• Title/Summary/Keyword: Average intensity

Search Result 1,178, Processing Time 0.03 seconds

A Study on First Flush Storage Tank Design for Combined Sewer Overflows (CSOs) Control (합류식하수도 월류수 관리를 위한 초기우수 저류조 설계방안 연구)

  • Son, Bongho;Oa, Seongwook
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.5
    • /
    • pp.654-660
    • /
    • 2011
  • One of the best way to control Combined Sewer Overflow (CSO) is proposed to construct first flush storage tank. But there is little known parameters for optimum design of these facilities. This study was conducted to get optimum design parameters for a first flush storage tank construction. The optimization of the tank is generally based upon some measure of SS(Suspended Solid) mass holding efficiency. Water quality deterioration of receiving water body happened right after first time occurring rainfall in dry weather seasons. So, design rainfall intensity is used at 2 mm/hr for peak of monthly average intensities of dry seasons. The capacities for each evaluated catchment are designed from 14.4 min to 16.1 min HRT of CSOs flow at design rainfall intensity. Owing to all storage tanks are connected to interception sewer having a redundancy, the suggested volume could be cut down.

Photoluminescence properties of Mn4+-activated Li2ZnSn2O6 red phosphors

  • Choi, Byoung Su;Lee, Dong Hwa;Ryu, Jeong Ho;Cho, Hyun
    • Journal of Ceramic Processing Research
    • /
    • v.20 no.1
    • /
    • pp.80-83
    • /
    • 2019
  • The Mn4+-activated Li2ZnSn2O6 (LZSO:Mn4+) red phosphors were synthesized by the solid-state reaction at temperatures of 1100-1400 ℃ in air. The synthesized LZSO:Mn4+ phosphors were confirmed to have a single hexagonal LZSO phase without the presence of any secondary phase formed by the Mn4+ addition. With near UV and blue excitation, the LZSO:Mn4+ phosphors exhibited a double band deep-red emission peaked at ~658 nm and ~673 nm due to the 2E → 4A2 transition of Mn4+ ion. PL emission intensity showed a strong dependence on the Mn4+ doping concentration and the 0.3 mol% Mn4+-doped LZSO phosphor produced the strongest PL emission intensity. Photoluminescence emission intensity was also found to be dependent on the calcination temperature and the optimal calcination temperature for the LZSO:Mn4+ phosphors was determined to be 1200 ℃. Dynamic light scattering (DLS) and field-effect scanning electron microscopy (FE-SEM) analysis revealed that the 0.3 mol% Mn4+-doped LZSO phosphor particles have an irregularly round shape and an average particle size of ~1.46 ㎛.

Preparation of Nano-Sized Tin Oxide Powder by Spray Pyrolysis Process (분무열분해(噴霧熱分解) 공정(工程)에 의한 주석(朱錫) 산화물(酸化物) 나노 분말(粉末) 제조(製造))

  • Yu, Jae-Keun;Cha, Kwang-Yong;Kim, Myung-Choun;Han, Joung-Su;Jang, Jae-Bum;Lee, Yong-Hwa;Kim, Dong-Hee
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.79-88
    • /
    • 2008
  • This study is the previous stage for the mass production technology development of the nano-sized tin oxide powder by the recycling of the wasted tin metal, and nano-sized tin oxide powder with the average particle size below 50 nm is prepared from the tin chloride solution by the spray pyrolysis process. As the reaction temperature increases from 800 to 850, the average particle size of the generated powder increases from 20 to 30 nm. As the reaction temperature increases to 900, the droplet type is composed of the particles with the average size of the 30 nm. while the average size of the independent particles increases up to $80{\sim}100$ nm and the surface microstructure becomes more solid. Until $900^{\circ}C$, as the reaction temperature increases, the XRD peak intensity increases, while the specific surface area decreases. When the reaction temperature increases to 950, most of the powder appears with the independent type and the average particle size decrease down to 70 nm. The XRD peak intensity greatly decreases and the specific surface area increases almost twice.

