• Title/Summary/Keyword: Average Current Mode

Search Result 161, Processing Time 0.024 seconds

NONLINEAR OUTPUT VOLTAGE CONTROLOF PWM DC-DC CONBERTERS BY FEEDBACK LINERIZATION

  • Jo, Byeong-Rim;Min, Byung-Hoon;Choi, Hang-June
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1995.10a
    • /
    • pp.223-226
    • /
    • 1995
  • New output voltage control technique based on the simple feedback linearization is proposed. The system states are first divided into fast states and slow states. Then, the control stage is composed of the fast inner current control loop and the slow outer voltage control loop. From the inner loop, the average control is derived by the sliding mode concept and it is inserted into the dynamic equations of the slow states in the outer loop. Applying the feedback linearization technique to the obtained large-signal models of the PWM dc-dc converters, linearized large-signal models are obtained for the slow states. With this technique, the output voltage controller of the PWM dc-dc converters can be designed easily in the global state space and its control performance can also be much improved.

  • PDF

High Efficiency AC-DC Converter Using Average-Current Mode Flyback Topology for PDP and Improvement of Hold-up Characteristic (평균전류모드 플라이백 토폴로지를 이용한 PDP용 고효율 AC-DC 컨버터 및 Hold-up 특성 개선)

  • Lee, Kyung-In;Lim, Seung-Beom;Jung, Yong-Min;Oh, Eun-Tae;Lee, Jun-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.2
    • /
    • pp.23-27
    • /
    • 2008
  • Recently, regulation for THD (Total Harmonic Distortion) such as IEC 61000-3-2, IEEE 519 is being reinforced about a product which directly connects to AC line in order to prevent distortion of common power source in electronic equipment and electrical machinery. In order to satisfy these regulations, conventional circuits were used two-stage structure attached power factor correction circuit at ahead of converter but this method complicate the circuit and then a number of element increases thereupon the cost of production rises. in this paper, we propose a high efficiency single-stage 300W PFC fly-back converter that improved power factor and efficiency than conventional two-stage power module.

  • PDF

Using Faster-R-CNN to Improve the Detection Efficiency of Workpiece Irregular Defects

  • Liu, Zhao;Li, Yan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.625-627
    • /
    • 2022
  • In the construction and development of modern industrial production technology, the traditional technology management mode is faced with many problems such as low qualification rates and high application costs. In the research, an improved workpiece defect detection method based on deep learning is proposed, which can control the application cost and improve the detection efficiency of irregular defects. Based on the research of the current situation of deep learning applications, this paper uses the improved Faster R-CNN network structure model as the core detection algorithm to automatically locate and classify the defect areas of the workpiece. Firstly, the robustness of the model was improved by appropriately changing the depth and the number of channels of the backbone network, and the hyperparameters of the improved model were adjusted. Then the deformable convolution is added to improve the detection ability of irregular defects. The final experimental results show that this method's average detection accuracy (mAP) is 4.5% higher than that of other methods. The model with anchor size and aspect ratio (65,129,257,519) and (0.2,0.5,1,1) has the highest defect recognition rate, and the detection accuracy reaches 93.88%.

The Economic Analysis on Traffic Safety Facility along the Inland Waterway Using Probabilistic Simulation -Focusing on the section between Phnom Penh and Chong Kneas port in Cambodia- (확률론적 시뮬레이션을 이용한 내륙수로 교통안전시설의 경제성 분석 -캄보디아의 프롬펜과 총크니아스항 구간을 대상으로-)

  • Kim, Jung-Hoon
    • Journal of Korea Port Economic Association
    • /
    • v.25 no.4
    • /
    • pp.165-182
    • /
    • 2009
  • This study analyzed the economic analysis on the Cambodian inland waterway from Phnom Penh to Chong Kneas. The social discount rate of 3.5% was applied for the cost and benefit of projects and converted to the current values in 2009. The benefits were supposed as the triangle distribution with minimum, mode, and maximum value corresponding to pessimistic, moderate and optimistic prospect separately. And the distributions of costs were the normal. As the result of probabilistic simulations, the average of B/C for scenario A showed relatively the highest with 0.25 and its 90% confidence interval 0.16~0.35. The average B/C of scenario B is 0.10 with the 90% confidence interval 0.06~0.13 and the one of scenario C is 0.15 with 90% confidence interval 0.12~0.19. Therefore it was concluded as low economic feasibility to install inland waterway aids to navigation along the surveyed waterway. However, the performance of the project should be determined by its political analysis as well as the economic.

