• 제목/요약/키워드: Auxiliary power system

검색결과 423건 처리시간 0.026초

Dynamic SOC Compensation of an Ultracapacitor Module for a Hybrid Energy Storage System

  • Song, Hyun-Sik;Jeong, Jin-Beom;Shin, Dong-Hyun;Lee, Baek-Haeng;Kim, Hee-Jun;Heo, Hoon
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.769-776
    • /
    • 2010
  • The ultracapacitor module has recently been recast for use in hybrid energy storage systems (HESSs). As a result, accurate state-of-charge (SOC) estimation for an ultracapacitor module is as important as that of primary sources in order to be utilized efficiently in an energy storage system (ESS). However, while SOC estimation via the open-circuit voltage (OCV) method is generally used due to its linear characteristics compared with other ESSs, this method results in many errors in cases of highcurrent charging/discharging within a short time period. Accordingly, this paper introduces a dynamic SOC estimation algorithm that is capable of SOC compensation of an ultracapacitor module even when there is a current input and output. A cycle profile that simulates the operating conditions of a mild-HEV was applied to a vehicle simulator to verify the effectiveness of the proposed algorithm.

주행거리 확장을 위한 하이브리드형친환경UTV 차량 시스템 개발 (Development of Eco-Friendly Range Extension UTV Hybrid Vehicle System)

  • 김기주;원시태
    • 한국정밀공학회지
    • /
    • 제33권12호
    • /
    • pp.1015-1020
    • /
    • 2016
  • An advantage of electric vehicles is that they are environmentally sustainable because they do not emit exhaust gases, such as $CO_2$ or Nox. A disadvantage is the low power performance of the motor and battery source, necessitating a reduction in the weight of the vehicle to increase efficiency. Another disadvantage is that the rechargeable battery enables an electric vehicle to only run for a limited number of miles before requiring electric charging. To solve these problems, the hybrid vehicle has been developed by combining environmental sustainability with the high performance of a conventional internal combustion engine. In this study, an electric UTV (Utility Terrain Vehicle) was transformed into a hybrid vehicle system by outfitting the vehicle with a drive auxiliary power system including a 125 cc internal combustion engine. This modification enabled us to extend the range of the hybrid UTV from 50km to 100km per one electric charging.

태양광 발전 시스템을 위한 LLC 직렬공진컨버터 적용 무접점 전원장치 (A Contact-less Power Supply using LLC resonant converter for Photovoltaic Power Generation System)

  • 이현관;이기식;강성인;공영수;김은수;김윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.347-350
    • /
    • 2006
  • The high efficiency full-bridge LLC resonant converter using a contact-less transformer is proposed for the photovoltaic power generation system. For the series resonance with a series capacitor, the LLC resonant converter utilizes the leakage inductance and magnetizing inductance of a contact-less transformer. Unlike the conventional series resonant converter operated to the continuous resonant current at above resonance frequency, the proposed converter operates to the discontinuous resonant current at the narrow frequency control range below resonance frequency. Due to the discontinuous mode resonant current, the proposed converter can be achieved the zero voltage switching (ZVS) in the primary switches and the zero current switching (ZCS) in the secondary rectification diodes without any auxiliary circuit. In this paper, the experimental results of the proposed full-bridge LLC resonant converter using a contact-less transfonner are verified on the simulation based on the theoretical analysis and the 150W experimental prototype.

  • PDF

Single Stage 역률보상을 위한 ZVT 풀 브릿지 부스트 컨버터 (Zero Voltage Transition Full Bridge Boost Converter for Single Stage Power Factor Correction)

  • 송두익;권순걸;조정구;백주원;하성운;김종수;임근희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.351-354
    • /
    • 1996
  • A zero-voltage-transition(ZVT) full bridge (FB) boost converter for single stage power factor correction (PFC) in distributed power system is proposed. A simple auxiliary circuit provides zero-voltage-switching(ZVS) condition to all semiconductor devices without imposing additional voltage and current stresses and loss of PWM capability. The proposed boost converter provides both input power factor correction and direct conversion from $110{\sim}220VAC$ line to 300VDC bus with single power stage. Operational principle, analysis of the proposed converter are described and verified by computer simulation and experimental results from a 1.5 kW, 80 kHz laboratory prototype.

  • PDF

Improvement in the DNBR Modeling of RETRAN for Safety Analyses of Westinghouse Nuclear Power Plants

  • Cheong, Ae-Ju;Kim, Yo-Han
    • Nuclear Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.596-609
    • /
    • 2002
  • Korea Electric Power Research Institute has developed the in-house safety analysis methodologies for non-LOCA(Loss Of Coolant Accident) events based on codes and methodologies of vendors and Electric Power Research Institute . According to the new methodologies, analyses of system responses and calculation of DNBR(Departure from Nucleate Boiling Ratio) during the transient have been carried out with RETRAN code and a sub-channel analysis code, respectively. However, it takes too much time to calculate DNBR for each case using the two codes to search for the limiting case from sensitivity study. To simplify the search for the limiting case, accordingly, RETRAN code has been modified to roughly calculate DNBR using hot channel modeling. The W-3 correlation is already included in RETRAN as one of the auxiliary DNBR models. However, WRB-1 and WRB-2 correlations required to analyze some Westinghouse type fuels are not considered in RETRAN DNBR models. In this paper, the RETRAN DNBR models using the correlations have been developed and the partial and complete loss of forced reactor coolant flow events have been analyzed for Yonggwang units 1 and 2 with the new methodologies to validate the models. The results of the analyses have been compared with those mentioned in the chapter 15 of the Final Safety Analysis Report.

