• Title/Summary/Keyword: BOD sensor

Search Result 22, Processing Time 0.026 seconds

Yeast Loading BOD Biosensor (효모균을 이용한 BOD Biosensor)

  • Kim, Mal-Nam
    • The Korean Journal of Mycology
    • /
    • v.23 no.4 s.75
    • /
    • pp.354-358
    • /
    • 1995
  • A yeast loading biochemical oxygen demand (BOD) sensor was designed and constructed to quickly measure the concentration of biologically assimilable organic substances dissolved in water as BOD values to feed back to the waste water treating processes. The sensitivity of the BOD sensor reached maximum at around pH 7.0 and $30^{\circ}C$ where yeast showed the highest assimilation activity. Biomass also affected the sensor output, and biomass of $ 0.14\;mg/cm^2$ on the dialysis membrane appeared to be the optimum cell mass level. The sensitivity of the sensor depended on the kinds of pollutants and increased considerably when the yeast was preincubated in the solution of respective pollutants before loading on the sensor.

  • PDF

BOD Determination by Heavy Metal Tolerant Candida sp. LSY2 (Candida sp. LSY2 중금속 내성주를 이용한 BOD 분석)

  • 김말남;이선영
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.4
    • /
    • pp.415-420
    • /
    • 1999
  • A biochemical oxygen demand (BOD) sensor loaded with Candida sp. was designed and constructed for the quick measurement of the concentrations of biologically assimilable organic substances dissolved in water. The sensitivity of the sensor was higher for glucose, acetic acid, aspartic acid and glutamic acid than that for lactose, sucrose and lactic acid. The sensitivities of BOD sensors loaded with $Zn^{2+}$ tolerant and intact strains were almost identical while the sensitivity of sensor loaded with Cd$^{2+}$ tolerant strain was considerably lower. The sensitivities of the sensors loaded with intact or $Zn^{2+}$ tolerant strains did not change with the concentration of $Cd^{2+}$ in the aqueous solution while the sensitivity of the sensor loaded with $Cd^{2+}$ tolerant strain decreased slightly. The sensitivities of the sensors loaded with intact strain, $Zn^{2+}$ or $Cd^{2+}$ tolerant strains were not affected by the concentration of $Zn^{2+}$ in the aqueous solution.n.

  • PDF

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF

Microbial BOD Sensor Using Hansenula anomala

  • Ihn Gwon-Shik;Park Kyung-Ho;Pek Un-Hua;Sohn Moo-Jeong
    • Bulletin of the Korean Chemical Society
    • /
    • v.13 no.2
    • /
    • pp.145-148
    • /
    • 1992
  • A microbial sensor for BOD (Biochemical Oxygen Demand) measurement has been developed by immobilizing Hansenula anomala in a polyacrylamide gel. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $30^{\circ}C$, respectively. The response time was 30 min. A linear relationship was observed between the potential and the concentration below 44 ppm BOD. The potential was reproducible within ${\pm}9%$ of the relative error when a sample solution containing 20 mg/l of glucose and 20 mg/l of glutamic acid was employed. The effect of various compounds on BOD estimation was also examined. The potential output of the sensor was almost constant for 30 days. The relative error in BOD estimation was within ${\pm}10%$.

Sensitivity of BOD Sensor with Heavy Metal Tolerant Serratia marcescens LSY4 (Serratia marcescens LSY4 중금속 내성주를 이용한 BOD센서의 감응도)

  • Kim Mal-Nam;Lee Sun-Young
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.394-399
    • /
    • 2004
  • A BOD sensor was prepared with S. marcescens LSY4 and was applied for measurement of BOD values of a solution containing the standard organic pollutants. The sensor sensitivity was nearly independent of the culture time in the range of 9-16 hours. It was also affected little by the cell mass in the range of 0.22-0.75 mg $cm^{-2}$. A cyclic change in the solution pH in the range of 4-9 was accompanied by a reversible variation in the sensor sensitivity. However, the reversibility was lost when the solution pH became more acidic or more basic. Heavy metal ions lowered the sensor sensitivity, which took place more precipitously in the presence of $Cu^{2+}$ and $Ag^+$ rather than in the presence of $Zn^{2+}$ and $Cd^{2+}$. The reduction of the sensor sensitivity was significantly attenuated by loading heavy metal ion tolerance induced strain. The $Cu^{2+}$tolerance induced strain was more efficient for the attenuation than $Zn^{2+}$ and $Cd^{2+}$ tolerance induced strain.

Mixed Bacillus sp. BOD sensor (혼합 Bacillus sp. BOD 센서)

  • Kang, Tae Young;Park, Hyun Joo;Park, Kyeong Ryang;Kim, Jin Doo;Cha, Geun Sig;Nam, Hakhyun
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-9
    • /
    • 2007
  • The BOD (biochemical oxygen demand) sensor was fabricated by covering a dissolved oxygen (DO) probe with a microbe-impregnated membrane and a dialysis membrane. Various microorganisms isolated from the soils, water and activated sludge have been evaluated for measuring biochemical oxygen demand (BOD); Bacillus species HN24 and HN93 were selected as they exhibited rapid oxygen consumption and fast recovery. Improved BOD sensor could be prepared by using mixed microbes (Bacillus subtilis, Bacillus sp. HN24 and Bacillus sp. NH93) and silicon rubber gas-permeable membrane for DO probe, and by bubbling 50% $O_2$ ($N_2$ valence) through background buffer solution. This system exhibited excellent analytical performance resulting in good linearity ($r^2=0.9986$) from 0 to 100 mg/L level of BOD.