A Study on Efficacy of Preemptive Analgesia - A Comparison on Efficacy of Preoperative and Postoperative Analgesic Administration - (선행적 진통 요법의 효과성에 대한 연구 -발치 전과 후 진통 요법의 효과 비교-)

  • Jung, Young-Soo;Kim, Moon-Key;Park, Hyung-Sik;Lee, Eui-Wung;Kang, Jeong-Wan
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.3 no.1 s.4
    • /
    • pp.10-18
    • /
    • 2003
  • Background: Studies on the pain have been dealing with many different ways for last several centuries. Especially, preemptive analgesia is being used as a method to control the postoperative pain. Many studies on its efficacy have been processed in different ways about various drugs, administration methods and times for various operations. And the value of preemptive analgesia are still controversial regarding the results of other clinical studies. The authors performed a clinical study on efficacy of preemptive analgesia using an non-steroidal anti-inflammatory drug (NSAID) for the surgical extraction of impacted third molar teeth and present the more effective pain treatment after oral surgery with literature review. Methods: Using a randomized double blind test design, this study compared the analgesic efficacies of an NSAID, Talniflumate 370 mg. This drug administrated first either 1 hour preoperatively (experimental group) or when the pain developed moderately to severely over 5 scale of verbal rating scales (0-10) to respective 30 patients undergoing the removal of impacted third molars. Pain intensity and the time from the end of surgery were assessed postoperatively whenever the patients demanded additional drug over 5 scale for forty eight hours using same verbal rating scales. Results: The sex distribution, the age of the patients. and the time required for surgery in two groups were similar. The average first time for demanding additional drug after surgery was 163.9 minutes in experimental group and 191.5 minutes in control group. At this time, the average pain intensity was 5.8 in experimental group and 6.1 in control group. And the average second time for demanding additional drug was 365.5 minutes in experimental group and 351.8 minutes in control group. At this time. the average pain intensities were 6.6 in experimental group and 6.2 in control group. No statistically significant difference was found between the average first times and second times, and the average pain intensities at first and second times in two groups. Conclusions: From these results the efficacy of preemptive analgesia used in this study was not appeared. This clinical study indicates that many NSAIDs administrated preoperatively in present practices have weak efficacy of preemptive analgesia for postoperative pain, thus the authors recommend that only postoperative analgesics are adequate without preoperative use of analgesics.

  • PDF

Color Image Enhancement Using Vector Rotation Based on Color Constancy (칼라 항상성에 기초한 벡터 회전을 이용한 칼라 영상 향상)

  • 김경만;이채수;박영식;하영호
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.181-185
    • /
    • 1996
  • Color image is largely corrupted by various ambient illumination. However, human perceives always white color as white under any illumination because of a characteristic of human vision, called color constancy. In the conventional algorithm which applied the constancy effect, after the RGB color space is transformed to the IHS(Intensity, Hue, and Saturation) color space, then the hue is preserved and the intensity or the saturation is properly enhanced. Then the enhanced IHS color is reversely transformed to the RGB color space. In this process, the color distortion is included due to the color gamut error. But in the proposed algorithm, there is not transformation. In that, the RGB color is considered as 3 dimensional color vector and we assume that white color is the natural daylight. As the color vector of the illumination can be calculated as the average vector of R, G, and B image, we can achieve the constancy effect by simply rotating the illumination vector to the white color vector. The simulation results show the efficiency of the vector rotating process for color image enhancement.

  • PDF

The Dependency of CH* Chemiluminescence of a Laminar Premixed Flame on Fuel Types (연료에 따른 층류 예혼합화염의 CH* Chemiluminescence 신호특성 변화)

  • Lee, Won-Nam;Kang, Suk-Min
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.14-22
    • /
    • 2008
  • The CH* chemiluminescence of premixed flames and their dependency on fuel types has been experimentally investigated on laminar methane and propane premixed flames. The measured chemiluminescence intensities are observed linearly proportional to the fuel flow rate, which could be interpreted as the CH* chemiluminescence signal is linearly proportional to the heat release rate under fuel lean conditions. The effect of equivalence ratio could be expressed by an exponential function as ${I_{CH*}}^{\propto}\;a_1\;{\exp}(b_1{\Phi})$, where $a_1\;=\;0.00054$ and $b_1\;=\;4.60$ for methane and $a_1\;=\;0.0056$ and $b_1\;=\;5.02$ for propane. Oscillating flames showed the temporal fluctuation of chemiluminescence intensity: however, the time averaged values are virtually identical to those of quiescent flames under the same fuel flow rate and equivalence ratio conditions. This observation suggests that there is no significant flame stretch effect on chemiluminescence intensity, in average values.

  • PDF

A study on the Delayed Muscle Soreness after Exercise and the Indicators of Muscle Damage (운동 후 지연된 근통종과 근손상의 지표에 관한 연구)

  • Cho Keun-Jong;Choi Jae-Cheong
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.23-30
    • /
    • 1998
  • The purpose of this study was to analyze the delayed muscle soreness after exercise and the indicators of muscle damage. Subjects of this study were 9 male students. Some muscle enzymes and others(GOT, LDH, ALD, CPK in serum, WBC, ESR) that known as the indicators of muscle damage were measured before exercise. After measurements they run on a treadmill ($incline:25\%$, speed;3.5miles/h) for 7 min. on an average. The intensity of this kind of exercise was $90.5\%$ of maximal exercise intensity. After exercise, same indicators were measured at the just after exercise, 24hr after, 48hr after, 72hr after. Also muscle soreness level was evaluated at same intervals by make use of Modified Abraham's scale. The result was as follow: There was no relationships between muscle soreness and the indicators of muscle damage but ALD was the most important indicator that can be explains the muscle soreness very well.

  • PDF

Prediction model for whistler chorus waves responsible for energetic electron acceleration and scattering

  • Kim, Jin-Hee;Lee, Dae-Young;Cho, Jung-Hee;Shin, Dae-Kyu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.94.1-94.1
    • /
    • 2013
  • Whistler mode chorus waves, which are observed outside the plasmasphere of the Earth's magnetosphere, play a major role in accelerating and scattering energetic electrons in the radiation belts. In this study we developed a predicting scheme of the global distribution of chorus by using the Time History of Events and Macroscale Interactions during Substorms (THEMIS) satellite data. First, we determined global spatial distributions of chorus activity, and identified fit functions that best represent chorus intensities in specific L-MLT zones. Second, we determined the specific dependence of average chorus intensity on preceding solar wind conditions (e.g., solar wind speed, IMF Bz, energy coupling degree) as well as preceding geomagnetic states (as represented by AE, for example). Finally, we combined these two results to develop the predicting functions for the global distribution and intensity of chorus. Implementing these results in the radiation belt models should improve the local acceleration effect by chorus waves.

  • PDF

Uncertainty in the Measurement of Radiative Energy Attenuation through Packed Spheres (구립자층내의 복사에너지 감쇠량계측의 불확정성에 관한 연구)

  • 김춘식;김경근;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.23-29
    • /
    • 1991
  • Uncertainty is studied in the measurements of average packing density, thickness of packed spheres and transmittance in the experiments to study the effect of the bed height and the existence of the bed side walls on the transmittance of radiative energy through packed spheres. The packing density of the bed is obtained by counting the number of the spheres packed in three pipes with different heights. The bed height of the packed spheres is estimated from the number of spheres contained in the bed by using the relation between the bed height and the sphere number. The transmittance is obtained by dividing the intensity of the transmitted laser beam by the incoming-beam intensity. From the analysis, the uncertainity in the measurements of transmittance is shown to be less than 10.2%(95% coverage).

  • PDF

A Study on the Inspection Standards and Methods of Two-Wheeled Motorcycle Headlight (이륜차 전조등 검사기준 및 검사방법에 관한 연구)

  • Ha, Tae-Woong;Hong, Seung-Jun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2020
  • This paper has presented the headlight inspection standards and methods of two-wheeled motorcycles considering Korean Motor Vehicle Safety Standards (KMVSS), Korean Motor Vehicle Inspection Standards (KMVI) and the inspection standards of the International Motor Vehicle Inspection Committee (CITA). As a result of analyzing the headlight luminous intensity test result with fixed inspection equipment, 21% does not meet the inspection standard proposed in this study, and 33.3% in mobile inspection equipment does not meet. The average luminous intensity of motorcycle less than 50 cc is 8,340 cd, so all the lightweight small sized motor cycles do not meet the proposed headlight inspection standard.