• Title/Summary/Keyword: B mode

Search Result 2,433, Processing Time 0.032 seconds

Use of ultrasonography for improving reproductive efficiency in cows II. Comparative evaluation of ovarian structures using ultrasonography and plasma progesterone analysis in subestrous dairy cows (초음파 진단장치를 이용한 축우의 번식효율증진에 관한 연구 II. 무발정 젖소에서 초음파검사 및 progesterone 농도측정에 의한 난소 구조물의 비교평가)

  • Son, Chang-ho;Kang, Byong-kyu;Choi, Han-sun;Kang, Hyun-gu;Paik, In-seok;Suh, Guk-hyun
    • Korean Journal of Veterinary Research
    • /
    • v.38 no.3
    • /
    • pp.642-651
    • /
    • 1998
  • The accuracy of ultrasonography for determining the presence of a functional corpus luteum in subestrous dairy cows was investigated, using a radioimmunoassay for progesterone in plasma. Luteal status (high or low progesterone concentrations) was diagnosed in 534 cows, using B-mode transrectal ultrasonography. Accuracy of ultrasonography was 96.3% and 88.8% in the cows with and without functional corpus luteum, respectively. In 362 cows diagnosed with functional corpus luteum by ultrasonographic examination, 20 cows were diagnosed with the non-functional corpus luteum by analysis of plasma progesterone concentrations (false positive). In 172 cows with non-functional corpus luteum by ultrasonographic examination, 13 cows were diagnosed with the functional corpus luteum based on plasma progesterone assay (false negative). Most of the corpus luteum with well-defined border and homogeneous echotexture were diagnosed with functional corpus luteum. All cows that were not detected a corpus luteum by ultrasonographic examination were diagnosed as non-functional corpus luteum. The corpus luteum of cows that were diagnosed with false positive appeared homogeneous echotexture and above 15 mm in diameter, but the corpus luteum was the non-functional corpus luteum within Day 5 (Day 0 is ovulation day) or after Day 19. The corpus luteum of cows that were diagnosed with false negative appeared heterogeneous echogenicity and below 15 mm in diameter, but the corpus luteum was the functional corpus luteum after Day 5 or around Day 17. It was concluded that accuracy of ultrasonography was excellent for determining the presence of a functional corpus luteum in subestrous dairy cows. The corpus luteum that was diagnosed with false positive or false negative was the developing or regressing states. Thus, ultrasonography was required a serial examination of two or three times accurately diagnosing these corpus luteum.

  • PDF

Ciphering Scheme and Hardware Implementation for MPEG-based Image/Video Security (DCT-기반 영상/비디오 보안을 위한 암호화 기법 및 하드웨어 구현)

  • Park Sung-Ho;Choi Hyun-Jun;Seo Young-Ho;Kim Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.2 s.302
    • /
    • pp.27-36
    • /
    • 2005
  • This thesis proposed an effective encryption method for the DCT-based image/video contents and made it possible to operate in a high speed by implementing it as an optimized hardware. By considering the increase in the amount of the calculation in the image/video compression, reconstruction and encryption, an partial encryption was performed, in which only the important information (DC and DPCM coefficients) were selected as the data to be encrypted. As the result, the encryption cost decreased when all the original image was encrypted. As the encryption algorithm one of the multi-mode AES, DES, or SEED can be used. The proposed encryption method was implemented in software to be experimented with TM-5 for about 1,000 test images. From the result, it was verified that to induce the original image from the encrypted one is not possible. At that situation, the decrease in compression ratio was only $1.6\%$. The hardware encryption system implemented in Verilog-HDL was synthesized to find the gate-level circuit in the SynopsysTM design compiler with the Hynix $0.25{\mu}m$ CMOS Phantom-cell library. Timing simulation was performed by Verilog-XL from CadenceTM, which resulted in the stable operation in the frequency above 100MHz. Accordingly, the proposed encryption method and the implemented hardware are expected to be effectively used as a good solution for the end-to-end security which is considered as one of the important problems.

