• Title/Summary/Keyword: BIC%

Search Result 210, Processing Time 0.029 seconds

A histomorphometric study of dental implants with different surface characteristics

  • Pak, Hyun-Soon;Yeo, In-Sung;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.142-147
    • /
    • 2010
  • PURPOSE. One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared. MATERIALS AND METHODS. Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing. RESULTS. Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks. CONCLUSION. The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn't make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.

UA Study on the Polarization Selective Antenna for UHF RFID System (UHF RFID 시스템을 위한 Polarization selective 안테나 연구)

  • Lee, Sa-Won;Song, Woo-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.7
    • /
    • pp.67-74
    • /
    • 2010
  • TIn this paper, it is designed the polarization selective antenna for UHF RFID system. The proposed antenna is consist of microstrip patch antenna with dual feeding and two SPDT switches and a SP4T switch and 3dB hybrid coupler. Through control of voltage of switches, the proposed reader antenna can select horizontally linear polarization, vertically linear polarization, left-hand circular polarization (LHCP) and right hand circular polarization (RHCP). The proposed reader antenna satisfied 2:1 VSWR at 902MHz~928MHz. and it has under 3dB AR(axial ratio). Peak gain of antenna is 7.71dBi, 7.55dBi with linear polarization and 7.31dBic, 7.81dBic with circular polarization at x-y plane. Also Axial ratio of antenna is 2.01~2.83dB and 2.02~2.60dB respectively. It is satisfied 3dB axial ratio.

Study of the re-osseointegration of implant fixture after mechanical unscrewing (임플란트 고정체의 의원성 동요 후 골 유착 반응에 관한 연구)

  • Jang, Ji-Hoon;Cho, Jin-Hyun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.209-214
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate whether the re-osseointegration of the implants that had mechanical unscrewing possibly occurred or not. Furthermore, if it happened, the degree of re-osseointegration was evaluated by comparing with previous osseointegration. Materials and methods: The smooth implant (commercial pure titanium 99%) specimens, whose diameter and length was 3.75 mm, 4 mm, respectively were produced. Two implants were inserted into each tibia of 7 New Zealand female white rabbits weighing at least 3.0 kg. The torque removal force for each implant after 6 weeks of implants placement was measured and included in group I. The torque removal forces were assessed after the fixtures were re-screwed to original position and the subjects were allowed to have 4 more weeks for healing and included in group II. One rabbit was sacrificed after first measurement and produced 4 slide specimens in group I, and two rabbits were sacrificed after 2nd measurement, 7 slide specimens, in group II for histomorphologic investigations. All slide specimens were assessed based on the proportion of BIC (bone-implant contact) as well as CBa (Bone area in the cortical passage) value produced by counting the screw threads embedded in the compact bones under the optical microscopic analysis (${\times}20$). Statistical analysis was conducted to evaluate the torque removal force, BIC and CBa between group I and II. Results: As for the torque removal force, the result was $10.8{\pm}3.6$ Ncm for group I and $20.2{\pm}9.7$ Ncm for group II. Furthermore, the torque removal force of group II increased by 98.1% in average compared to group I (P<.05). On the other hand, histomorphologic analysis displayed that there was no statistical significance in BIC and CBa values between group I and the group II (P>.05), and RT/BIC and RT/CBa between group I and group II were statistically significant (P<.05). Conclusion: It is possible to obtain more substantial re-osseointegration within shorter periods than the period needed for the initial osseointegration in case of iatrogenically unscrewed implants.

Optimization of Aconitine Production in Suspension Cell Cultures of Aconitum napellus L.

  • Hwang, Sung-Jin;Kim, Yun-Hee;Pyo, Byoung-Sik
    • Korean Journal of Medicinal Crop Science
    • /
    • v.12 no.5
    • /
    • pp.366-371
    • /
    • 2004
  • Aconitine alkaloids produced from cell suspension cultures of Aconitum napellus for the first time. The effects of various culture conditions on cell biomass and aconitine accumulation in cell suspension cultures were investigated. Suspension cell cultures of A. napellus were established by transferring callus tissues from leaf explants onto liquid MS medium supplemented with $1\;mg/l$ NAA and $0.1\;mg/l$ kinetin. Among the culture media tested, MS medium had a pronounced effect on cell growth and aconitine accumulation. The maximum dry cell weight was obtained at inoculum size of 3 g (FCW) per flask and in MS medium supplemented with 5% sucrose after 8 weeks. The addition of salicylic acid (SA) and yeast extract (YE) in the MS medium enhanced aconitine accumulation. Using a proper combination of culture condition and supplements, aconitine content could reach 0.043% (dry weight basis), that was $2.5{\sim}3$ fold higher that detected in control cultures.

Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases

  • Jeong, Kyung-In;Kim, Young-Kyun;Moon, Sang-Woon;Kim, Su-Gwan;Lim, Sung-Chul;Yun, Pil-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.42 no.1
    • /
    • pp.38-42
    • /
    • 2016
  • The purpose of this study is to evaluate the degree of osseointegration of resorbable blasting media (RBM) surface implants retrieved from humans. Three implants in the mandibular molar region that were surface-treated with RBM were retrieved from two patients. The implants were used to manufacture specimens in order to measure the bone-implant contact (BIC) ratio. The BIC ratios of the three implants were found to be an average of $69.0%{\pm}9.1%$. In conclusion, that RBM surface implants are integrated into the host environment with histological significance and the BIC ratio of the RBM surface-treated implant was not significantly different from that of other surface-treated implants.

Experimental study about the bony healing of hydroxyapatite coating implants (수산화인회석 코팅 임프란트의 골치유과정에 관한 실험적 연구)

  • Eom, Tae-Gwan;Kim, Jong-Hwa;Cho, In-Hee;Jeong, Chang-Mo;Cho, Yong-Seok;Kim, Young-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.295-300
    • /
    • 2011
  • Introduction: Hydroxyapatite(HA) coating implant can accelerate osseointegration, however, there are many controversies. Materials and Methods: This study examined the early osseointegration of two types of hydroxyapatite coated implants. Twelve adult male miniature pigs (Medi Kinetics Micropigs, Medi Kinetics Co., Ltd., Busan, Korea) were used in this study. In the implants placed in the mandible, a histomorphometric evaluation was performed to evaluate the bone-implant contact (BIC) ratio. Results: The BIC ratio increased with time. TS III HA and Zimmer HA were not significantly different (P>0.05). At 8 weeks, the BIC of Zimmer HA was higher than TS III HA, but there was no significant difference (P>0.05). Conclusion: HA coated implants will accelerate early osseointegration.

Banded vector heterogeneous autoregression models (밴드구조 VHAR 모형)

  • Sangtae Kim;Changryong Baek
    • The Korean Journal of Applied Statistics
    • /
    • v.36 no.6
    • /
    • pp.529-545
    • /
    • 2023
  • This paper introduces the Banded-VHAR model suitable for high-dimensional long-memory time series with band structure. The Banded-VHAR model has nonignorable correlations only with adjacent dimensions due to data features, for example, geographical information. Row-wise estimation method is adapted for fast computation. Also, two estimation methods, namely BIC and ratio methods, are proposed to estimate the width of band. We demonstrate asymptotic consistency of our proposed estimation methods through simulation study. Real data applications to pm2.5 and apartment trading volume substantiate that our Banded-VHAR model outperforms traditional sparse VHAR model in forecasting and easy to interpret model coefficients.

Effects of electrical stimulation on healing of endo-osseous titanium implants in circumferential defect (전기자극이 성견 골결손부에 매식된 임플란트 주위조직의 치유에 미치는 영향)

