• Title/Summary/Keyword: Average vertical force

Search Result 70, Processing Time 0.021 seconds

Relationship between Impact and Shear Forces, and Shock during Running (달리기 시 충격력과 충격 쇼크 변인들과의 관계)

  • Park, Sang-Kyoon;Ryu, Ji-Seon
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.145-154
    • /
    • 2020
  • Objective: The purpose of this study was to determine the relationship between impact and shear peak force, and tibia-accelerometer variables during running. Method: Twenty-five male heel strike runners (mean age: 23.5±3.6 yrs, mean height: 176.3±3.3 m/s, mean mass: 71.8±9.7 kg) were recruited in this study. The peak impact and anteroposterior shear forces during treadmill running (Bertec, USA) were collected, and impact shock variables were computed by using a triaxial accelerometer (Noraxon, USA). One-way ANOVA was used to test the influence of the running speed on the parameters. Pearson's partial correlation was used to investigate the relationship between the peak impact and shear force, and accelerometer variables. Results: The running speed affected the peak impact and posterior shear force, time, slope, and peak vertical and resultant tibial acceleration, slope at heel contact. Significant correlations were noticed between the peak impact force and peak vertical and resultant tibia acceleration, and between peak impact average slope and peak vertical and resultant tibia acceleration average slope, and between posterior peak (FyP) and peak vertical tibia acceleration, and between posterior peak instantaneous slop and peak vertical tibial acceleration during running at 3 m/s. However, it was observed that correlations between peak impact average slope and peak vertical tibia acceleration average slope, between posterior peak time and peak vertical and resultant tibia acceleration time, between posterior peak instantaneous slope and peak vertical tibial acceleration instantaneous slope during running at 4 m/s. Conclusion: Careful analysis is required when investigating the linear relationship between the impact and shear force, and tibia accelerometer components during relatively fast running speed.

Comparative Analysis of Maximum Vertical Reaction Force and Lower Limbs on Drop Landing between Normal and Flat Foot Group

  • Yoo, Kyung-Tae
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.2 no.1
    • /
    • pp.222-228
    • /
    • 2011
  • With comparison of maximum vertical reaction force and lower limb on drop landing between normal and flat foot group, this study is to provide fundamental data of the prevention of injury and the treatment of exercise which are frequently occurred on flat foot group's drop landing. The surface electrodes were sticked on lateral gastrocnemius muscle, medial gastrocnemius muscle, tibialis anterior and the drop landing on a force plate of 40cm was performed with a normal group who had no musculoskeletal disease and a flat foot group of 9 people who had feet examinations. Vertical reaction force were significantly statistically different between two groups(p<.001). Muscle activity of lower limbs in all three parts were not statistically different but showed high tendency on average in the flat foot group. The flat foot group had difficulties in diversification of impact burden and high muscle activity. Therefore, it was suggested that muscular strengthening of knee joints and plantar flexions of foot joints which were highly affected in impact absorption will be required.

Estimation of Vertical Interaction Force to the End of a Surgical Instrument by Measuring Reaction Force to the Trocar Support (트로카 고정부에 작용하는 반력을 측정하여 수술도구 말단의 수직방향 상호작용 힘을 추정하는 방법)

  • Kim, Suyong;Kim, Cheongjun;Lee, Doo Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.8
    • /
    • pp.615-618
    • /
    • 2016
  • This paper proposes a method to estimate vertical interaction force to the end of the surgical instrument by measuring reaction force at the part supporting the trocar. Relation between the force to the trocar and the interaction force is derived using the beam theory. The vertical interaction force is modeled as a function of the reaction force to the trocar and the distance between the drape plate and the trocar. Experimental results show that error is induced by the asymmetric shape of the trocar tip because contact position between the instrument and the trocar tip is changed depending on the direction of the interaction force. The theoretical relation, therefore, is compensated and reduced. Average $L_2$ relative error of the estimated force in the x-direction and the y-direction is 5.81 % and 5.99 %, respectively.

Contribution Assessment of Roadheader Performance Indexes by Analysis of Variance (분산분석을 이용한 로드헤더 절삭시험 입출력 인자 간의 기여도 조사)

  • Mun-Gyu, Kim;Chang-Heon, Song;Joo-Young, Oh;Jung-Woo, Cho
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.386-396
    • /
    • 2022
  • To analyze the influence of variables of roadheaders, the linear cutting testing data of pick cutter were collected from the former literatures. The input factors were set up as uniaxial compressive strength, cutting depth, cutting spacing, attack angle, skew angle, and output factors were determined as specific energy, average cutting force, maximum cutting force, average vertical force, and maximum vertical force. After composing a table of the design of experiment (DOE). The contribution level of each factor was calculated by analysis of variance (ANOVA). As a result, the factors having greatest influence on cutting force and specific energy were uniaxial compressive strength and cutting spacing.

Evaluation of seismic performance of mid-rise reinforced concrete frames subjected to far-field and near-field ground motions

  • Ansari, Mokhtar;Ansari, Masoud;Safiey, Amir
    • Earthquakes and Structures
    • /
    • v.15 no.5
    • /
    • pp.453-462
    • /
    • 2018
  • Damages to buildings affected by a near-fault strong ground motion are largely attributed to the vertical component of the earthquake resulting in column failures, which could lead to disproportionate building catastrophic collapse in a progressive fashion. Recently, considerable interests are awakening to study effects of earthquake vertical components on structural responses. In this study, detailed modeling and time-history analyses of a 12-story code-conforming reinforced concrete moment frame building carrying the gravity loads, and exposed to once only the horizontal component of, and second time simultaneously the horizontal and vertical components of an ensemble of far-field and near-field earthquakes are conducted. Structural responses inclusive of tension, compression and its fluctuations in columns, the ratio of shear demand to capacity in columns and peak mid-span moment demand in beams are compared with and without the presence of the vertical component of earthquake records. The influences of the existence of earthquake vertical component in both exterior and interior spans are separately studied. Thereafter, the correlation between the increase of demands induced by the vertical component of the earthquake and the ratio of a set of earthquake record characteristic parameters is investigated. It is shown that uplift initiation and the magnitude of tensile forces developed in corner columns are relatively more critical. Presence of vertical component of earthquake leads to a drop in minimum compressive force and initiation of tension in columns. The magnitude of this reduction in the most critical case is recorded on average 84% under near-fault ground motions. Besides, the presence of earthquake vertical components increases the shear capacity required in columns, which is at most 31%. In the best case, a direct correlation of 95% between the increase of the maximum compressive force and the ratio of vertical to horizontal 'effective peak acceleration (EPA)' is observed.

The Immediate Effects of Ankle Restriction Using an Elastic Band on Ground Reaction Force during a Golf Swing

  • Yi, Kyungock;Kim, OkJa
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.2
    • /
    • pp.191-195
    • /
    • 2016
  • Purpose: The purpose of this study was to analyze the immediate effects of ankle restriction with an elastic band on ground reaction force during a golf swing. Method: There were five subjects who were teaching pros with an average golf score of 75. A force platform (9281B, Switzerland) was used. The independent variable was the presence of an elastic band. The dependent variables were three-dimensional ground reaction forces to analyze the transfer of momentum with the timing, control and coordination of the three forces. A paired t-test within subject repeated measure design was used via an SPSS 20.0. Results: Wearing an elastic band around one's ankles significantly makes shorter time differences between the moment of cross anterior / posterior forces and vertical force and median value of anterior / posterior forces during the backswing, between medial and lateral maximum and anterior / posterior force from the top of the back swing to the mid down swing, and creates an anterior / posterior maximum force. Conclusion: Wearing an elastic band around one's ankles affects control and coordination between three dimensional forces, and anterior force power according to each phase of the golf swing.

