• Title/Summary/Keyword: BOD decay rate

Search Result 13, Processing Time 0.017 seconds

Experimenting biochemical oxygen demand decay rates of Malaysian river water in a laboratory flume

  • Nuruzzaman, Md.;Al-Mamun, Abdullah;Salleh, Md. Noor Bin
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.99-106
    • /
    • 2018
  • Lack of information on the Biochemical Oxygen Demand (BOD) decay rates of river water under the tropical environment has triggered this study with an aim to fill the gap. Raw sewage, treated sewage, river water and tap water were mixed in different proportions to represent river water receiving varying amounts and types of wastewater and fed in a laboratory flume in batch mode. Water samples were recirculated in the flume for 30 h and BOD and Carbonaceous BOD (CBOD) concentrations were measured at least six times. Decay rates were obtained by fitting the measured data in the first order kinetic equation. After conducting 12 experiments, the range of BOD and CBOD decay rates were found to be 0.191 to 0.92 per day and 0.107 to 0.875 per day, respectively. Median decay rates were 0.344 and 0.258 per day for BOD and CBOD, respectively, which are slightly higher than the reported values in literatures. A relationship between CBOD decay rate and BOD decay rate is proposed as $k_{CBOD}=0.8642_{k_{BOD}}-0.0349$ where, $k_{CBOD}$ is CBOD decay rate and $k_{BOD}$ is BOD decay rate. The equation can be useful to extrapolate either of the decay rates when any of the rates is unknown.

Distribution of BOD Decay Rate in Streams and Reservoirs (국내 수계에서의 BOD분해속도계수 분포)

  • Jang, Changwon;Kim, Donghwan;Lee, Jaeyong;Kim, Yeonju;Jung, Sungmin;Shin, Changmin;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.178-184
    • /
    • 2012
  • BOD decay rate is a key parameter of BOD-DO models in streams and lakes. In the calibration of water quality modeling appropriate range of coefficient is required for guidance of parameter selection. In this study BOD decay rate was measured at 48 stream sites and 10 reservoir sites in 8 different river systems. The decay rate ranged from 0.09 to 0.25 $day^{-1}$ with a mean of 0.16 $day^{-1}$. Among river systems the decay rates showed significantly different ranges, with the Han River system showing higher values than other river systems. In comparing different types of water bodies, the decay rate was slightly higher in tributaries than in reservoirs and mainstreams. Our results can provide guidance to the selection of proper coefficient for various water bodies in the calibration of water quality models.

A Study of Carbonaceous BOD Decay Rates for the Nakdong River Water System (낙동강수계에 대한 탄소성 BOD 분해속도연구)

  • Yoon, Young-Sam;Yu, Jae-Jung;Shin, Chan-Ki
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.833-840
    • /
    • 2008
  • Deoxygenation process in which CBOD(carbonaceous BOD) is biochemically oxidized to reduced inorganic compounds is of great significance in the oxygen demand of stream waters. The CBOD decay rate has traditionally been determined in a laboratory by CBOD bottle incubation method. But in this study, CBOD decay rates were obtained by laboratory incubation method and natural waters experiment. Average CBOD decay rate for the Nakdong river(upper zone) in natural waters were 0.553 $day^{-1}$ during April 2005 to January 2007. The values in the middle and down parts of the Nakdong river in natural waters were 0.384 $day^{-1}$ and 0.252 $day^{-1}$ at the same period of time, respectively. Average CBOD decay rates using by incubation method in the upper/middle/down parts of the main stream in the Nakdong river basin was 0.270 $day^{-1}$, and 0.289 $day^{-1}$, and 0.283 $day^{-1}$ during April 2005 to January 2007, respectively.

Application of QUAL2E Model to Water Quality Prediction of the Nam river (남강의 수질예측을 위한 QUAL2E 모델 적용)

  • Choi, Hyoung-Sub;Park, Tae-Ju;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.14 no.1
    • /
    • pp.7-14
    • /
    • 1995
  • This research was conducted to apply the QUAL2E model to be adopted to the Nam river under current water quality conditions. The survey area of total 60 Km was divided into five reaches. Each reach was then subdivided into the uniform computational elements of 1.5 Km. Based on the stream characteristics, nine sampling stations consisting of six at main streams and three at tributaries were selected. The field data were obtained from the selected stations twice during October of 1991 and May of 1992, which represented the cold weather and low flow, also the warm weather and low flow conditions, respectively. As the results of sensitivity analysis of the model, the important parameters were the rates of BOD decay, Org-N oxidation, $NH_3-N$ oxidation, Org-P decay. The calibrated and verified results by QUAL2E model were correlation coefficient of $0.45{\sim}0.94$. The results displayed a good agreement between the variables of the field measurements and the model simulations, indicating a potential use of the QUAL2E model for the water quality assessment in the Nam River.