  • PDF

Impact of openings on the structural performance of ferrocement I-Beams under flexural loads

  • Yousry B.I. Shaheen;Ghada M. Hekal;Ayman M. Elshaboury;Ashraf M. Mahmoud
    • Structural Engineering and Mechanics
    • /
    • v.90 no.4
    • /
    • pp.371-390
    • /
    • 2024
  • Investigating the impact of openings on the structural behavior of ferrocement I-beams with two distinct types of reinforcing metallic and non-metallic meshes is the primary goal of the current study. Up until failure, eight 250x200x2200 mm reinforced concrete I-beams were tested under flexural loadings. Depending on the kind of meshes used for reinforcement, the beams are split into two series. A control I-beam with no openings and three beams with one, two, and three openings, respectively, are found in each series. The two series are reinforced with three layers of welded steel meshes and two layers of tensar meshes, respectively, in order to maintain a constant reinforcement ratio. Structural parameters of investigated beams, including first crack, ultimate load, deflection, ductility index, energy absorption, strain characteristics, crack pattern, and failure mode were reported. The number of mesh layers, the volume fraction of reinforcement, and the kind of reinforcing materials are the primary factors that vary. This article presents the outcomes of a study that examined the experimental and numerical performance of ferrocement reinforced concrete I-beams with and without openings reinforced with welded steel mesh and tensar mesh separately. Utilizing ANSYS-16.0 software, nonlinear finite element analysis (NLFEA) was applied to illustrate how composite RC I-beams with openings behaved. In addition, a parametric study is conducted to explore the variables that can most significantly impact the mechanical behavior of the proposed model, such as the number of openings. The FE simulations produced an acceptable degree of experimental value estimation, as demonstrated by the obtained experimental and numerical results. It is also noteworthy to demonstrate that the strength gained by specimens without openings reinforced with tensar meshes was, on average, 22% less than that of specimens reinforced with welded steel meshes. For specimens with openings, this value is become on average 10%.

Feedback Control Loop Design of DC-DC Converter Systems Using Subcircuit (Subcircuit를 이용한 DC-DC 컨버터 시스템의 피드백 제어루프 설계)

  • Kwon, Soon-Kurl;Lee, Su-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.2
    • /
    • pp.113-118
    • /
    • 2007
  • In this paper, a novel approach to using Subcircuit of Pspice in designing feedback for DC-DC converter systems is proposed. Proposed new approach, the feedback design procedures which are based on small signal modeling are programmed as a subcircuit in Pspice. For this purpose, Analog Behavioral Modeling (ABM) is used. By using the subcircuit, the component values of the error compensation amplifier can be easily obtained by means of Pspice DC analysis. The methodology of development is presented in detail and application examples demonstrated the effectiveness of the proposed approach in designing feedbacks for DC-DC converters. The converter with PWM method used continuous current mode and calculated buck converter control signal with average and linear current technique. To decide pole and zero K-method was adapted and this kind of design procedure took stable function.

  • PDF

Implementation of the BLDC Motor Drive System using PFC converter and DTC (PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현)

  • Yang, Oh
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.5
    • /
    • pp.62-70
    • /
    • 2007
  • In this paper, the boost Power Factor Correction(PFC) technique for Direct Torque Control(DTC) of brushless DC motor drive in the constant torque region is implemented on a TMS320F2812DSP. Unlike conventional six-step PWM current control, by properly selecting the inverter voltage space vectors of the two-phase conduction mode from a simple look-up table at a predefined sampling time, the desired quasi-square wave current is obtained, therefore a much faster torque response is achieved compared to conventional current control. Furthermore, to eliminate the low-frequency torque oscillations caused by the non-ideal trapezoidal shape of the actual back-EMF waveform of the BLDC motor, a pre-stored back-EMF versus position look-up table is designed. The duty cycle of the boost converter is determined by a control algorithm based on the input voltage, output voltage which is the dc-link of the BLDC motor drive, and inductor current using average current control method with input voltage feed-forward compensation during each sampling period of the drive system. With the emergence of high-speed digital signal processors(DSPs), both PFC and simple DTC algorithms can be executed during a single sampling period of the BLDC motor drive. In the proposed method, since no PWM algorithm is required for DTC or BLDC motor drive, only one PWM output for the boost converter with 80 kHz switching frequency is used in a TMS320F2812 DSP. The validity and effectiveness of the proposed DTC of BLDC motor drive scheme with PFC are verified through the experimental results. The test results verify that the proposed PFC for DTC of BLDC motor drive improves power factor considerably from 0.77 to as close as 0.9997 with and without load conditions.