Damage and vibrations of nuclear power plant buildings subjected to aircraft crash part I: Model test

  • Li, Z.R.;Li, Z.C.;Dong, Z.F.;Huang, T.;Lu, Y.G.;Rong, J.L.;Wu, H.
    • Nuclear Engineering and Technology
    • /
    • 제53권9호
    • /
    • pp.3068-3084
    • /
    • 2021
  • Investigations of large commercial aircraft impact effect on nuclear power plant (NPP) buildings have been drawing extensive attentions, particularly after the 9/11 event, and this paper aims to experimentally assess the damage and vibrations of NPP buildings subjected to aircraft crash. In present Part I, two shots of reduce-scaled model test of aircraft impacting on NPP building were carried out. Firstly, the 1:15 aircraft model (weighs 135 kg) and RC NPP model (weighs about 70 t) are designed and prepared. Then, based on the large rocket sled loading test platform, the aircraft models were accelerated to impact perpendicularly on the two sides of NPP model, i.e., containment and auxiliary buildings, with a velocity of about 170 m/s. The strain-time histories of rebars within the impact area and acceleration-time histories of each floor of NPP model are derived from the pre-arranged twenty-one strain gauges and twenty tri-axial accelerometers, and the whole impact processes were recorded by three high-speed cameras. The local penetration and perforation failure modes occurred respectively in the collision scenarios of containment and auxiliary buildings, and some suggestions for the NPP design are given. The maximum acceleration in the 1:15 scaled tests is 1785.73 g, and thus the corresponding maximum resultant acceleration in a prototype impact might be about 119 g, which poses a potential threat to the nuclear equipment. Furthermore, it was found that the nonlinear decrease of vibrations along the height was well reflected by the variations of both the maximum resultant vibrations and Cumulative Absolute Velocity (CAV). The present experimental work on the damage and dynamic responses of NPP structure under aircraft impact is firstly presented, which could provide a benchmark basis for further safety assessments of prototype NPP structure as well as inner systems and components against aircraft crash.

가정의 작은 발전소 연료전지 (A small power plant in each household)

  • 신태섭
    • 기술사
    • /
    • 제44권3호
    • /
    • pp.25-29
    • /
    • 2011
  • The fuel cell, a renewable energy facility, hasn t come into wide use to the public. However, the usefulness of it is so high through Supply Business called Green Home, general auxiliary Supply Business, obligation to supply renewable energy for public organizations, Building Certification System and compulsory quota of using renewable energy to power generating businesses, etc. Intial installation was supported by government and a local autonomous entities in case of home fuel cell. Cost-benefits of installing it in home are approximately from $1,000 to $2,500. As Korea applies a progressive tax scheme in home electricity, energy costs are associated with electricity consumption. We should contemplate ways to make effective use of additional waste heat because technology of fuel cell is kind of a cogeneration.

  • PDF

최적조류계산의 분산처리기법에 관한 연구 (An Approach to Implementing Distributed Optimal Power Flow)

  • 김호웅;김발호;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.182-186
    • /
    • 1997
  • This paper presents a mathematical approach to implementing distributed optimal power flow (OPF), wherein a regional decomposition technique is adopted to parallelize the OPF. Three mathematical decomposition coordination methods are introduced firs to implement the proposed distributed scheme: the Auxiliary Problem Principle (APP), the Predictor-Corrector Proximal Multiplier Method (PCPM), and the Alternating Direction Method (ADM). Then two alternative schemes for modeling distributed OPF are introduced; the Dummy Generator-Dummy Generator (DGDG) scheme and Dummy Generator-Dummy Load (DGDL) scheme. We present the mathematical analyses of the proposed approach, and demonstrate the approach on several test, systems, including IEEE Reliability Test Systems and parts of the ERCOT (Electric Reliability Council of Texas) system.

  • PDF

단상 인버터의 동작에 의한 이중접속 3상 전압원 인버터의 출력파형 개선 (Output Waveform Improvement of Double-Connected 3-Phase Voltage Source Inverter by Single-Phase Inverter)

  • 최세완;양승욱
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.21-26
    • /
    • 2001
  • 본 논문에서는 전압원 인버터의 출력전압 파형을 개선하기 위한 새로운 이중접속 3상 전압원 인버터를 제안한다. 보조회로의 단상인버터로 리플전압을 발생시키고 이를 기존의 12-스템 인버터에 주입함으로서 12-스템 동작이 36 스템 동작으로 전환된다. 한편, 출력 측의 결합용 위상 변압기로서 커플링 리액터를 도입하여 변압기의 KVA용 량을 감소시킨다. 또한 본 방식을 포함한 전체의 정류기-인버터 시스템을 제안하고, 실험에 의해 본 방식의 타당성을 입증한다.

  • PDF

ZC-ZVS PWM 승압형 컨버터에 관한 연구 (A Study of ZC-ZVS PWM Boost Converter)

  • 김태우;정효근;안희욱;김학성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.211-214
    • /
    • 2001
  • This paper introduces a ZC-ZVS PWM(Pulse-Width -Modulation) boost converter. The IGBT(main switch) of the proposed converter is always switched at ZCS and soft switching of MOSFET(auxiliary switch) as well. Therefore, the proposed converter minimized the turn on/turn off switching losses of switches and reduced conduction losses by using IGBT switch. Moreover, using paralleled IGBT-MOSFET switch overcame the switching frequency limitation. Therefore high power density system can be realized. As mentioned above, the characteristics are verified through experimental results.

  • PDF