  • PDF

Estimation of CBOD Decay Rate for the Execution of Water Quality Model in the Nakdong-River Basin (낙동강에서 수질모델 실행을 위한 탈산소계수의 평가)

  • Yu, Jae-Jeong;Yoon, Young-Sam;Lee, Hae-Jin;Kim, Moon-Soo;Yang, Sang-yong;Lee, Young Joon
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.511-515
    • /
    • 2005
  • CBOD(carbonaceous BOD) decay rate was investigated for the execution of water quality model in Nakdong-Rive basin. Estimation of laboratory-derived CBOD decay rate, $k_l$ and CBOD decay rate in natural waters, $k_d$ were carried out. Hydraulic factors were applied for the calculation of $k_d$. Values of biochemical oxygen demand were investigated in Weagwan, Koreong, Jeokpo, Namgi and Mulgeom sites for the four times. The ranges of $k_l$ value were $0.04{\pm}0.01{\sim}0.14{\pm}0.03$. The values of $k_l$ in upstream sites were much larger than those in the downstream sites. The values of $k_d$ were 0.025, 0.036, 0.005 and 0.001 at Weagwan, Jeokpo, Namgi and Mulgeom, respectively, indicating that values of $k_d$ were generally larger than those of $k_l$.

Wetland Performance for Wastewater Treatment in Growing and Winter Seasons (생장기와 동절기의 인공습지 오수처리 성능)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.37-46
    • /
    • 1999
  • Field experimnet of constructed wetland for rural wastewater treatment was performed from July 1998 to April 1999 including winter to examine the seasonal effect on the wetland performance. The system worked without freezing even under $-10^{\circ}C$ of air temperature as long as watewater was flowing. BOD removal rates varied in similar pattern as the air temperature, and winter performance was relatively lower than that in the growing season. However, removing performance during winter was still significant, and BOD removal rates were almost the the same as in the growing season. SS removal rate was relativelyless affected by temmperature, but lower decay rate during the winter can result in accumulation of the SS in the system, which releases constituents in the next spring and can affect whole system performance. The winter removal rates of nutrients like T-N and T-P were decreased about half compared to the growing season and low temperature. To maintain stabilized wetland performanced including winter time, supplying minimum heating for plants could be an alternative in field application. Experimental data was compared with NADB(North Americal Wetlands for Water Quality treatment database), and general performance of the system was within the reasonable range. The pollutant loading and effluent concentration of the experimented system were in high margin. Base on the experiment and databases, the required effluent water quality could be achieved if loading rate adjusted as ilulstrated in the database.

  • PDF

Kinetic Analysis for Paper-mill Wastewater Treatment Using Pure Oxygen Activated Sludge Process (순산소 활성오니공정을 이용한 제지폐수처리의 동력학적 해석)

  • Kim, Sung Soon;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.2
    • /
    • pp.157-163
    • /
    • 2000
  • An experimental study was conducted to evaluate the treatment efficiency of paper-mill wastewater using pure oxygen activated sludge process. Effects of hydraulic retention time (HRT) and organic loading on process performance and kinetics were investigated. The raw paper-mill wastewater(BOD concentration ${\leq}500mg/L$) and the effluent from dissolved air flotation(DAF) treatment(BOD concentration ${\geq}500mg/L$) were used as influent for pure oxygen activated sludge process. Average BOD removal efficiencies were above 89.3% under 6hours or longer of HRT, while under 3hours of HRT they decreased to about 82%. With the effluent from DAF process, the half saturation constants($K_S$) and the maximum specific substrate removal rate($K_{max}$) were 85 mg/L and 2.25 L/day, respectively. However, with the raw paper-mill wastewater, both $K_S$ and $K_{max}$ increased to 156 mg/L and 3.84 L/day, respectively. The microbial yield coefficient(Y) and the decay coefficient($K_d$) were 0.46 gVSS/gBOD and 0.03 L/day, respectively, with effluent from DAF process. While, Y and $K_d$ were 0.24 gVSS/gBOD and 0.035 L/day, respectively, with the raw paper-mill wastewater.

