• 제목/요약/키워드: Axial tensile strain

검색결과 93건 처리시간 0.027초

Al-Cu-Zr 합금 초소성 성형품의 기계적 성질 (mechanical properties of Al-Cu-Zr alloy parts by superplastic forming)

  • 이영선
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 춘계학술대회논문집
    • /
    • pp.163-170
    • /
    • 1999
  • Although the bulge forming technique is currently employed in commercial superplastic forming processes, the uniaxial tensile test is still the most commonly used method for the evaluation of the superplasticity of materials due to its simplicity in testing. However, the results obtained from the uniaxial tensile test can not be applied in analyzing the characteristics of the real parts formed in multi-axial stress state. In this paper, using the tensile test specimen obtained from the square cup manufactured by superplastic forming, tensile strength and elongation have been investigated according to the strain and cavity volume fraction. From the result of experiment, tensile strength and elongation are decreased according to the strain and cavity in Al-6%Cu-0.4%Zr alloy. On condition of uniaxial stress, cavity volume fraction is increased on linear according to the increasement of thickness strain. However, on condition of biaxial stress there are critical point( E t=1.5-1.6) that the slope, the ratio of cavity volume fraction and strain, have been changed. Therefore, cavity volume fraction is different with respect to stress condition, although the same strain.

  • PDF

Effects of Pre-Strains on Failure Assessment Analysis to API 5L X65 Pipeline

  • Baek, Jong-Hyun;Kim, Young-Pyo;Kim, Woo-Sik;Seok, Chang-Sung
    • 비파괴검사학회지
    • /
    • 제29권3호
    • /
    • pp.219-223
    • /
    • 2009
  • This paper prescribed the structural integrity of the API 5L X65 pipeline subjected to tensile pre-strain. The effects of pre-strain on the mechanical properties of API 5L X65 pipe were substantially investigated through a variety of the experimental procedures. Axial tensile pre-strain of 1.5, 5 and 10% was applied to plate-type tensile specimens cut from the pipe body prior to mechanical testing. Tensile test revealed that yield strength and tensile strength were increased with increasing tensile pre-strain. The increasing rate of the yield strength owing to the pre-strain is greater than that of the tensile strength. However, the pre-strain up to 5% had a little effect on the decreasing of the fracture toughness. The structural integrity of the API 5L X65 pipeline subjected to large plastic deformation was evaluated through the fitness-for service code.

고온초전도 PIT선재의 반복 열응력 및 변형률 의존성 (Dependence of thermal cycling and axial strain on HTS PIT tapes)

  • 하홍수;이동훈;최정규;양주생;황선역;김상철;하동우;오상수;권영길
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.131-133
    • /
    • 2003
  • The effect of axial strain and thermal cycling on the critical current is investigated for the Bi-2223/Ag PIT tapes. The axial strain was applied to the tapes by the U-shape sample holder. Two kinds of Bi-2223/Ag tapes with different Ag sheath are used to know the effect of sheath alloying for the tensile strain. The influence of thermal cycling between room temperature and 77 K on critical current are examined. Critical current is drastically decreased for Ag/alloy and Ag/alloy/alloy sheathed tapes at tensile strain above 0.22% and 0.3%, respectively.

  • PDF

Experimental comparability between steam and normal curing methods on tensile behavior of RPC

  • Guo, Min;Gao, Ri
    • Advances in concrete construction
    • /
    • 제11권4호
    • /
    • pp.347-356
    • /
    • 2021
  • To address the limitation of the commonly used steam curing of reactive powder concrete (SC-RPC) in engineering, a preparation technology of normal curing reactive powder concrete (NC-RPC) is proposed. In this study, an experimental comparative research on the mechanical properties of NC-RPC and SC-RPC under uniaxial tension is conducted. Under the premise of giving full play to the ultra-high performance of RPC, the paper tries to explore whether normal curing can replace steam curing. The results show that various mechanical indexes of NC-RPC (e.g., tensile strength, ultimate tensile strain, elastic modulus and deformation performance) could basically reach the mechanical index values in steam curing at 28d age, some performance is even better at a longer age. So it affirms the feasibility of normal curing. In this paper, the influence of normal curing age on the tensile properties of RPC is discussed, and the relationship between each index and age is introduced in detail. Based on the experimental data, the tensile mechanism of RPC is analyzed theoretically, and two kinds of tensile constitutive models for RPC are proposed, one is curvilinear model, and another one is polygonal line model. The validity of the two models is further verified by the test results of others.