Comprehension of the Response Time in a Microbial BOD Sensor(II)

  • Sohn, Moo-Jeong;Hong, Dae-Il
    • Bulletin of the Korean Chemical Society
    • /
    • v.14 no.6
    • /
    • pp.666-668
    • /
    • 1993
  • A microbial BOD sensor using immobilized Hansenula anomala was prepared for the estimation of BOD. The sensor voltage was increased with time and increasing concentration of GGA when it was inserted in a sample solution. A linear relationship was obtained with a correlation coefficient, 0.998 between the concentration of standard GGA solutions and dV/dt by using the initial change of voltage, in which the response time was 20 min. It could be concluded that the oxidation of GGA conformed to a first-order kinetics. Therefore, the good linearities were also observed at various times. This sensor showed the best linearity at 30 min.

A Study on the On-line Measurement of Biochemical Oxygen Demand of livestock Wastewater (축산 폐수의 생물화학적 산소요구량 자동 측정 방법에 관한 연구)

  • Kim, Hyoung-Mo;Kim, Jin-Kyong;Shin, Kwan-Suk;Kim, Jun-Hyung;Jung, Jae-Chil;Kim, Tai-Jin
    • KSBB Journal
    • /
    • v.23 no.4
    • /
    • pp.317-322
    • /
    • 2008
  • The Biochemical Oxygen Demand(BOD) is one of important parameters for the most widely used method of organic pollution in wastewater and wastewater treatment effluent. As the conventional BOD test needs 5-day long incubation period, it is thus incompatible with real time control of wastewater treatment plant. To resolve this problem, in the present study an on-line Dissolved Oxygen(DO) monitoring system was used to observe the transient change of dissolved oxygen concentration in livestock wastewater. The system was composed of BOD sensor, amplifier and computer. It was observed that the concentration of the microorganism in the livestock wastewater was relatively constant during the growth period of initial one hour, which allowed the assumption of the constant Oxygen Uptake Rate(OUR) within one hour of measurement. It was thus concluded that the present scheme provided a protocol for automatic measurement of BOD in livestock wastewater, which can be applicable to optimal control of livestock wastewater treatment plant.

Examining Synchronous Fluorescence Spectra of Dissolved Organic Matter for River BOD Prediction (하천수 BOD 예측을 위한 용존 자연유기물질의 synchronous 형광 스펙트럼 분석)

  • Hur, Jin;Park, Min-Hye
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.2
    • /
    • pp.236-243
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter (DOM) have the superior advantages over other analysis tools for the applications to water quality management due to their rapid analysis. It is known that protein-like fluorescence characteristics are well corelated with microbial activities and biodegradable organic matter. In this study, potential biochemical oxygen demand (BOD) predictor were explored using the fluorescence peak intensities and/or the integrated fluorescence intensities derived from synchronous fluorescence spectra and the first derivative spectra of river samples. A preliminary study was conducted using a mixture of a river and a treated sewage to test the feasibility of the approach. It was demonstrated that the better BOD predictor can be derived from synchronous fluorescence spectra and the derivatives when the difference between the emission and the excitation wavelengths (${\Delta}{\gamma}$) was large. The efficacy of several selected fluorescence parameters was rivers in Seoul. The fluorescence parameters exhibited relatively good correlation coefficients with the BOD values, ranging from 0.59 to 0.90. Two parameters were suggested to be the optimum BOD predictors, which were a fluorescence peak at a wavelength of 283 nm from the synchronous spectrum at the ${\Delta}{\gamma}$ value of 75 nm, and the integrated fluorescence intensity of the first derivatives of the spectra at the wavelength range between 245 nm and 280 nm. Each BOD predictor showed the correlation coefficients of 0.89 and 0.90, respectively. It is expected that the results of this study will provide important information to develop a real-time efficient sensor for river BOD in the future.

Analysis of Non-Point Pollution Sources in the Taewha River Area Using the Hyper-Sensor Information (하이퍼센서 정보를 이용한 태화강지역의 비점오염원 분석)

  • KIM, Yong-Suk
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.1
    • /
    • pp.56-70
    • /
    • 2017
  • In this study, multi-image information for the central Taewha River basin was used to develop and analyze a distribution map of non-point pollution sources. The data were collected using a hyper-sensor (image), aerial photography, and a field spectro-radiometer. An image correction process was performed for each image to develop an ortho-image. In addition, the spectra from the field spectro-radiometer measurements were analyzed for each classification to create land cover and distribution maps of non-point pollutant sources. In the western region of the Taewha River basin, where most of the forest and agricultural land is distributed, the distribution map showed generated loads for BOD($kg/km^2{\times}day$) of 1.0 - 2.3, for TN($kg/km^2{\times}day$) of 0.06 - 9.44, and for TP($kg/km^2{\times}day$) of 0.03 - 0.24, which were low load distributions. In the eastern region where urbanization is in progress, the BOD, TN, and TP were 85.9, 13.69, and 2.76, respectively and these showed relatively high load distributions when the land use was classified by plot.