  • Shim, Jae-Chang;Kim, Young-Jun;Chung, Hyun-Ju;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.177-193
    • /
    • 2004
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggested that electrical currents promote osseointegration around dental implants. The purpose of this study was to determine the effect of direct microcurrent to endosseous titanium implants placed in bone defects. The right and left 2nd, 3rd and 4th mandibular premolars in ten mongrel dogs (15Kg of weight) were extracted. One monthe later, Ti-machined screw type implants(3.8 mm diameter x 8.5 mm length, $AVANA^{(R)}$, Ostem) were placed in surgically created circumferential defect area(width 5mm, depth 4mm). The implants were divided into three groups according to the treatment modalities: Control group- implants without electrical stimulation; Experimental group I- implants with allogenic demineralized freeze dried bone grafting; and Experimental group II-implants allogenic demineralized freeze dried bone grafting and electric stimulation. The animals were sacrificed in the 4th and 8th week after implant placement and un-decalcified specimens were prepared for histological and histometrical evaluation of bone-implant contact ratio (BIC) and bone formation area ratio (BFA) in defect area. Some specimens at 8 weeks after implantation were used for removal torque testing. Histologically, there was connective tissue infiltration in the coronal part of defect area in control and the experimental group I, whereas direct bone contact was found in the experimental group II without connective tissue invasion. Average BIC ratios at 4 weeks of healing were 60.1% in the experimental group II, 47.4% in the experimental group I and 42.7% in the control. Average BIC ratios at 8 weeks after implantation were 67.6% in the experimental group II, 55.9% in the experimental group I and 54.6% in the control. The average BFA ratio was 84.0% in the experimental group II, 71.8% in the experimental group I and 58.8% in the control at 4 weeks, and the BFA ratios were 89.6% in the experimental group II, 81.4% in the experimental group I and 70.5% in the control at 8 weeks after implantation. The experimental group II showed also significantly greater BIC and BFA ratios compared to the control and the experimental group I (p<0.05). The removal torque values at 8 weeks after implantation were 56 Ncm in the experimental group II, 49 Ncm in the experimental group I and 43 Ncm in the control. There was a statistically significant difference among 3 groups (p<0.05). These results suggest that electrical stimulation improve and accelerate bone healing around endosseous titanium implants in bone defect.

Histological analysis of explanted implant-bone interface: a case report (임플란트 매식체 파절로 제거된 임플란트 골계면의 조직학적 분석 증례)

  • Kim, Dae-Dong;Kang, Dae-Young;Cho, In-Woo;Song, Young-Gyun;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.4
    • /
    • pp.235-243
    • /
    • 2019
  • Osseointegration has been reported to be a dynamic process in which the alveolar bone comes in direct contact with the implant. Various methods were tried to evaluate degree of osseointegration and the measurement of bone-implant contact (BIC) have been commonly used among them. To properly assess the BIC, only histologic analysis is available. However, few studies evaluated BIC of successfully osseointegrated implants in humans. Thus, this is a unique opportunity when implants should be explanted due to inappropriate positioning of implant, presence of pain or sensory disturbance, or broken screw or fixture. This report presents a case of the implant underwent 3-year functional load and a histologic analysis after the fixture fracture. The histomorphometric analysis revealed 53.1% of BIC measured along the whole implant and 70.9% measured only in subcrestal area, respectively. In the present study, although the implant was fractured, a high degree of BIC was observed.

Extensions of X-means with Efficient Learning the Number of Clusters (X-means 확장을 통한 효율적인 집단 개수의 결정)

  • Heo, Gyeong-Yong;Woo, Young-Woon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.772-780
    • /
    • 2008
  • K-means is one of the simplest unsupervised learning algorithms that solve the clustering problem. However K-means suffers the basic shortcoming: the number of clusters k has to be known in advance. In this paper, we propose extensions of X-means, which can estimate the number of clusters using Bayesian information criterion(BIC). We introduce two different versions of algorithm: modified X-means(MX-means) and generalized X-means(GX-means), which employ one full covariance matrix for one cluster and so can estimate the number of clusters efficiently without severe over-fitting which X-means suffers due to its spherical cluster assumption. The algorithms start with one cluster and try to split a cluster iteratively to maximize the BIC score. The former uses K-means algorithm to find a set of optimal clusters with current k, which makes it simple and fast. However it generates wrongly estimated centers when the clusters are overlapped. The latter uses EM algorithm to estimate the parameters and generates more stable clusters even when the clusters are overlapped. Experiments with synthetic data show that the purposed methods can provide a robust estimate of the number of clusters and cluster parameters compared to other existing top-down algorithms.