YBCO CC테이프 임계전류의 인장변형률 특성 (Tensile Strain Characteristics of Critical Current in YBCO Coated Conductors)

  • 신형섭;김기현;오상수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.274-275
    • /
    • 2005
  • The tensile strain dependency of critical current in YBCO coated conductors was examined at 77K and in the self magnetic field. A commercially available YBCO sample with Cu stabilizer layer was supplied. There existed a peak in the relation between the Ie and tensile strain, and the reversible variation of $I_c$ with applied tensile strain was found. In the neutral axis Ni alloy RABiTS-$Y_2O_3$/YSZ/$CeO_2$ buffered YBCO tape, the $I_c$ recovered reversibly until the applied strain reached to about 0.5%, representing that a significant residual compressive strain induced during cooling to 77 K influenced the axial strain tolerance of YBCO conductors. To investigate the strain and stress influence on the $I_c$, the stress-strain characteristics of YBCO conductors measured at 77 K were discussed.

  • PDF

Expanding the classic moment-curvature relation by a new perspective onto its axial strain

  • Petschke, T.;Corres, H.;Ezeberry, J.I.;Perez, A.;Recupero, A.
    • Computers and Concrete
    • /
    • 제11권6호
    • /
    • pp.515-529
    • /
    • 2013
  • The moment-curvature relation for simple bending is a well-studied subject and the classical moment-curvature diagram is commonly found in literature. The influence of axial forces has generally been considered as compression onto symmetrically reinforced cross-sections, thus strain at the reference fiber never has been an issue. However, when dealing with integral structures, which are usually statically indeterminate in different degrees, these concepts are not sufficient. Their horizontal elements are often completely restrained, which, under imposed deformations, leads to moderate compressive or tensile axial forces. The authors propose to analyze conventional beam cross-sections with moment-curvature diagrams considering asymmetrically reinforced cross-sections under combined influence of bending and moderate axial force. In addition a new diagram is introduced that expands the common moment-curvature relation onto the strain variation at the reference fiber. A parametric study presented in this article reveals the significant influence of selected cross-section parameters.

Temperature-dependent axial mechanical properties of Zircaloy-4 with various hydrogen amounts and hydride orientations

  • Bang, Shinhyo;Kim, Ho-a;Noh, Jae-soo;Kim, Donguk;Keum, Kyunghwan;Lee, Youho
    • Nuclear Engineering and Technology
    • /
    • 제54권5호
    • /
    • pp.1579-1587
    • /
    • 2022
  • The effects of hydride amount (20-850 wppm), orientation (circumferential and radial), and temperature (room temperature, 100 ℃, 200 ℃) on the axial mechanical properties of Zircaloy-4 cladding were comprehensively examined. The fraction of radial hydride fraction in the cladding was quantified using PROPHET, an in-house radial hydride fraction analysis code. Uniaxial tensile tests (UTTs) were conducted at various temperatures to obtain the axial mechanical properties. Hydride orientation has a limited effect on the axial mechanical behavior of hydrided Zircaloy-4 cladding. Ultimate tensile stress (UTS) and associated uniform elongation demonstrated limited sensitivity to hydride content under UTT. Statistical uncertainty of UTS was found small, supporting the deterministic approach for the load-failure analysis of hydrided Zircaloy-4 cladding. These properties notably decrease with increasing temperature in the tested range. The dependence of yield strength on hydrogen content differed from temperature to temperature. The ductility-related parameters, such as total elongation, strain energy density (SED), and offset strain decrease with increasing hydride contents. The abrupt loss of ductility in UTT was found at ~700 wppm. Demonstrating a strong correlation between total elongation and offset strain, SED can be used as a comprehensive measure of ductility of hydrided zirconium alloy.

