality thor lacustrine. Sewage from Chonju provides BOD, COD,T-N and T-P into the Chonju and Samchun streams and Chonju Waste Water Treatment Plant il a main source of COD, T-N and T-P contamination. Gosapyeong waste disposal site may be the source of BOD and COD contamination. T-N is higher than fifth grade of water quality for lacustrine at the upper stream indicationg that the rivers are contaminated with T-N before inflowing into Chonju by agricultural activity. The Chonju stream asffects the contamination of the Mankyeong river with BOD. COD, T-N,T-P. Other branch steams of the Mankyeong river also affects the contamination of the Mankyeong river by BOD, COD, T-N and T-P, Among the branch streams, the Ikasn stream is a main contamination source. Amounts of concentrations inflowing from the Chonju and Sanchun Streams on Aug. 1999 are calculated by using yeasured flow rate find concentrations of contaminants The result are as fikkiws; 1) the amounts of influent from the Gosan Stream are 0.49, 0.86, 1.61 and 0.01 ton/day for BOD, COD, T-N and T-P, respectively, 2) compared to the amounts of influent from the Gosan Stream, BOD, COD,T-N,T-P supplied from the Chonju river are higher by about 5, 7, 7. 36 times, respectively, and those supplied from the Iksan stream are higher by about 13, 10, 10, 147 times, respectively.