• Title/Summary/Keyword: Auxiliary gas

Search Result 108, Processing Time 0.025 seconds

GMA Torch Configuration for Efficient Use of Argon Gas Part 1 : Effects of AMAG and DMAG Torches on Argon Composition (아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 1 : AMAG와 DMAG 토치가 아르곤 조성에 미치는 영향)

  • 최상균;문명철;유중돈
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.38-45
    • /
    • 1999
  • Shielding gas has significant effects on arc stability, metal transfer and weld quality in the gas metal arc welding (GMAW) process. The double gas-shielded MAG(DMAG) and auxiliary gas-shielded MAG (AMAG) torches are investigated for their capability to provide argon-rich gas mixture using small amount of argon gas through the inner and auxiliary nozzles, respectively. Argon composition with the DMAG torch is calculated numerically, and compared with the measured data using the gas chromatogrphy. Gas flow pattern of the DMAG torch is calculated to change from the laminar to turbulent flow when total gas flow rate becomes larger than 4.5 liter/min at room temperature. While argon-rich shielding gas was obtained using both the AMAG and DMAG torches, the AMAG torch provides higher argon composition than the DMAG torch, which demonstrates that argon gas can be utilized more efficiently with the AMAG torch.

  • PDF

Introduction of Off-Gas Power Plant and Localization Development of Auxiliary Equipment (부생복합발전 소개와 주요설비 국산화를 위한 연구)

  • Ko, Minseok;Kim, Dohyung;Lee, Dongsu;Lee, Seong-geun
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.127-128
    • /
    • 2013
  • Off-gas power plant is a renewable energy power plant which generate electrical energy using the low calorie FOG and BFG as main fuel. This combined cycle power plant is comprised of gas turbines, gas compressors, steam turbines, generators, and auxiliary equipment such as gas mixer, mixing tank, and gas cooler. In this paper, a off-gas power plant and development of its several equipment using CFD are introduced.

  • PDF

GMA Torch Configuration for Efficient Use of Argon Gas Part 2 : Comparison between AMAG DMAG Process (아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 2 : AMAG와 DMAG 공정의 비교)

  • 문명철;고성훈;유중돈
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.46-52
    • /
    • 1999
  • The auxiliary gas-shielded MAG (AMAG) process, which was devised to provide an argon-rich shielding environment using small amount of argon gas, was investigated experimentally to figure out its effects on metal transfer and weld quality. Proper conditions for the AMAG process including the argon gas ratio, position and direction of the auxiliary nozzle were determined experimentally. Performance of the AMAG process was compared with that of the double gas-shielded MAG(DMAG) and MAG processes by monitoring the bead profile, current and voltage waveforms. The AMAG process was found to provide better bead profile, more stable arc and wider operating range of spray transfer mode compared with the DMAG process. In general, performance of the AMAG process using the argon ratio of 30% was comparable to that of the MAG process using 80% argon and 20% CO₂ gas.

  • PDF

Effects of Various Sustain Waveforms on Discharge Characteristics under High Xe Gas Mixture in AC-PDP

  • Park, Dong-Hyun;Cho, Byung-Gwon;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1237-1240
    • /
    • 2005
  • The effects of various sustain waveforms on the discharge characteristics, such as discharge current waveform, IR waveform, luminance, luminous efficiency, power consumption, and static margin are investigated under high Xe (20%) gas mixture at 200 kHz. The four types of sustain waveforms, such as non-overlapped sustain waveform without auxiliary pulse, non-overlapped sustain waveform with auxiliary pulse, overlapped sustain waveform without auxiliary pulse, overlapped sustain waveform with auxiliary pulse, are examined intensively. As a result, the overlapped sustain waveform with auxiliary pulse shows the best discharge characteristics under high Xe (20%) gas mixture at 200 kHz.

