• 제목/요약/키워드: BOD-SS loading

검색결과 95건 처리시간 0.028초

다변량분석법을 이용한 금강 유역의 수질오염특성 연구 (Evaluation of the Geum River by Multivariate Analysis: Principal Component Analysis and Factor Analysis)

  • 김미아;이재관;조경덕
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.161-168
    • /
    • 2007
  • The main aim of this work is focus on the Geum river water quality evaluation of pollution data obtained by monitoring measurement during the period 2001-2005. The complex data matrix 19 (entire monitoring stations)*13 (parameters), 60 (month)*13 (parameters) and 20 (season)*13 (parameters) were treated with different multivariate techniques such as factor analysis/principal component analysis (FA/PCA). FA/PCA identified two factor (19*13) classified pollutant Loading factor (BOD, COD, pH, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P, Chl-a), seasonal factor (water temp, SS) and three Factor (60*13, 20*13) classified pollutant Loading factor (BOD, COD, Cond, T-N, T-P, $NH_3$-N, $NO_3$-N, $PO_4$-P), seasonal factor (water temp, SS) and metabolic factor (Chl-a, pH). Loadings of pollutant factor is potent influence main factor in the Geum river which is explained by loadings of pollutant factor at whole sampling stations (71.16%), month (52.75%) and season (56.57%) of main water quality stations. Result of this study is that pollutant loading factor is affected at Gongju 1, 2, Buyeo 1, 2, Gangkyeong, Yeongi stations by entire stations and entire month (Gongju 1, Cheongwon stations), April, May, July and August (buyeo 1) by month. Also the pollutant Loading factor is season gives an influence in winter (Gongju 1, buyeo 1) from main sampling stations, but Cheongwon characteristic is non-seasonal influenced. This study presents necessity and usefulness of multivariate statistic techniques for evaluation and interpretation of large complex data set with a view to get better information data effective management of water sources.

관리 우선순위 선정을 위한 낙동강 지류·지천 지점의 수질 오염 특성 분석 (Water Quality Analysis in Nakdong River Tributaries for the Determination of Priority Management Areas)

  • 임태효;나승민;신상민;손영규
    • 대한환경공학회지
    • /
    • 제38권10호
    • /
    • pp.558-565
    • /
    • 2016
  • 낙동강 195개 지류 지천 지점에서 2015년 수집된 699회의 유량 및 BOD/COD/T-N/T-P/SS/TOC 농도 등의 수질 자료를 이용하여 중점관리지점 선정 연구를 수행하였다. 각 모니터링 지점에서 BOD, T-P, TOC 농도 및 오염부하량에 대한 변동계수가 매우 크게 확인되어 1년 평균 자료를 이용한 중점관리지점 선정이 경우에 따라 불합리할 수 있을 것으로 지적되었다. 이러한 이유로 본 연구에서는 각 모니터링 자료를 평균화하지 않고 독립적으로 이용할 수 있는 두 가지 방법을 제시하였다. 첫 번째 방법으로 각 모니터링 시점별로 수집된 BOD, T-P, TOC 농도를 낙동강 중권역별 목표수질과 비교하여 목표수질을 초과하는 횟수를 각 지점별로 산정하였다. 두 번째로 BOD, T-P, TOC 항목에 대한 오염부하량을 각 모니터링 시점별 및 지점별로 산정하여 % 순위를 산정하는 방법을 적용하였다. 이상의 방법을 통해 결정된 중점관리지점을 서로 비교하였으며, 이를 통해 낙동강 유역의 수질의 전반적 특성을 분석하였다.