A Comparative Analysis on Changes of Foot Pressure by Shoe Heel Height during Walking (하이힐 굽 높이에 따른 보행 시 족저압 변화 비교 분석)

  • Park, Jong-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.771-778
    • /
    • 2009
  • We aimed to determine the effect of heel height on foot pressure by comparing and analyzing data on foot pressure in shoes with different heel heights. Qn the basis of a previous study, we selected 3cm and 7cm as the shoe heel heights preferred by female college students. We divided 10 female students into forefoot and hindfoot to measure vertical force, maximum pressure, and average pressure. The average pressure on the forefoot was higher and that on the hindfoot was lower in the case of 7cm high-heeled shoes. The maximum pressure on the forefoot was significantly higher in the case of the 7cm heel height (p<.05). The vertical force, maximum pressure, and average pressure on the hindfoot were also significantly higher in the case of the 7cm heel height (p<.05). The results showed that wearing 7cm high-heeled shoes exerted greater maximum pressure on the forefoot and greater vertical force, maximum pressure, and average pressure on the Hndfoot. This leads to increase in confining pressure caused by high pressure distribution over the forefoot and increase in the pressure on the hindfoot, which may cause deformation of toes and heel pain over a long period. Therefore, female college students who wish to wear high heels are recommended to wear 3cm high-heeled shoes rather than 7cm high-heeled shoes.

The Wind Load Evaluation on Building Considering Vertical Profile of Fluctuating Wind Force (변동풍력의 연직분포를 고려한 건축물의 풍하중 평가)

  • Ryu, Hye-Jin;Shin, Dong-Hyeon;Ha, Young-Cheol
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.157-164
    • /
    • 2019
  • The wind tunnel test makes it possible to predict the wind loads for the wind resistant design. There are many methods to evaluate wind loads from data obtained from the wind tunnel test and these methods have advantages and disadvantages. In this study, two of these methods were analyzed and compared. One is the wind load evaluation method by fluctuating displacement and the other is the wind load evaluation method considering vertical profile of fluctuating wind force. The former method is evaluated as the sum of the mean wind load of the average wind force and the maximum value of the fluctuating wind load. The latter method is evaluated as the sum of the mean wind load and maximum value of the background wind load, and the maximum value of the resonant wind load. Two methods were applied to the wind tunnel test to compare the evaluated wind loads according to the two methods, with a maximum difference of about 1.2 times. The wind load evaluated by the method considering vertical profile of the fluctuating wind force (VPFWF) was larger than the wind load evaluated by the method by fluctuating displacement (FD). Especially, the difference of the wind load according to the two methods is large in the lower part of the building and the wind load is reversed at a specific height of the building. VPFWF of evaluating resonant wind loads and background wind loads separately is more reasonable.

The Flow Control by a Vertical Splitter Plate for a Square Prism near a Wall (벽면 근처에 놓인 정방형주의 수직 분할판에 의한 유동 제어)

  • Ro, Ki-Deok;Cho, Ji-Ryong;Oh, Se-Kyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.94-100
    • /
    • 2012
  • The passive control by vertical splitter plate of fluid force acting on a square prism near a plane wall was studied by measuring of fluid force on the prism and by visualization of the flow field using PIV. The hight of the splitter plate was 10% of the square width. The experimental parameters were the attaching position of vertical splitter plate and the space ratios G/B to the prism height. Time variation of vorticity was most remarkable at 3.0B(B: prism height) position toward wake direction from the center of the prism. The point of inflection of average lift coefficient and Strouhal number on the prism were represented at the space ratio G/B=0.4~0.6 for the prism having vertical splitter plate. The drag of the prism was reduced average 5.0% with the space ratios by attaching the vertical splitter plate at the upper and rear corner on the prism. In this case, the size of the separated region on the upside of the prism was smaller than that of prism having no the splitter plate.

REMOVABLE DENTURE FOR CHILD WITH LOSS OF VERTICAL DIMENSION USING T-SCAN : A CASE REPORT (T-Scan을 이용한 감소된 수직고경을 가진 소아의 가철성 의치 제작)

  • Chung, Yang-Seok;Lee, Chang-Seop;Lee, Sang-Ho;Lee, Nam-Young
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.1
    • /
    • pp.103-108
    • /
    • 2006
  • Loss of permanent molar by multiple dental caries traumatic influence or hereditable disease can cause loss of the vertical dimension in children. However traditionally reconstructive treatment to restore vertical dimension in children has been provided by using simple methods such as celluloid crown form and stainless steel crown. The presented case report describes an alternative treatment modality of vertical dimension by using removalbe appliance This appliance is made with average of facial height and maximal clenching force by using T-scan.

  • PDF