A Study on the Characteristics of the Soysauce Wastewater Treatment in Aerobic Submerged Biofilter (간접포기식 침지여상의 장류 폐수처리특성에 관한 연구)

  • 권영호;원찬희;신승원
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.679-685
    • /
    • 1998
  • The Soysauce wastewater removal characteristics of submerged biofilters filled with two filter media respectively were experimentally examined with constant temperature, pH value and variable BOD loading and recirculation ratio. The decreasing order of BOD removal is Netring(random plastic media), cubic wire meshes(plastic module). This is mainly due to the media characteristics such as void ratio, specific surface area and media shapes. The BOD removal ratio decreases with increasing $BOD_5$/ volumetric loading rate, and the loading rate for the BOD removal over 85% is lower than 1.5kg$BOD_5$ 5/$m^3$d for the plastic media of Netring and cubic wire meshes. The $BOD_5$ removal rate increases with the recirculation ratio, but the rate of increase become smaller as the recirculation ratio increases over 20. When $BOD_5$ volumetric loading is 1.5kg$BOD_5$/$m^3$d, the required recirculation ratio to obtain 85% BOD$_{5}$ removal is about 20 for Netring and it was about 30 for cubic wire meshes.s.

  • PDF

The Distribution Characteristics of Organic Matters in the Contaminated Tributaries of Han River Region (한강권역 우심지류 하천의 유기물 분포 특성)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.5
    • /
    • pp.494-502
    • /
    • 2018
  • The purpose of this study was to understand distribution characteristics of organic matters through concentration of $BOD_5$, $COD_{Mn}$ and TOC in 31 streams in Han River region, and to establish the relationship among organic matter concentration, and discharge load and flow rate. Concentration of $BOD_5$ and TOC in 22 streams were above IV grade except 9, and the average 80.9 % of total organic matter (by TOC) accounted for dissolved organic type. Correlation among organic matter parameters were higher ($r^2$ > 0.78) and the relationship between TOC and $COD_{Mn}$ concentration was higher than $BOD_5$. Ratio of biodegradable organic matter/total organic matter in the 31 streams was estimated at 41.4 % with $BOD_5$ oxidation rate, and 78.0 % with $BOD_5/COD_{Mn}$ concentration ratio. Ratio of $NBOD/BOD_5$ concentration in four sites with $BOD_5/COD_{Mn}$ concentration ratio exceeding 1 ranged from 54.5 % ~ 79.3 %. Among 979 flow rate data measured at 31 streams, 87 % of measured data was below 0.1 cms and increased water pollution under low flow conditions. Correlation between $BOD_5$ concentration and $BOD_5$ discharge load in the watershed was low, and it was revealed that several streams have more $BOD_5$ delivery load than $BOD_5$ discharge load. Results suggest that many biodegradable forms of organic matter are being introduced into the stream from pollutant sources in the watershed.

Automatic On-line BOD Measurement System Using A Microbial Membrane Electrode (미생물막 전극을 이용한 BOD 자동화 측정장치)

  • Oh, Hyuk;Kim, Hai Dong
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.335-340
    • /
    • 1995
  • Automatic biochemical oxygen demand(BOD) measurement system has heen developed using a microbial membrane electrode, prepared from Bacillus subtilis and polyvinyl alcohol(PVA). The automatic BOD measurement system showed a linear response curve up to BOD 60 ppm using a glucose/glutamic acid standard solution, and all the BOD measurement processes are carried out automatically to calculate BOD whithin 10 min after each sample injection. The response times of the microbial electrode was 5 minutes with a 5 min recovery time between measurements and the relative error of the BOD estimation was within 10%.

  • PDF

Studies on the Effect of the Heavy Metals and CN on the $BOD_{5}$ Measurement (중금속 및 CN이 $BOD_{5}$ 측정에 미치는 영향)

  • 어수미;박성배
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.1
    • /
    • pp.74-78
    • /
    • 1991
  • This study was performed to investigate the effect of heavy metals and CN on BOD$_{5}$ measurement. The results were as follows: 1. The BOD$_{5}$ value decreased 20% in Cd(CdCl$_{2}$) 3.0mg/l, Ni(NiCl$_{2}$) 7.0mg/l, Cu(CuCl$_{2}$) 0.5mg/l, Pb($Pb(NO_{3})_{2}$) 9.0mg/l, Cr($K_{2}Cr_{2}O_{7}$) 1.0mg/l respectively. 2. The BOD$_{5}$ value decreased 10% in Zn($Zn(NO_{3})_{2}$) 5 mg/l, Fe(FeCl$_{3}$) 20mg, /l, and 25% in CN(KCN) 5mg/l, and 40% in Hg(HgCl$_{2}$) 0.2rng/l. 3. In Comparion with BOD Rapid Analyzer, the above mentioned heavy metals concentrations have no effect on BOD$_{5}$ value of that analyzer except CN.

