• 제목/요약/키워드: Axial Scan

검색결과 104건 처리시간 0.031초

두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도 (ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION)

  • 김애지;조봉혜;나경수
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

Temporal bone CT 검사 시 conventional scan 방식과 helical scan방식에 따른 선량 비교분석 (Dose Comparison Analysis of Temporal bone CT scan to conventional scan method during helical scan method)

  • 강수홍;박용성;이래곤;황선광
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.49-56
    • /
    • 2015
  • Temporal bone CT scan side skull fracture. In addition to the confirmation of the ossicles, such as fractures and dislocations, temporomandibular facial fractures, deformities surgery helps to establish a science plan. Cochlear implant surgery has been performed in the state before and after identifying purposes. Test methods are being implemented by the Conventional direct axial and Direct coronal scan, the basic method of Temporal bone CT. Helical scan is a fast Volumetric data obtained compared with the Conventional scan, the patient reduced the dose, and there are some advantages, such as reduced Beam hardening streak artifacts caused by dental fillings. This study is a comparative analysis by dose reduction for patients with a dose according to the conventional scan method and then effective from 2015 by helical scan method performed in 2014 through the retrospective survey, which was then optimized for the purpose of inspection.

  • PDF

CT Scan Mode와 관전압 변경에 따른 소아 두부 영상의 선량 및 영상평가 (Dose and Image Evaluation of Pediatric Head Image according to CT Scan Mode and kVp Changes)

  • 김병제;김동현
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.801-808
    • /
    • 2023
  • 소아 두부 CT 검사 시 방사선 피폭 최소화와 진단적 가치가 높은 영상을 확보하기 위하여 Volume Axial Mode, High Pitch Mode, Helical Mode 간 피폭 선량과 영상의 비교 분석을 통하여 Volume Axial Mode의 유용성을 평가하였다. 1세 미만의 소아 두부 CT Helical Mode, High Pitch Mode, Volume Axial Mode에서 70, 80, 100 kVp의 관전압에 따라 영상평가와 선량평가를 시행하였다. 영상평가는 각 영상에 ROI를 설정해 SNR과 CNR을 산출하여 영상평가를 진행하였으며 일원배치 분산분석(ONE-WAY ANOVA)을 사용하여 통계적 유의성을 평가하였고, 선량평가는 검사 후 장비에서 직접 제공하는 Dose Report에 표시되는 DLP값을 이용하여 비교 분석하였다. Volume Axial Mode를 사용하여 검사하였을 때, DLP 값은 전체적으로 낮게 나왔고, SNR과 CNR은 각각 ROI와 kVp별 차이를 가졌다. Volume Axial Mode가 다른 Scan Mode와 비교하여 영상의 질을 평가하였을 때, 그 차이 값이 균일하지 않아 특정 Mode가 우수하다고 볼 수 없었으나 선량 측면에서는 가장 피폭선량을 줄일 수 있었다. 또한 Volume Axial Mode의 짧은 스캔 시간과 Table의 이동 없이 제자리에서 검사 할 수 있는 점은 방사선 감수성이 높은 1세 미만 소아 CT검사에서 유용하게 적용된다.

암환자의 추적 골스캔에서 관절주위 섭취증가시 전신골섭취계수 측정이 골수전이 평가에 도움이 되는가-골수스캔과의 비교 (The Usefulness of Measurement of Whole Body Count in Assessing Bone Marrow Metastasis in Cancer Patients with Increased Periarticular Bone Uptake on Follow-up Bone Scan: A Comparison with Bone Marrow Scan)

  • 진성찬;최윤영;조석신
    • 대한핵의학회지
    • /
    • 제37권6호
    • /
    • pp.428-436
    • /
    • 2003
  • 목적: 암환자의 추적 골스캔에서 관절주위 섭취증가를 보이는 경우 관절염 이외의 원인으로 말초골수 확장에 의한 이차적 골섭취 증가를 생각할 수 있다. 이 때 막초골수 확장의 원인으로. 즉 중심골수 침범에 의한 이차적 말초골수 확장과 만성빈혈에의한 이차적 골수확장의 감별에 골스캔상 전신골섭 취계수 증가 소견이 도움을 주는지 알아보기 위해 본 연구에서는 암환자의 골스캔상 관절주위 섭취증가 소견을 보인 12명의 환자에서 골스캔과 골수스캔 소견을 비교 분석하였다. 대상 및 방법: 추적 골스캔에서 관절주위 섭취증가를 보인 12명의 암환자에서 1 주일 이내에 Tc-99m colloid 골수스캔을 시행하였다. 골스캔상 전신골섭취계수 증가 여부를 알아보고 골수스캔에서는 중심골 섭취감소 여부와 말초골수 확장여부를 각각 알아 보았다. 임상적으로 관절염, 관절통 여부와 빈혈이 동반되는지 알아 보았다. 결과: 원발암의 진단명은 혈액암 5례, 위암 3례, 유방암 2례, 전립선암 1례, 폐암 1례였다. 남녀비는 7:5 이고 평균연령은 47.5 14.3세였다. 골스캔에서 전신골섭취계수 증가는 3례에서 관찰되었으며 모두 골수스캔상 중심골수 섭취감소 소견과 말초골수 확장 소견을 보여 전신 골수전이로 진단되었다. 골스캔상 전신골섭취계수 증가를 보이지 않았던 9례 중 1례는 중심골수 섭취가 감소되고 말초골수가 확장되었으며 만성골수성백혈병의 급성기로 진단되었다. 7례는 중심골수 섭취는 정상이었고 말초골수 확장이 관찰되었으며 빈혈이 동반되어 있어 악성질환의 만성빈혈로 추정되었다. 결론: 암환자의 추적 골스캔에서 관절주위 섭취증가와 함께 전신골섭취계수가 증가된 경우 전신 골수전이에 의한 이차적 말초골수 확장을 고려해야 하며 이의 감별진단에 골수스캔이 유용한 검사이다.