Clinical Value of Real Time Elastography in Patients with Unexplained Cervical Lymphadenopathy: Quantitative Evaluation

  • Fu, Ying;Shi, Yun-Fei;Yan, Kun;Wang, Yan-Jie;Yang, Wei;Feng, Guo-Shuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.13
    • /
    • pp.5487-5492
    • /
    • 2014
  • Ultrasonography is non-invasive and can give useful clues in the diagnosis of cervical lymphadenopathy, However, differential diagnosis is difficult in some situations even combined with color Doppler imaging. The present study was conducted to evaluate the clinical value of real time elastography in patients with unexplained cervical lymphadenopathy using a quantitative method. From May 2011 to February 2012, 39 enlarged lymph nodes from 39 patients with unexplained cervical lymphadenopathy were assessed. All the patients were examined by both B-mode ultrasound, color Doppler flow imaging and elastography. The method of analyzing elasto-graphic data was the calculation of the 10 parametres ("mean", "sd", "area%", "com", "kur", "ske", "con", "ent", "idm", "asm") offered by the software integrated into the Hitachi system. The findings were then correlated with the definitive tissue diagnosis obtained by lymph node dissection or biopsy. Final histology revealed 10 cases of metastatic lymph nodes, 11 cases of lymphoma, 12 cases of tuberculosis and 6 cases of nonspecific lymphadenitis. The significant distinguishing features for conventional ultrasound were the maximum short diameter (p=0.007) and absent of echogenic hilum (p=0.0293). The diagnostic accuracy was 43.6% (17/39 cases) and there were 17 patients with equivocal diagnosis. For elastography, "mean" (p=0.003), "area%" (p=0.009), "kurt" (p=0.0291), "skew" (p=0.014) and "cont" (p=0.012) demonstrated significant differences between groups. With 9 of the 17 patients with previous equivocal diagnoses (52.9%) definite and correct diagnoses could be obtained. The diagnostic accuracy for conventional ultrasound combined elastography was 69.2% (27/39 cases). There were differences in the diagnostic sensitivity of the two methods (p=0.0224). Ultrasound combined with elastography demonstrated higher rates of conclusive and accurate diagnoses in patients with unexplained cervical lymphadenopathy than conventional ultrasound. The quantitative program showed good correlation with the pathology of different lymph node diseases.

An Admission Control Mechanism to guarantee QoS of Streaming Service in WLAN (WLAN에서 스트리밍 서비스의 QoS를 보장하기 위한 승인 제어 기술)

  • Kang, Seok-Won;Lee, Hyun-Jin;Lee, Kyu-Hwan;Kim, Jae-Hyun;Roh, Byeong-Hee
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.6B
    • /
    • pp.595-604
    • /
    • 2009
  • The HCCA reserves the channel resources based on the mean data rate in IEEE 802.11e. It may cause either the waste of channel resource or the increase of transmission delay at MAC layer if the frame size is rapidly varied when a compressed mode video codec such as MPEG video is used. To solve these problems, it is developed that the packet scheduler allocates the wireless resource adaptation by according to the packet size. However, it is difficult to perform the admission control because of the difficulty with calculating the available resources. In this paper, we propose a CAC mechanism to solve the problem that may not satisfy the QoS by increasing traffic load in case of using EDCA. Especially, the proposed CAC mechanism calculates the EB of TSs using the traffic information transmitted by the application layer and the number of average transmission according to the wireless channel environment, and then determines the admission of the TS based on the EB. According to the simulation results of the proposed CAC mechanism, it admitted the TSs under the loads which are satisfied within the delay bound. Therefore, the proposed mechanism guarantees QoS of streaming services effectively.

Development of Differential Diagnosis and Treatment Method of Reproductive Disorders Using Ultrasonography in Cows II. Differential Diagnosis of Subestrous Dairy Cows (초음파검사에 의한 소의 번식장애 감별진단 및 치료법 개발 II. 무발정우의 감별진단)