Implementation about measurement of the head SAR and variable parameter according to operation control mode in brain MR study with 1.5Tesia (1.57 BRAIN MRI검사에서의 작동제어모드를 통한 두부 SAR측정과 변화인자에 관한 고찰)

  • Lee, Kyu-Su;Sim, Hyun;Moon, Ji-Hoon;Oh, Jae-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.58-60
    • /
    • 2007
  • Magnetic Resonance Imaging(MRI) has become a very widely used medical procedur e. Clo.sed and open systems are typically used with static magnetic fields at or below 2 Tesla. BWhole body SAR(specific absorbsion rate) is the value of SAR averaged over the entire body of the patient over any period of 15 minutes. Head SAR is the value of SAR averaged over the head of the patient for any period of 10 minutes. SAR is a measure of the absorption of electromagnetic energy in the body' (typically in watts per kilogram (W/kg)). The normal operating mode comprises values of head SAR not higher than 3 W/kg. The second level controlled operating mode comprises values higher than 3 W/kg. Current FDA guidance limits the SAR in the whole body. including the head to a range of 1.5 to 4.0 W/kg, depending on the patient's clinical condition. SAR, limit restrictions are incorporated in all MRI systems. and domestic' s guidance limits the SAR in a part body. including the head to 3.2w/kg and less. The purpose of this study is to evaluate on change of head SAR in using MRI pulse sequence and to check if exceed 3.2(w/kg) level in domestic a part exposure through measured head SAR. 23 patient's the average head SAR of pulse sequence is that T2WI sagittal is 0.5375. T2WI axial(FSE) is 0.4817, T1WI axial(SE) is, 0.8179. FLAIR axial is 0.4580. GRE axial is 0.0077, Diffusion is 0.0824w/kg. The head SAR exposed per patient was proved 2.3845w/kg less than the international standard. Coefficient of correlation for the relations body weight and SAR or for the relations ETL(echo train length) and SAR is 1 value. Coefficient of correlation for the relations between TR(time to repeat) and SAR is -0.602 value. so SAR increased relative to weight body and ETL. But the relations between TR and SAR is negative definite.

  • PDF

Estimating the Determinants of foreign direct investment of korea : A Panel Data Model Approach (페널 데이터모형을 적용한 한국의 해외 직접투자 결정요인 추정에 관한 연구)

  • Kim, Hee-Cheul;Shin, Hyun-Dae
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.4
    • /
    • pp.231-240
    • /
    • 2008
  • In respect complication, group and period, the foreign direct investment of korea is composed of various factors. This paper studies focus on estimating the determinants of foreign direct investment of korea. The region of analysis consist of 7 groups, that is, Asia, Europe, Central and South America, Oceania, Africa, Middle East. Analyzing period be formed over a 67 point(2002. 6${\sim}$2007. 12). In this paper dependent variable setting up an amount of foreign direct investment, explanatory(independent) variables composed of gross domestic product, a balance of current accounts, the foreign exchange rate, employment to population ratio, an average of the rate of operation(the manufacturing industry), consumer price index, the amount of export, wages(a service industry). For an actual proof analysis, LIMDEP 8.0 software, analysis model is random effect in TWECR The result of estimating the determinants of foreign direct investment of korea provides empirical evidences of significance positive relationships between employment to population ratio and wages(a service industry). However this study provides empirical evidences of significance negative relationships between the foreign exchange rate, censurer price index and the amount of export. The explanatory variables, that is, an average of the rate of operation(the manufacturing industry), gross domestic product and a balance of current accounts, are non-significance variables.

  • PDF

Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph (전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.487-496
    • /
    • 2001
  • In this study, a galvanic stimulator providing bipolar mode controlled by a PIC(peripheral interface controller) was constructed to evaluate vestibular function The maximum load and maximum current intensity of the constant current source were 3$k\Omega$ and 5mA. respectively. and it could Produce DC, sine wavers. or Pulse waves. Eve movements of 20 normal subjects by galvanic stimulation were analyzed using a commercial videooculogragh. During stimulating with DC for 30 sec. we recorded the response of eye movement with current intensity of 0.75. 1 2, and 3 mA. Nystagmus occurred to all the subjects when the galvanic stimulus intensity was larger than 2 mA. Average SPV(slow Phase eye movement velocity) and the number of nystagmus increased from 7.1 to 4.8 deg/sec and from 17 to 48, respectively, when the stimulus current increased from 0.75 to 3 mA. All the fast eye movement of the nystagmus were the direction of the negative electrode. The asymmetry which means the difference between right- and left-eye movements decreased when the stimulus intensity increased. It is expected that this study would be useful in evaluating vestibular function and in studying basic Physiology mechanism of vestibular ocular reflex by galvanic stimulus .

  • PDF