흉부CT 검사 시 HRCT 영상 재구성의 유용성 (Usefulness Evaluation of HRCT using Reconstruction in Chest CT)

  • 박성민;김긍식;강성민;유병규;이기배
    • 대한디지털의료영상학회논문지
    • /
    • 제17권1호
    • /
    • pp.13-18
    • /
    • 2015
  • Purpose : Skip the repetitive HRCT axial scan in order to reduce the exposure of patients during chest HRCT scan, Helical Scan Data into a reconstructed image, and exposure of the patient change and visually evaluate the usefulness of the HRCT images. Materials and method : Patients were enrolled in the survey are 50 people who underwent chest CT scans of patients who presented to the hospital from January 2015 to March 2015. 50 people surveyed 22 people men and 28 people women people showed an average distribution of 30 to 80 years age was 48 years. 50 patients to Somatom Sensation 64 ch (Siemens) model with 120 kVp tube voltage to a reference mAs tube current to mAs (Care dose, Siemens) as a whole, including the lungs and the chest CT scan was performed. Scan upon each patient CARE dose 4D (Automatic exposure control, Siemens Medical Solution Erlangen, Germany) was to maintain the proper radiation dose scan every cross-section through a device that automatically adjusts the tube current of. CT scan is the rotation time of the Tube slice collimation, slice width 0.6 mm, pitch factor was made under the terms of 1.4. CT scan obtained after the raw data (raw data) to the upper surface of the axial images and coronal images for each slice thickness 1 mm, 5 mm intervals in the high spatial frequency calculation method (hight spatial resolution algorithm, B60 sharp) was the use of the lung window center -500 HU, windows were reconstructed into images in the interval -1000 HU to see. Result : 1. Measure the total value of DLP 50 patients who proceed to chest CT group A (Helical Scan after scan performed with HRCT) and group B (Helical Scan after the HR image reconstruction to the original data) compared with the group divided, analysis As a result of the age, but show little difference for each age group it had a decreased average dose of about 9%. 2. A Radiation read the results of the two Radiologist and a doctor upper lobe and middle lobe of the lung takes effect the visual evaluation is not a big difference between the two images both, depending on the age of the patient, especially if the blood vessels of the lower lobe (A: 3.4, B: 4.6) and bronchi(A: 3.8, B4.7) image shake caused by breathing in anxiety (blurring lead) to the original data (raw data) showed that the reconstructed image is been more useful in diagnostic terms. Conclusion : Scan was confirmed a continuous, rapid motion video to get Helical scan is much lower lobe lung reduction in visual blurring, Helical scan data to not repeat the examination by obtaining HRCT images reorganization reduced the exposure of the patient.

  • PDF

축방향 CT 스캔과 나선형 CT 스캔에서 영·유아의 장기흡수선량 비교 평가 (A Comparative Evaluation of Organ Doses in Infants and toddlers between Axial and Spiral CT Scanning)

  • 김상태;은성종;김성길
    • 한국방사선학회논문지
    • /
    • 제7권2호
    • /
    • pp.137-143
    • /
    • 2013
  • 성인에 비해 방사선에 민감하고 검사건수가 증가하고 있는 영 유아의 CT 스캔 시의 장기흡수선량을 평가하기 위해 스캔부위를 머리부위와 가슴부위로 구분하고 64 MDCT를 이용하여 축방향 스캔과 나선형 스캔으로 비교했다. 스캔부위에 상관없이 나선형 스캔 시의 선량이 축방향 스캔 시 보다 유의하게 낮은 것으로 나타났다. 축방향 스캔과 비교해서 나선형 스캔 중 피치 1.355를 사용했을 때가 나머지 두 피치(0.525, 0.988)를 사용했을 때보다 가슴부위 스캔의 평균 장기흡수선량이 유의하게 높게(평균 -12.03%) 나왔다. 나선형 스캔 시 장기흡수선량이 축방향 스캔보다 평균 20.54% 낮게 나왔다. 결과적으로 인체모형을 통한 장기흡수선량을 평가한 본 연구는 몬테카를로 시뮬레이션 결과값을 실증하고, CT 검사를 받는 영 유아의 장기흡수선량의 보다 정확한 평가에 기여할 것이다.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권5호
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