  • 강병규;최한선;강현구;오기석;서동호;손창호;서국현
    • Journal of Veterinary Clinics
    • /
    • v.15 no.2
    • /
    • pp.307-318
    • /
    • 1998
  • Accuracy of rectal palpation and ultrasonography for differential diagnosis of subestrous dairy trows were investigatedl using the result of pIRsma progesterone assay. The ovaries were examined 2 times of 10 days interval in 520 posearom and postinsemination subestroHs dairy cows, using rectal palpation and B-mode transrectal ultrasonography. The results of rectal palpation, ultrasonographic examination and measurement of plasma progesterone profiles in 520 subestrous dairy cows were silent brat or error of estrus detection 303 (58.3%), persistent corpus luteum 59 (11.3%), follicular cyst 37 (7.1%), luteal cyst 16 (3.1%), inactive ovary 9 (1.7%), granulosa tumor 1 (0.2%), hydmsalphinx 1 (0.2%), endomehris 81 (15.6%), pyometra 12 (2.3%) and mummified fetus 1 (0.2%), respectively. Accuncy of rectal palpation and ultrasonography for diagiosing ovarian disordeir based on plasma progesterone profiles were silent heat or error of estrus detection 80.5% and 96.7%$\boxUl$ persistent corpus luteum 57.6% and 94.9%, follicular cyst 62.5% and 91.9%1 luteal cyst 62.5% and 87.5%, maclive ovary 55.6% and 88.9% and granulosa cell tumor 100% and 100%, respectively. Acnuucy of rectal palpation for diagnosing uterine disorders based on ultrasonography was pyometra 75.0%1 endometritis 51.9% and mummified fetus 100%, respectively. Cbaracteristic ultrasonographic appearances of ovaries in subestrous dairy cows were as follows; Silent heat or error of estrus detection: anechoic follicle or hypoechoic corpus luteum than ovarian stroma was alternately present on Day 0 (first examination) and Day 10. Follicular cyst: uniformly nonechogenic ovarian structure $\geq $ 25 mm in diameter with a wall < 3 mm was present in ipsilateral on Day 0 and Day 10. Luteal cyst: luteal cyst was similar to follicular cysts but thickness of cystic wall was $\geq $ 3 mm. Inactive ovary : structures within ovaries was not present on Day 0 Bnd Day 10. Characteristic uthssonograpsc appearances of uterus in subestrous dairy cows were as follows; Endometritis: characterized by uterine lumen containing fluid in which 'snowy'echogenic particles art suspended. Pyometra: ultrasonographic appearance of pyometra was diffuse echogenic particles distributed in fluid within the distended uterus, and a thickened uterine wall. These results indicated that ultrasonography was practical far diagnosing reproductive disorders. To diagnosing ovarian disorders, ultrasonography should be carried out 2 times of 10 days interval and rndometritis should be differentiated with uterus of luteal phase in normal cycling cows.

  • PDF

Effect of ${\gamma}$-mangostin through the inhibition of 5-hydroxytryptamine$_{2A}$ receptors in 5-fluoro-${\alpha}$-methyltryptamine-induced head-twitch responses of mice

  • Nattaya Chairungsrie;Furukawa, Ken-Ichi;Takeshi Tadano;Kensuke Kisara;Yasushi Ohizumi
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1998.11a
    • /
    • pp.170-170
    • /
    • 1998
  • In order to discover new types of 5-hydroxytryptamine antagonists, we have devoted our attention to investigating naturally occurring compounds having anti-5HT activity in vitro. Recently, ${\gamma}$-mangostin [1,3,6,7-tetrahydroxy-2,8-bis(3-methyl-2-bytenyl)-9H-xanthen-9-one] from the fruit hull of Garcinia mangostana Linn has been shown to be a selective antagonist for 5-hydroxytryptamine$_{2A}$ receptors in smooth muscle and platelets. It is of interesting that y-mangostin which does not have a nitrogen atom, possesses marked 5-$HT_{2A}$ receptor blocking activity. The present study was undertaken to investigate the effects of ${\gamma}$-mangostin on central 5-HT receptors by using animal behavioural models. Intracerebronventricular injection of ${\gamma}$-mangostin (10-40n mol/mouse) inhibited 5-fluoro-${\alpha}$-methyltryptamin (5-FMT) (45 mg kg$^{-1}$, i.p.)-induced head-twitch response in mice in the presence or absence of citalopram (5-HT-uptake inhibitor). Neither the 5-FMT- nor the 8-hydroxy-2-( di-n-propylamino )tetralin (5-HT$_{1A}$-agonist)-induced 5-HT syndrome (head weaving and hindlimb abduction) was affected by ${\gamma}$-mangostin. The locomotor activity stimulated by 5-FMT through the activation of at-adrenoceptors did not alter in the presence of ${\gamma}$-mangostin. 5-HT-induced inositol phosphates accumulation in mouse brain slices was abolished by ketanserin. ${\gamma}$-Mangostin caused a concentration-dependent inhibition of the inositol phosphates accumulation and the binding of [$^3H$]-spiperone, a specific 5-$HT_{2A}$ receptor antagonist, to mouse brain membranes. Kinetic analysis of the [$^H3$]-spiperone binding revealed that ${\gamma}$-mangostin increased the $_{d}$ value without affecting the $B_{max}$ value, indicating the mode of the competitive nature of the inhibition by ${\gamma}$-mangostin. These results suggest that ${\gamma}$-mangostin inhibits 5-FMT-induced head-twitch response in mice by blocking 5-$HT_{2A}$ receptors not by blocking the release of 5-HT from the central neurone. ${\gamma}$-Mangostin is a promising 5-$HT_{2A}$ receptors antagonist in the central nervous system.m.