  • PDF

Treatability Study on the SepticTAnk Sludges

  • Byung Soo Yang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.41-47
    • /
    • 1981
  • The characteristics of septic tank sludges were investigated and the kinetic coefficients in the aerobic biodegradation were evaluated from bach treatability tests. Using an unbiased statistical method, the estimated values, k (substrate removal rate coefficient) =0. 0175hr-1 at 17\ulcornerC, K. (Michaelis Menten constant) = 248mg/ e, a (cell yield coefficient)=0.625, and Kd (cell decay coefficient:' =0. 00192hr-1 were obtained based on biodegradable COD(mg/ \ulcorner) and volatile suspended solids(mg/\ulcorner). The relationship between COD and BOD, COD (mg/\ulcorner) =2. 1 BOD(mg/\ulcorner) +250, also was established for the septic tank sludges. Dilution was inevitable for the grit removal because of the high viscosity of the sludges. An aerobic activated sludge process rather than anaerobic processes was recommended for the removal of soluble organics after the removal of grit and suspended solids. A multi-stage activated sludge process was adapted for this highly concentrated and not easily-degradable waste. It was estimated that a four-stage activated sludge process would require 40 hours retention time compared to 92 hours for a single-stage process, 52 hours for a double-stage process, and 46 hours for a three stage process in order to achieve an effluent quality of 84mg/ e COD( 40mg/ e BOD) with about 4, OOOmg/ \ulcorner MLSS from an influent quality of I, 500mg/ t COD(714mg/.e BOD), while multi-stages beyond four stage would not save the required retention time significantly.

  • PDF

Estimation of Water Quality Variation in Sewer Network using MOUSE TRAP Model (MOUSE TRAP 모델을 이용한 하수관거내 수질변화 예측)

  • Yang, Hae Jin;Jun, Hang Bae;Son, Dae Ik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.743-752
    • /
    • 2009
  • One of the major problems associated with operation of domestic sewer lines involves hydraulic problems such as insufficient conveyance capacity, exceeding maximum velocity, and deficiency of minimum velocity. It has also been pointed out that influent concentration lower than design concentration of pollutants, which is mainly caused by unidentified inflow and infiltration, degrades the operational efficiency of many sewage treatment plants (STPs). A computer-added analysis method supporting a coupled simulation of sewage quality and quantity is essentially required to evaluate the status of existing STPs and to improve their efficiency by a proper sewer rehabilitation work. In this study, dynamic water quality simulations were conducted using MOUSE TRAP to investigate the principal parameters that governs the changes of BOD, ${NH_4}^+$, and ${PO_4}^{3-}$3- concentrations within the sewer networks based on data acquired through on-site and laboratory measurements. The BOD, ${NH_4}^+$ and ${PO_4}^{3-}$3- concentrations estimated by MOUSE TRAP was lower than theoretical pollution loads because of sedimentation and decomposition in the sewer. The results revealed that sedimentation is a most important factor than other biological reactions in decreasing pollutant load in the sewers of C-city. The sensitivity analysis of parameters pertaining to water quality changes indicated that the effect of the BOD decay rate, the initial DO concentration, the half-saturation coefficient of dissolved BOD, and the initial sediment depth is marginal. However, the influence of settling rate and temperature is relatively high because sedimentation and precipitation, rather than biological degradation, are dominant processes that affect water quality in the study sewer systems.

Treatment of Fish Processing Wastewater Using Sequencing Batch Reactor (SBR) (연속회분식 반응기를 이용한 수산물 가공폐수 처리)

  • Paik, Byeong Cheon;Shin, Hang Sik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.1
    • /
    • pp.18-26
    • /
    • 1994
  • This research investigated efficient operation mode for the successful performance of SBR(sequencing batch reactor) treating fish processing wastewater, and the effect of sodium chloride (NaCl) on treatment efficiency. 2-hour-annerobic, 6-hour-aerobic and 3-hour-anoxic operation during reaction period was found an effective operating method for organic and nitrogen removal from fish processing wastewater in SBR system. The average removal efficiencies of COD, BOD, and total nitrogen in SBR operated continuousely were 91%, 95%, and 67.1%, respectively. The estimated values of biomass yield coefficient(Y), microbial decay coefficient($K_d$), and bioreaction rate constant(K) were $0.35gMLSS/gCOD_{removed}$, $0.015day^{-1}$, and $0.209hr^{-1}$, respectively. As NaCl concentration increased from 5 to 30g/L, sludge settleability was cnhanced but organic removal in the reactor was decreased. NaCl of influent had considerable relationship with COD removal, whereas it did not significant affect nitrogen removal.

  • PDF