• Title/Summary/Keyword: BIOMECHANICAL

Search Result 959, Processing Time 0.027 seconds

Comparison of Biomechanical Factors on Badminton shoes between Anti-slip outsole and Non anti-slip outsole (배드민턴화의 미끄럼방지 아웃솔 부착 유무에 따른 생체역학적 요인 패턴비교)

  • Yi, Jae-Hoon;Jang, Young-Kwan;Hah, Chong-Ku;Ki, Jae Sug
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.153-160
    • /
    • 2013
  • The purpose of this study was to compare biomechanical factors on badminton shoes between anti-slip outsole and non anti-slip outsole. Six subjects participated in this experiment. For three-dimensional analysis, eight cameras (Oqus 3series, Qualisys) were used to acquire raw data, and then the parameters were calculated and analyzed with Visual-3D. In conclusion, the patterns of spent time during side step, and maximum velocities of CoGs were consistent without joint angles of lower extremities in spite of small differences. Those of GRFs, and moment of lower extremities were absolutely consistent. This trend of biomechanical factors was that Y shoe (ante-treatment) was much greater and PS shoe (treatment) was greater than Y shoe (treatment). (That was, Y shoe (ante-treatment) > PS shoe (treatment) >Y shoe (treatment)). The findings of this study showed that anti-slip outsole was effective and brought increasing performance and decreasing injuries. It is suggested that further study of these phenomena will help understand many aspects of human locomotion, including work, performance, fatigue and possible injuries.

Biomechanical Evaluation of a Manual Wheelchair with Forward. Reverse Propulsion (정.역 구동 방식 수도 휠체어의 인체공학적 성능 분석)

  • Shin, Eung-Soo;Lee, Hee-Tae;Ahn, Seong-Chul
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.464-469
    • /
    • 2001
  • This work provides the biomechanical evaluations of a manual wheelchair with a bi-directional driving system. The new propulsion strategy can be accomplished by employing a special gear system that converts the oscillatory motion of a handrim into the unidirectional output motion of a wheel. A main feature of the forward. backward propulsion is to supply continuous driving torque without break. Motion. analysis has been performed through 2-dimensional image processing for measuring the kinematic properties of the upper arm and fore arm. Then, the inverse dynamics analysis has been done for obtaining the joint torques, the handrim forces and input/output powers. Results show that the output power by the forward. reverse propulsion is almost twice as much as that by conventional propulsion. Also, the new propulsion is expected to reduce the fatigues and injuries at arm joints by employing more muscle groups for movement. In conclusion, the forward. reverse propulsion can greatly improve the performances of manual wheelchairs by providing better mobility as well as by guaranteeing several advantages from a biomechanical viewpoint. Future development of a manual wheelchair optimized for the bi-directional propulsion will further improve the propulsion performances.

  • PDF

The role of research in the creation of athletic footwear

  • Lafortune, Mario A.
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.407-415
    • /
    • 2002
  • Athletic products must meet the needs of athletes and the demands imposed by sports through innovative design. These needs of athletes and requirements of sports are performance, protection and comfort related. In depth knowledge of anatomy and physiology, etiology of commonly reported injuries, and lower extremity mechanics form the basis of product creation/engineering. Game analysis which entails time and frequency surveys of the skills performed during a game, interviews with athletes and coaches, and discussions with medical staffs are used to identify the skills that are critical to the needs of athletes. In lab full biomechanical analyses of these skills and/or physiological responses of the athletes lead to clear functional criterions that serve as guidelines to be met by the design team. The concepts created by the design team are in turns subjected to the same battery of biomechanical analyses. The learning gathered through this pluridisciplinary process is used to further evolve design concepts. The evolution-testing loop is repeated until biomechanical and/or physiological, mechanical and perceptual tests indicate that the design concept meets the established functional design criterions. At that time, the design concepts is ready for manufacturing research and development. Additional biomechanical and physical tests are performed through that phase to confirm that the manufacturing processes preserve the functionality of the design concept. Durability and long term performance of production samples are evaluated through a final three month long weartest program. A rigorous research/testing program is crucial to create and engineer sport products that meet the performance, protection.