  • PDF

A Study on the BOD Removal Characteristics of Aerobic Submerged Biofilter (Media를 충전(充塡)한 간접폭기식(間接曝氣式) 침지여상(浸漬濾床)에 의한 BOD제거 특성에 관한 연구)

  • Yang, Sang Hyun;Kwon, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.669-678
    • /
    • 1994
  • The BOD removal characteristics of submerged biofilters filled with three kinds of filter media respectively were experimentally examined with constant temperature, pH value and variable BOD loading and recirculation ratio. Obtained results are as follows; 1. The BOD removal ratio decreases with the increasing $BOD_5$ volumetric loading rate, and the loading rate for the BOD removal over 90% is lower thean $1.6kg{\cdot}BOD_5/m^3{\cdot}d$ for the plastic media of Netring and cubic wire meshes. This is a much large value than $0.3{\sim}0.8kg{\cdot}BOD_5/m^3{\cdot}d$ for conventional activated sludge process. The required submerged biofilter volume is found to be much samller than that of conventional activated sludge process. 2. The decreasing order of BOD removal is Netring (random plastic media), cubic wire meshes (plastic module), and then gravel (stone media). This is mainly due to the media characteristics such as void ratio, specific surface area and media shapes. 3. The $BOD_5$ removal rate increases with the recircuration ration, but the rate of increases becomes samaller as the recirculation ratio increases over 20. When $BOD_5$ loading is $1.8kg{\cdot}BOD_5/m^3{\cdot}d$, the required recirculation rationto obtain 90% $BOD_5$ removal is about 20 for Netring and it was about 30 for cubic wire meshes. 4. Reynold's Number increases with recirculation ratio, and the Reynold's Numbers corresponding to the recircuration ratio of 10~50 are less than 52, showing laminar up flows in the filter. The settled and effluent sludges increase with increase of Reynol's Number, and there are the definite Reynold's Numbers at which the settling sludge concentrations become nearly constant respectively in each filters. 5. In this submerged biofilter system, small volume of sludge hopper can be substituted for a separated settling tank.

  • PDF

Development of Assembly for Fast BOD Estimation and Its Applications (신속한 BOD 측정장치의 개발과 응용)

  • Soon, Moo-Jeong;Kim, Eun-Jeong;Jang, Seh-Yong;Hong, Daeil
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.285-291
    • /
    • 1994
  • A microbial BOD sensor for the continuous estimation of BOD was been developed by immobilizing Trichosporon cutaneum, which was immobilized between a dialysis and a gas-permeable membrane, on an oxygen electrode. The optimum pH and temperature for BOD measurement using this sensor were pH 7.0 and $32{\sim}33^{\circ}C$, respectively. The best result was obtained at 2~3ml/min flow rate in 0.1M phosphate buffer solution. A linear relationship was observed between ${\Delta}DO$ and the concentration of standard GGA solution below 60mg/l(90ppm $BOD_5$). The reproducibility was found to be within 3% for the standard solution containing glucose 30mg/l and glutamic acid 30mg/l. The output DO value of this sensor was almost constant for 30 dalys. The response time and the recovery time were about 5 and 10 min, respectively. This sensor was employed for the BOD measurement of waste pollutants and was compared with $BOD_5$ method.

  • PDF

Development and Evaluation of a Rapid BOD Measurement System (신속 BOD 측정장치의 개발 및 시험)

  • Oh, Hyuk;Choi, Don-Soo;Jeong, Hyuk;Choi, Ju-Hwan;Kim, Hai-Dong
    • Analytical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.146-152
    • /
    • 1997
  • A rapid BOD measurement system using a microbial membrane electrode has been developed. Culture of microorganism and the preparation of microbial membrane, the effect of sample flow rate on the BOD measurement, the effect of solution pH and response characteristics of the microbial membrane electrode were investigated. The rapid BOD measurement system developed by us was connected to a personal computer and the whole BOD measurement procedures were carried out automatically. The best results were obtained when the solution flow rate was 7.8mL/min and the data were obtained 5 minutes after sample injection.