  • PDF

Design of video encoder using Multi-dimensional DCT (다차원 DCT를 이용한 비디오 부호화기 설계)

  • Jeon, S.Y.;Choi, W.J.;Oh, S.J.;Jeong, S.Y.;Choi, J.S.;Moon, K.A.;Hong, J.W.;Ahn, C.B.
    • Journal of Broadcast Engineering
    • /
    • v.13 no.5
    • /
    • pp.732-743
    • /
    • 2008
  • In H.264/AVC, 4$\times$4 block transform is used for intra and inter prediction instead of 8$\times$8 block transform. Using small block size coding, H.264/AVC obtains high temporal prediction efficiency, however, it has limitation in utilizing spatial redundancy. Motivated on these points, we propose a multi-dimensional transform which achieves both the accuracy of temporal prediction as well as effective use of spatial redundancy. From preliminary experiments, the proposed multi-dimensional transform achieves higher energy compaction than 2-D DCT used in H.264. We designed an integer-based transform and quantization coder for multi-dimensional coder. Moreover, several additional methods for multi-dimensional coder are proposed, which are cube forming, scan order, mode decision and updating parameters. The Context-based Adaptive Variable-Length Coding (CAVLC) used in H.264 was employed for the entropy coder. Simulation results show that the performance of the multi-dimensional codec appears similar to that of H.264 in lower bit rates although the rate-distortion curves of the multi-dimensional DCT measured by entropy and the number of non-zero coefficients show remarkably higher performance than those of H.264/AVC. This implies that more efficient entropy coder optimized to the statistics of multi-dimensional DCT coefficients and rate-distortion operation are needed to take full advantage of the multi-dimensional DCT. There remains many issues and future works about multi-dimensional coder to improve coding efficiency over H.264/AVC.

Effects of Various Drying Methods of Agar-gel on Dried-agar Quality (한천(寒天) 추출물(抽出物)의 건조방법(乾燥方法)에 따른 한천(寒天)의 품질(品質))

  • Rhee, Chul;Bae, Song-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.78-82
    • /
    • 1984
  • Effects of various drying conditions of agar gel on the physico-chemical properties of dried agar were investigated. For drying of the agar gel$(1.0{\times}1.0{\times}34.0cm)$ by means of sun drying, simple solar drying, hot-air drying ($30^{\circ}C$, control, natural convection), hot-air drying ($30^{\circ}C$, pretreatment, natural convection) and freeze drying, it took 96, 75, 67, 50 and 21 hours, respectively. The gel strengths of dried agar gel prepared by sun drying, solar drying, freeze drying and spray drying were320, 370, 270 and $360g/cm^2$, respectively and that of hot air-dried agar gel was influenced by drying temperature, pretreatment an mode of heat transfer. The gel strength, the gelation temperature and other quality index of spray-dried agar were not inferior to those of sun-dried agar, but it was not expected to be economical because of it recovery rate. In case of hot air drying, the gel strength value of agar increased as the drying rate increased. No significant differences among various products were noted in the gelation temperature, the melting temperature, the ash and $SO_3$ content.

