• 제목/요약/키워드: Axial Fan Design

검색결과 131건 처리시간 0.032초

Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan Operating at Different Loading Conditions

  • Baek, Je-Hyun;Lee, Gong-Hee;Myung, Hwan-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.50-60
    • /
    • 2004
  • An experimental analysis using three-dimensional Laser Doppler Velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

블레이드 하중이 축류형 팬에서의 팁 누설 유동구조에 미치는 영향 (Effect of Blade Loading on the Structure of Tip Leakage Flow in a Forward-Swept Axial-Flow Fan)

  • 이공희;명환주;백제현
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.294-304
    • /
    • 2003
  • An experimental analysis using three-dimensional laser Doppler velocimetry(LDV) measurement and computational analysis using the Reynolds stress model in FLUENT are conducted to give a clear understanding of the effect of blade loading on the structure of tip leakage flow in a forward-swept axial-flow fan operating at the maximum efficiency condition ($\Phi$=0.25) and two off-design conditions ($\Phi$=0.21 and 0.30). As the blade loading increases, the onset position of the rolling-up of tip leakage flow moves upstream and the trajectory of tip leakage vortex center is more inclined toward the circumferential direction. Because the casing boundary layer becomes thicker and the mixing between the through-flow and the leakage jet with the different flow direction is enforced, the streamwise vorticity decays more fast with the blade loading increasing. A distinct tip leakage vortex is observed downstream of the blade trailing edge at $\Phi$=0.30, but it is not observed at $\Phi$=0.21 and 0.25.

직교류 홴의 유동 해석: 깃 형상 변화가 성능에 미치는 영향 (A Numerical Study on Flow through a Cross Flow Fan: Effect of Blade Shapes on Fan Performance)

  • 허남건;김욱;강신형
    • 한국유체기계학회 논문집
    • /
    • 제2권1호
    • /
    • pp.96-102
    • /
    • 1999
  • Cross flow fans are used in various applications, especially in industrial ventilation applications and in room air conditioners, due to their superior performance characteristics. Unlike radial and/or axial fans, the design of cross flow fans have been mostly based on earlier experiences and experiments. In the present study, numerical computations of flow fields through a cross flow fan used in room air conditioner are performed to investigate the detailed flow fields and to study the effect of the blade shape on performance curves to aid better design of the fan. Despite some discrepancies between the two results, it is seen from the present study that the computational results agree quite well with the qualitative experimental results. It is also shown from the present study that by having a different shape of blade, it is possible to achieve about $15\%$ increase in flow rates. The stimulating results of the present study can be used in the design of high performance cross flow fans with the use of optimal design algorithm and experimental verifications.

  • PDF

고속 버스용 엔진 냉각 팬의 저소음화 연구 (A Study on the Noise Reduction of the Engine cooling Fan used an Express Bus)

  • 오재응;심현진;이정윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.279-284
    • /
    • 2002
  • In this study, it has been developed the program for predicting the noise spectrum of axial flow fan. The radiated acoustic pressure is expressed the discrete frequency noise peaks at BPF(Blade passage frequency) and its harmonics by Wu's method and the line spectrum at the broad band by Wright's method. And this paper presents the characteristics of a fan noise due to modify the design parameters. Accordingly, it is obtained the design parameter values for noise reduction of fan.

  • PDF

유전자 알고리즘을 이용한 축류 송풍기 설계최적화 (Design Optimization of Axial Flow Fan Using Genetic Algorithm)

  • 이상환;안철오
    • 한국유체기계학회 논문집
    • /
    • 제7권2호
    • /
    • pp.7-13
    • /
    • 2004
  • In an attempt to solve multiobjective optimization problems, weighted sum method is most widely used for the advantage that a designer can consider the relative significance of each object functions by weight values but it can be highly sensitive to weight vector and occasionally yield a deviated optimum from the relative weighting values designer designated because the multiobjective function has the form of simple sum of the product of the weighting values and the object functions in traditional approach. To search the design solution agree well to the designer's weighting values, we proposed new multiobjective function which was the functional of each normalized objective functions and considered to find the design solution comparing the distance between the characteristic line and the ideal optimum. In this study, proposed multiobjective function was applied to design high efficiency and low noise axial flow fan and the result shows this approach is effective for the case that the quality of the design can be highly affected by the designer's subjectiveness represented as weighting values in multiobjective design optimization process.