  • PDF

Organophosphorus Insecticide Residues in Fruits and Vegetables (과실 채소중 잔류농약(유기인제)에 관한 연구)

  • 윤숙자
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.83-92
    • /
    • 1990
  • Adapting two step aeration system to a waste water treatment of W-paper manufactory as Full-Scale Plants, we drew a following conclusion from its practical working. 1. Because BOD removal efficiency was 20% in A-Stage, 90% in B-Stage and total removal efficiency was 97%. It worked treatment plant well and was suitable for effluent water standard as well. Because COD removal efficiency was 42% in A-stage, 71% in B-stage and the total removal efficiency was 94% COD control was possible in effluent water quality. 2. Treatment efficiency according to a load capacity was average 20% in 1.401 BOD kg/m3/d load of A-Stage and average 90% in 0.273 BOD kg/$\textrm {m}^3$ / d load of B-Stage. 3. Treatment efficiency according to a ratio of F/M was 2.657--5.024 kg BOD/kg MLSS/d in A-Stage and BOD removal efficiency was 16-261 in the same stage. The ratio of F/M was 0.068-0.094 kg BOD /kg MLSS/d and BOD removal efficiency ratio was 85-94%. Therefore treatment efficiency could be kept stably and volume of aeration tank could be reduced wholly. 4. Treatment efficiency according to MLSS appeared BOD 20%. COD 42%, in A-Stage and removal efficiency appeared BOD 90%, COD 71% in B-Stage. They were suitable for plan condition. 5. Because of working of complemented treatment plant by AB-Process. 20,000,000 Won a month was saved than the ordinary working cost. Therefore, it was assumed that invested cost could be recollected in 19 months or so consequently.

  • PDF

Evaluation of Water Quality with BOD at Mankyeong and Dongjin River Basins (만경강 및 동진강 수계의 BOD에 의한 수질 평가)

  • Lee, Jong-Sik;Jung, Goo-Bok;Kim, Jin-Ho;Yun, Sun-Gang;Kim, won-Il;Shin, Jung-Du
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.2
    • /
    • pp.81-84
    • /
    • 2004
  • Biological oxygen demand (BOD) as a stream water quality indicator was monitored monthly in the Mankyeong and Dongjin river basins from June 2001 to October 2002 to evaluate water qualitied as well as to get the information on the water quality management strategy in Semangeum reclamation areas. BOD in the Mankyeong river was 5.4mg/L in average during the survey and increased after the inflow of Iksan tributary, which was contaminated with livestock wastewater. BOD of Iksan tributary was maintained at 5.4 mg/L before joining the Wanggung tributary, however, that in the downstream was increased to 13.6 mg/L in average due to the inlet of the livestock wastewater. Meanwhile, BOD of Dongjin river was the average of 2.8 mg/L during the survey periods but it showed 3.5 mg/L when Jungeup tributary which was contaminated with sewage and industrial wastewater joined into the main stream. BOD in both Mankyeong and Dongjin rivers decreased in 2002 as compared to that in 2001.

Analysis of Hydrologic Cycle and BOD Loads Using HSPF in the Anyancheon Watershed (HSPF 모형을 이용한 안양천 유역의 물순환 및 BOD 부하량 분석)

  • Lee, Kil-Seong;Chung, Eun-Sung;Lee, Joon-Seok;Hong, Won-Pyo
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.8
    • /
    • pp.585-600
    • /
    • 2007
  • The hydrologic cycle and BOD pollutant loads of all sub-watersheds were analyzed using HSPF (Hydrological Simulation Program-Fortran). At first, sensitivity analyses to water quantity (peak discharge and total volume) and quality (BOD peak concentrations and total loads) were conducted and some critical Parameters were selected. For more precise simulation, the study watershed was divided into four parts according to the landuse characteristics and used climate data and so calibrated and verified respectively. It was found that as the urban area ratio increases in the downstream direction, baseflow decreases (11.1 % $\rightarrow$ 5.0%) and the ratio of direct runoff volume(42.5 % $\rightarrow$ 56.9 %), BOD concentration (3.3 mg/L $\rightarrow$ 15.0 mg/L) and unit loads (55.4 kg/ha/year $\rightarrow$ 354.5 kg/ha/year) increase.