• Title/Summary/Keyword: BAS: Building Automation System

Search Result 18, Processing Time 0.021 seconds

Application Technology and Development of CAN Fieldbus Modules for Building Automation System (빌딩시스템용 CAN 필드버스 모듈개발 및 적용에 관한 연구)

  • Lee, Hoon-Jae;Yoon, Chung-Sup;Hong, Won-Pyo;Lee, Jung-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.397-403
    • /
    • 2004
  • The controller area network(CAN) was originally developed to support cheap and rather simple automative applications, However, because of the its performance and low cost, it is also being considered in automated manufacturing and process control environments to interconnect intelligent devices, such as modem sensors and actuators. This paper presents a new application technology of the developed CAN control modules for the automated doors in building automation system. Key pad and RF methods are used to open and close the automated door by the slave CAN module with CAN protocol. BAS application technology of CAN field bus modules is also presented firstly in our nation.

  • PDF

Design and Implementation of Optimal Control Algorithms for Building Energy Management (빌딩 에너지 관리 최적화 알고리즘 설계 및 구현)

  • Jin Jung-Hwa;Chung Sun-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.969-976
    • /
    • 2004
  • Building energy saving is one of the most important issues in these days. Energy saving control strategies should be developed properly to achieve the saving. One of such area we could apply is the HVAC (Heating, Ventilation and Air-Conditioning) system. Through the optimal control algorithm for building energy management system (EMS), you can not only save the cost of building energy, but also protect HVAC system components against the unexpected condition. In order to verify the effectiveness of building energy saving, field test was accomplished for several months at 'A' building. And to get the measured data, remote control was used. If the remote control is used in BAS (Building Automation System), control and monitoring can be done for all of the building systems, such as HVAC, power, lighting, security and fire-alarm etc. anywhere any time. Using the remote control, Control and monitoring is possible for the testing system without going there. As the results of field test, we could reduce $5{\sim}10\%$ of the building energy cost.

Web-based Building Automation System using Embedded Linux (임베디드 리눅스를 이용한 웹 기반 빌딩자동화시스템)

  • 신은철;이수영;최병욱
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.4
    • /
    • pp.334-340
    • /
    • 2004
  • In this paper, a Web-based management system for the building network is described. A multi-protocol converter based on SoC and embedded Linux is designed. The open source licensing, reliability, and broad hardware support are key reasons for use of embedded Linux in embedded industry. The multi-protocol converter integrates control network of RS-485 and LonWorks devices through TCP/IP protocol for a client with Java applet. The system consists of three-tier architecture, such as a client, a server that is performed on a multi-protocol converter, and control devices. The developed system includes the inverter motor control system with modbus protocol for the RS-485 network. The experiment results show that the multi-protocol converter using embedded Linux is a flexible and effective way to builda Web -based monitoring and control system.

Application Technology and Development of CAN Fieldbus Modules for Building Automation and Control System (빌딩자동제어시스템용 CAN 필드버스 모듈개발 및 적용기술에 관한 연구)

  • Hong, Won-Pyo;Seo, Young-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.121-127
    • /
    • 2004
  • The controller area network(CAN) was originally developed to support cheap and rather simple automative applications, However, because of the its performance and low cost, it is also being considered in automated manufacturing and process control environments to interconnect intelligent devices, such as modem sensors and actuators. This paper presents a new application technology of the developed CAN control modules for the automated doors in building automation system Key pad and RF methods are used to open and close the automated door by the slave CAN module with CAN Protocol. BAS application technology of CAN field bus modules is also presented firstly in our nation.

Implementation and Verification Analysis of Micro-EMS for Controlling EES (EES 제어를 위한 Micro-EMS 구현 및 실증 분석)

  • Kim, Kwang-Ho;Kim, Gyu-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.1
    • /
    • pp.155-161
    • /
    • 2015
  • The energy storage system is actively used as the widespread of smart grid. In the case of large scale EES, it can be efficiently controlled linked with BEMS or BAS. But, in the case of EES installed in a small sized household, it needs the help of the remote control system because it lacks the expert for controlling and operating of EES. In addition, in the case when the solar energy generation and EES are installed at the same time, a small sized EMS which can be efficiently controlled depending on the solar energy generation or electric power load is needed. In this paper, the EMS which can efficiently control the solar power generation as well as EES installed in a small sized household is implemented and its usefulness is verified through some experimental studies.

Design of Building Energy Management System Using Big data Platform (빅데이터 플랫폼 기반 건물 에너지 통합 관리 시스템 설계)

  • Kim, Tae-Hyung;Jeong, Yeon-Kwae;Lee, Il-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.04a
    • /
    • pp.580-581
    • /
    • 2016
  • 국제적으로 지속적인 이슈가 되고 있는 에너지 절감에 대한 대책으로 다양한 에너지 절감 기술들이 연구 개발되고 있다. 특히 전체 에너지 사용량의 약 20%이상을 차지하는 건물(가정/상업/공공)부문에서는 에너지 진단 및 분석을 수행하기 위해 건물 에너지 관리 시스템(BEMS: Building Energy Management System)과 건물 자동화 시스템(BAS: Building Automation System) 그리고 다양한 환경정보들을 수집하여 활용한다. 하지만 기존 분석 방식은 결과의 신뢰성에 최소한의 영향을 주면서 데이터 관리 효율을 높이는 방법에 초점을 맞춰 연구가 진행되었으며, 이를 위해 기존에 수집된 데이터를 압축하거나 샘플링하는 사전 정제 과정을 거치게 되었다. 하지만 빅데이터 플랫폼을 활용하면 더 이상 신뢰성을 낮추면서까지 데이터를 정제할 필요가 없어지고, 수집되는 모든 데이터에 대한 다차원 분석을 빠르게 수행할 수 있게 된다. 따라서 본 논문에서는 하드웨어의 한계로 기존 건물에너지 진단 및 분석 시스템에서 제공하지 못했던 다양한 분석 및 진단 서비스들을 빠르고 정확하게 제공하도록 하는 빅데이터 플랫폼 기반 건물 에너지 통합 관리 시스템 설계에 대해 서술한다.

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.

$CO_2$제어 개보수 평가

  • Schell, Mike;Smith, Doug
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.6
    • /
    • pp.49-56
    • /
    • 2003
  • CO2환기제어는 신축건물에서 흔히 사용되고 있지만, 기존의 건물에서는 그 적용 예가 흔하지는 않다. 아마도 개보수라는 것이 가능하다고 여겨지는 자원절감이나 이익에 대한 방대한 기록이 요구되기 때문이며 게다가 제어에 관한 개보수는 복잡하다는 인식에 기인한다. 공교롭게도, 에너지 사용 패턴에 대하 명확한 기록이 있는 기존의 건물에 가장 에너지절약적인 기회가 많다는 사실이다. 이 기고문에서는 기존 건물의 CO2개보수에 관하여 그 성능 평가에 대한 방법론을 제시하고 있으며, 현장 평가와 이 방법론을 적용한 A-등급 사무소 건물에서의 개보수를 통한 성능개선에 관하여 분석하고 있다. 대상은 첨단 DDC시스템이 있는 미국 환경청의 에너지스타 등급을 획득한 건물이다.

  • PDF