송풍기 설계를 위한 수치최적설계기법의 응용 (Application of Numerical Optimization Technique to the Design of Fans)

  • 김광용;최재호;김태진;류호선
    • 설비공학논문집
    • /
    • 제7권4호
    • /
    • pp.566-576
    • /
    • 1995
  • A Computational code has been developed in order to design axial fans by the numerical optimization techniques incorporated with flow analysis code solving three-dimensional Navier-Stokes equation. The steepest descent method and the conjugate gradient method are used to look for the search direction in the design space, and the golden section method is used for one-dimensional search. To solve the constrained optimization problem, sequential unconstrained minimization technique, SUMT, is used with imposed quadratic extended interior penalty functions. In the optimization of two-dimensional cascade design, the ratio of drag coefficient to lift coefficient is minimized by the design variables such as maximum thickness, maximum ordinate of camber and chord wise position of maximum ordinate. In the application of this numerical optimization technique to the design of an axial fan, the efficiency is maximized by the design variables related to the sweep angle distributed by quadratic function along the hub to tip of fan.

  • PDF

유전자 알고리즘을 이용한 축류 송풍기 설계최적화 (Design Optimization of Axial Flow Fan Using Genetic Algorithm)

  • 유인태;안철오;이상환
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.397-403
    • /
    • 2003
  • In an attempt to solve multiobjective optimization problems, weighted sum method is most widely used for the advantage that a designer can consider the relative significance of each object functions by weight values but it can be highly sensitive to weight vector and occasionally yield a deviated optimum from the relative weighting values designer designated because the multiobjective function has the form of simple sum of the product of the weighting values and the object functions in traditional approach. To search the design solution well agree to the designer's weighting values, we proposed new multiobjective function which is the functional of each normalized objective functions and considered to find the design solution comparing the distance between the characteristic line and the ideal optimum. In this study, proposed multiobjective function was applied to design high efficiency and low noise axial flow fan and the result shows this approach will be effective for the case that the qualify of the design can be highly affected by the designer's subjectiveness represented as weighting values in multiobjective design optimization process.

  • PDF

Shroud 형상에 대한 해석적 연구 및 '프로벨러 홴' 소개 (Computational Study of the Shr oud Shape & the ProBeller Fan)

  • 한재오;유승훈;모진용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.638-641
    • /
    • 2008
  • Computational investigation was conducted to study the effects of the shape parameter of shroud on the performance of the outdoor unit of an air-conditioners. For this study the Design of Experiment(4-factor 3-level) was created and the an automatic program was composed using VBA to reduce the load of pre-process for CFD. The estimated mathematical equation was produced from this analysis and it was found that the gap between fan and shroud affects more heavily than the other parameters. As a result, the composition of the best parameters was verified that its flow rate was increased by 10 percents and sound pressure level was reduced by 1.2 dBA compare with the worst. And finally, a kind of Propeller fan with blades which were attached to the shroud, so-called 'ProBeller Fan' was introduced in this study.

  • PDF

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

벽걸이에어컨의 원심홴에 대한 과도진동 규명 및 저감 (Transient Vibration Identification and Reduction of a Centrifugal Fan for a Wall-installed Air-conditioner)

  • 김민성;임종혁;정진태
    • 한국소음진동공학회논문집
    • /
    • 제26권4호
    • /
    • pp.383-390
    • /
    • 2016
  • In this paper, experiment and dynamics simulations were carried out to identify and reduce the out-of-plane vibration that occurs in a centrifugal fan of an air conditioner installed to a wall. In a wall-installed air conditioner, large space between a case and heat exchanger is often required for the fan to avoid the collision with the case and exchanger. This large space hinders the slim design of the air conditioner even if air conditioner market demands a slim air conditioner. In the present study, in order to determine the cause of the vibration in the centrifugal fan, the out-of-plane vibration and the physical properties were investigated, and the dynamic characteristics of the centrifugal fan were obtained by experiments. Based on these experiments, a dynamic simulation model was established to determine the cause of the out-of-plane vibration of the centrifugal fan. It was found that the main factor of out-of-plane vibration in the centrifugal fan is the axial misalignment between the centrifugal fan and the motor shaft.