• Title/Summary/Keyword: BO $D_{5}$

Search Result 559, Processing Time 0.028 seconds

Investigation of Automated Neonatal Hearing Screening for Early Detection of Childhood Hearing Impairment (소아 난청의 조기진단을 위한 신생아 청력 선별검사에 대한 평가)

  • Seo, Jeong Il;Yoo, Si Uk;Gong, Sung Hyeon;Hwang, Gwang Su;Lee, Hyeon Jung;Kim, Joong Pyo;Choi, Hyeon;Lee, Bo Young;Mok, Ji Sun
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.7
    • /
    • pp.706-710
    • /
    • 2005
  • Purpose : Early diagnosis of congenital hearing loss through the neonatal hearing screening test minimizes language defect. This research intends to identify frequency of congenital hearing loss in infants through neonatal hearing screening test with the aim of communicating the importance of hearing test for infants. Methods : From May 20, 2003 to May 19, 2004, infants were subjected to Automated Auditory Brainstem Response test during one month of birth to conduct the test with 35 dB sound. Infants who passed the 1st round of hearing test, were classified into 'pass' group whereas those who did not were classified into 'refer' group. Infants who did not 'pass' in the hearing test conducted within one month of birth were subjected to re-test one month later, and if classified as 'refer' during the re-test, they were subjected to the diagnosis for validation of hearing loss by requesting test to the hearing loss clinic. Results : There was no difference among the 'pass' and 'refer' group in terms of form of childbirth, weight at birth and gestational age. In the 1st test, total of 45 infants were classified into 'refer' group. Six among 35 who were subjected to re-test(17%) did not pass the re-test, and all were diagnosed with congenital hearing loss. This corresponds to 0.35%(3.5 per 1,000) among total number of 1,718 subjects. Conclusion : In our study the congenital hearing loss tends to be considerably more frequently than congenital metabolic disorder. Accordingly, newly born infants are strongly recommended to undergo neonatal hearing screening test.

Numerical Simulation of CNTs Based Solid State Hydrogen Storage System (탄소나노튜브 기반의 고체수소저장시스템에 관한 전산해석)

  • Kim, Sang-Gon;HwangBo, Chi-Hyung;Yu, Chul Hee;Nahm, Kee-Suk;Im, Yeon-Ho
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.644-651
    • /
    • 2011
  • Storing hydrogen in solid state hydride is one of the best promising methods for the future hydrogen economy. The total performance of such systems depends on the rate at which the amount of mass and heat migration is supplied to solid hydride. Therefore, an accurate modeling of the heat and mass transfer is of prime importance in optimizing the design of such systems. In this work, Hydrogen storage in Pt-CNTs hydrogen reactor has been intensively investigated by solving 2 dimensional mathematical models. Using a CFD computer software, systematic studies have been performed to elucidate the effect of heat and mass transfer during hydrogen charging periods. It was revealed that the optimized design of hydrogen storage vessel can prevent the increase of system temperature and the charging time due to the convective cooling effects inside the vessels at even high charging pressure. Because none has reported the critical issues of heat and mass transfer for CNT based hydrogen storage system, this work can support the first insight of the optimal design for solid state hydrogen storage system based on CNT in the near future.

Kinematic Analysis in Reaching Depending on the Localized Vibration Duration in Persons With Hemiparetic Stroke (국소 진동자극이 편마비 뇌졸중 환자의 팔 뻗기 수행에 미치는 영향에 대한 운동학적 분석)

  • Yoo, Eun-Young;Park, Ji-Hyuk;Kwon, Jae-Sung;Cho, Sang-Yoon;Lee, Bo-Mi;Kim, Yeong-Jo;Kim, Jae-Nam;Kim, Sun-Ho
    • Therapeutic Science for Rehabilitation
    • /
    • v.7 no.3
    • /
    • pp.79-88
    • /
    • 2018
  • Objective : Localized vibration has been shown to have a positive effect on recovery of upper-limb motor function in patients with hemiparetic stroke, but there has been little research on kinematic analysis for qualitative changes in movement. This study investigated kinematic changes in elbow motion during reaching after localized vibration in persons with hemiparetic stroke. Methods : This study used a one-group, cross-over trial design. Ten chronic stroke patients randomly received localized vibrations on the affected biceps brachii for 5, 10, or 20 min, at 70 Hz. Kinematic analysis of reaching was measured using a 3-D motion analysis system. Variables included peak angular velocity, time to peak angular velocity, and movement units during elbow motion. Result : Affected side elbow motion during reaching was faster, smoother, and more efficient after 20 min localized vibration. Peak angular velocity increased (p<0.05), and time to peak angular velocity (p<0.05) and the movement unit were significantly decreased (p<0.05) during elbow motion for reaching. Conclusion : Localized vibration can improve kinematic components during reaching motion in persons with hemiparetic stroke.

Key Bit-dependent Attack on Side-Channel Analysis-Resistant Hardware Binary Scalar Multiplication Algorithm using a Single-Trace (부채널 분석에 안전한 하드웨어 이진 스칼라 곱셈 알고리즘에 대한 단일 파형 비밀 키 비트 종속 공격)

  • Sim, Bo-Yeon;Kang, Junki;Han, Dong-Guk
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.28 no.5
    • /
    • pp.1079-1087
    • /
    • 2018
  • Binary scalar multiplication which is the main operation of elliptic curve cryptography is vulnerable to the side-channel analysis. Especially, it is vulnerable to the side-channel analysis which uses power consumption and electromagnetic emission patterns. Thus, various countermeasures have been studied. However, they have focused on eliminating patterns of data dependent branches, statistical characteristic according to intermediate values, or the interrelationships between data. No countermeasure have been taken into account for the secure design of the key bit check phase, although the secret scalar bits are directly loaded during that phase. Therefore, in this paper, we demonstrate that we can extract secret scalar bits with 100% success rate using a single power or a single electromagnetic trace by performing key bit-dependent attack on hardware implementation of binary scalar multiplication algorithm. Experiments are focused on the $Montgomery-L{\acute{o}}pez-Dahab$ ladder algorithm protected by scalar randomization. Our attack does not require sophisticated pre-processing and can defeat existing countermeasures using a single-trace. As a result, we propose a countermeasure and suggest that it should be applied.

Quality Characteristics of Seasoned Skewered Chicken Added with Fermented Carrot Juice (당근발효액 첨가에 따른 닭꼬치의 품질 특성)

  • Kim, Hyun-Jeong;HwangBo, Mi-Hyang;Hwang, Eun-Young;Jung, Young-Tae;Park, Soo-Kyoung;Lee, Sam-Pin;Lee, In-Seon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.8
    • /
    • pp.1097-1103
    • /
    • 2009
  • This study was conducted to evaluate the quality characteristics of seasoned skewered chicken added with fermented carrot juice (FCJ) during storage at $4^{\circ}C$ for 21 days. The carrot juice was fermented using 2% Leuconostoc mesenteroides SM at $25^{\circ}C$ for 18$\sim$20 hr. Seasoned skewered chicken was produced containing 0, 5% and 10% FCJ. The pH and color values of seasoned skewered chicken were decreased with longer storage periods, while the VBN content was increased during storage. Bacteria was not detected in seasoned skewered chicken containing FCJ. The saturated fatty acid in seasoned skewered chicken decreased with increasing additions of FCJ, whereas the unsaturated fatty acid was increased compared to the control. The texture, resilience, springiness, cohesiveness and chewiness of seasoned skewered chicken were not significantly different, while the hardness of seasoned skewered chicken added with 10% FCJ was significantly the lowest (p<0.05). With regard to sensory evaluation, seasoned skewered chicken added with 10% FCJ resulted in higher overall acceptability than other skewered chickens. These results suggest that manufacture of seasoned skewered chicken added with FCJ can help to improve quality of skewered chicken.

Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy (골(骨)스캔을 이용(利用)한 천장관절(薦腸關節)/천골섭취비(薦骨攝取比)의 정량적(定量的) 측정(測定))

  • Lee, Young-Yiul;Park, Seon-Yang;Lee, Myung-Chul;Choi, Sung-Jae;Cho, Bo-Youn;Choe, Kang-Won;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.16 no.2
    • /
    • pp.63-70
    • /
    • 1982
  • To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio(SIS Ratio) by region of interest(ROI) method using $^{99m}Tc-methylene$ diphosphonate. The observed results were as follows: 1. Using ROI method, the SIS ratios for the control group of 65 persons were $1.05{\pm}0.08$(left) and $1.06{\pm}0.07$(right) which were narrower in range than those of slice method $(mean{\pm}S.D.)$. 2. The effects of age, gender and laterality on SIS ratio were not significant. 3. In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4. In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who had no evidence of sacroiliitis clinically was within normal limit. 5. In 6 patients with ankylosing spondylitis in both sacroiliac joints, 4 whose pelvis A-P Xray findings showed severe sclerotic change of sacroiliac joints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6. 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded that quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  • PDF

Hydrophobic Cyclodextrin Derivatives as a Sustained Release Carrier of Azidothymidine (아지도싸이미딘의 지속성방출형담체로서의 소수성시클로덱스트린유도체)

  • Seo, Bo-Youn;Park, Gee-Bae;Lee, Kwang-Pyo
    • Journal of Pharmaceutical Investigation
    • /
    • v.26 no.2
    • /
    • pp.71-82
    • /
    • 1996
  • This study has been undertaken to evaluate hydrophobic cyclodextrin(CD) derivatives as a sustained release carrier of azidothymidine(AZT), AZT, which has potent activity against AIDS and AIDS-related complex as thymidine analogue, has been reported that it has significant toxicity and short half life. Therefore, it is necessary to design sustained release oral dosage form to avoid undesirable side effects attributable to an excessive plasma concentration and to reduce the frequency of administration of AZT. Inclusion complexes of AZT with $acetyl-{\beta}-cyclodextrin\;(AC{\beta}CD)$ and $triacetyl-{\beta}-cyclodextrin(TA{\beta}CD)$ were prepared by solvent evaporation method. Interactions of AZT with CD were investigated by Differential Scanning Calorimetry(DSC) and Infrared Spectrophotometry(IR). The decreasing order of water solubilities of AZT and AZT-CD inclusion complexes were as follows; $AZT\;(27.873{\pm}0.015,mg/ml)\;>\;AZT-AC{\beta}CD\;(3.377{\pm}0.003)\;>\;AZT-TA{\beta}CD\;(2.528{\pm}0.001)$. Partition coefficients of $AZT-AC{\beta}CD\;and;\AZT-TA{\beta}CD$ inclusion complexes were increased by 1.27-fold, 1.54-fold in pH 1.2 and 1.32-fold, 1.47-fold in pH 6.8 in comparison with that of AZT. The mean dissolution time (MDT, min) which represents the rapidity of dissolution rate of AZT, $AZT-AC{\beta}CD,\;AZT-TA{\beta}CD$ were 5.12, 14.02 and 19.38 min in pH 1.2 and 2.52, 15.19 and 18.19 min in pH 6.8. AZT was very rapidly and completely dissolved in pH 1.2 and pH 6.8 within 5 minutes. But AZT-CD inclusion complexes showed the sustained release pattern in comparison with AZT alone. The simultaneous in situ nasal and jejunal recirculation study to compare the intrinsic absorptivity and the property of absorption sites revealed that the absorption of $AZT-TA{\beta}CD\;(N:35.35{\pm}1.08%,\;J:27.47{\pm}1.18%)$ was more than that of $AZT\;(N:16.89{\pm}2.25%,\;J:15.86{\pm}2.33%)$. The above results suggest that $TA{\beta}CD$ which is a hydrophobic cyclodextrin may serve as sustained release carrier with absorption enhancing effect.

  • PDF

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

Characterization of Summertime Aerosol Particles Collected at Subway Stations in Seoul, Korea Using Low-Z Particle Electron Probe X-ray Microanalysis

  • Kim, Bo-Wha;Jung, Hae-Jin;Song, Young-Chul;Lee, Mi-Jung;Kim, Hye-Kyeong;Kim, Jo-Chun;Sohn, Jong-Ryeul;Ro, Chul-Un
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.97-105
    • /
    • 2010
  • A quantitative single particle analytical technique, denoted low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA), was applied to characterize particulate matters collected at two underground subway stations, Jegidong and Yangje stations, in Seoul, Korea. To clearly identify the source of the indoor aerosols in the subway stations, four sets of samples were collected at four different locations within the subway stations: in the tunnel; at the platform; near the ticket office; nearby outdoors. Aerosol samples collected on stages 2 and 3 ($D_p$: $10-2.5\;{\mu}m$ and $2.5-1.0\;{\mu}m$, respectively) in a 3-stage Dekati $PM_{10}$ impactor were investigated. Samples were collected during summertime in 2009. The major chemical species observed in the subway particle samples were Fe-containing, carbonaceous, and soil-derived particles, and secondary aerosols such as nitrates and sulfates. Among them, Fe-containing particles were the most popular. The tunnel samples contained 85-88% of Fe-containing particles, with the abundance of Fe-containing particles decreasing as the distances of sampling locations from the tunnel increased. The Fe-containing subway particles were generated mainly from mechanical wear and friction processes at rail-wheel-brake interfaces. Carbonaceous, soil-derived, and secondary nitrate and/or sulfate particles observed in the underground subway particles likely flowed in from the outdoor environment by human activities and the air-exchange between the subway system and the outdoors. In addition, since the platform screen doors (PSDs) limit air-mixing between the tunnel and the platform, samples collected at the platform at the Yangjae station (with PSDs) showed a marked decrease in the relative abundances of Fe-containing particles compared to the Jegidong station (without PSDs).

Chemical Changes of Red Pepper Seasoning Oil during Storage (고추향미유의 저장 중 화학적 특성 변화)

  • Yang Jong-Beom;Ko Myung-Soo;Lee Keun-Bo;Kim Kwang-Soo;Moon Yoon-Hee
    • Food Science and Preservation
    • /
    • v.13 no.3
    • /
    • pp.310-315
    • /
    • 2006
  • Chemical characteristics of red pepper seasoning oil were investigated during storage at $65^{\circ}\C$ for 6 week to obtain information fer the quality control of powdered soups of Korean instant noodles. The acid value increased gradually during storage. The peroxide value increased remarkably at 4 weeks of storage, but decreased at 6 week of storage. Both American Spice Trade Association (ASTA) value that indicates redness of red pepper and the CIE $L^*,\;a^*,\;and\;b^*$ value increased to 4 weeks of storage, but decreased at 6 weeks of storage. The fatty acids were mainly composed of linoleic (51.02%), oleic (30.17%), and palmitic (11.81%) acid Myristic and palmitic acid content increased slightly but linoleic acid decreased during storage. The ratio of total unsaturated fatty acids to total saturated fatty acids slightly decreased during storage. In free fatty acid (FFA) composition, linoleic acid was present in the greatest amount but it decreased remarkably from 85.5 to 65.2 (mg/kg oil) after 6 weeks of storage. Total amount of FFA increased throughout the storage period. The ratio of total free unsaturated fatty acids to total free saturated fatty acids decreased during storage.