신양천 하천수정화 연못시스템의 처리수준 및 연못반응 (Treatment Level and Reactions of a Treatment Pond System Purifying Sinyang Stream Water)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제8권6호
    • /
    • pp.1-12
    • /
    • 2005
  • Treatment level and pond reactions of a pond system were examined from May to October 2002. The system was constructed in July 2000 for purifying water of Sinyang stream that flows into Koheung Estuarine Lake located in the southern part of the Korean Peninsula. The system was composed of a primary and a secondary pond in series and established on the rice field near the lake. Water pumped from the stream was funneled into the primary pond, whose effluent was discharged into the secondary pond by gravity flow. Effluent from the secondary pond was funneled into wetlands. About 130 $m^3$/day of water was pumped into the primary pond and detention time of the primary and secondary pond was about 2 days. DO from the surface to the 1.0 m depth of the primary and secondary pond was in the rage of 5.2 to 11.0 mg/L and 4.3 to 0.7 mg/L, respectively. DO at the bottom layer of the primary pond was 0 mg/L and that of the secondary pond ranged 3.0~4.7 mg/L. The primary pond functioned as a facultative pond and the secondary as an aerobic one. The temperature difference between the surface and bottom layers of the ponds in August was about $2.5^{\circ}C$ and that in May and October was about $1.0^{\circ}C$. Thermocline was observed in the primary pond during the high ambient temperature of August. The sludge depth of the primary pond in May, August, and October was 2.4, 1.9, and 2.2 cm, respectively. That of the secondary pond was 1.2, 1.0, and 1.1 cm, respectively. SS, $BOD_5$, T-N, and T-P concentrations in influent averaged 16.64, 6.71, 6.21, and 0.23 mg/L and those in effluent from the primary pond averaged 11.48, 4.97, 4.81, and 0.17 mg/L, respectively. The removal rates of the primary pond for SS, $BOD_5$, T-N and T-P were 31%, 26%, 22%, and 24%, respectively. Average concentrations of SS, $BOD_5$, T-N, and T-P in effluent from the secondary pond were 9.81, 4.07, 4.03, and 0.14 mg/L, respectively and the abatement rates of the secondary pond for SS, $BOD_5$, T-N and T-P were 20%, 12%, 13%, and 15%, respectively. SS, $BOD_5$, T-N and T-P concentrations in effluent from the primary pond were significantly low(p=0.001) when compared with those from the secondary one.

침지형 membrane을 이용한 생활오수처리 (Municipal Wastewater Treatment by Submerged Membrane Process)

  • 김광남;정순형;정우영;윤용수
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.105-112
    • /
    • 1999
  • The removal characteristic of BOD, COD,T-N, and T-P was investigated in municipal wastewater treatment with anoxic and membrane submerged aerobic reactor. It was found that BOD and COD removal rate were obtained 90% and 92%, respectively, for 90 days operation. BOD and COD loading rate did not affect to the removal efficiency because MLSS concentration in aerobic tank was highly maintained.In the case of first reactor operated with anoxic and second reactor operated as aerobic, T-N, T-P removal rate were obtained 93% and 99% respectively.It was shown that removal efficiency could be maintained stable due to the complete removal of SS and sludge production decreased with increasing of sludge retention time.

  • PDF

불교전통 식생활방식에 따른 수질오염 저감 효과 연구 (A Study on the Effect of Buddhist Dietary Life on the Degradation of Water Pollution)

  • 최광수
    • 한국환경과학회지
    • /
    • 제24권2호
    • /
    • pp.221-228
    • /
    • 2015
  • In this research traditional Buddhist dietary life style was studied as an alternative for both saving water and decreasing water pollution from household. A traditional dietary life style for the Buddhist monks, called Balwoo Gongyang, and its modernized one for citizens, called Dish Gongyang were examined with water use amount, wastewater quality and pollutant loading rate, and were compared with the kitchen wastewater from household. And several types of natural detergent were also examined to compare their effect on the wastewater quality and pollutant loading rate. This research was carried out using the wastewater from Balwoo and Dish Gongyang in J building located in Seoul. Wastewater generation from Balwoo Gongyang that was about $1.0{\ell}$/capita/day was very low compare to that from dish washing in normal household($32.6{\ell}$/capita/day). In case of Dish Gongyang, water generation was 1.8 times higher than that from Balwoo Gongyang, but it was just 1/19.2 of normal household. When the wastewater quality of Balwoo Gongyang was compared with the kitchen wastewater of normal household, SS was 1/16($15mg/{\ell}$), COD was 1/7($22.1mg/{\ell}$), BOD was 1/9($24.1mg/{\ell}$) and T-N was 1/16($1.7mg/{\ell}$). Pollutant loading rate from Balwoo Gongyang was very low, COD 18.0 mg/capita/day, SS 12.3 mg/capita/day and it was 1/290, 1/639 of that from dish washing wastewater from normal household, respectively. Pollutant loading rate from Dish Gongyang was also low 1/13(SS)~1/144(TN) compared to dish washing wastewater from normal household. As a natural detergent, used water from washing rice showed very low pollutant loading rate. It was concluded that Dish Gongyang that was a modernized and simplified dietary life style of Balwoo Gongyang, was very eco-friendly. Especially when it was combined with natural detergents using by-product from cooking process, its effect on the water pollution was very low.

분뇨처리(糞尿處理) : 혐기성소화(嫌氣性消化) 온도영향(溫度影響) (Nightsoil Treatment: Temperature Effects on Anaerobic Digestion)

  • 최의서;이병헌;이찬기
    • 대한토목학회논문집
    • /
    • 제2권3호
    • /
    • pp.23-32
    • /
    • 1982
  • 본연구(本硏究)는 다절기(多節期)에는 저온(低溫)으로 하절기(夏節期)에는 고온(高溫)으로 혐기성(嫌氣性) 소화조(消化槽)를 운전(運轉)시킬 수 있는지를 검토(檢討)하기 위한 것으로 실험실(實驗室) 완전혼합형(完全混合型) 혐기성(嫌氣性) 소화조(消化槽)를 $18.5^{\circ}C$ 부터 $60^{\circ}C$까지의 11단계(段階)의 온도(溫度)에서 유기물질(有機物質)의 제거효율(除去効率) 가스생산량(生産量)을 서로 비교(比較)하였다. $35^{\circ}{\sim}40^{\circ}C$ 내외(內外)에서 BOD와 VS 제거효율(除去効率)은 각각(各各) 71%와 53%였으며 이 온도(溫度)에 있어서 가스생산량(生産量)은 주입분뇨량(注入糞尿量)의 16배(倍) 또는 $0.63m^3gas/kg$ VS fed 였다. 화조(消化槽) 유출수(流出水)를 심전(沈殿)시키면 BOD제거효율(除去効率)은 78%까지 상계(上界)하였다. 본실험(本實驗)의 결과(結果)는 $32^{\circ}$에서 $47^{\circ}C$로 운전(運轉)시킨 기존(旣存) 분뇨처리장(糞尿處理場)의 결과(結果)와 $40^{\circ}C$까지는 비교적(比較的) 잘 맞았으나 $40^{\circ}C$ 이상(以上)에서는 실험실(實驗室) 결과(結果)가 처리효율(處理効率)이나 가스생산량(生産量)으로 볼 때 양호(良好)하였다. 분뇨(糞尿)에 정화조폐액(淨化槽廢液)이나 우분(牛糞) 혼합처리(混合處理) 가능성(可能性) 검토(檢討)하였는데 1:1로 혼합처리(混合處理)시켰을 때의 BOD제거효율(除去効率)이나 가스생산량(生産量)이 분뇨(糞尿)만의 처리시(處理時)와 별로 차이(差異)가 없었다. 한편 혐기성(嫌氣性) 소화조(消化槽)의 유출수(流出水)를 희석(稀釋)없이 호기성처리(好氣性處理)도 가능(可能)한지 알아 보았는데 이때의 BOD와 SS제거효율(除去効率)은 98% 이상(以上)이었다.

  • PDF

Feasibility Study of Constructed Wetland System for Sewage Treatment in Rural Area

  • Ham, Jong-Hwa;Yoon, Chun-Gyeong
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.426-432
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the feasibility of constructed wetland system for sewage treatment in rural areas. A pilot system was installed in Konkuk University and the effluent of septic tank for school building was used as an influent to the wetland treatment basin. The system was composed of sand and reed, and operated continuously including winter time. Average removal rate of about 70% was observed for BOD, COD, and SS, about 50% for T-P, and about 25% for T-N. The reason for poor T-N removal might be due to high loading rate and short retention time. The system demonstrated satisfactory effluent concentration and stable performance in growing season. And it also worked adequately in wintertime even below $10^{\circ}C$ without freezing, and removal was still significant. The amount removed in BOD, COD, and SS was almost the same as in the growing season, and the amount removed in nutrients was about half of the one in growing season. Overall performance of the experimental system was compared with existing data base (NADB, 1994), and it was within the range of general system performance. As study period increased, removal rates for BOD, COD, SS, and T-P were consistently maintained and even enhanced, but removal rate for T-N decreased slightly. Wetland system was thought to be a feasible alternative for sewage treatment in rural area considering its low cost and low maintenance requirement. However, the effluent of the experimental wetland system often exceeded current effluent water quality standards, therefore, further treatment could be required if the effluent should be discharged to public waters. Wetland system of interest locates in rural area and is a part of rural ecosystem, therefore, ultimate disposal of reclaimed sewage for agricultural purpose or subsequent land treatment might be available and further research in this matter is recommended.

  • PDF

유량-부하량 관계식과 상관관계 분석을 이용한 굴포천의 수질특성 평가 (Evaluation of Water Quality Characteristics in Gul-po Stream using Flow-Loading Equation and Correlation Analysis)

  • 장지윤;김대웅;최예지;장동우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2021년도 학술발표회
    • /
    • pp.452-452
    • /
    • 2021
  • 하천 및 호소수역에 대한 수질오염원이 지속적으로 증가하는 경우에는 일반적인 농도규제 방식으로는 수질개선에 한계가 나타난다. 이를 해결하기 위해 목표 수질 한도 내에서 유역 배출원의 오염물질총량 관리를 목적으로 하는 수질오염총량관리제 개념이 도입되어 단위유역 지자체별 배출부하량을 관리하고 있지만, 지역의 오염원 배출 특성을 고려하지 않은 저감계획은 오히려 유역 내 새로운 오염원으로 전락하여 수질 개선 효과가 나타나지 않을 수 있다. 따라서 효율적인 총량 관리를 위해서는 수계 내 오염원 파악이 필수적이다. 본 연구에서는 수질오염총량제 대상 하천인 굴포천의 수질 오염원 분석을 위해 2016년, 2017년 굴포천 유역 토지이용 자료를 활용하여 수질항목과의 상관성을 파악하고 2016년부터 2020년까지 최근 5년 동안 총량측정망을 통해 측정된 유량 및 수질 자료를 이용해 상류, 중류, 하류 각각의 유량-부하량 관계식을 도출하여 지점별 수질 오염원 특성을 분석하였다. 상관분석 결과, 강우 시 밭과 BOD, SS, T-P는 양의 상관성을 보였고, T-N은 강우, 비 강우 시 관계없이 밭, 논에서 높은 양의 상관성을 보였다. 유량-부하량 관계식 도출 결과, 상류의 경우 BOD, COD, T-P, TOC, SS는 유량이 증가함에 따라 농도가 감소하는 특성을 나타내었는데 이는 2019년 4월 이후 오존처리 재이용수 방류에 따른 유량 증가의 영향이라고 사료 된다. 반면 T-N은 유량이 증가함에 따라 농도가 증가하는 특성을 나타내었는데 이는 오존처리 재이용수의 T-N 농도가 하천의 T-N 농도 보다 높아 발생한 것으로 보인다. 중류와 하류의 경우 BOD, COD, T-P, TOC, SS는 유량이 증가함에 따라 농도가 증가하는 특성을 나타내어 강우 시 비점오염원의 영향이 있는 것으로 보인다. 특히, 하류의 경우 유량이 증가함에 따라 수질 농도가 급격히 증가하여 중류에 비해 비점오염원 영향이 더 큰 것으로 나타났다.

  • PDF

농업유역 비점오염 관리를 위한 동진강 행정교 유역의 수문·수질 모니터링 (Monitoring of Hydrological and Water Quality in Dongjin-River Hengjeong Bridge Watershed for Agricultural Watershed Non-Point Pollutant Sources Management)

  • 손재권;손태호;최진규;조재영;고남영;오진휴
    • 한국농공학회논문집
    • /
    • 제54권4호
    • /
    • pp.55-63
    • /
    • 2012
  • This study was performed to investigate the stream water quality characteristics in Hengjeong Bridge Basin of Dongjin River during twelve months from October, 2010 to September, 2011. Also, pollutant loads were calculated on the basis of the water quality and runoff results. The results showed that ranges of water temperature, pH and EC were $6.2{\sim}23.90^{\circ}C$, 6.32~7.78, $84.4{\sim}126.5{\mu}S/cm$ respectively. The Concentration of DO, BOD, COD, SS, Tot-N and Tot-P were observed as 6.80~9.20 mg/L, 0.40~1.60 mg/L, 1.96~4.41 mg/L, 59.60~142.20 mg/L, 1.28~3.52 mg/L, 0.001~0.07 mg/L respectively. Tot-N showed correlativity with BOD, and Tot-P showed correlativity with SS. The runoff pollutant loading of Tot-N and Tot-P were 117.94 kg/ha and 2.06 kg/ha respectively, in Hengjeong bridge of Dongjin river watershed. In the case of the correlativity between runoff pollutant loads and concentrations, Tot-N and Tot-P show low significant relationships.

수질개선용 인공습지 실험자료에 의한 유출수 농도 추정식 개발 (Development of Effluent Concentration Estimation Equation from Treatment Wetland Experimental Data)

  • 윤춘경
    • 한국농공학회지
    • /
    • 제41권5호
    • /
    • pp.86-92
    • /
    • 1999
  • Effluent concentration estimation equations for wetland system were developed throught statistical analysis of treatment wetland experimental data. Existin g empirical equations were reviewed for thier accuracy with experimental data, and compared with the estimatin equations. About 70 experimental data sets were used for multiple regression, and variables include influent concentration, hydraulic loading rate, average daily air temperature , and plant coverage. The estimatin equations developed for BOD5 , SS ,T-P, and T-N predicted effluent concentrations moderately well, and coefficient fo determination ($R^2$) for them was 0.74 , 0.60, 0.59 and 0.58 respectively. The equations obtained from same data but excluding plant coverage showed relatively lower $R^2$ than the former case, and it was 0.66, 0.52, 0.41 and 0.57 respectively. The EPA, WPCF , and Kadlec and Knight equations worked poorly and $R^2$ for them was significantly lower than the estimation equation developed in the study. The reason might be that the existing equations were oversimplified that they did ot include important parameters such as air temperature and plant coverage. Therefore, developing reasonable estimation equations from experiment under realistic condition is highly recommended rather than using exiting estimation equations.

  • PDF