• Title/Summary/Keyword: BFRP wrapping

Search Result 2, Processing Time 0.015 seconds

Effect of BFRP Wrapping on Seismic Behavior of Rectangular RC Columns (BFRP 보강이 직사각형 단면 철근콘크리트 기둥의 지진거동에 미치는 영향)

  • Lee, Hyerin;Cho, Junghyun;Lee, Seung-Geon;Lee, Su-Hyung;Hong, Kee-Jeung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.153-160
    • /
    • 2020
  • Columns are one of the most critical parts of a structural system subjected to earthquake excitations. In this regard, extensive experimental studies have been conducted to evaluate the effect of fiber reinforced polymer (FRP) wrapping on the seismic performance of reinforced concrete (RC) columns. Among them, many studies focused on the behavior of circular or square RC columns strengthened with CFRP or GFRP sheets. Since the cross-sectional shape affects confinement by FRP wrapping, its strengthening effect and final damage pattern may differ with shapes. In this study, a series of cyclic tests was conducted to investigate the seismic behavior of rectangular reinforced concrete columns strengthened with basalt-based fiber reinforced polymer (BFRP) sheets and composite fiber panels. The result shows that the effect of strengthening is not significant, and it implies a little increase of confinement by BFRP sheets and composite fiber panels, which is considered partly due to the cross-sectional shape of the columns.

Strengthening of isolated square footings using passive wrapping systems

  • Lu, Xingji;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • v.27 no.1
    • /
    • pp.41-54
    • /
    • 2021
  • This paper introduced three new strengthening systems for isolated footings: BFRP wrapping system, CFRP wrapping system, and steel jacketing system. The proposed systems are more practical than the current traditional methods, which involves installing many dowel bars and splicing reinforcing steels to join new and old concrete segments. In the proposed three new systems, BFRP wraps, CFRP wraps, or steel jackets are installed on the exterior surface of the enlarged footing, with construction adhesive or a few steel dowels being applied to the contact surfaces. To investigate the effectiveness of three systems, forty-four models were constructed in ABAQUS, with different parameters being considered. All footings investigated failed in punching shear, including original and retrofitted footings. According to FEA results and parametric studies, the three strengthening systems were capable of improving the punching shear resistance of footings. By introducing a new factor η, the punching shear equation in Eurocode 2 was modified to predict the punching shear resistances of the strengthened footings. A linear formula was developed to present the relationship between the new factor η and the investigated parameters.