외부자켓에 의해 보강된 콘크리트 압축시편의 압축변형률 측정 및 보정 (Measuring and Correcting The Compressive Axial Strain of Concrete Cylinders Retrofitted by External Jackets)

  • 최은수;이영근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제13권2호통권54호
    • /
    • pp.215-222
    • /
    • 2009
  • 콘크리트 공시편의 외부보강을 위해서 강판과 FRP 자켓을 이용하였다. 기존의 강판 또는 FRP 자켓 보강기법은 보강재와 콘크리트 사이에 접착제를 이용하여 시공하므로 콘크리트와 보강재가 합성거동 하게 된다. 그러나 본 연구에서 사용한 강판 보강기법은 외부압착에 의한 기법으로 강판과 콘크리트가 합성거동을 하지 않는다. 본 연구에서는 비합성거동과 합성거동을 하는 보강된 콘크리트 시편의 압축 변형률의 측정과 이를 보정하는 기법을 제시하였다. 비합성거동의 강판보강 콘크리트 시편의 압축변형률 측정은 강판의 표면에서 변형률을 측정하여 표시할 수 없으며, 시편에 설치하여 측정하는 compressometer를 사용할 수도 없었다. 따라서 시편의 상하단에 두꺼운 판을 설치하여 두 판사이의 변형을 측정한 후. 이를 압축변형률로 변환하였다. 합성 거동을 하는 FRP 보강의 경우는 FRP 튜브 표면에서 측정되는 수직방향의 변형률을 콘크리트의 압축변형률로 사용이 가능하다. 그러나 튜브 표면의 수직변형률은 시편의 부풀음에 의한 인장변형률이 포함되어 있기 때문에 콘크리트의 압축변형률을 추정하기 위해서는 이를 보정하여야 한다. 보정된 압축변형률은 콘크리트 내부에서 측정한 변형률과 기존의 콘크리트 연속체 모델과 비교하였을 때, 만족한 결과를 보였다. 보정 전의 응력-변형률 곡선은 콘크리트의 연성거동 및 에너지 소산능력을 보정 전에 비해 낮게 평가할 위험성이 있다.

Assessment of stress-strain model for UHPC confined by steel tube stub columns

  • Hoang, An Le;Fehling, Ekkehard
    • Structural Engineering and Mechanics
    • /
    • 제63권3호
    • /
    • pp.371-384
    • /
    • 2017
  • Ultra high performance concrete (UHPC) has recently been applied as an alternative to conventional concrete in construction due to its extremely high compressive and tensile strength, and enhanced durability. However, up to date, there has been insufficient information regarding the confinement behavior of UHPC columns. Therefore, this study aims to perform an assessment of axial stress-strain model for UHPC confined by circular steel tube stub columns. The equations for calculating the confined peak stress and its corresponding strain of confined concrete in existing models suggested by Johansson (2002), Sakino et al. (2004), Han et al. (2005), Hatzigeorgiou (2008) were modified based on the regression analysis of test results in Schneider (2006) in order to increase the prediction accuracy for the case of confined UHPC. Furthermore, a new axial stress-strain model for confined UHPC was developed. To examine the suitability of the modified models and the proposed model for confined UHPC, axial stress-strain curves derived from the proposed models were compared with those obtained from previous test results. After validating the proposed model, an extensive parametric study was undertaken to investigate the effects of diameter-to-thickness ratio, steel yield strength and concrete compressive strength on the complete axial stress-strain curves, the strength and strain enhancement of UHPC confined by circular steel tube stub columns.

적층고무베어링과 납-고무베어링의 내진 성능에 관한 실험적 평가 (Experimental Evaluation of Seismic Performance of Laminated Elastomeric Bearing and Lead-Rubber Bearing)

  • 김대곤;이상훈;김대영;박칠림
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.53-62
    • /
    • 1998
  • 구조물의 내진 성능 향상을 위해 현재 종종 사용되어지고 있는 기초분리장치인 적층고베어링과 납-고무 베어링의 내진성능을 실험적으로 파악하였다 베어링의 전단 변형률 또는 가해진 수직 하중이 클수록 베어링의 전단 강성은 감소하며 가력 속도에 대한 영향을 무시할 만하다. 베어링은 순수압축력에는 강하며 인장력에는 그 반대이다.

  • PDF