  • PDF

Effect Analysis for Frequency Recovery of 524 MW Energy Storage System for Frequency Regulation by Simulator

  • Lim, Geon-Pyo;Choi, Yo-Han;Park, Chan-Wook;Kim, Soo-Yeol;Chang, Byung-Hoon;Labios, Remund
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.2
    • /
    • pp.227-232
    • /
    • 2016
  • To test the effectiveness of using an energy storage system for frequency regulation, the Energy New Business Laboratory at KEPCO Research Institute installed a 4 MW energy storage system (ESS) demonstration facility at the Jocheon Substation on Jeju Island. And after the successful completion of demonstration operations, a total of 52 MW ESS for frequency regulation was installed in Seo-Anseong (28 MW, governor-free control) and in Shin-Yongin (24 MW, automatic generation control). The control system used in these two sites was based on the control system developed for the 4 MW ESS demonstration facility. KEPCO recently finished the construction of 184 MW ESS for frequency regulation in 8 locations, (e.g. Shin-Gimjae substation, Shin-Gaeryong substation, etc.) and they are currently being tested for automatic operation. KEPCO plans to construct additional ESS facilities (up to a total of about 500 MW for frequency regulation by 2017), thus, various operational tests would first have to be conducted. The high-speed characteristic of ESS can negatively impact the power system in case the 500 MW ESS is not properly operated. At this stage we need to verify how effectively the 500 MW ESS can regulate frequency. In this paper, the effect of using ESS for frequency regulation on the power system of Korea was studied. Simulations were conducted to determine the effect of using a 524 MW ESS for frequency regulation. Models of the power grid and the ESS were developed to verify the performance of the operation system and its control system. When a high capacity power plant is tripped, a 24 MW ESS supplies power automatically and 4 units of 125MW ESS supply power manually. This study only focuses on transient state analysis. It was verified that 500 MW ESS can regulate system frequency faster and more effectively than conventional power plants. Also, it was verified that time-delayed high speed operations of multiple ESS facilities do not negatively impact power system operations. It is recommended that further testing be conducted for a fleet of multiple ESSs with different capacities distributed over multiple substations (e.g. 16, 24, 28, and 48 MW ESS distributed across 20 substations) because each ESS measures frequency individually. The operation of one ESS facility will differ from the other ESSs within the fleet, and may negatively impact the performance of the others. The following are also recommended: (a) studies wherein all ESSs should be operated in automatic mode; (b) studies on the improvement of individual ESS control; and (c) studies on the reapportionment of all ESS energies within the fleet.

Production of Bacterial Cellulose by Pilot Scale and Its Properties (Pilot Scale의 박테리아 셀룰로오스 생산 및 그의 물성)

  • Kim, Seong-Jun;Song, Hyo-Jeong;Chang, Mi-Hwa;Choi, Chang-Nam
    • KSBB Journal
    • /
    • v.22 no.2
    • /
    • pp.91-96
    • /
    • 2007
  • The saccharogenic liquid (SFW) obtained by the enzymatic saccharification of food wastes was used as a medium for production of bacterial cellulose (BC). The enzymatic saccharification of food wastes was carried out by the cultivation supernatant of Tricoderma inhamatum KSJ1 culture. Acetobacter xylinum KJ1 was employed for the BC production culture. Under the scaled-up aeration condition of 1.0 vvm, 5.64 g/L of BC was produced in 3 days cultivation in 50 L air circulation bioreactor using SFW medium with addition of 0.4% agar. The productivity was similar to that of 10 L air circulation bioreactor (5.84 g/L). This cultivation method with 50 L air circulation bioreactor decreasing shear stress and increasing oxygen transfer coefficient ($k_La$) was very useful in BC mass production. The physical properties, such as morphology, molecular weight, crystallinity, and tensile strength of BC produced by the static culture (A), the air circulation culture using 10 L bioreactor (B) and 50 L bioreactor (C) were investigated. The number average molecular weight of BCs produced under the different culture conditions (A-C) showed 2,578,000, 1,975,000, and 1,809,000, respectively. Tensile strength was 1.72 $kg/mm^2$, 1.19 $kg/mm^2$, and 1.18 $kg/mm^2$, respectively. All of the BCs had a form of cellulose I representing pure cellulose. The relative degree of crystallinity showed the range of 86.2$\sim$87.8%. BC production by the air circulation culture mode brought more favorable results in terms of the physical properties and its ease of scale-up. Therefore, it is expected that the new BC production method, the air circulation culture using SFW, would contribute greatly to BC-related manufacturing.