  • PDF

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

A Study on the Safety Distance of the Fuelling Facilities by the Radiation Heat in the Fire at the Gas Station (주유소 내 부대시설 화재발생시 복사열에 따른 주유설비 안전거리에 관한 연구)

  • Kim, Kisung;Lee, Sangwon;Song, Dongwoo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.7-13
    • /
    • 2021
  • Various research has been done on fires and explosions at gas stations at home and abroad. However, only studies of off-site damage in the event of fire at the gas station were conducted, and research on fire at the auxiliary facilities in the gas station was insufficient. The gas station is a place where anyone can easily access dangerous goods. As the risk of fire increases due to the recent increase of auxiliary facilities such as convenience stores and car repair shops in gas stations, it is important to detect the effects of fire on the main oil refinery in case of fire and to verify the validity of existing regulations. In this thesis, we conducted a study to find out the effect of radiation heat on the separation between fixed and fixed oil reactors in the event of fire at an auxiliary facility. Simulation was modelled using FDS 5.5.3 Version, and the size of the fire source was configured with 13 fire assessment devices and the heat emission rate per unit area was entered. Simulation shows that the separation distance of 2 m does not secure the safety of the gas pump in the event of fire at the auxiliary facilities, and radiation heat does not damage at the separation distance of at least 4 m. Accordingly, facilities that can block radiant heat in the event of fire at auxiliary facilities, and measures to limit the use of auxiliary facilities or to re-impose the separation between buildings and fixtures will be needed.

A Rational Operation Scheduling Using Genetic Algorithms on Cogeneration System for Paper Mill (제지공장용 열병합발전시스템에서 유전알고리즘을 이용한 합리적 운전계획 수립에 관한 연구)

  • Choi, Kwang-Beom;Lee, Jong-Beom;Jeong, Ji-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.291-293
    • /
    • 1999
  • This paper proposed the optimal operational scheduling of cogeneration system for paper mill connected with several auxiliary devices. Auxiliary devices that include auxiliary boilers, waste heat boilers and sludge incinerators operate with multi-cogeneration systems. Especially environment element was considered in objective function to solve the environment problem. And GAs(Genetic Algorithms) was applied to optimize and to analyse nonlinear operational property of cogeneration system of paper mill connected with several auxiliary devices. C-language was used to GAs computation. Electricity can be purchased through power system from utility. The proposed operational strategy on cogeneration system for paper mill to increase energy efficiency can be applied to the similar cogeneration system of industrial field.

  • PDF

Cycle Analysis of Diffusion Absorption Refrigerator (확산형 흡수식 냉장고의 사이클 해석)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.10
    • /
    • pp.817-824
    • /
    • 2002
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (typically hydrogen). This system has no moving parts and the associated noise and vibration. In this study, the operating characteristics of diffusion absorption refrigerator are investigated through cycle modeling and simulation. System parameters considered in this study are the charged concentration of ammonia aqueous solution, the concentration difference between absorber inlet and outlet and the system pressure determined by the amount of auxiliary gas charged. It was found that there exists a critical value of concentration difference that maximizes the refrigerating capacity. And the lower the system pressure, the higher the refrigerating capacity.

Effects of Charging Conditions on Evaporating Temperature for Diffusion Absorption Refrigerator (확산형 흡수식 냉장고에서 작동매체 충진조건이 증발온도에 미치는 영향)

  • 김선창;김영률;백종현;박승상
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.828-834
    • /
    • 2003
  • A diffusion absorption refrigerator is a heat-generated refrigeration system. It uses a three-component working fluid consisting of the refrigerant (ammonia), the absorbent (water) and the auxiliary gas (hydrogen or helium). In this study, experimental investigations have been carried out to examine the effects of charging conditions of working fluids on the evaporating temperature for diffusion absorption refrigerator. Experimental parameters considered in the present experiments are charging concentration, solution charge and system pressure determined by auxiliary gas charged. As a result, in the charging condition of 35% of concentration and 20 kg$_{f}$cm$^2$ of system pressure, the system has the lowest evaporating temperature. It was found that there exists a minimum value of solution charge for the operation of diffusion absorption refrigerator.r.

Luminous efficacy of 12 lm/W in an AC PDP in terms of measurement of the discharge in Ne+20%Xe and green cells

  • Lee, Sung-Min;Cho, Kwan-Hyun;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.119-122
    • /
    • 2007
  • Dual auxiliary pulses are adopted in an AC PDP with an auxiliary electrode. The secondary auxiliary pulse of dual auxiliary pulses efficiently utilizes priming particles and contributes to improved luminous efficacy. A shorter time interval between the two auxiliary pulses resulted in better efficacy. The maximum luminous efficacy was approximately 12 lm/W according to measurement of the discharge in a Ne+20%Xe gas-mixture and green cells.

  • PDF