Biomechanical Effect of Total Disc Replacement on Lumbar Spinal Segment : A Finite Element Analysis (추간판 치환술이 요추분절에 미치는 생체역학적 영향 : 유한요소해석)

  • Park, Won-Man;Kim, Ki-Tack;Hong, Gyu-Pyo;Kim, Yoon-Hyuk;Oh, Taek-Yul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.13 no.1
    • /
    • pp.58-66
    • /
    • 2008
  • The artificial discs have recently used to preserve the motion of the treated segment in lumbar spine surgery. However, there have been lack of biomechanical information of the artificial discs to explain current clinical controversies such as long-term results of implant wear and excessive facet contact forces. In this study, we investigated the biomechanical effects of three artificial implants on the lumbar spinal segments by finite element analysis. The finite element model of intact lumbar spine(L1-S) was developed and the three implants were inserted in L4-L5 segment of the spine model. 5 Nm of flexion and extension moments were applied on the superior plate of L1 with 400 N of compressive load. Excessive motions and high facet contact forces at the surgical level were generated in the all three implanted models. In the flexion, the peak von-Mises stresses in the semi-constrained type implant was higher than those in the un-constrained type implant which would cause wear on the polyethylene core. The results of the study would provide a biomechanical guideline for selecting optimal surgical approach or evaluating the current design of the implants, or developing a new implant.

Biomechanical Analysis on the Shift of Gravity Line in Hemiplegic Patients (편마비환자의 중력선 이동에 따른 역학적 분석)

  • Lee Hea-Young;Jeong Dong-Hoon;Park Rae-Joon;Kim Jin-Sang
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.1
    • /
    • pp.63-70
    • /
    • 1999
  • This study was for mathematical method of calculating the joint reaction force during on single - leg stance on a normal and hemiplegic patients. It is important to compare the distance of the line of gravity from the hip joint on hemiplegic patients with this on normal in this study. In earlier studies, there is no include the concept about biomechanical analysis on the shin of line of gravity of hemiplegic patients. Though this concept, we found the compensation make the line of gravity closer to the supporting hip joint and the trunk was toward the side of paralysis. The result of the Joint reaction force on hemiplegic patients is found to be approximately $31.33\%$ in the unaffected side by biomechanical analysis.

  • PDF

Biomechanical Characterization with Inverse FE Model Parameter Estimation: Macro and Micro Applications (유한요소 모델 변수의 역 추정법을 이용한 생체의 물성 규명)

  • Ahn, Bum-Mo;Kim, Yeong-Jin;Shin, Jennifer H.;Kim, Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1202-1208
    • /
    • 2009
  • An inverse finite element (FE) model parameter estimation algorithm can be used to characterize mechanical properties of biological tissues. Using this algorithm, we can consider the influence of material nonlinearity, contact mechanics, complex boundary conditions, and geometrical constraints in the modeling. In this study, biomechanical experiments on macro and micro samples are conducted and characterized with the developed algorithm. Macro scale experiments were performed to measure the force response of porcine livers against mechanical loadings using one-dimensional indentation device. The force response of the human liver cancer cells was also measured by the atomic force microscope (AFM). The mechanical behavior of porcine livers (macro) and human liver cancer cells (micro) were characterized with the algorithm via hyperelastic and linear viscoelastic models. The developed models are suitable for computing accurate reaction force on tools and deformation of biomechanical tissues.

Comparison of Lifting and Lowering Activity based on Biomechanical, Physiological, Psychophysical Criteria (들기 작업과 내리기 작업의 생체역학적, 생리학적, 정신물리학적 기준치에 의한 비교)

  • Kim, Hong-Ki
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.145-153
    • /
    • 2010
  • Activity of lifting has been a major issue in many research area related in manual materials handling tasks. However, the opposite activity of lifting, lowering, has received much less attention. It is known that 52% of all box-handling tasks were lowering in nature. The difference in stress between lifting and lowering activity is not well understood. A simple assumption that these two activities are very similar has been established and widely used. However, this simple assumption may be questionable. The objective of this study was to compare a lifting activity and a lowering activity based on the three different ergonomic approaches; (1) biomechanical, (2) physiological, (3) psychophysical approach. It was found that the stress of lowering activity was from 65% to 93%, from 87% to 97%, and from 87% to 96% according to the biomechanical, physiological, and psychophysical point of view, respectively. It is concluded from the result of this study that the stress of lowering activity is lower than that of the lifting activity. The maximum compressive force on the lumbro-sacral joint (L5/S1) was 158% and 108% respectively, for lifting and lowering activity of which the work load is the 58% of Action Limit. It is suggested that the NIOSH AL and RWL and biomechanical criteria should be reconsidered especially for the low frequency of lifting activities.