딥러닝 기반 CT 스캔 재구성을 통한 조영제 사용 및 신체 부위 분류 성능 향상 연구 (A Study on the Use of Contrast Agent and the Improvement of Body Part Classification Performance through Deep Learning-Based CT Scan Reconstruction)

  • 나성원;고유선;김경원
    • 방송공학회논문지
    • /
    • 제28권3호
    • /
    • pp.293-301
    • /
    • 2023
  • 표준화되지 않은 의료 데이터 수집 및 관리는 여전히 수동으로 진행되고 있어, 이 문제를 해결하기 위해 딥 러닝을 사용해 CT 데이터를 분류하는 연구들이 진행되고 있다. 하지만 대부분 연구에서는 기본적인 CT slice인 axial 평면만을 기반으로 모델을 개발하고 있다. CT 영상은 일반 이미지와 다르게 인체 구조만 묘사하기 때문에 CT scan을 재구성하는 것만으로도 더 풍부한 신체적 특징을 나타낼 수 있다. 이 연구는 axial 평면뿐만 아니라 CT 데이터를 2D로 변환하는 여러가지 방법들을 통해 보다 높은 성능을 달성할 수 있는 방법을 찾고자 한다. 훈련은 5가지 부위의 CT 스캔 1042개를 사용했고, 모델 평가를 위해 테스트셋 179개, 외부 데이터셋으로 448개를 수집했다. 딥러닝 모델 개발을 위해 ImageNet으로 사전 학습된 InceptionResNetV2를 백본으로 사용하였으며, 모델의 전체 레이어를 재 학습했다. 실험결과 신체 부위 분류에서는 재구성 데이터 모델이 99.33%를 달성하며 axial 모델보다 1.12% 더 높았고, 조영제 분류에서는 brain과 neck에서만 axial모델이 높았다. 결론적으로 axial slice로만 훈련했을 때 보다 해부학적 특징이 잘 나타나는 데이터로 학습했을 때 더 정확한 성능 달성이 가능했다.

자기공명영상을 이용한 두개부내 표적의 3차원적 위치결정 (Determination of Stereotactic Target Position with MR Localizer)

  • 최태진;김옥배;주양구;서수지;손은익
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.67-77
    • /
    • 1996
  • 목적 : 전신자기공명영상장치의 두개부코일링에 삽입할 수 있는 뇌정위표적기를 제작하고, 횡단면, 시상면 및 관상면에서 표적의 입체적 위치를 결정하여 비교하였다. 방법 : 고강도 합성수지를 이용하여 1.5T 의 전신자기공명 영상장치에서 뇌정위시술용 두 개 부고정환에 부착하여 두개부내 표적위치를 결정할 수 있는 뇌정위표적기를 시험제작하였다. 본 연구에서 시험제작된 뇌정위표적기는 자기공명장치 Magnetom 1.5T(Siemens사, 독일)의 두부코일(외경이 260mm) 내에 설치할 수 있도록 하였으며, 횡단면이나 시상면 또는 관상면에서 표적의 위치를 3차원적으로 결정할 수 있게 하여 각 단면에서 결정된 가상표적의 위치를 비 교하였다. 결과 : 위치가 서로 다른 2개의 가상표적에 대한 모의실험 결과, 횡단면에서 x축의 최대오차는 -1.4mm, y축 -0.7mm, z축 1.lmm를 얻었으며, 시상면에서는 X축 1.3, Y축 1.0mm, Z축 1.lmm, 관상면에서는 X축 -1.4mm, Y축 1.1mm, Z축 -1.5mm로 나타나 횡단면, 시상면 및 관상면에서 구한 표적값이 실험오차범위에서 거의 일치하였다. 결론 : 고강도 합성수지를 이용하여 시험제작한 자기공명영상용 뇌정위표적기를 이용하여 두개부내 표적에 대한 모의실험결과 횡단면, 시상면 및 관상면에서 구해진 표적의 위치가 2mm의 오차범위내에서 실제값에 거의 일치함을 얻었다.

  • PDF

CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구 (COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION)

  • 정기훈;김은경;김상준
    • 치과방사선
    • /
    • 제24권2호
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF