• Title/Summary/Keyword: Average Volume Method

Search Result 535, Processing Time 0.025 seconds

A study on the effect of collimator angle on PAN-Pelvis volumetric modulated arc therapy (VMAT) including junction (접합부를 포함한 PAN-전골반암 VMAT 치료 계획 시 콜리메이터 각도의 영향에 관한 고찰)

  • Kim, Hyeon Yeong;Chang, Nam Jun;Jung, Hae Youn;Jeong, Yun Ju;Won, Hui Su;Seok, Jin Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.61-71
    • /
    • 2020
  • Purpose: To investigate the effect of collimator angle on plan quality of PAN-Pelvis Multi-isocenter VMAT plan, dose reproducibility at the junction and impact on set-up error at the junction. Material and method: 10 adult patients with whole pelvis cancer including PAN were selected for the study. Using Trubeam STx equipped with HD MLC, we changed the collimator angle to 20°, 30°, and 45° except 10° which was the default collimator angle in the Eclipse(version 13.7) and all other treatment conditions were set to be the same for each patient and four plans were established also. To evaluate these plans, PTV coverage, coverage index(CVI) and homogeneity index (HI) were compared and clinical indicators for each treatment sites in normal tissues were analyzed. To evaluate dose reproducibility at the junction, the absolute dose was measured using a Falmer type ionization chamber and dose changes at the junction were evaluated by moving the position of the isocenter in and out 1~3mm and setting up the virtual volume at the junction. Result: CVI mean value was PTV-45 0.985±0.004, PTV-55 0.998±0.003 at 45° and HI mean value was PTV-45 1.140±0.074, and PTV-55 1.031±0.074 at 45° which were closest to 1. V20Gy of the kidneys decreased by 9.66% and average dose of bladder and V30 decreased by 1.88% and 2.16% at 45° compared to 10° for the critical organs. The dose value at the junction of the plan and the actual measured were within 0.3% and within tolerance. At the junction, due to set-up error the maximum dose increased to 14.56%, 9.88%, 8.03%, and 7.05%, at 10°, 20°, 30°, 45°, and the minimum dose decreased to 13.18%, 10.91%, 8.42%, and 4.53%, at 10°, 20°, 30°, 45° Conclusion: In terms of CVI, HI of PTV and critical organ protection, overall improved values were shown as the collimator angle increased. The impact on set-up error at the junction by collimator angle decreased as the angle increased and it will help improve the anxiety about the set up error. In conclusion, the collimator angle should be recognized as a factor that can affect the quality of the multi-isocenter VMAT plan and the dose at the junction, and be careful in setting the collimator angle in the treatment plan.

Effects of Telephone Hotline Counseling Program on Stroke Care (뇌졸중 환자에 적용한 핫라인 전화상담 프로그램의 효과)

  • Baik Kyun Kim;Dong-Wan Kang;Do Yeon Kim;Jung Hyun Park;Ji-Seok Woo;Young-Hee Kim;Hyun-Sook Kim;Min-Joo Moon;Jeong-Yoon Lee;Hyung Seok Guk;Nakhoon Kim;Sang-Won Choi;Hakyeu Ahn;Bosco Seong Kyu Yang;Jun Yup Kim;Jihoon Kang;Moon-Ku Han;Hee-Joon Bae;Beom Joon Kim
    • Health Policy and Management
    • /
    • v.33 no.2
    • /
    • pp.185-193
    • /
    • 2023
  • Background: This study focuses on the establishment and operation of a stroke patient hotline program to help patients and their caregivers determine when acute neurological changes require emergency attention. Method: The stroke hotline was established at the Gyeonggi Regional Cerebrovascular Center, Seoul National University Bundang Hospital, in June 2016. Patients diagnosed with stroke during admission or in outpatient clinics were registered and provided with stroke education. Consulting nurses managed hotline calls and made decisions about outpatient schedules or emergency room referrals, consulting physicians when necessary. The study analyzed consultation records from June 2016 to December 2020, assessing consultation volumes and types. Outcomes and hotline satisfaction were also evaluated. Results: Over this period, 6,851 patients were registered, with 1,173 patients (18%) undergoing 3,356 hotline consultations. The average monthly consultation volume increased from 29.2 cases in 2016 to 92.3 cases in 2020. Common consultation types included stroke symptoms (22.3%), blood pressure/glucose inquiries (12.8%), and surgery/procedure questions (12.6%). Unexpected outpatient visits decreased from 103 cases before the hotline to 81 cases after. Among the 2,244 consultations between January 2019 and December 2020, 9.6% were recommended hospital visits, with two cases requiring intra-arterial thrombectomy. Patient satisfaction ratings of 9-10 points increased from 64% in 2019 to 69% in 2020. Conclusion: The stroke hotline program effectively reduced unexpected outpatient visits and achieved high patient satisfaction. Expanding the program could enhance the management of stroke-related neurological symptoms and minimize unnecessary healthcare resource utilization.

The Evaluation of Attenuation Difference and SUV According to Arm Position in Whole Body PET/CT (전신 PET/CT 검사에서 팔의 위치에 따른 감약 정도와 SUV 변화 평가)

  • Kwak, In-Suk;Lee, Hyuk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Purpose: For better PET imaging with accuracy the transmission scanning is inevitably required for attenuation correction. The attenuation is affected by condition of acquisition and patient position, consequently quantitative accuracy may be decreased in emission scan imaging. In this paper, the present study aims at providing the measurement for attenuation varying with the positions of the patient's arm in whole body PET/CT, further performing the comparative analysis over its SUV changes. Materials and Methods: NEMA 1994 PET phantom was filled with $^{18}F$-FDG and the concentration ratio of insert cylinder and background water fit to 4:1. Phantom images were acquired through emission scanning for 4min after conducting transmission scanning by using CT. In an attempt to acquire image at the state that the arm of the patient was positioned at the lower of ahead, image was acquired in away that two pieces of Teflon inserts were used additionally by fixing phantoms at both sides of phantom. The acquired imaged at a were reconstructed by applying the iterative reconstruction method (iteration: 2, subset: 28) as well as attenuation correction using the CT, and then VOI was drawn on each image plane so as to measure CT number and SUV and comparatively analyze axial uniformity (A.U=Standard deviation/Average SUV) of PET images. Results: It was found from the above phantom test that, when comparing two cases of whether Teflon insert was fixed or removed, the CT number of cylinder increased from -5.76 HU to 0 HU, while SUV decreased from 24.64 to 24.29 and A.U from 0.064 to 0.052. And the CT number of background water was identified to increase from -6.14 HU to -0.43 HU, whereas SUV decreased from 6.3 to 5.6 and A.U also decreased from 0.12 to 0.10. In addition, as for the patient image, CT number was verified to increase from 53.09 HU to 58.31 HU and SUV decreased from 24.96 to 21.81 when the patient's arm was positioned over the head rather than when it was lowered. Conclusion: When arms up protocol was applied, the SUV of phantom and patient image was decreased by 1.4% and 9.2% respectively. With the present study it was concluded that in case of PET/CT scanning against the whole body of a patient the position of patient's arm was not so much significant. Especially, the scanning under the condition that the arm is raised over to the head gives rise to more probability that the patient is likely to move due to long scanning time that causes the increase of uptake of $^{18}F$-FDG of brown fat at the shoulder part together with increased pain imposing to the shoulder and discomfort to a patient. As regarding consideration all of such factors, it could be rationally drawn that PET/CT scanning could be made with the arm of the subject lowered.

  • PDF

The Effect of Deep Breathing Methods on Pulmonary Ventilatory Function of Patients Who experiened Upper-abdominal surgery (심호흡 방법에 따른 상복부 수술환자의 폐 환기능에 미치는 효과)

  • Hwang Jin-Hee;Park Hyung-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.1 no.2
    • /
    • pp.129-147
    • /
    • 1994
  • The purpose of this study was to examine the effect of deep breathing exercise with Incentive Spirometer on the pulmonary ventilatory function of postoperative patients. This experiment was operated by quasi-experimental design which was compared pre-experimental measures with post-experimental ones. The subject of this study was 46 inpatients who were scheduled for elective upper abdominal surgery under the general anesthesia in P National University Hospital in Pusan and classified into the experimental group(23 patients) and control group(23 patients) by using Incentive Spirometer or unusing one. The data were collected from November, 1, 1993, to December, 31, 1993. The effects of the deep breathing exercise on the pulmonary ventilatory function were compared between experimental group who were recieved deep breathing exercise with Incentive Spirometer and control group who were recieved same method without Incentive Spirometer. The Forced Vital Capacity (FVC) and the First Second Forced Expiratory Volume ($FEV_1$) were represented as index of the pulmonary ventilatory function and those were measured by Vitalograph Compact. The collected data were analysed by SPSS/PC+ (percentage, average, standard deviation, chi-square test, t-test, and ANOVA). The results were as follow : (1) The $FVC_s$ of the experimental group were significantly increased in course of time, 24, 48, 72 hours after surgery(F=3.530, P=0.035). (2) The $FVC_s$ and $FEV_{1S}$ of the control group were significantly increased in course of time, 24, 48, 72 hours after surgery ($FVC_s$ : F=3.480, P=0.037, $FEV_{1S}$ : F=6. 153, P=0.004). (3) The FVC which was measured at 72 hours after surgery was significantly higher in the experimental group than in the control group(t=2.620, P=0.013). (4) The $FEV_{1s}$ which were measured at 24 and 72 hours after surgery were significantly higher in the experimental group than in the control group(24hr. : t=2.530, P=0.017, 72hr. : t=2.540, P=0.016). (5) Among general characteristics, sex was significant variable which influenced to effect of pulmonary ventilatory function. In conclusion, this study showed that the deep breathing exercise with Incentive Spirometer was more effective to recover the pulmonary ventilatory function after surgery than the deep breathing exercise without Incentive Spirometer.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF